diff --git a/compiler/errorf.msg b/compiler/errorf.msg new file mode 100644 index 0000000000..f3492d70f6 --- /dev/null +++ b/compiler/errorf.msg @@ -0,0 +1,1571 @@ +# +# $Id$ +# This file is part of the Free Pascal Compiler +# Copyright (c) 1998 by the Free Pascal Development team +# +# French (cp850) Language File for Free Pascal +# +# See the file COPYING.FPC, included in this distribution, +# for details about the copyright. +# +# This program is distributed in the hope that it will be useful, +# but WITHOUT ANY WARRANTY; without even the implied warranty of +# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. +# +# +# The constants are build in the following order: +# __ +# +# is the part of the compiler the message is used +# asmr_ assembler parsing +# asmw_ assembler writing/binary writers +# unit_ unit handling +# scan_ scanner +# parser_ parser +# type_ type checking +# general_ general info +# exec_ calls to assembler, linker, binder +# +# the type of the message it should normally used for +# f_ fatal error +# e_ error +# w_ warning +# n_ note +# h_ hint +# i_ info +# l_ linenumber +# u_ used +# t_ tried +# m_ macro +# p_ procedure +# c_ conditional +# d_ debug message +# b_ display overloaded procedures +# x_ executable informations +# + +# +# General +# +# BeginOfTeX +% \section{General compiler messages} +% This section gives the compiler messages which are not fatal, but which +% display useful information. The number of such messages can be +% controlled with the various verbosity level \var{-v} switches. +% \begin{description} +general_t_compilername=T_Compilateur : $1 +% When the \var{-vt} switch is used, this line tells you what compiler +% is used. +general_d_sourceos=D_SystŠme d'exploitation source : $1 +% When the \var{-vd} switch is used, this line tells you what the source +% operating system is. +general_i_targetos=I_SystŠme d'exploitation cible : $1 +% When the \var{-vd} switch is used, this line tells you what the target +% operating system is. +general_t_exepath=T_R‚pertoire pour fichiers executables : $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for it's binaries. +general_t_unitpath=T_R‚pertoire de recherche d'unit‚s : $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for compiled units. You can set this path with the \var{-Fu} +general_t_includepath=T_R‚pertoire pour recherche de fichiers inclus : $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for it's include files (files used in \var{\{\$I xxx\}} statements). +% You can set this path with the \var{-I} option. +general_t_librarypath=T_R‚pertoire pour librairies : $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for the libraries. You can set this path with the \var{-Fl} option. +general_t_objectpath=T_R‚pertoire pour fichiers objets : $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for object files you link in (files used in \var{\{\$L xxx\}} statements). +% You can set this path with the \var{-Fo} option. +general_i_abslines_compiled=I_$1 lignes compil‚es, $2 secondes +% When the \var{-vi} switch is used, the compiler reports the number +% of lines compiled, and the time it took to compile them (real time, +% not program time). +general_f_no_memory_left=F_Plus de m‚moire disponible +% The compiler doesn't have enough memory to compile your program. There are +% several remedies for this: +% \begin{itemize} +% \item If you're using the build option of the compiler, try compiling the +% different units manually. +% \item If you're compiling a huge program, split it up in units, and compile +% these separately. +% \item If the previous two don't work, recompile the compiler with a bigger +% heap (you can use the \var{-Ch} option for this, \seeo{Ch}) +% \end{itemize} +% \end{description} +# +# Scanner +# +% \section{Scanner messages.} +% This section lists the messages that the scanner emits. The scanner takes +% care of the lexical structure of the pascal file, i.e. it tries to find +% reserved words, strings, etc. It also takes care of directives and +% conditional compiling handling. +% \begin{description} +scan_f_end_of_file=F_Fin de fichier inattendue +% this typically happens in on of the following cases : +% \begin{itemize} +% \item The source file ends befor then final \var{end.} statement. This +% happens mostly when the \var{begin} and \var{end} statements aren't +% balanced; +% \item An include file ends in the middle of a statement. +% \item A comment wasn't closed. +% \end{itemize} +scan_f_string_exceeds_line=F_String au-del… de la fin de ligne +% You forgot probably to include the closing ' in a string, so it occupies +% multiple lines. +scan_f_illegal_char=F_caractŠre ill‚gal +% An illegal character was encountered in the input file. +scan_f_syn_expected=F_Erreur de syntaxe, $1 attendu mais $2 trouv‚ +% This indicates that the compiler expected a different token than +% the one you typed. It can occur almost everywhere where you make a +% mistake against the pascal language. +scan_t_start_include_file=T_D‚but de lecture du fichier inclus $1 +% When you provide the \var{-vt} switch, the compiler tells you +% when it starts reading an included file. +scan_w_comment_level=W_Commentaire de niveau $1 +% When the \var{-vw} switch is used, then the compiler warns you if +% it finds nested comments. Nested comments are not allowed in Turbo Pascal +% and can be a possible source of errors. +scan_n_far_directive_ignored=N_$F directive (FAR) ignor‚e +% The \var{FAR} directive is a 16-bit construction which is recorgnised +% but ignored by the compiler, since it produces 32 bit code. +scan_n_stack_check_global_under_linux=N_Le controle de la gestion de la pile est global sous Linux +% Stack checking with the \var{-Cs} switch is ignored under \linux, since +% \linux does this for you. Only displayed when \var{-vn} is used. +scan_n_ignored_switch=N_Switch "$1" ignor‚ +% With \var{-vn} on, the compiler warns if it ignores a switch +scan_w_illegal_switch=W_Switch "$1" ill‚gal +% You included a compiler switch (i.e. \var{\{\$... \}}) which the compiler +% doesn't know. +scan_w_switch_is_global=W_Ce switch a un effet global +% When \var{-vw} is used, the compiler warns if a switch is global. +scan_e_illegal_char_const=E_Constante de type char ill‚gale +% This happens when you specify a character with its ASCII code, as in +% \var{\#96}, but the number is either illegal, or out of range. The range +% is 1-255. +scan_f_cannot_open_input=F_Impossible d'ouvrir le fichier $1 +% \fpc cannot find the program or unit source file you specified on the +% command line. +scan_f_cannot_open_includefile=F_Impossible d'ouvrir le fichier inclus $1 +% \fpc cannot find the source file you specified in a \var{\{\$include \}} +% stateent. +scan_e_too_much_endifs=E_Trop de $ENDIFs ou de $ELSEs +% Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced. +scan_w_only_pack_records=W_L'alignement des Records peut uniquement ˆtre de 1,2,4,8 ou 16 bytes +% You are specifying the \var{\{\$PACKRECORDS n\} } with an illegal value for +% \var{n}. Only 1,2,4 or 16 are valid in this case. +scan_w_only_pack_enum=W_Les ‚numerations peuvent seulement ˆtre sauvegard‚s en 1,2 ou 4 bytes +% You are specifying the \var{\{\$PACKENUM n\}} with an illegal value for +% \var{n}. Only 1,2 or 4 are valid in this case. +scan_e_endif_expected=E_$1 attendu pour $2 d‚fini … la ligne $3 +% Your conditional compilation statements are unbalanced. +scan_e_preproc_syntax_error=E_Erreur de syntaxe pendant l'interpr‚tation d'une directive de compilation +% There is an error in the expression following the \var{\{\$if \}} compiler +% directive. +scan_e_error_in_preproc_expr=E_Erreur d'‚valuation d'une directive de compilation +% There is an error in the expression following the \var{\{\$if \}} compiler +% directive. +scan_w_marco_cut_after_255_chars=W_Le contenu d'une macro est tronqu‚ … 255 caractŠres +% The contents of macros canno be longer than 255 characters. This is a +% safety in the compiler, to prevent buffer overflows. This is shown as a +% warning, i.e. when the \var{-vw} switch is used. +scan_e_endif_without_if=E_ENDIF sans IF(N)DEF +% Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced. +scan_f_user_defined=F_D‚fini par l'utilisateur : $1 +% A user defined fatal error occurred. see also the \progref +scan_e_user_defined=E_D‚fini par l'utilisateur : $1 +% A user defined error occurred. see also the \progref +scan_w_user_defined=W_D‚fini par l'utilisateur : $1 +% A user defined warning occurred. see also the \progref +scan_n_user_defined=N_D‚fini par l'utilisateur : $1 +% A user defined note was encountered. see also the \progref +scan_h_user_defined=H_D‚fini par l'utilisateur : $1 +% A user defined hint was encountered. see also the \progref +scan_i_user_defined=I_D‚fini par l'utilisateur : $1 +% User defined information was encountered. see also the \progref +scan_e_keyword_cant_be_a_macro=E_Impossible de redefinir un mot r‚serv‚ +% You cannot redefine keywords with macros. +scan_f_macro_buffer_overflow=F_D‚bordement du buffer de la macro en lecture ou expansion +% Your macro or it's result was too long for the compiler. +scan_w_macro_deep_ten=W_L'expansion des macros d‚passe un niveau de 16. +% When expanding a macro macros have been nested to a level of 16. +% The compiler will expand no further, since this may be a sign that +% recursion is used. +scan_e_wrong_styled_switch=E_Les directives de compilation entre (* ... *) ne sont pas accept‚es +% Compiler switches should always be between \var{\{ \}} comment delimiters. +scan_d_handling_switch=D_Interpr‚tation switch "$1" +% When you set debugging info on (\var{-vd}) the compiler tells you when it +% is evaluating conditional compile statements. +scan_c_endif_found=C_ENDIF $1 trouv‚ +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_ifdef_found=C_IFDEF $1 trouv‚, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_ifopt_found=C_IFOPT $1 trouv‚, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_if_found=C_IF $1 trouv‚, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_ifndef_found=C_IFNDEF $1 trouv‚, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_else_found=C_ELSE $1 trouv‚, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_skipping_until=C_Passant jusqu'…... +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements, and whether it is skipping or +% compiling parts. +scan_i_press_enter=I_Appuyez sur pour continuer +% When the \var{-vi} switch is used, the compiler stops compilation +% and waits for the \var{Enter} key to be pressed when it encounters +% a \var{\{\$STOP\}} directive. +scan_w_unsupported_switch=W_Switch non support‚ $1 +% When warings are turned on (\var{-vw}) the compiler warns you about +% unsupported switches. This means that the switch is used in Delphi or +% Turbo Pascal, but not in \fpc +scan_w_illegal_directive=W_directive de compilation ill‚gale $1 +% When warings are turned on (\var{-vw}) the compiler warns you about +% unrecognised switches. For a list of recognised switches, \progref +scan_t_back_in=T_De retour dans $1 +% When you use (\var{-vt}) the compiler tells you when it has finished +% reading an include file. +scan_w_unsupported_app_type=W_Type d'application non support‚e : $1 +% You get this warning, ff you specify an unknown application type +% with the directive $APPTYPE +scan_w_app_type_not_support=W_$APPTYPE non support‚ par OS cible +% The $APPTYPE directive is supported by win32 applications only +scan_w_unsupported_asmmode_specifier=W_Style assembleur non support‚ $1 +% When you specify an assembler mode with the \var{\{\$ASMMODE xxx\}} +% the compiler didn't recognize the mode you specified. +scan_w_no_asm_reader_switch_inside_asm=W_Changement de type d'interpr‚teur ASM … l'int‚rieur de code assembleur, $1 sera effectif seulement pour le prochain +% It is not possible to switch from one assembler reader to another +% inside an assmebler block. The new reader will be used for next +% assembler statement only. +scan_e_wrong_switch_toggle=E_Mauvais argument de switch, utilisez ON/OFF ou +/- +% You need to use ON or OFF or a + or - to toggle the switch +scan_e_resourcefiles_not_supported=E_Fichiers ressource non support‚ pour cette cible +% The target you are compiling for doesn't support Resource files. The +% only target which can use resource files is Win32 +% +% \end{description} +# +# Parser +# +% \section{Parser messages} +% This section lists all parser messages. The parser takes care of the +% semantics of you language, i.e. it determines if your pascal constructs +% are correct. +% \begin{description} +parser_e_syntax_error=E_Parseur - Erreur de syntaxe +% An error against the Turbo Pascal language was encountered. This happens +% typically when an illegal character is found in the sources file. +parser_w_proc_far_ignored=W_Directive pour proc‚dure FAR ignor‚ +% This is a warning. \var{FAR} is a construct for 8 or 16 bit programs. Since +% the compile generates 32 bit programs, it ignores this directive. +parser_w_proc_near_ignored=W_Directive pour proc‚dure NEAR ignor‚ +% This is a warning. \var{NEAR} is a construct for 8 or 16 bit programs. Since +% the compile generates 32 bit programs, it ignores this directive. +parser_w_proc_register_ignored=W_Diretive pour proc‚dure REGISTER ignor‚ +% This is a warning. \var{REGISTER} is ignored by FPC programs for now. +% This is introduced first for Delphi compatibility. +parser_e_no_dll_file_specified=E_Pas de fichier DLL sp‚cifi‚ +% No longer in use. +parser_e_export_name_double=E_Nom de fonction export‚e doubl‚ $1 +% Exported function names inside a specific DLL must all be different +parser_e_export_ordinal_double=E_Index de fonction export‚e doubl‚ $1 +% Exported function names inside a specific DLL must all be different +parser_e_export_invalid_index=E_Index non valide pour fonction export‚e +% DLL function index must be in the range 1..$FFFF +parser_e_constructorname_must_be_init=E_Le nom du constructeur doit ˆtre INIT +% You are declaring a constructor with a name which isn't \var{init}, and the +% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}). +parser_e_destructorname_must_be_done=E_Le nom du destructeur doit ˆtre DONE +% You are declaring a constructor with a name which isn't \var{done}, and the +% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}). +parser_e_illegal_open_parameter=E_ParamŠtre ouvert non valide +% You are trying to use the wrong type for an open parameter. +parser_e_proc_inline_not_supported=E_Directive de fonction INLINE non support‚e +% You tried to compile a program with C++ style inlining, and forgot to +% specify the \var{-Si} option (\seeo{Si}). The compiler doesn't support C++ +% styled inlining by default. +parser_w_priv_meth_not_virtual=W_Les m‚thodes priv‚es ne devraient pas ˆtre virutelles +% You declared a method in the private part of a object (class) as +% \var{virtual}. This is not allowed. Private methods cannot be overridden +% anyway. +parser_w_constructor_should_be_public=W_Le constructeur devrait ˆtre public +% Constructors must be in the 'public' part of an object (class) declaration. +parser_w_destructor_should_be_public=W_Le destructeur devrait ˆtre public +% Destructors must be in the 'public' part of an object (class) declaration. +parser_n_only_one_destructor=N_Les classes ne devraient avoir qu'un selu destructeur +% You can declare only one destructor for a class. +parser_e_no_local_objects=E_Les D‚finitions locales de classes ne sont pas autoris‚es +% Classes must be defined globally. They cannot be defined inside a +% procedure or function +parser_f_no_anonym_objects=F_Les d‚finitions de classes anonymes sont interdites +% An invalid object (class) declaration was encountered, i.e. an +% object or class without methods that isn't derived from another object or +% class. For example: +% \begin{verbatim} +% Type o = object +% a : longint; +% end; +% \end{verbatim} +% will trigger this error. +parser_object_has_no_vmt=E_L'object $1 n'a pas de table de m‚thodes virtuelles (VMT) +parser_e_illegal_parameter_list=E_Liste de paramŠtres ill‚gale +% You are calling a function with parameters that are of a different type than +% the declared parameters of the function. +parser_e_wrong_parameter_type=E_Mauvais type pour paramŠtre #$1 +% There is an error in the parameter list of the function or procedure. +% The compiler cannot determine the error more accurate than this. +parser_e_wrong_parameter_size=E_Mauvais nombre de paramŠtres sp‚cifi‚ +% There is an error in the parameter list of the function or procedure, +% the number of parameters is not correct. +parser_e_overloaded_no_procedure=E_L'identificateur surcharg‚ $1 n'est pas une fonction +% The compiler encountered a symbol with the same name as an overloaded +% function, but it isn't a function it can overload. +parser_e_overloaded_have_same_parameters=E_Les fonctions surcharg‚es ont les mˆmes paramŠtres +% You're declaring overloaded functions, but with the same parameter list. +% Overloaded function must have at least 1 different parameter in their +% declaration. +parser_e_header_dont_match_forward=E_L'entˆte de la fonction ne correspond pas … la d‚claration $1 +% You declared a function with same parameters but +% different result type or function specifiers. +parser_e_header_different_var_names=E_L'entˆte de la fonction $1 ne correspond pas … la d‚claration : le nom de variable change $2 => $3 +% You declared the function in the \var{interface} part, or with the +% \var{forward} directive, but define it with a different parameter list. +parser_n_duplicate_enum=N_Les valeurs d'une ‚num‚ration doivent ˆtre en ordre ascendant +% \fpc allows enumeration constructions as in C. Given the following +% declaration two declarations: +% \begin{verbatim} +% type a = (A_A,A_B,A_E:=6,A_UAS:=200); +% type a = (A_A,A_B,A_E:=6,A_UAS:=4); +% \end{verbatim} +% The second declaration would produce an error. \var{A\_UAS} needs to have a +% value higher than \var{A\_E}, i.e. at least 7. +parser_n_interface_name_diff_implementation_name=N_Les noms d'interface et d'implementation sont diff‚rents $1 => $2 +% This note warns you if the implementation and interface names of a +% functions are different, but they have the same mangled name. This +% is important when using overloaded functions (but should produce no error). +parser_e_no_with_for_variable_in_other_segments=E_With ne peut ˆtre utilis‚ pour des variables dans un autre segment +% With stores a variable locally on the stack, +% but this is not possible if the variable belongs to another segment. +parser_e_too_much_lexlevel=E_Niveau d'inbrication de fonctions > 31 +% You can nest function definitions only 31 times. +parser_e_range_check_error=E_Erreur d'intervalle dans l'‚valuation d'une constante +% The constants are out of their allowed range. +parser_w_range_check_error=W_Erreur d'intervalle dans l'‚valuation d'une constante +% The constants are out of their allowed range. +parser_e_double_caselabel=E_Valeur en double dans une instruction CASE +% You are specifying the same label 2 times in a \var{case} statement. +parser_e_case_lower_less_than_upper_bound=E_Valeur max inf‚rieure … la valeur min dans CASE +% The upper bound of a \var{case} label is less than the lower bound and this +% is useless +parser_e_type_const_not_possible=E_Les constantes typ‚es de classes sont interdites +% You cannot declare a constant of type class or object. +parser_e_no_overloaded_procvars=E_Impossible d'assigner … une variable fonctionelle une fonction surcharg‚e +% You are trying to assign an overloaded function to a procedural variable. +% This isn't allowed. +parser_e_invalid_string_size=E_La longueur d'une STRING doit ˆtre situ‚e entre 1 et 255 +% The length of a string in Pascal is limited to 255 characters. You are +% trying to declare a string with length lower than 1 or greater than 255 +% (This is not true for \var{Longstrings} and \var{AnsiStrings}. +parser_w_use_extended_syntax_for_objects=W_Utilisez la syntaxe ‚tendue de NEW et DISPOSE pour les objets +% If you have a pointer \var{a} to a class type, then the statement +% \var{new(a)} will not initialize the class (i.e. the constructor isn't +% called), although space will be allocated. you should issue the +% \var{new(a,init)} statement. This will allocate space, and call the +% constructor of the class. +parser_w_no_new_dispose_on_void_pointers=W_L'usage de NEW ou DISPOSE pour des pointeurs non typ‚s est sans signification meaningless +parser_e_no_new_dispose_on_void_pointers=E_L'usage de NEW ou DISPOSE pour des pointeurs non typ‚s est sans signification meaningless +% You cannot use \var{new(p)} or \var{dispose(p)} if \var{p} is an untyped pointer +% because no size is associated to an untyped pointer. +% Accepted for compatibility in \var{tp} and \vat{delphi} modes. +parser_e_class_id_expected=E_Identificateur de classe attendu +% This happens when the compiler scans a procedure declaration that contains +% a dot, +% i.e., a object or class method, but the type in front of the dot is not +% a known type. +parser_e_no_type_not_allowed_here=E_Identificateur de type interdit ici +% You cannot use a type inside an expression. +parser_e_methode_id_expected=E_Identificateur de m‚thode attendu +% This identifier is not a method. +% This happens when the compiler scans a procedure declaration that contains +% a dot, i.e., a object or class method, but the procedure name is not a +% procedure of this type. +parser_e_header_dont_match_any_member=E_La fonction ne correspond … aucune m‚thode de cette classe +% This identifier is not a method. +% This happens when the compiler scans a procedure declaration that contains +% a dot, i.e., a object or class method, but the procedure name is not a +% procedure of this type. +parser_p_procedure_start=P_proc‚dure/fonction $1 +% When using the \var{-vp} switch, the compiler tells you when it starts +% processing a procedure or function implementation. +parser_e_error_in_real=E_Constante r‚elle ill‚gale +% The compiler expects a floating point expression, and gets something else. +parser_e_fail_only_in_constructor=E_FAIL peut uniquement ˆtre utilis‚ dans un constructeur +% You are using the \var{FAIL} instruction outside a constructor method. +parser_e_no_paras_for_destructor=E_Les destructeurs ne peuvent avoir de paramŠtres +% You are declaring a destructor with a parameter list. Destructor methods +% cannot have parameters. +parser_e_only_class_methods_via_class_ref=E_Seules des m‚thodes de classes peuvent ˆtre r‚f‚r‚ avec des r‚f‚rences de classes +% This error occurs in a situation like the following: +% \begin{verbatim} +% Type : +% Tclass = Class of Tobject; +% +% Var C : TClass; +% +% begin +% ... +% C.free +% \end{verbatim} +% \var{Free} is not a class method and hence cannot be called with a class +% reference. +parser_e_only_class_methods=E_Seuls des m‚thodes de classes peuvent ˆtre appel‚s dans une m‚thode de classe +% This is related to the previous error. You cannot call a method of an object +% from a inside a class method. The following code would produce this error: +% \begin{verbatim} +% class procedure tobject.x; +% +% begin +% free +% \end{verbatim} +% Because free is a normal method of a class it cannot be called from a class +% method. +parser_e_case_mismatch=E_La constante et le type de CASE ne conserpodnet pas +% One of the labels is not of the same type as the case variable. +parser_e_illegal_symbol_exported=E_The symbol can't be exported from a library +% You can only export procedures and functions when you write a library. You +% cannot export variables or constants. +parser_w_should_use_override=W_Une m‚thode h‚rit‚e est cach‚e par $1 +% A method that is declared \var{virtual} in a parent class, should be +% overridden in the descendent class with the \var{override} directive. If you +% don't specify the \var{override} directive, you will hide the parent method; +% you will not override it. +parser_e_nothing_to_be_overridden=E_Il n'y a pas de m‚thode dans l'ancˆtre que l'on peut surcharger : $1 +% You try to \var{override} a virtual method of a parent class that doesn't +% exist. +parser_e_no_procedure_to_access_property=E_Il manque un champ pour sp‚cifier l'accŠss … la property +% You specified no \var{read} directive for a property. +parser_w_stored_not_implemented=W_Stored prorperty directive is not yet implemented +% The \var{stored} directive is not yet implemented +parser_e_ill_property_access_sym=E_Symbole ill‚gal pour accŠs … la property +% There is an error in the \var{read} or \var{write} directives for an array +% property. When you declare an array property, you can only access it with +% procedures and functions. The following code woud cause such an error. +% \begin{verbatim} +% tmyobject = class +% i : integer; +% property x [i : integer]: integer read I write i; +% \end{verbatim} +% +parser_e_cant_access_protected_member=E_Cannot access a protected field of an object here +% Fields that are declared in a \var{protected} section of an object or class +% declaration cannot be accessed outside the module wher the object is +% defined, or outside descendent object methods. +parser_e_cant_access_private_member=E_Cannot access a private field of an object here +% Fields that are declared in a \var{private} section of an object or class +% declaration cannot be accessed outside the module where the class is +% defined. +parser_w_overloaded_are_not_both_virtual=W_overloaded method of virtual method should be virtual: $1 +% If you declare overloaded methods in a class, then they should either all be +% virtual, or none. You shouldn't mix them. +parser_w_overloaded_are_not_both_non_virtual=W_overloaded method of non-virtual method should be non-virtual: $1 +% If you declare overloaded methods in a class, then they should either all be +% virtual, or none. You shouldn't mix them. +parser_e_overloaded_methodes_not_same_ret=E_overloaded methods which are virtual must have the same return type: $1 +% If you declare virtual overloaded methods in a class definition, they must +% have the same return type. +parser_e_dont_nest_export=E_EXPORT declared functions can't be nested +% You cannot declare a function or procedure within a function or procedure +% that was declared as an export procedure. +parser_e_methods_dont_be_export=E_methods can't be EXPORTed +% You cannot declare a procedure that is a method for an object as +% \var{export}ed. That is, your methods cannot be called from a C program. +parser_e_call_by_ref_without_typeconv=E_call by var parameters have to match exactly +% When calling a function declared with \var{var} parameters, the variables in +% the function call must be of exactly the same type. There is no automatic +% type conversion. +parser_e_no_super_class=E_Class isn't a parent class of the current class +% When calling inherited methods, you are trying to call a method of a strange +% class. You can only call an inherited method of a parent class. +parser_e_self_not_in_method=E_SELF is only allowed in methods +% You are trying to use the \var{self} parameter outside an object's method. +% Only methods get passed the \var{self} parameters. +parser_e_generic_methods_only_in_methods=E_methods can be only in other methods called direct with type identifier of the class +% A construction like \var{sometype.somemethod} is only allowed in a method. +parser_e_illegal_colon_qualifier=E_Illegal use of ':' +% You are using the format \var{:} (colon) 2 times on an expression that +% is not a real expression. +parser_e_illegal_set_expr=E_range check error in set constructor or duplicate set element +% The declaration of a set contains an error. Either one of the elements is +% outside the range of the set type, either two of the elements are in fact +% the same. +parser_e_pointer_to_class_expected=E_Pointer to object expected +% You specified an illegal type in a \var{New} statement. +% The extended synax of \var{New} needs an object as a parameter. +parser_e_expr_have_to_be_constructor_call=E_Expression must be constructor call +% When using the extended syntax of \var{new}, you must specify the constructor +% method of the object you are trying to create. The procedure you specified +% is not a constructor. +parser_e_expr_have_to_be_destructor_call=E_Expression must be destructor call +% When using the extended syntax of \var{dispose}, you must specify the +% destructor method of the object you are trying to dispose of. +% The procedure you specified is not a destructor. +parser_e_invalid_record_const=E_Illegal order of record elements +% When declaring a constant record, you specified the fields in the wrong +% order. +parser_e_false_with_expr=E_Expression type must be class or record type +% A \var{with} statement needs an argument that is of the type \var{record} +% or \var{class}. You are using \var{with} on an expression that is not of +% this type. +parser_e_void_function=E_Procedures can't return a value +% In \fpc, you can specify a return value for a function when using +% the \var{exit} statement. This error occurs when you try to do this with a +% procedure. Procedures cannot return a value. +parser_e_constructors_always_objects=E_constructors and destructors must be methods +% You're declaring a procedure as destructor or constructor, when the +% procedure isn't a class method. +parser_e_operator_not_overloaded=E_Operator is not overloaded +% You're trying to use an overloaded operator when it isn't overloaded for +% this type. +parser_e_no_reraise_possible=E_Re-raise isn't possible there +% You are trying to raise an exception where it isn't allowed. You can only +% raise exceptions in an \var{except} block. +parser_e_no_new_or_dispose_for_classes=E_The extended syntax of new or dispose isn't allowed for a class +% You cannot generate an instance of a class with the extended syntax of +% \var{new}. The constructor must be used for that. For the same reason, you +% cannot call \var{Dispose} to de-allocate an instance of a class, the +% destructor must be used for that. +parser_e_asm_incomp_with_function_return=E_Assembler incompatible with function return type +% You're trying to implement a \var{assembler} function, but the return type +% of the function doesn't allow that. +parser_e_procedure_overloading_is_off=E_Procedure overloading is switched off +% When using the \var{-So} switch, procedure overloading is switched off. +% Turbo Pascal does not support function overloading. +parser_e_overload_operator_failed=E_It is not possible to overload this operator (overload = instead) +% You are trying to overload an operator which cannot be overloaded. +% The following operators can be overloaded : +% \begin{verbatim} +% +, -, *, /, =, >, <, <=, >=, is, as, in, **, := +% \end{verbatim} +parser_e_comparative_operator_return_boolean=E_Comparative operator must return a boolean value +% When overloading the \var{=} operator, the function must return a boolean +% value. +parser_e_only_virtual_methods_abstract=E_Only virtual methods can be abstract +% You are declaring a method as abstract, when it isn't declared to be +% virtual. +parser_f_unsupported_feature=F_Use of unsupported feature! +% You're trying to force the compiler into doing something it cannot do yet. +parser_e_mix_of_classes_and_objects=E_The mix of CLASSES and OBJECTS isn't allowed +% You cannot derive \var{objects} and \var{classes} intertwined . That is, +% a class cannot have an object as parent and vice versa. +parser_w_unknown_proc_directive_ignored=W_Unknown procedure directive had to be ignored: $1 +% The procedure direcive you secified is unknown. Recognised procedure +% directives are \var{cdecl}, \var{stdcall}, \var{popstack}, \var{pascal} +% \var{register}, \var{export}. +parser_e_absolute_only_one_var=E_absolute can only be associated to ONE variable +% You cannot specify more than one variable before the \var{absolute} directive. +% Thus, the following construct will provide this error: +% \begin{verbatim} +% Var Z : Longint; +% X,Y : Longint absolute Z; +% \end{verbatim} +% \item [ absolute can only be associated a var or const ] +% The address of a \var{absolute} directive can only point to a variable or +% constant. Therefore, the following code will produce this error: +% \begin{verbatim} +% Procedure X; +% +% var p : longint absolute x; +% \end{verbatim} +% +parser_e_absolute_only_to_var_or_const=E_absolute can only be associated a var or const +% The address of a \var{absolute} directive can only point to a variable or +% constant. Therefore, the following code will produce this error: +% \begin{verbatim} +% Procedure X; +% +% var p : longint absolute x; +% \end{verbatim} +% +parser_e_initialized_only_one_var=E_Only ONE variable can be initialized +% You cannot specify more than one variable with a initial value +% in Delphi syntax. +parser_e_abstract_no_definition=E_Abstract methods shouldn't have any definition (with function body) +% Abstract methods can only be declared, you cannot implement them. They +% should be overridden by a descendant class. +parser_e_overloaded_must_be_all_global=E_This overloaded function can't be local (must be exported) +% You are defining a overloaded function in the implementation part of a unit, +% but there is no corresponding declaration in the interface part of the unit. +parser_w_virtual_without_constructor=W_Virtual methods are used without a constructor in $1 +% If you declare objects or classes that contain virtual methods, you need +% to have a constructor and destructor to initialize them. The compiler +% encountered an object or class with virtual methods that doesn't have +% a constructor/destructor pair. +parser_m_macro_defined=M_Macro defined: $1 +% When \var{-vm} is used, the compiler tells you when it defines macros. +parser_m_macro_undefined=M_Macro undefined: $1 +% When \var{-vm} is used, the compiler tells you when it undefines macros. +parser_m_macro_set_to=M_Macro $1 set to $2 +% When \var{-vm} is used, the compiler tells you what values macros get. +parser_i_compiling=I_Compiling $1 +% When you turn on information messages (\var{-vi}), the compiler tells you +% what units it is recompiling. +parser_d_compiling_second_time=D_Compiling $1 for the second time +% When you request debug messages (\var{-vd}) the compiler tells you what +% units it recompiles for the second time. +parser_e_no_paras_allowed=E_Array properties aren't allowed at this point +% You cannot use array properties at that point.a +parser_e_no_property_found_to_override=E_No property found to override +% You want to overrride a property of a parent class, when there is, in fact, +% no such property in the parent class. +parser_e_only_one_default_property=E_Only one default property is allowed, found inherited default property in class $1 +% You specified a property as \var{Default}, but a parent class already has a +% default property, and a class can have only one default property. +parser_e_property_need_paras=E_The default property must be an array property +% Only array properties of classes can be made \var{default} properties. +parser_e_constructor_cannot_be_not_virtual=E_Virtual constructors are only supported in class object model +% You cannot have virtual constructors in objects. You can only have them +% in classes. +parser_e_no_default_property_available=E_No default property available +% You try to access a default property of a class, but this class (or one of +% it's ancestors) doesn't have a default property. +parser_e_cant_have_published=E_The class can't have a published section, use the {$M+} switch +% If you want a \var{published} section in a class definition, you must +% use the \var{\{\$M+\}} switch, whch turns on generation of type +% information. +parser_e_forward_declaration_must_be_resolved=E_Forward declaration of class $1 must be resolved here to use the class as ancestor +% To be able to use an object as an ancestor object, it must be defined +% first. This error occurs in the following situation: +% \begin{verbatim} +% Type ParentClas = Class; +% ChildClass = Class(ParentClass) +% ... +% end; +% \end{verbatim} +% Where \var{ParentClass} is declared but not defined. +parser_e_no_local_operator=E_Local operators not supported +% You cannot overload locally, i.e. inside procedures or function +% definitions. +parser_e_proc_dir_not_allowed_in_interface=E_Procedure directive $1 not allowed in interface section +% This procedure directive is not allowed in the \var{interface} section of +% a unit. You can only use it in the \var{implementation} section. +parser_e_proc_dir_not_allowed_in_implementation=E_Procedure directive $1 not allowed in implementation section +% This procedure directive is not defined in the \var{implementation} section of +% a unit. You can only use it in the \var{interface} section. +parser_e_proc_dir_not_allowed_in_procvar=E_Procedure directive $1 not allowed in procvar declaration +% This procedure directive cannot be part of a procedural of function +% type declaration. +parser_e_function_already_declared_public_forward=E_Function is already declared Public/Forward $1 +% You will get this error if a function is defined as \var{forward} twice. +% Or it is once in the \var{interface} section, and once as a \var{forward} +% declaration in the \var{implmentation} section. +parser_e_not_external_and_export=E_Can't use both EXPORT and EXTERNAL +% These two procedure directives are mutually exclusive +parser_e_name_keyword_expected=E_NAME keyword expected +% The definition of an external variable needs a \var{name} clause. +parser_w_not_supported_for_inline=W_$1 not yet supported inside inline procedure/function +% Inline procedures don't support this declaration. +parser_w_inlining_disabled=W_Inlining disabled +% Inlining of procedures is disabled. +parser_i_writing_browser_log=I_Writing Browser log $1 +% When information messages are on, the compiler warns you when it +% writes the browser log (generated with the \var{\{\$Y+ \}} switch). +parser_h_maybe_deref_caret_missing=H_may be pointer dereference is missing +% The compiler thinks that a pointer may need a dereference. +parser_f_assembler_reader_not_supported=F_Selected assembler reader not supported +% The selected assembler reader (with \var{\{\$ASMMODE xxx\}} is not +% supported. The compiler can be compiled with or without support for a +% particular assembler reader. +parser_e_proc_dir_conflict=E_Procedure directive $1 has conflicts with other directives +% You specified a procedure directive that conflicts with other directives. +% for instance \var{cdecl} and \var{pascal} are mutually exclusive. +parser_e_call_convention_dont_match_forward=E_Calling convention doesn't match forward +% This error happens when you declare a function or procedure with +% e.g. \var{cdecl;} but omit this directive in the implementation, or vice +% versa. The calling convention is part of the function declaration, and +% must be repeated in the function definition. +parser_e_register_calling_not_supported=E_Register calling (fastcall) not supported +% The \var{register} calling convention, i.e., arguments are passed in +% registers instead of on the stack is not supported. Arguments are always +% passed on the stack. +parser_e_property_cant_have_a_default_value=E_Property can't have a default value +% Set properties or indexed properties cannot have a default value. +parser_e_property_default_value_must_const=E_The default value of a property must be constant +% The value of a \var{default} declared property must be knwon at compile +% time. The value you specified is only known at run time. This happens +% .e.g. if you specify a variable name as a default value. +parser_e_cant_publish_that=E_Symbol can't be published, can be only a class +% Only class type variables can be in a \var{published} section of a class +% if they are not declared as a property. +parser_e_cant_publish_that_property=E_That kind of property can't be published +% Properties in a \var{published} section cannot be array properties. +% they must be moved to public sections. Properties in a \var{published} +% section must be an ordinal type, a real type, strings or sets. +parser_w_empty_import_name=W_Empty import name specified +% Both index and name for the import are 0 or empty +parser_e_empty_import_name=W_Empty import name specified +% Some targets need a name for the imported procedure or a cdecl specifier +parser_e_used_proc_name_changed=E_Function internal name changed after use of function +parser_e_division_by_zero=E_Division by zero +% There is a divsion by zero encounted +parser_e_invalid_float_operation=E_Invalid floating point operation +% An operation on two real type values produced an overflow or a division +% by zero. +parser_e_array_lower_less_than_upper_bound=E_Upper bound of range is less than lower bound +% The upper bound of a \var{case} label is less than the lower bound and this +% is not possible +parser_e_string_larger_array=E_string length is larger than array of char length +% The size of the constant string is larger than the size you specified in +% the array[x..y] of char definition +parser_e_ill_msg_expr=E_Illegal expression after message directive +% \fpc supports only integer or string values as message constants +parser_e_ill_msg_param=E_Message handlers can take only one call by ref. parameter +% A method declared with the \var{message}-directive as message handler +% can take only one parameter which must be declared as call by reference +% Parameters are declared as call by reference using the \var{var}-directive +parser_e_duplicate_message_label=E_Duplicate message label: %1 +% A label for a message is used twice in one object/class +parser_e_self_in_non_message_handler=E_Self can be only an explicit parameter in message handlers +% The self parameter can be passed only explicit if it is a method which +% is declared as message method handler +parser_e_threadvars_only_sg=E_Threadvars can be only static or global +% Threadvars must be static or global, you can't declare a thread +% local to a procedure. Local variables are always local to a thread, +% because every thread has it's own stack and local variables +% are stored on the stack +parser_f_direct_assembler_not_allowed=F_Direct assembler not supported for binary output format +% You can't use direct assembler when using a binary writer, choose an +% other outputformat or use an other assembler reader +parser_w_no_objpas_use_mode=W_Don't load OBJPAS unit manual, use {$mode objfpc} or {$mode delphi} instead +% You're trying to load the ObjPas unit manual from a uses clause. This is +% not a good idea to do, you can better use the {$mode objfpc} or {$mode delphi} +% directives which load the unit automaticly +parser_e_no_object_override=E_OVERRIDE can't be used in objects +% Override isn't support for objects, use VIRTUAL instead to override +% a method of an anchestor object +% \end{description} +# +# Type Checking +# +% \section{Type checking errors} +% This section lists all errors that can occur when type checking is +% performed. +% \begin{description} +type_e_mismatch=E_Type mismatch +% This can happen in many cases: +% \begin{itemize} +% \item The variable you're assigning to is of a different type than the +% expression in the assignment. +% \item You are calling a function or procedure with parameters that are +% incompatible with the parameters in the function or procedure definition. +% \end{itemize} +type_e_incompatible_types=E_Incompatible types: got $1 expected $2 +% There is no conversion possible between the two types +type_e_not_equal_types=E_Type mismatch between $1 and $2 +% The types are not equal +type_e_integer_expr_expected=E_Integer expression expected +% The compiler expects an expression of type integer, but gets a different +% type. +type_e_ordinal_expr_expected=E_Ordinal expression expected +% The expression must be of ordinal type, i.e., maximum a \var{Longint}. +% This happens, for instance, when you specify a second argument +% to \var{Inc} or \var{Dec} that doesn't evaluate to an ordinal value. +type_e_type_id_expected=E_Type identifier expected +% The identifier is not a type, or you forgot to supply a type identifier. +type_e_variable_id_expected=E_Variable identifier expected +% This happens when you pass a constant to a \var{Inc} var or \var{Dec} +% procedure. You can only pass variables as arguments to these functions. +type_e_pointer_type_expected=E_pointer type expected +% The variable or expression isn't of the type \var{pointer}. This +% happens when you pass a variable that isn't a pointer to \var{New} +% or \var{Dispose}. +type_e_class_type_expected=E_class type expected +% The variable of expression isn't of the type \var{class}. This happens +% typically when +% \begin{enumerate} +% \item The parent class in a class declaration isn't a class. +% \item An exception handler (\var{On}) contains a type identifier that +% isn't a class. +% \end{enumerate} +type_e_varid_or_typeid_expected=E_Variable or type indentifier expected +% The argument to the \var{High} or \var{Low} function is not a variable +% nor a type identifier. +type_e_cant_eval_constant_expr=E_Can't evaluate constant expression +% No longer in use. +type_e_set_element_are_not_comp=E_Set elements are not compatible +% You are trying to make an operation on two sets, when the set element types +% are not the same. The base type of a set must be the same when taking the +% union +type_e_set_operation_unknown=E_Operation not implemented for sets +% several binary operations are not defined for sets +% like div mod ** (also >= <= for now) +type_w_convert_real_2_comp=W_Automatic type conversion from floating type to COMP which is an integer type +% An implicit type conversion from a real type to a \var{comp} is +% encountered. Since \var{Comp} is a 64 bit integer type, this may indicate +% an error. +type_h_use_div_for_int=H_use DIV instead to get an integer result +% When hints are on, then an integer division with the '/' operator will +% procuce this message, because the result will then be of type real +type_e_strict_var_string_violation=E_string types doesn't match, because of $V+ mode +% When compiling in \var{\{\$V+ \}} mode, the string you pass as a parameter +% should be of the exact same type as the declared parameter of the procedure. +type_e_succ_and_pred_enums_with_assign_not_possible=E_succ or pred on enums with assignments not possible +% When you declared an enumeration type which has assignments in it, as in C, +% like in the following: +% \begin{verbatim} +% Tenum = (a,b,e:=5); +% \end{verbatim} +% you cannot use the \var{Succ} or \var{Pred} functions on them. +type_e_cant_read_write_type=E_Can't read or write variables of this type +% You are trying to \var{read} or \var{write} a variable from or to a +% file of type text, which doesn't support that. Only integer types, +% booleans, reals, pchars and strings can be read from/written to a text file. +type_e_typeconflict_in_set=E_Type conflict between set elements +% There is at least one set element which is of the wrong type, i.e. not of +% the set type. +type_w_maybe_wrong_hi_lo=W_lo/hi(longint/dword) returns the upper/lower word +% \fpc supports an overloaded version of \var{lo/hi} for \var{longint/dword} +% which returns the lower/upper word of the argument. TP always uses +% a 16 bit \var{lo/hi} which returns always bits 0..7 for \var{lo} and the +% bits 8..15 for \var{hi}. If you want the TP behavior you have +% to type case the argument to \var{word/integer} +type_e_integer_or_real_expr_expected=E_Integer or real expression expected +% The first argument to \var{str} must a real or integer type. +type_e_wrong_type_in_array_constructor=E_Wrong type in array constructor +% You are trying to use a type in an array constructor which is not +% allowed. +type_e_wrong_parameter_type=E_Incompatible type for arg #$1: Got $2, expected $3 +% You are trying to pass an invalid type for the specified parameter. +% \end{description} +type_e_no_method_and_procedure_not_compatible=E_Method (variable) and Procedure (variable) are not compatible +% You can't assign a method to a procedure variable or a procedure to a +% method pointer. +% \end{description} +# +# Symtable +# +% \section{Symbol handling} +% This section lists all the messages that concern the handling of symbols. +% This means all things that have to do with procedure and variable names. +% \begin{description} +# +# Symtable +# +% \section{Symbol handling} +% This section lists all the messages that concern the handling of symbols. +% This means all things that have to do with procedure and variable names. +% \begin{description} +sym_e_id_not_found=E_Identifier not found $1 +% The compiler doesn't know this symbol. Usually happens when you misspel +% the name of a variable or procedure, or when you forgot to declare a +% variable. +sym_f_internal_error_in_symtablestack=F_Internal Error in SymTableStack() +% An internal error occurred in the compiler; If you encounter such an error, +% please contact the developers and try to provide an exact description of +% the circumstances in which the error occurs. +sym_e_duplicate_id=E_Duplicate identifier $1 +% The identifier was already declared in the current scope. +sym_h_duplicate_id_where=H_Identifier already defined in $1 at line $2 +% The identifier was already declared in a previous scope. +sym_e_unknown_id=E_Unknown identifier $1 +% The identifier encountered hasn't been declared, or is used outside the +% scope where it's defined. +sym_e_forward_not_resolved=E_Forward declaration not solved $1 +% This can happen in two cases: +% \begin{itemize} +% \item This happens when you declare a function (in the \var{interface} part, or +% with a \var{forward} directive, but do not implement it. +% \item You reference a type which isn't declared in the current \var{type} +% block. +% \end{itemize} +sym_f_id_already_typed=F_Identifier type already defined as type +% You are trying to redefine a type. +sym_e_error_in_type_def=E_Error in type definition +% There is an error in your definition of a new array type: +% \item One of the range delimiters in an array declaration is erroneous. +% For example, \var{Array [1..1.25]} will trigger this error. +sym_e_type_id_not_defined=E_Type identifier not defined +% The type identifier has not been defined yet. +sym_e_forward_type_not_resolved=E_Forward type not resolved $1 +% The compiler encountered an unknown type. +sym_e_only_static_in_static=E_Only static variables can be used in static methods or outside methods +% A static method of an object can only access static variables. +sym_e_invalid_call_tvarsymmangledname=E_Invalid call to tvarsym.mangledname() +% An internal error occurred in the compiler; If you encounter such an error, +% please contact the developers and try to provide an exact description of +% the circumstances in which the error occurs. +sym_f_type_must_be_rec_or_class=F_record or class type expected +% The variable or expression isn't of the type \var{record} or \var{class}. +sym_e_no_instance_of_abstract_object=E_Instances of classes or objects with an abstract method are not allowed +% You are trying to generate an instance of a class which has an abstract +% method that wasn't overridden. +sym_w_label_not_defined=W_Label not defined $1 +% A label was declared, but not defined. +sym_e_ill_label_decl=E_Illegal label declaration +sym_e_goto_and_label_not_supported=E_GOTO und LABEL are not supported (use switch -Sg) +% You must compile a program which has \var{label}s and \var{goto} statements +% with the \var{-Sg} switch. By default, \var{label} and \var{goto} aren't +% supported. +sym_e_label_not_found=E_Label not found +% A \var{goto label} was encountered, but the label isn't declared. +sym_e_id_is_no_label_id=E_identifier isn't a label +% The identifier specified after the \var{goto} isn't of type label. +sym_e_label_already_defined=E_label already defined +% You are defining a label twice. You can define a label only once. +sym_e_ill_type_decl_set=E_illegal type declaration of set elements +% The declaration of a set contains an invalid type definition. +sym_e_class_forward_not_resolved=E_Forward class definition not resolved $1 +% You declared a class, but you didn't implement it. +sym_h_para_identifier_not_used=H_Parameter not used $1 +% This is a warning. The identifier was declared (locally or globally) but +% wasn't used (locally or globally). +sym_n_local_identifier_not_used=N_Local variable not used $1 +% You have declared, but not used a variable in a procedure or function +% implementation. +sym_e_set_expected=E_Set type expected +% The variable or expression isn't of type \var{set}. This happens in an +% \var{in} statement. +sym_w_function_result_not_set=W_Function result does not seem to be set +% You can get this warning if the compiler thinks that a function return +% value is not set. This will not be displayed for assembler procedures, +% or procedures that contain assembler blocks. +sym_e_illegal_field=E_Unknown record field identifier $1 +% The field doesn't exist in the record definition. +sym_n_uninitialized_local_variable=W_Local variable $1 does not seem to be initialized +% This message is displayed if the compiler thinks that a variable will +% be used (i.e. appears in the right-hand-side of an expression) when it +% wasn't initialized first (i.e. appeared in the right-hand side of an +% assigment) +sym_n_uninitialized_variable=W_Variable $1 does not seem to be initialized +% These messages are displayed if the compiler thinks that a variable will +% be used (i.e. appears in the right-hand-side of an expression) when it +% wasn't initialized first (i.e. appeared in the left-hand side of an +% assigment) +sym_e_id_no_member=E_identifier idents no member $1 +% When using the extended syntax of \var{new}, you must specify the constructor +% method of the class you are trying to create. The procedure you specified +% does not exist. +sym_b_param_list=B_Found declaration: $1 +% You get this when you use the \var{-vb} switch. In case an overloaded +% procedure is not found, then all candidate overloaded procedures are +% listed, with their parameter lists. +% \end{description} +# +# Codegenerator +# +% \section{Code generator messages} +% This section lists all messages that can be displayed if the code +% generator encounters an error condition. +% \begin{description} +cg_e_break_not_allowed=E_BREAK not allowed +% You're trying to use \var{break} outside a loop construction. +cg_e_continue_not_allowed=E_CONTINUE not allowed +% You're trying to use \var{continue} outside a loop construction. +cg_e_too_complex_expr=E_Expression too complicated - FPU stack overflow +% Your expression is too long for the compiler. You should try dividing the +% construct over multiple assignments. +cg_e_illegal_expression=E_Illegal expression +% This can occur under many circumstances. Mostly when trying to evaluate +% constant expressions. +cg_e_invalid_integer=E_Invalid integer expression +% You made an expression which isn't an integer, and the compiler expects the +% result to be an integer. +cg_e_invalid_qualifier=E_Illegal qualifier +% One of the following is happening : +% \begin{itemize} +% \item You're trying to access a field of a variable that is not a record. +% \item You're indexing a variable that is not an array. +% \item You're dereferencing a variable that is not a pointer. +% \end{itemize} +cg_e_upper_lower_than_lower=E_High range limit < low range limit +% You are declaring a subrange, and the lower limit is higher than the high +% limit of the range. +cg_e_illegal_count_var=E_Illegal counter variable +% The type of a \var{for} loop variable must be an ordinal type. +% Loop variables cannot be reals or strings. +cg_e_cant_choose_overload_function=E_Can't determine which overloaded function to call +% You're calling overloaded functions with a parameter that doesn't correspond +% to any of the declared function parameter lists. e.g. when you have declared +% a function with parameters \var{word} and \var{longint}, and then you call +% it with a parameter which is of type \var{integer}. +cg_e_parasize_too_big=E_Parameter list size exceeds 65535 bytes +% The I386 processor limits the parameter list to 65535 bytes (the \var{RET} +% instruction causes this) +cg_e_illegal_type_conversion=E_Illegal type conversion +% When doing a type-cast, you must take care that the sizes of the variable and +% the destination type are the same. +cg_d_pointer_to_longint_conv_not_portable=D_Conversion between ordinals and pointers is not portable across platforms +% If you typecast a pointer to a longint, this code will not compile +% on a machine using 64bit for pointer storage. +cg_e_file_must_call_by_reference=E_File types must be var parameters +% You cannot specify files as value parameters, i.e. they must always be +% declared \var{var} parameters. +cg_e_cant_use_far_pointer_there=E_The use of a far pointer isn't allowed there +% Free Pascal doesn't support far pointers, so you cannot take the address of +% an expression which has a far reference as a result. The \var{mem} construct +% has a far reference as a result, so the following code will produce this +% error: +% \begin{verbatim} +% var p : pointer; +% ... +% p:=@mem[a000:000]; +% \end{verbatim} +cg_e_var_must_be_reference=E_illegal call by reference parameters +% You are trying to pass a constant or an expression to a procedure that +% requires a \var{var} parameter. Only variables can be passed as a \var{var} +% parameter. +cg_e_dont_call_exported_direct=E_EXPORT declared functions can't be called +% No longer in use. +cg_w_member_cd_call_from_method=W_Possible illegal call of constructor or destructor (doesn't match to this context) +% No longer in use. +cg_n_inefficient_code=N_Inefficient code +% You construction seems dubious to the compiler. +cg_w_unreachable_code=W_unreachable code +% You specified a loop which will never be executed. Example: +% \begin{verbatim} +% while false do +% begin +% {.. code ...} +% end; +% \end{verbatim} +cg_e_stackframe_with_esp=E_procedure call with stackframe ESP/SP +% The compiler encountered a procedure or function call inside a +% procedure that uses a \var{ESP/SP} stackframe. Normally, when a call is +% done the procedure needs a \var{EBP} stackframe. +cg_e_cant_call_abstract_method=E_Abstract methods can't be called directly +% You cannot call an abstract method directy, instead you must call a +% overriding child method, because an abstract method isn't implemented. +cg_f_internal_error_in_getfloatreg=F_Internal Error in getfloatreg(), allocation failure +% An internal error occurred in the compiler; If you encounter such an error, +% please contact the developers and try to provide an exact description of +% the circumstances in which the error occurs. +cg_f_unknown_float_type=F_Unknown float type +% The compiler cannot determine the kind of float that occurs in an expression. +cg_f_secondvecn_base_defined_twice=F_SecondVecn() base defined twice +% An internal error occurred in the compiler; If you encounter such an error, +% please contact the developers and try to provide an exact description of +% the circumstances in which the error occurs. +cg_f_extended_cg68k_not_supported=F_Extended cg68k not supported +% The var{extended} type is not supported on the m68k platform. +cg_f_32bit_not_supported_in_68000=F_32-bit unsigned not supported in MC68000 mode +% The cardinal is not supported on the m68k platform. +cg_f_internal_error_in_secondinline=F_Internal Error in secondinline() +% An internal error occurred in the compiler; If you encounter such an error, +% please contact the developers and try to provide an exact description of +% the circumstances in which the error occurs. +cg_d_register_weight=D_Register $1 weight $2 $3 +% Debugging message. Shown when the compiler considers a variable for +% keeping in the registers. +cg_e_stacklimit_in_local_routine=E_Stack limit excedeed in local routine +% Your code requires a too big stack. Some operating systems pose limits +% on the stack size. You should use less variables or try ro put large +% variables on the heap. +cg_d_stackframe_omited=D_Stack frame is omitted +% Some procedure/functions do not need a complete stack-frame, so it is omitted. +% This message will be displayed when the {-vd} switch is used. +cg_e_unable_inline_object_methods=E_Object or class methods can't be inline. +% You cannot have inlined object methods. +cg_e_unable_inline_procvar=E_Procvar calls can't be inline. +% A procedure with a procedural variable call cannot be inlined. +cg_e_no_code_for_inline_stored=E_No code for inline procedure stored +% The compiler couldn't store code for the inline procedure. +cg_e_can_access_element_zero=E_Element zero of an ansi/wide- or longstring can't be accessed, use (set)length instead +% You should use \var{setlength} to set the length of an ansi/wide/longstring +% and \var{length} to get the length of such kinf of string +cg_e_include_not_implemented=E_Include and exclude not implemented in this case +% \var{include} and \var{exclude} are only partially +% implemented for \var{i386} processors +% and not at all for \var{m68k} processors. +cg_w_may_wrong_math_argument=W_Probably illegal constant passed to internal math function +% The constant argument passed to a ln or sqrt function is out of +% the definition range of these functions, you may get unexpected +% results when running the program +cg_e_cannot_call_cons_dest_inside_with=E_Constructors or destructors can not be called inside a 'with' clause +% Inside a \var{With} clause you cannot call a constructor or destructor for the +% object you have in the \var{with} clause. +cg_e_cannot_call_message_direct=E_Cannot call message handler method directly +% A message method handler method can't be called directly if it contains an +% explicit self argument +% \end{description} +# EndOfTeX +# +# Assembler reader +# +asmr_d_start_reading=D_Starting $1 styled assembler parsing +asmr_d_finish_reading=D_Finished $1 styled assembler parsing +asmr_e_none_label_contain_at=E_Non-label pattern contains @ +asmr_w_override_op_not_supported=W_Override operator not supported +asmr_e_building_record_offset=E_Error building record offset +asmr_e_offset_without_identifier=E_OFFSET used without identifier +asmr_e_no_local_or_para_allowed=E_Cannot use local variable or parameters here +asmr_e_need_offset=E_need to use OFFSET here +asmr_e_cant_have_multiple_relocatable_symbols=E_Cannot use multiple relocatable symbols +asmr_e_only_add_relocatable_symbol=E_Relocatable symbol can only be added +asmr_e_invalid_constant_expression=E_Invalid constant expression +asmr_e_relocatable_symbol_not_allowed=E_Relocatable symbol is not allowed +asmr_e_invalid_reference_syntax=E_Invalid reference syntax +asmr_e_local_symbol_not_allowed_as_ref=E_Local symbols not allowed as references +asmr_e_wrong_base_index=E_Invalid base and index register usage +asmr_e_wrong_scale_factor=E_Wrong scale factor specified +asmr_e_multiple_index=E_Multiple index register usage +asmr_e_invalid_operand_type=E_Invalid operand type +asmr_e_invalid_string_as_opcode_operand=E_Invalid string as opcode operand: $1 +asmr_w_CODE_and_DATA_not_supported=W_@CODE and @DATA not supported +asmr_e_null_label_ref_not_allowed=E_Null label references are not allowed +asmr_e_ev_zero_divide=F_Divide by zero in asm evaluator +asmr_e_ev_stack_overflow=F_Evaluator stack overflow +asmr_e_ev_stack_underflow=F_Evaluator stack underflow +asmr_e_ev_invalid_number=F_Invalid numeric format in asm evaluator +asmr_e_ev_invalid_op=F_Invalid Operator in asm evaluator +asmr_e_escape_seq_ignored=E_escape sequence ignored: $1 +asmr_e_invalid_symbol_ref=E_Invalid symbol reference +asmr_w_fwait_emu_prob=W_Fwait can cause emulation problems with emu387 +asmr_w_calling_overload_func=W_Calling an overload function in assembler +asmr_e_unsupported_symbol_type=E_Unsupported symbol type for operand +asmr_e_constant_out_of_bounds=E_Constant value out of bounds +asmr_e_error_converting_decimal=E_Error converting decimal $1 +asmr_e_error_converting_octal=E_Error converting octal $1 +asmr_e_error_converting_binary=E_Error converting binary $1 +asmr_e_error_converting_hexadecimal=E_Error converting hexadecimal $1 +asmr_h_direct_global_to_mangled=H_$1 translated to $2 +asmr_w_direct_global_is_overloaded_func=W_$1 is associated to an overloaded function +asmr_e_cannot_use_SELF_outside_a_method=E_Cannot use SELF outside a method +asmr_e_cannot_use_OLDEBP_outside_nested_procedure=E_Cannot use OLDEBP outside a nested procedure +asmr_e_void_function=W_Functions with void return value can't return any value in asm code +asmr_e_SEG_not_supported=E_SEG not supported +asmr_e_size_suffix_and_dest_dont_match=E_Size suffix and destination or source size do not match +asmr_w_size_suffix_and_dest_dont_match=W_Size suffix and destination or source size do not match +asmr_e_syntax_error=E_Assembler syntax error +asmr_e_invalid_opcode_and_operand=E_Invalid combination of opcode and operands +asmr_e_syn_operand=E_Assemler syntax error in operand +asmr_e_syn_constant=E_Assemler syntax error in constant +asmr_e_invalid_string_expression=E_Invalid String expression +asmr_w_const32bit_for_address=32bit constant created for address +asmr_e_invalid_or_missing_opcode=E_Invalid or missing opcode +asmr_e_invalid_prefix_and_opcode=E_Invalid combination of prefix and opcode: $1 +asmr_e_invalid_override_and_opcode=E_Invalid combination of override and opcode: $1 +asmr_e_too_many_operands=E_Too many operands on line +asmr_w_near_ignored=W_NEAR ignored +asmr_w_far_ignored=W_FAR ignored +asmr_e_dup_local_sym=E_Duplicate local symbol $1 +asmr_e_unknown_local_sym=E_Undefined local symbol $1 +asmr_e_unknown_label_identifier=E_Unknown label identifier $1 +asmr_e_invalid_fpu_register=E_Invalid floating point register name +asmr_e_nor_not_supported=E_NOR not supported +asmr_w_modulo_not_supported=W_Modulo not supported +asmr_e_invalid_float_const=E_Invalid floating point constant $1 +asmr_e_invalid_float_expr=E_Invalid floating point expression +asmr_e_wrong_sym_type=E_Wrong symbol type +asmr_e_cannot_index_relative_var=E_Cannot index a local var or parameter with a register +asmr_e_invalid_seg_override=E_Invalid segment override expression +asmr_w_id_supposed_external=W_Identifier $1 supposed external +asmr_e_string_not_allowed_as_const=E_Strings not allowed as constants +asmr_e_no_var_type_specified=No type of variable specified +asmr_w_assembler_code_not_returned_to_text=E_assembler code not returned to text section +asmr_e_not_directive_or_local_symbol=E_Not a directive or local symbol $1 +asmr_w_using_defined_as_local=E_Using a defined name as a local label + +# +# Assembler/binary writers +# +asmw_f_too_many_asm_files=F_Too many assembler files +asmw_f_assembler_output_not_supported=F_Selected assembler output not supported +asmw_f_comp_not_supported=F_Comp not supported +asmw_f_direct_not_supported=F_Direct not support for binary writers +asmw_e_alloc_data_only_in_bss=E_Allocating of data is only allowed in bss section +asmw_f_no_binary_writer_selected=F_No binary writer selected +asmw_e_opcode_not_in_table=E_Asm: Opcode $1 not in table +asmw_e_invalid_opcode_and_operands=E_Asm: $1 invalid combination of opcode and operands +asmw_e_16bit_not_supported=E_Asm: 16 Bit references not supported +asmw_e_invalid_effective_address=E_Asm: Invalid effective address +asmw_e_immediate_or_reference_expected=E_Asm: Immediate or reference expected +asmw_e_value_exceeds_bounds=E_Asm: $1 value exceeds bounds $2 +asmw_e_short_jmp_out_of_range=E_Asm: Short jump is out of range $1 + +# +# Executing linker/assembler +# +exec_w_source_os_redefined=W_Source operating system redefined +exec_i_assembling_pipe=I_Assembling (pipe) $1 +exec_d_cant_create_asmfile=E_Can't create assember file $1 +exec_w_assembler_not_found=W_Assembler $1 not found, switching to external assembling +exec_t_using_assembler=T_Using assembler: $1 +exec_w_error_while_assembling=W_Error while assembling exitcode $1 +exec_w_cant_call_assembler=W_Can't call the assembler, error $1 switching to external assembling +exec_i_assembling=I_Assembling $1 +exec_w_linker_not_found=W_Linker $1 not found, switching to external linking +exec_t_using_linker=T_Using linker: $1 +exec_w_objfile_not_found=W_Object $1 not found, Linking may fail ! +exec_w_libfile_not_found=W_Library $1 not found, Linking may fail ! +exec_w_error_while_linking=W_Error while linking +exec_w_cant_call_linker=W_Can't call the linker, switching to external linking +exec_i_linking=I_Linking $1 +exec_w_binder_not_found=W_binder not found, switching to external binding +exec_w_ar_not_found=W_ar not found, switching to external ar +exec_e_dll_not_supported=E_Dynamic Libraries not supported +exec_i_closing_script=I_Closing script $1 +exec_w_res_not_found=W_resource compiler not found, switching to external mode +exec_i_compilingresource=I_Compiling resource $1 +# +# Executable information +# +execinfo_f_cant_process_executable=F_Can't post process executable $1 +execinfo_f_cant_open_executable=F_Can't open executable $1 +execinfo_x_codesize=X_Size of Code: $1 bytes +execinfo_x_initdatasize=X_Size of initialized data: $1 bytes +execinfo_x_uninitdatasize=X_Size of uninitialized data: $1 bytes +execinfo_x_stackreserve=X_Stack space reserved: $1 bytes +execinfo_x_stackcommit=X_Stack space commited: $1 bytes +# Unit loading +# +# BeginOfTeX +% \section{Unit loading messages.} +% This section lists all messages that can occur when the compiler is +% loading a unit from disk into memory. Many of these mesages are +% informational messages. +% \begin{description} +unit_t_unitsearch=T_Unitsearch: $1 +% When you use the \var{-vt}, the compiler tells you where it tries to find +% unit files. +unit_t_ppu_loading=T_PPU Loading $1 +% When the \var{-vt} switch is used, the compiler tells you +% what units it loads. +unit_u_ppu_name=U_PPU Name: $1 +% When you use the \var{-vu} flag, the unit name is shown. +unit_u_ppu_flags=U_PPU Flags: $1 +% When you use the \var{-vu} flag, the unit flags are shown. +unit_u_ppu_crc=U_PPU Crc: $1 +% When you use the \var{-vu} flag, the unit CRC check is shown. +unit_u_ppu_time=U_PPU Time: $1 +% When you use the \var{-vu} flag, the unit time is shown. +unit_u_ppu_file_too_short=U_PPU File too short +% When you use the \var{-vu} flag, the unit time is shown. +unit_u_ppu_invalid_header=U_PPU Invalid Header (no PPU at the begin) +% A unit file contains as the first three bytes the ascii codes of \var{PPU} +unit_u_ppu_invalid_version=U_PPU Invalid Version $1 +% This unit file was compiled with a different version of the compiler, and +% cannot be read. +unit_u_ppu_invalid_processor=U_PPU is compiled for an other processor +% This unit file was compiled for a different processor type, and +% cannot be read +unit_u_ppu_invalid_target=U_PPU is compiled for an other target +% This unit file was compiled for a different processor type, and +% cannot be read +unit_u_ppu_source=U_PPU Source: $1 +% When you use the \var{-vu} flag, the unit CRC check is shown. +unit_u_ppu_write=U_Writing $1 +% When you specify the \var{-vu} switch, the compiler will tell you where it +% writes the unit file. +unit_f_ppu_cannot_write=F_Can't Write PPU-File +% An err +unit_f_ppu_read_error=F_reading PPU-File +% Unexpected end of file +unit_f_ppu_read_unexpected_end=F_unexpected end of PPU-File +% This means that the unit file was corrupted, and contains invalid +% information. Recompilation will be necessary. +unit_f_ppu_invalid_entry=F_Invalid PPU-File entry: $1 +% The unit the compiler is trying to read is corrupted, or generated with a +% newer version of the compiler. +unit_f_ppu_dbx_count_problem=F_PPU Dbx count problem +% There is an inconsistency in the debugging information of the unit. +unit_e_illegal_unit_name=E_Illegal unit name: $1 +% The name of the unit doesn't match the file name. +unit_f_too_much_units=F_Too much units +% \fpc has a limit of 1024 units in a program. You can change this behavior +% by changing the \var{maxunits} constant in the \file{files.pas} file of the +% compiler, and recompiling the compiler. +unit_f_circular_unit_reference=F_Circular unit reference between $1 and $2 +% Two units are using each other in the interface part. This is only allowed +% in the \var{implementation} part. At least one unit must contain the other one +% in the \var{implementation} section. +unit_f_cant_compile_unit=F_Can't compile unit $1, no sources available +% A unit was found that needs to be recompiled, but no sources are +% available. +unit_w_switch_us_missed=W_Compiling the system unit requires the -Us switch +% When recompiling the system unit (it needs special treatment), the +% \var{-Us} must be specified. +unit_f_errors_in_unit=F_There were $1 errors compiling module, stopping +% When the compiler encounters a fatal error or too many errors in a module +% then it stops with this message. +unit_u_load_unit=U_Load from $1 ($2) unit $3 +% When you use the \var{-vu} flag, which unit is loaded from which unit is +% shown. +unit_u_recompile_crc_change=U_Recompiling $1, checksum changed for $2 +unit_u_recompile_source_found_alone=U_Recompiling $1, source found only +% When you use the \var{-vu} flag, these messages tell you why the current +% unit is recompiled. +unit_u_recompile_staticlib_is_older=U_Recompiling unit, static lib is older than ppufile +% When you use the \var{-vu} flag, the compiler warns if the static library +% of the unit are older than the unit file itself. +unit_u_recompile_sharedlib_is_older=U_Recompiling unit, shared lib is older than ppufile +% When you use the \var{-vu} flag, the compiler warns if the shared library +% of the unit are older than the unit file itself. +unit_u_recompile_obj_and_asm_older=U_Recompiling unit, obj and asm are older than ppufile +% When you use the \var{-vu} flag, the compiler warns if the assembler of +% object file of the unit are older than the unit file itself. +unit_u_recompile_obj_older_than_asm=U_Recompiling unit, obj is older than asm +% When you use the \var{-vu} flag, the compiler warns if the assembler +% file of the unit is older than the object file of the unit. +unit_u_start_parse_interface=U_Parsing interface of $1 +% When you use the \var{-vu} flag, the compiler warns that it starts +% parsing the interface part of the unit +unit_u_start_parse_implementation=U_Parsing implementation of $1 +% When you use the \var{-vu} flag, the compiler warns that it starts +% parsing the implementation part of the unit +unit_u_second_load_unit=U_Second load for unit $1 +% When you use the \var{-vu} flag, the compiler warns that it starts +% recompiling a unit for the second time. This can happend with interdepend +% units. +unit_u_check_time=U_PPU Check file $1 time $2 +% When you use the \var{-vu} flag, the compiler show the filename and +% date and time of the file which a recompile depends on +% \end{description} +# EndOfTeX +# +# Options +# +option_usage=$1 [options] [options] +# BeginOfTeX +% +% \section{Command-line handling errors} +% This section lists errors that occur when the compiler is processing the +% command line or handling the configuration files. +% \begin{description} +option_only_one_source_support=W_Only one source file supported +% You can specify only one source file on the command line. The first +% one will be compiled, others will be ignored. This may indicate that +% you forgot a \var{'-'} sign. +option_def_only_for_os2=W_DEF file can be created only for OS/2 +% This option can only be specified when you're compiling for OS/2 +option_no_nested_response_file=E_nested response files are not supported +% you cannot nest response files with the \var {@file} command-line option. +option_no_source_found=F_No source file name in command line +% The compiler expects a source file name on the command line. +option_illegal_para=E_Illegal parameter: $1 +% You specified an unknown option. +option_help_pages_para=H_-? writes help pages +% When an unknown option is given, this message is diplayed. +option_too_many_cfg_files=F_Too many config files nested +% You can only nest up to 16 config files. +option_unable_open_file=F_Unable to open file $1 +% The option file cannot be found. +option_reading_further_from=N_Reading further options from $1 +% Displayed when you have notes turned on, and the compiler switches +% to another options file. +option_target_is_already_set=W_Target is already set to: $1 +% Displayed if more than one \var{-T} option is specified. +option_no_shared_lib_under_dos=W_Shared libs not supported on DOS platform, reverting to static +% If you specify \var{-CD} for the \dos platform, this message is displayed. +% The compiler supports only static libraries under \dos +option_too_many_ifdef=F_too many IF(N)DEFs +% the \var{\#IF(N)DEF} statements in the options file are not balanced with +% the \var{\#ENDIF} statements. +option_too_many_endif=F_too many ENDIFs +% the \var{\#IF(N)DEF} statements in the options file are not balanced with +% the \var{\#ENDIF} statements. +option_too_less_endif=F_open conditional at the end of the file +% the \var{\#IF(N)DEF} statements in the options file are not balanced with +% the \var{\#ENDIF} statements. +option_no_debug_support=W_Debug information generation is not supported by this executable +% It is possible to have a compiler executable that doesn't support +% the generation of debugging info. If you use such an executable with the +% \var{-g} switch, this warning will be displayed. +option_no_debug_support_recompile_fpc=H_Try recompiling with -dGDB +% It is possible to have a compiler executable that doesn't support +% the generation of debugging info. If you use such an executable with the +% \var{-g} switch, this warning will be displayed. +option_obsolete_switch=W_You are using the obsolete switch $1 +% this warns you when you use a switch that is not needed/supported anymore. +% It is recommended that you remove the switch to overcome problems in the +% future, when the switch meaning may change. +option_obsolete_switch_use_new=W_You are using the obsolete switch $1, please use $2 +% this warns you when you use a switch that is not supported anymore. You +% must now use the second switch instead. +% It is recommended that you change the switch to overcome problems in the +% future, when the switch meaning may change. +% +# EndOfTeX +# +# Logo (option -l) +# +option_switch_bin_to_src_assembler=N_Switching assembler to default source writing assembler +% this notifies you that the assembler has been changed because you used the +% -a switch which can't be used with a binary assembler writer. +%\end{description} +# EndOfTeX +# +# Logo (option -l) +# +option_logo_start=Compilatuer Free Pascal version $FPCVER [$FPCDATE] pour $FPCTARGET +option_logo_end=Copyright (c) 1993-99 by Florian Klaempfl +# +# Info (option -i) +# +option_info_start=Compilatuer Free Pascal version $FPCVER +option_info1= +option_info2=Date du compilateur : $FPCDATE +option_info3=Cible du compilateur : $FPCTARGET +# the next lines are NOT translated on purpose !!! +option_info4= +option_info5=This program comes under the GNU General Public Licence +option_info6=For more information read COPYING.FPC +option_info7= +option_info8=Report bugs,suggestions etc to: +option_info_end= fpc-devel@vekoll.saturnus.vein.hu +# +# Help pages (option -? and -h) +# +# note: the ordering of the enum numbering doens't matter +# +ol_begin=**0*_mettre + aprŠs un bool‚en pour activer l'option, - pour la d‚sactiver +ol001=**1a_conserve les fichiers assembleurs cr‚‚s pendant la compilation +ol002=**2al_liste le code source dans les fichiers assembleur +ol003=**2ar_liste les allocations de registres dans les fichiers assembleur +ol004=**2at_liste les allocations de donn‚es temporaire dans la pile +ol005=**1b_g‚nŠre les informations pour le browser +ol006=**2bl_g‚nŠre les informations locales ‚galement +ol007=**1B_recompile toutes les unit‚s +ol008=**1C_options de g‚n‚ration de code : +ol009=3*2CD_cr‚erune librairie dynamique +ol010=**2Ch_ taille du tas en bytes (entre 1023 et 67107840) +ol011=**2Ci_IO-checking +ol012=**2Cn_pas de linking +ol013=**2Co_g‚nŠre des tests d'overflow pour les op‚rations sur les entiers +ol014=**2Cr_Controle d'intervalles +ol015=**2Cs_sp‚cifie comme taille de la pile +ol016=**2Ct_test de d‚bordement de pile +ol017=3*2CS_cr‚er une librairie statique +ol018=3*2Cx_utiliser le smartlinking +ol019=**1d_d‚finit le symbole +ol020=*O1D_g‚nŠre un fichier DEF +ol021=*O2Dd_assigne la description … +ol022=*O2Dw_application en mode prot‚g‚ +ol023=**1e_d‚finit le chemin vers l'ex‚cutable +ol024=**1E_comme -Cn +ol025=**1F_d‚finit des chemins et noms de fichiers : +ol026=**2FD_d‚finit le r‚pertoire o— chercher les utilitaires de compilation +ol027=**2Fe_redirige les erreurs vers le fichier +ol028=**2FE_r‚pertoire pour les exe/unit‚s : +ol029=**2Fi_ajoute … la liste des r‚pertoires pour fichiers inclus +ol030=**2Fl_ajoute … la liste des r‚pertoires pour librairies +ol031=*L2FL_utilises comme lieur dynamique +ol032=**2Fo_ajoute … la liste des r‚pertoires pour fichiers objets +ol033=**2Fr_charge le fichier erreur +ol034=**2Fu_ajoute … la liste des r‚pertoires pour unit‚s +ol035=**2FU_d‚finit le r‚pertoire d'‚criture des unit‚s … , en d‚pit de -FE +ol036=*g1g_g‚nŠre des informations de d‚bogage : +ol037=*g2gg_utilise gsym +ol038=*g2gd_utilise dbx +ol039=*g2gh_use l'unit‚ de tracage du tas +ol040=**1i_information +ol041=**2iD_donne la date du compilateur +ol042=**2iV_donne la version du compilateur +ol043=**2iSO_donne l'OS du compilateur +ol044=**2iSP_donne le processeur du compilateur +ol045=**2iTO_donne l'OS cible +ol046=**2iTP_donne le processeur cible +ol047=**1I_ajoute … la liste des r‚pertoires pour fichiers inclus +ol048=**1k_transmet au linker +ol049=**1l_‚crit le logo +ol050=**1n_ne pas lire le fichier de configuration par d‚faut +ol051=**1o_change le nom de l'executable en +ol052=**1pg_g‚nŠre du code pour profiler avec gprof +ol053=*L1P_utilise des pipes au lieu de cr‚er des fichiers temporaires +ol054=**1S_options de syntaxe : +ol055=**2S2_autorise quelques extensions Delphi 2 +ol056=**2Sc_autorise les operateurs type C (*=,+=,/= et -=) +ol057=**2Sd_essaye d'ˆtre compatible avec Delphi +ol058=**2Se_stoppe la compilation … la premiŠre erreur +ol059=**2Sg_autorise LABEL et GOTO +ol060=**2Sh_Utilise les ansistrings +ol061=**2Si_supporte les INLINE type C++ +ol062=**2Sm_support des macros comme C (global) +ol063=**2So_essaye d'ˆtre compatible avec TP/BP 7.0 +ol064=**2Sp_essaye d'ˆtre compatible avec GPC +ol065=**2Ss_les constructeurs doivent s'appeler init (et les destructeurs done) +ol066=**2St_autorise "static" dans les objects +ol067=**1s_n'appelle pas l'assembleur ni le linker +ol068=**1u_rend le symbole non d‚fini +ol069=**1U_options d'unit‚s : +ol070=**2Un_ne pas v‚rifier le nom de l'unit‚ +ol071=**2Us_compiler en temps qu'unit‚ systŠme +ol072=**1v_donne des informations. est une combination des lettres suivantes : +ol073=**2*_e : montre les erreurs (d‚faut) d : informations de d‚boggage +ol074=**2*_w : montre les avertissements u : montre les info sur les unit‚s +ol075=**2*_n : montre les notes t : montre les fichiers essay‚s/utilis‚s +ol076=**2*_h : montre les suggestions m : montre les macros d‚finies +ol077=**2*_i : montre des infos g‚n‚rales p : montre les proc‚dures compil‚es +ol078=**2*_l : montre les num‚ros de lignes c : montre les conditionniels +ol079=**2*_a : montre tout 0 : ne montre rien (sauf les erreurs) +ol080=**2*_b : montre toutes les proc‚dures r : mode compatibilit‚ Rhide/GCC +ol081=**2*_ quand une erreur survient x : infos Executable (Win32 seulement) +ol082=**2*_ +ol083=**1X_options pour executable : +ol084=*L2Xc_lien avec librairie C +ol085=**2XD_lien avec la librarie dynamique (d‚finit FPC_LINK_DYNAMIC) +ol086=**2Xs_enlˆve tous les symboles de l'executable +ol087=**2XS_lien avec les librairies statiques (d‚finit FPC_LINK_STATIC) +ol088=**0*_options sp‚cifiques au processeur : +ol089=3*1A_format de sortie : +ol090=3*2Ao_fichier objet g‚n‚r‚ par GNU AS +ol091=3*2Anasmcoff_fichier COFF avec Nasm +ol092=3*2Anasmelf_fichier ELF32 (Linux) avec Nasm +ol093=3*2Anasmobj_fichier OBJ avec Nasm +ol094=3*2Amasm_fichier OBJ avec Masm (Mircosoft) +ol095=3*2Atasm_fichier OBJ avec Tasm (Borland) +ol096=3*1R_type lecture assembleur : +ol097=3*2Ratt_lit l'assembleur AT&T +ol098=3*2Rintel_lit l'assembleur Intel +ol099=3*2Rdirect_copie le texte assembleur directement dans le fichier assembleur +ol100=3*1O_optimisations : +ol101=3*2Og_g‚nŠre du code compact +ol102=3*2OG_g‚nŠre du code rapide (defaut) +ol103=3*2Or_garde certaines variables dans des registres (toujours BUGGY!!!) +ol104=3*2Ou_autorise les optimisations incertaines (voir docs) +ol105=3*2O1_optimisations niveau 1 (optimisations rapides) +ol106=3*2O2_optimisations niveau 2 (-O1 + optimisations plus lentes) +ol107=3*2O3_optimisations niveau 3 (comme -O2u) +ol108=3*2Op_processeur cible : +ol109=3*3Op1_d‚finit 386/486 comme processeur cible +ol110=3*3Op2_d‚finit Pentium/PentiumMMX (tm) comme processeur cycle +ol111=3*3Op3_d‚finit PPro/PII/c6x86/K6 (tm) comme processeur cycle +ol112=3*1T_systŠme d'explioitation cible : +ol113=3*2TGO32V1_version 1 de l'extension DOS de DJ Delorie +ol114=3*2TGO32V2_version 2 de l'extension DOS de DJ Delorie +ol115=3*2TLINUX_Linux +ol116=3*2TOS2_OS/2 2.x +ol117=3*2TWin32_Windows 32 Bits +ol118=6*1A_output format +ol119=6*2Ao_Unix o-file using GNU AS +ol120=6*2Agas_GNU Motorola assembler +ol121=6*2Amit_MIT Syntax (old GAS) +ol122=6*2Amot_Standard Motorola assembler +ol123=6*1O_optimizations: +ol124=6*2Oa_turn on the optimizer +ol125=6*2Og_generate smaller code +ol126=6*2OG_generate faster code (default) +ol127=6*2Ox_optimize maximum (still BUGGY!!!) +ol128=6*2O2_set target processor to a MC68020+ +ol129=6*1R_styles d'assembleur : +ol130=6*2RMOT_lire l'assembleur type motorola +ol131=6*1T_SystŠme d'exploitation cible : +ol132=6*2TAMIGA_Commodore Amiga +ol133=6*2TATARI_Atari ST/STe/TT +ol134=6*2TMACOS_Macintosh m68k +ol135=6*2TLINUX_Linux-68k +ol136=**1*_ +ol137=**1?_affiche cette aide +ol_end=**1h_affiche cette aide sans attente +# +# The End... +# +