# # $Id$ # This file is part of the Free Pascal Compiler # Copyright (c) 1998-2000 by the Free Pascal Development team # # German (alternative) Language File for Free Pascal # # See the file COPYING.FPC, included in this distribution, # for details about the copyright. # # This program is distributed in the hope that it will be useful, # but WITHOUT ANY WARRANTY; without even the implied warranty of # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. # # # The constants are build in the following order: # __ # # is the part of the compiler the message is used # asmr_ assembler parsing # asmw_ assembler writing/binary writers # unit_ unit handling # scan_ scanner # parser_ parser # type_ type checking # general_ general info # exec_ calls to assembler, linker, binder # # the type of the message it should normally used for # f_ fatal error # e_ error # w_ warning # n_ note # h_ hint # i_ info # l_ linenumber # u_ used # t_ tried # m_ macro # p_ procedure # c_ conditional # d_ debug message # b_ display overloaded procedures # x_ executable informations # # # General # # BeginOfTeX % \section{General compiler messages} % This section gives the compiler messages which are not fatal, but which % display useful information. The number of such messages can be % controlled with the various verbosity level \var{-v} switches. % \begin{description} general_t_compilername=01000_T_Compiler: $1 % When the \var{-vt} switch is used, this line tells you what compiler % is used. general_d_sourceos=01001_D_Hostbetriebssystem: $1 % When the \var{-vd} switch is used, this line tells you what the source % operating system is. general_i_targetos=01002_I_Zielbetriebssystem: $1 % When the \var{-vd} switch is used, this line tells you what the target % operating system is. general_t_exepath=01003_T_Der Pfad der ausfhrbaren Datei ist: $1 % When the \var{-vt} switch is used, this line tells you where the compiler % looks for it's binaries. general_t_unitpath=01004_T_Der Unitpfad ist: $1 % When the \var{-vt} switch is used, this line tells you where the compiler % looks for compiled units. You can set this path with the \var{-Fu} general_t_includepath=01005_T_Der Includepfad ist: $1 % When the \var{-vt} switch is used, this line tells you where the compiler % looks for it's include files (files used in \var{\{\$I xxx\}} statements). % You can set this path with the \var{-I} option. general_t_librarypath=01006_T_Der Bibliothekspfad ist: $1 % When the \var{-vt} switch is used, this line tells you where the compiler % looks for the libraries. You can set this path with the \var{-Fl} option. general_t_objectpath=01007_T_Der Objektdateienpfad: $1 % When the \var{-vt} switch is used, this line tells you where the compiler % looks for object files you link in (files used in \var{\{\$L xxx\}} statements). % You can set this path with the \var{-Fo} option. general_i_abslines_compiled=01008_I_$1 Zeilen kompiliert, $2 Sekunden % When the \var{-vi} switch is used, the compiler reports the number % of lines compiled, and the time it took to compile them (real time, % not program time). general_f_no_memory_left=01009_F_Speicher voll % The compiler doesn't have enough memory to compile your program. There are % several remedies for this: % \begin{itemize} % \item If you're using the build option of the compiler, try compiling the % different units manually. % \item If you're compiling a huge program, split it up in units, and compile % these separately. % \item If the previous two don't work, recompile the compiler with a bigger % heap (you can use the \var{-Ch} option for this, \seeo{Ch}) % \end{itemize} general_i_writingresourcefile=01010_I_Resourcestringtabellendatei $1 wird geschrieben % This message is shown when the compiler writes the Resource String Table % file containing all the resource strings for a program. general_e_errorwritingresourcefile=01011_E_Fehler beim Schreiben der Resourcestringtabellendatei: $1 % This message is shown when the compiler encountered an error when writing % the Resource String Table file % \end{description} # # Scanner # % \section{Scanner messages.} % This section lists the messages that the scanner emits. The scanner takes % care of the lexical structure of the pascal file, i.e. it tries to find % reserved words, strings, etc. It also takes care of directives and % conditional compiling handling. % \begin{description} scan_f_end_of_file=02000_F_Unerwartetes Dateiende % this typically happens in one of the following cases : % \begin{itemize} % \item The source file ends before the final \var{end.} statement. This % happens mostly when the \var{begin} and \var{end} statements aren't % balanced; % \item An include file ends in the middle of a statement. % \item A comment wasn't closed. % \end{itemize} scan_f_string_exceeds_line=02001_F_Zeichenkette geht ber Zeilenende hinaus % You forgot probably to include the closing ' in a string, so it occupies % multiple lines. scan_f_illegal_char=02002_F_Unzul„ssiges Zeichen % An illegal character was encountered in the input file. scan_f_syn_expected=02003_F_Syntaxfehler, $1 erwartet aber $2 vorgefunden % This indicates that the compiler expected a different token than % the one you typed. It can occur almost everywhere where you make a % mistake against the pascal language. scan_t_start_include_file=02004_T_Die Include-Datei $1 wird jetzt gelesen % When you provide the \var{-vt} switch, the compiler tells you % when it starts reading an included file. scan_w_comment_level=02005_W_Kommentarschachtelungstiefe $1 gefunden % When the \var{-vw} switch is used, then the compiler warns you if % it finds nested comments. Nested comments are not allowed in Turbo Pascal % and can be a possible source of errors. scan_n_far_directive_ignored=02006_N_$F Direktive (FAR) ignoriert % The \var{FAR} directive is a 16-bit construction which is recorgnised % but ignored by the compiler, since it produces 32 bit code. scan_n_stack_check_global_under_linux=02007_N_Stackprfung ist unter Linux global % Stack checking with the \var{-Cs} switch is ignored under \linux, since % \linux does this for you. Only displayed when \var{-vn} is used. scan_n_ignored_switch=02008_N_Compilerschalter $1 wurde ignoriert % With \var{-vn} on, the compiler warns if it ignores a switch scan_w_illegal_switch=02009_W_Compilerschalter $1 ist ungltig % You included a compiler switch (i.e. \var{\{\$... \}}) which the compiler % doesn't know. scan_w_switch_is_global=02010_W_Dieser Compilerschalter hat globale Auswirkung % When \var{-vw} is used, the compiler warns if a switch is global. scan_e_illegal_char_const=02011_E_Ungltige Char-Konstantante % This happens when you specify a character with its ASCII code, as in % \var{\#96}, but the number is either illegal, or out of range. The range % is 1-255. scan_f_cannot_open_input=02012_F_Datei $1 kann nicht ge”ffnet werden % \fpc cannot find the program or unit source file you specified on the % command line. scan_f_cannot_open_includefile=02013_F_Includedatei $1 kann nicht ge”ffnet werden % \fpc cannot find the source file you specified in a \var{\{\$include ..\}} % statement. scan_e_too_much_endifs=02014_E_Zu viele $ENDIF oder $ELSE Direktiven % Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced. scan_w_only_pack_records=02015_W_Record-Elemente k”nnen nur im Raster 1,2,4 oder 16 Bytes ausgerichtet werden % You are specifying the \var{\{\$PACKRECORDS n\} } with an illegal value for % \var{n}. Only 1,2,4 or 16 are valid in this case. scan_w_only_pack_enum=02016_W_Fr Aufz„hlungen k”nnen nur die Gr”áen 1,2 or 4 Bytes angegeben werden % You are specifying the \var{\{\$PACKENUM n\}} with an illegal value for % \var{n}. Only 1,2 or 4 are valid in this case. scan_e_endif_expected=02017_E_$1 erwartet fr $2 definiert in Zeile $3 % Your conditional compilation statements are unbalanced. scan_e_preproc_syntax_error=02018_E_Syntaxfehler im Argument einer $if Direktive % There is an error in the expression following the \var{\{\$if ..\}} compiler % directive. scan_e_error_in_preproc_expr=02019_E_Syntaxfehler im Kontext einer $if Direktive % There is an error in the expression following the \var{\{\$if ..\}} compiler % directive. scan_w_macro_cut_after_255_chars=02020_W_Inhalt des Makros wurde nach der Auswertung bei 255 Zeichen abgeschnitten % The contents of macros cannot be longer than 255 characters. This is a % safety in the compiler, to prevent buffer overflows. This is shown as a % warning, i.e. when the \var{-vw} switch is used. scan_e_endif_without_if=02021_E_ENDIF ohne IF(N)DEF % Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced. scan_f_user_defined=02022_F_Benutzerdefiniert: $1 % A user defined fatal error occurred. see also the \progref scan_e_user_defined=02023_E_Benutzerdefiniert: $1 % A user defined error occurred. see also the \progref scan_w_user_defined=02024_W_Benutzerdefiniert: $1 % A user defined warning occurred. see also the \progref scan_n_user_defined=02025_N_Benutzerdefiniert: $1 % A user defined note was encountered. see also the \progref scan_h_user_defined=02026_H_Benutzerdefiniert: $1 % A user defined hint was encountered. see also the \progref scan_i_user_defined=02027_I_Benutzerdefiniert: $1 % User defined information was encountered. see also the \progref scan_e_keyword_cant_be_a_macro=02028_E_Ein Makro, welches den selben Namen wie ein Schlsselwort hat, wird ignoriert % You cannot redefine keywords with macros. scan_f_macro_buffer_overflow=02029_F_Makropufferberlauf w„hrend des Lesens oder Expandierens eines Makros % Your macro or it's result was too long for the compiler. scan_w_macro_deep_ten=02030_W_Expansion des Makros berschreitet eine Makroschachtelungstiefe von 16 % When expanding a macro macros have been nested to a level of 16. % The compiler will expand no further, since this may be a sign that % recursion is used. scan_e_wrong_styled_switch=02031_E_Compilerschalter in (* ... *)-Kommentaren sind nicht erlaubt % Compiler switches should always be between \var{\{ \}} comment delimiters. scan_d_handling_switch=02032_D_Bearbeite Schalter "$1" % When you set debugging info on (\var{-vd}) the compiler tells you when it % is evaluating conditional compile statements. scan_c_endif_found=02033_C_ENDIF $1 bearbeitet % When you turn on conditional messages(\var{-vc}), the compiler tells you % where it encounters conditional statements. scan_c_ifdef_found=02034_C_IFDEF $1 bearbeitet, $2 % When you turn on conditional messages(\var{-vc}), the compiler tells you % where it encounters conditional statements. scan_c_ifopt_found=02035_C_IFOPT $1 bearbeitet, $2 % When you turn on conditional messages(\var{-vc}), the compiler tells you % where it encounters conditional statements. scan_c_if_found=02036_C_IF $1 bearbeitet, $2 % When you turn on conditional messages(\var{-vc}), the compiler tells you % where it encounters conditional statements. scan_c_ifndef_found=02037_C_IFNDEF $1 bearbeitet, $2 % When you turn on conditional messages(\var{-vc}), the compiler tells you % where it encounters conditional statements. scan_c_else_found=02038_C_ELSE $1 bearbeitet, $2 % When you turn on conditional messages(\var{-vc}), the compiler tells you % where it encounters conditional statements. scan_c_skipping_until=02039_C_Quelltext wird ignoriert bis... % When you turn on conditional messages(\var{-vc}), the compiler tells you % where it encounters conditional statements, and whether it is skipping or % compiling parts. scan_i_press_enter=02040_I_Drcken Sie um fortzusetzen % When the \var{-vi} switch is used, the compiler stops compilation % and waits for the \var{Enter} key to be pressed when it encounters % a \var{\{\$STOP\}} directive. scan_w_unsupported_switch=02041_W_Nicht untersttzter Schalter $1 % When warings are turned on (\var{-vw}) the compiler warns you about % unsupported switches. This means that the switch is used in Delphi or % Turbo Pascal, but not in \fpc scan_w_illegal_directive=02042_W_Ungltiges Compilerdirektive $1 % When warings are turned on (\var{-vw}) the compiler warns you about % unrecognised switches. For a list of recognised switches, \progref scan_t_back_in=02043_T_Wieder zurck in $1 % When you use (\var{-vt}) the compiler tells you when it has finished % reading an include file. scan_w_unsupported_app_type=02044_W_Nicht untersttzter Anwendungstyp: $1 % You get this warning, ff you specify an unknown application type % with the directive \var{\{\$APPTYPE\}} scan_w_app_type_not_support=02045_W_APPTYPE wird vom Zielbetriebssystem nicht untersttzt % The \var{\{\$APPTYPE\}} directive is supported by win32 applications only. scan_w_decription_not_support=02046_W_DESCRIPTION kann nur bei OS/2- und Windows-Programmen verwendet werden % The \var{\{\$DESCRIPTION\}} directive is only supported for OS2 and Win32 targets. scan_n_version_not_support=02047_N_VERSION wird vom Zielbetriebssystem nicht untersttzt % The \var{\{\$VERSION\}} directive is only supported by win32 target. scan_n_only_exe_version=02048_N_VERSION kann in Units nicht verwendet werden % The \var{\{\$VERSION\}} directive is only used for executable or DLL sources. scan_w_wrong_version_ignored=02049_W_Falsches Format fr VERSION-Directive $1 % The \var{\{\$VERSION\}} directive format is major_version.minor_version % where major_version and minor_version are words. scan_w_unsupported_asmmode_specifier=02050_W_Nicht untersttzter Assemblermodus $1 angegeben % When you specify an assembler mode with the \var{\{\$ASMMODE xxx\}} % the compiler didn't recognize the mode you specified. scan_w_no_asm_reader_switch_inside_asm=02051_W_ASM-Leser-Schalter ist innerhalb einer Asm-Sequenz nicht m”glich, $1 wird erst in der n„chsten Sequenz wirksam % It is not possible to switch from one assembler reader to another % inside an assmebler block. The new reader will be used for next % assembler statement only. scan_e_wrong_switch_toggle=02052_E_Parameter fr Schalter falsch, verwenden Sie ON/OFF oder +/- % You need to use ON or OFF or a + or - to toggle the switch scan_e_resourcefiles_not_supported=02053_E_Resourcedateien werden vom aktuellen Zielbetriebssystem nicht untersttzt % The target you are compiling for doesn't support Resource files. The % only target which can use resource files is Win32 scan_w_include_env_not_found=02054_W_$1 ist keine Umgebungsvariable % The included environment variable can't be found in the environment, it'll % be replaced by an empty string instead. scan_e_invalid_maxfpureg_value=02055_E_Nicht erlaubter Wert fr MAXFPUREGISTER-Direktive % Valid values for this directive are 0..8 and NORMAL/DEFAULT % \end{description} # # Parser # % \section{Parser messages} % This section lists all parser messages. The parser takes care of the % semantics of you language, i.e. it determines if your pascal constructs % are correct. % \begin{description} scan_w_only_one_resourcefile_supported=02056_W_Nur ein Resourcedatei wird vom aktuellen Zielbetriebssystem untersttzt % Only one resource file can be supported for this target - this is the case of % OS/2 (EMX) currently. The first one found is used, the others are discarded. % \end{description} # # Parser # % \section{Parser messages} % This section lists all parser messages. The parser takes care of the % semantics of you language, i.e. it determines if your pascal constructs % are correct. % \begin{description} parser_e_syntax_error=03000_E_Parser - Syntaxfehler % An error against the Turbo Pascal language was encountered. This happens % typically when an illegal character is found in the sources file. parser_w_proc_far_ignored=03001_W_Schlsselwort FAR wurde ignoriert % This is a warning. \var{FAR} is a construct for 8 or 16 bit programs. Since % the compile generates 32 bit programs, it ignores this directive. parser_w_proc_near_ignored=03002_W_Schlsselwort NEAR wurde ignoriert % This is a warning. \var{NEAR} is a construct for 8 or 16 bit programs. Since % the compile generates 32 bit programs, it ignores this directive. parser_w_proc_interrupt_ignored=03003_W_Ignoriere Prozedurtyp INTERRUPT % This is a warning. \var{INTERRUPT} is a i386 specific construct % and is igonred for other processors. parser_e_dont_nest_interrupt=03004_E_INTERRUPT-Prozeduren drfen nicht verschachtelt sein % An \VAR{INTERRUPT} procedure must be global. parser_w_proc_directive_ignored=03005_W_Prozedurtyp $1 wird ignoriert % This is a warning. \var{REGISTER},\var{REINTRODUCE} is ignored by FPC programs for now. % This is introduced first for Delphi compatibility. parser_e_no_overload_for_all_procs=03006_E_Nicht alle Deklarationen von "$1" sind mit OVERLOAD deklariert % When you want to use overloading using the \var{OVERLOAD} directive, then % all declarations need to have \var{OVERLOAD} specified. parser_e_no_dll_file_specified=03007_E_Keine DLL-Datei angegeben % No longer in use. parser_e_export_name_double=03008_E_Doppelter Name fr exportierte Funktion $1 % Exported function names inside a specific DLL must all be different parser_e_export_ordinal_double=03009_E_Doppelter Index fr exportierte Funktion $1 % Exported function names inside a specific DLL must all be different parser_e_export_invalid_index=03010_E_Ungltiger Index for exportierte Funktion % DLL function index must be in the range \var{1..\$FFFF} parser_w_parser_reloc_no_debug=03011_W_Fr relozierbare DLL oder ausfhrbare Datei $1 funktionieren keine Debug-Information, deaktiviert. parser_w_parser_win32_debug_needs_WN=03012_W_Um Win32-Code debuggen zu k”nnen mssen die Relozierungen mit -WN option abgeschaltet werden. % Stabs info is wrong for relocatable DLL or EXES use -WN % if you want to debug win32 executables. parser_e_constructorname_must_be_init=03013_E_Konstruktor-Name muss INIT sein % You are declaring a constructor with a name which isn't \var{init}, and the % \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}). parser_e_destructorname_must_be_done=03014_E_Destruktor-Name muss DONE sein % You are declaring a constructor with a name which isn't \var{done}, and the % \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}). parser_e_illegal_open_parameter=03015_E_Ungltiger Open-Parameter % You are trying to use the wrong type for an open parameter. parser_e_proc_inline_not_supported=03016_E_Schlsselwort INLINE nicht untersttzt % You tried to compile a program with C++ style inlining, and forgot to % specify the \var{-Si} option (\seeo{Si}). The compiler doesn't support C++ % styled inlining by default. parser_w_priv_meth_not_virtual=03017_W_Private Methoden drfen nicht VIRTUAL sein % You declared a method in the private part of a object (class) as % \var{virtual}. This is not allowed. Private methods cannot be overridden % anyway. parser_w_constructor_should_be_public=03018_W_Konstruktor muss PUBLIC sein % Constructors must be in the 'public' part of an object (class) declaration. parser_w_destructor_should_be_public=03019_W_Destruktor muss PUBLIC sein % Destructors must be in the 'public' part of an object (class) declaration. parser_n_only_one_destructor=03020_N_Klasse darf nur einen Destructor besitzen % You can declare only one destructor for a class. parser_e_no_local_objects=03021_E_Lokale Klassendefinitionen sind nicht zul„ssig % Classes must be defined globally. They cannot be defined inside a % procedure or function parser_f_no_anonym_objects=03022_F_Anonyme Klassendefinitionen sind nicht zul„ssig % An invalid object (class) declaration was encountered, i.e. an % object or class without methods that isn't derived from another object or % class. For example: % \begin{verbatim} % Type o = object % a : longint; % end; % \end{verbatim} % will trigger this error. parser_object_has_no_vmt=03023_E_Das Objekt $1 hat keine VMT parser_e_illegal_parameter_list=03024_E_Ungltige Parameterliste % You are calling a function with parameters that are of a different type than % the declared parameters of the function. parser_e_wrong_parameter_type=03025_E_Falscher Parametertyp angegeben fr Argument Nr. $1 % There is an error in the parameter list of the function or procedure. % The compiler cannot determine the error more accurate than this. parser_e_wrong_parameter_size=03026_E_Falsche Parameterzahl angegeben % There is an error in the parameter list of the function or procedure, % the number of parameters is not correct. parser_e_overloaded_no_procedure=03027_E_Bezeichner $1 ist keine Funktion, overload nicht m”glich % The compiler encountered a symbol with the same name as an overloaded % function, but it isn't a function it can overload. parser_e_overloaded_have_same_parameters=03028_E_Overload-Funktion darf nicht eine identische Parameterliste aufweisen % You're declaring overloaded functions, but with the same parameter list. % Overloaded function must have at least 1 different parameter in their % declaration. parser_e_header_dont_match_forward=03029_E_Funktionskopf ist nicht identisch mit Forward-Deklaration $1 % You declared a function with same parameters but % different result type or function specifiers. parser_e_header_different_var_names=03030_E_Funktionskopf von $1 passt nicht zur Forward-Deklaration, Variablename „ndert sich: $2 => $3 % You declared the function in the \var{interface} part, or with the % \var{forward} directive, but define it with a different parameter list. parser_n_duplicate_enum=03031_N_Werte in Aufz„hlungen mssen aufsteigend sein % \fpc allows enumeration constructions as in C. Given the following % declaration two declarations: % \begin{verbatim} % type a = (A_A,A_B,A_E:=6,A_UAS:=200); % type a = (A_A,A_B,A_E:=6,A_UAS:=4); % \end{verbatim} % The second declaration would produce an error. \var{A\_UAS} needs to have a % value higher than \var{A\_E}, i.e. at least 7. parser_n_interface_name_diff_implementation_name=03032_N_Namen in Interface und Implementation sind verschieden! % This note warns you if the implementation and interface names of a % functions are different, but they have the same mangled name. This % is important when using overloaded functions (but should produce no error). parser_e_no_with_for_variable_in_other_segments=03033_E_WITH kann nicht auf Variablen in anderen Segmenten angewendet werden % With stores a variable locally on the stack, % but this is not possible if the variable belongs to another segment. parser_e_too_much_lexlevel=03034_E_Funktionsverschachtelung gr”sser als 31 % You can nest function definitions only 31 times. parser_e_range_check_error=03035_E_Bereichsprfungsfehler bei Konstantenbestimmung % The constants are out of their allowed range. parser_w_range_check_error=03036_W_Bereichsprfungsfehler bei Konstantenbestimmung % The constants are out of their allowed range. parser_e_double_caselabel=03037_E_doppelter CASE-Wert % You are specifying the same label 2 times in a \var{case} statement. parser_e_case_lower_less_than_upper_bound=03038_E_Obere Grenze der CASE-Bereichsangabe ist kleiner als untere Grenze % The upper bound of a \var{case} label is less than the lower bound and this % is useless parser_e_type_const_not_possible=03039_E_Klassen sind als typisierte Konstanten unzul„ssig % You cannot declare a constant of type class or object. parser_e_no_overloaded_procvars=03040_E_Funktionsvariablen von Overload-Funktionen sind unzul„ssig % You are trying to assign an overloaded function to a procedural variable. % This isn't allowed. parser_e_invalid_string_size=03041_E_Stringl„nge muss ein Wert zwischen 1 und 255 sein % The length of a string in Pascal is limited to 255 characters. You are % trying to declare a string with length lower than 1 or greater than 255 % (This is not true for \var{Longstrings} and \var{AnsiStrings}. parser_w_use_extended_syntax_for_objects=03042_W_Benutzen Sie die erweiterte Syntax von NEW und DISPOSE fr Objekt-Instanzen % If you have a pointer \var{a} to a class type, then the statement % \var{new(a)} will not initialize the class (i.e. the constructor isn't % called), although space will be allocated. you should issue the % \var{new(a,init)} statement. This will allocate space, and call the % constructor of the class. parser_w_no_new_dispose_on_void_pointers=03043_W_Verwendung von NEW oder DISPOSE mit untypisierten Pointern ist ohne Aussage parser_e_no_new_dispose_on_void_pointers=03044_E_Verwendung von NEW oder DISPOSE mit untypisierten Pointern ist nicht m”glich % You cannot use \var{new(p)} or \var{dispose(p)} if \var{p} is an untyped pointer % because no size is associated to an untyped pointer. % Accepted for compatibility in \var{tp} and \var{delphi} modes. parser_e_class_id_expected=03045_E_Klassenbezeichner erwartet % This happens when the compiler scans a procedure declaration that contains % a dot, % i.e., a object or class method, but the type in front of the dot is not % a known type. parser_e_no_type_not_allowed_here=03046_E_Typbezeichner ist hier nicht zul„ssig % You cannot use a type inside an expression. parser_e_methode_id_expected=03047_E_Methodenbezeichner erwartet % This identifier is not a method. % This happens when the compiler scans a procedure declaration that contains % a dot, i.e., a object or class method, but the procedure name is not a % procedure of this type. parser_e_header_dont_match_any_member=03048_E_Funktionskopf passt zu keiner Methode der Klasse $1 % This identifier is not a method. % This happens when the compiler scans a procedure declaration that contains % a dot, i.e., a object or class method, but the procedure name is not a % procedure of this type. parser_p_procedure_start=03049_P_Prozedur/Funktion $1 % When using the \var{-vp} switch, the compiler tells you when it starts % processing a procedure or function implementation. parser_e_error_in_real=03050_E_Ungltige Fliesskommakonstante % The compiler expects a floating point expression, and gets something else. parser_e_fail_only_in_constructor=03051_E_FAIL darf nur in Konstruktoren verwendet werden % You are using the \var{FAIL} instruction outside a constructor method. parser_e_no_paras_for_destructor=03052_E_Destruktoren k”nnen keine Parameter haben % You are declaring a destructor with a parameter list. Destructor methods % cannot have parameters. parser_e_only_class_methods_via_class_ref=03053_E_Nur Klassenmethoden k”nnen ber den Klassennamen angesprochen werden % This error occurs in a situation like the following: % \begin{verbatim} % Type : % Tclass = Class of Tobject; % % Var C : TClass; % % begin % ... % C.free % \end{verbatim} % \var{Free} is not a class method and hence cannot be called with a class % reference. parser_e_only_class_methods=03054_E_Nur Klassenmethoden k”nnen in einer Klassenmethode angesprochen werden % This is related to the previous error. You cannot call a method of an object % from a inside a class method. The following code would produce this error: % \begin{verbatim} % class procedure tobject.x; % % begin % free % \end{verbatim} % Because free is a normal method of a class it cannot be called from a class % method. parser_e_case_mismatch=03055_E_Konstante und CASE-Typ passen nicht zueinander % One of the labels is not of the same type as the case variable. parser_e_illegal_symbol_exported=03056_E_Das Symbol kann nicht aus einer Bibliothek exportiert werden % You can only export procedures and functions when you write a library. You % cannot export variables or constants. parser_w_should_use_override=03057_W_Eine Inherit-Methode wird durch $1 verdeckt % A method that is declared \var{virtual} in a parent class, should be % overridden in the descendent class with the \var{override} directive. If you % don't specify the \var{override} directive, you will hide the parent method; % you will not override it. parser_e_nothing_to_be_overridden=03058_E_Es gibt keine Vorg„ngerklasse mit einer Methode, die damit berschrieben werden k”nnte: $1 % You try to \var{override} a virtual method of a parent class that doesn't % exist. parser_e_no_procedure_to_access_property=03059_E_Es gibt keine Member-Funktion um auf diese Property zuzugreifen % You specified no \var{read} directive for a property. parser_w_stored_not_implemented=03060_W_Die Stored Property - Direktive ist noch nicht implementiert % The \var{stored} directive is not yet implemented parser_e_ill_property_access_sym=03061_E_Ungltiges Symbol fr den Zugriff auf die Property % There is an error in the \var{read} or \var{write} directives for an array % property. When you declare an array property, you can only access it with % procedures and functions. The following code woud cause such an error. % \begin{verbatim} % tmyobject = class % i : integer; % property x [i : integer]: integer read I write i; % \end{verbatim} % parser_e_cant_access_protected_member=03062_E_Kann an dieser Stelle nicht auf das geschtzte Feld des Objekts zugreifen % Fields that are declared in a \var{protected} section of an object or class % declaration cannot be accessed outside the module wher the object is % defined, or outside descendent object methods. parser_e_cant_access_private_member=03063_E_Kann an dieser Stelle nicht auf das private Feld des Objekts zugreifen % Fields that are declared in a \var{private} section of an object or class % declaration cannot be accessed outside the module where the class is % defined. parser_w_overloaded_are_not_both_virtual=03064_W_Overload-Methode einer virtuellen Methode muss auch virtuell sein: $1 % If you declare overloaded methods in a class, then they should either all be % virtual, or none. You shouldn't mix them. parser_w_overloaded_are_not_both_non_virtual=03065_W_Overload-Methode einer nicht-virtuellen Methode muss auch nicht-virtuell sein: $1 % If you declare overloaded methods in a class, then they should either all be % virtual, or none. You shouldn't mix them. parser_e_overloaded_methodes_not_same_ret=03066_E_Overload-Methoden, die virtuell sind, mssen den gleichen Rckgabetyp haben: $1 % If you declare virtual overloaded methods in a class definition, they must % have the same return type. parser_e_dont_nest_export=03067_E_Mit EXPORT deklarierte Funktionen drfen nicht verschachtelt sein % You cannot declare a function or procedure within a function or procedure % that was declared as an export procedure. parser_e_methods_dont_be_export=03068_E_Methoden drfen nicht EXPORTiert werden % You cannot declare a procedure that is a method for an object as % \var{export}ed. That is, your methods cannot be called from a C program. parser_e_call_by_ref_without_typeconv=03069_E_Aufrufe mit VAR-Parametern mssen exakt stimmen % When calling a function declared with \var{var} parameters, the variables in % the function call must be of exactly the same type. There is no automatic % type conversion. parser_e_no_super_class=03070_E_Klasse ist keine Elternklasse zur aktuellen Klasse % When calling inherited methods, you are trying to call a method of a strange % class. You can only call an inherited method of a parent class. parser_e_self_not_in_method=03071_E_SELF ist nur in Methoden erlaubt % You are trying to use the \var{self} parameter outside an object's method. % Only methods get passed the \var{self} parameters. parser_e_generic_methods_only_in_methods=03072_E_Methoden drfen nur in anderen Methoden direkt mit dem Klassen-Typbezeichner aufgerufen werden % A construction like \var{sometype.somemethod} is only allowed in a method. parser_e_illegal_colon_qualifier=03073_E_Unzul„ssige Verwendung von ':' % You are using the format \var{:} (colon) 2 times on an expression that % is not a real expression. parser_e_illegal_set_expr=03074_E_Bereichsprfungsfehler im SET-Konstruktor oder doppeltes Set-Element % The declaration of a set contains an error. Either one of the elements is % outside the range of the set type, either two of the elements are in fact % the same. parser_e_pointer_to_class_expected=03075_E_Zeiger auf Objekt erwartet % You specified an illegal type in a \var{New} statement. % The extended synax of \var{New} needs an object as a parameter. parser_e_expr_have_to_be_constructor_call=03076_E_Ausdruck muss ein Konstruktor-Aufruf sein % When using the extended syntax of \var{new}, you must specify the constructor % method of the object you are trying to create. The procedure you specified % is not a constructor. parser_e_expr_have_to_be_destructor_call=03077_E_Ausdruck muss ein Destruktor-Aufruf sein % When using the extended syntax of \var{dispose}, you must specify the % destructor method of the object you are trying to dispose of. % The procedure you specified is not a destructor. parser_e_invalid_record_const=03078_E_Unzul„ssige Reihenfolge der Record-Elemente % When declaring a constant record, you specified the fields in the wrong % order. parser_e_false_with_expr=03079_E_Typ des Ausdrucks muss eine Klasse oder ein Recordtyp sein % A \var{with} statement needs an argument that is of the type \var{record} % or \var{class}. You are using \var{with} on an expression that is not of % this type. parser_e_void_function=03080_E_Prozeduren k”nnen keinen Wert zurckliefern % In \fpc, you can specify a return value for a function when using % the \var{exit} statement. This error occurs when you try to do this with a % procedure. Procedures cannot return a value. parser_e_constructors_always_objects=03081_E_Konstruktoren und Destruktoren mssen Methoden sein % You're declaring a procedure as destructor or constructor, when the % procedure isn't a class method. parser_e_operator_not_overloaded=03082_E_Operator besitzt kein Overload % You're trying to use an overloaded operator when it isn't overloaded for % this type. parser_e_no_such_assignment=03083_E_Es ist nicht m”glich, die Zuweisung fr gleiche Typen zu berladen % You can not overload assignment for types % that the compiler considers as equal. parser_e_overload_impossible=03084_E_Unm”gliche Operator-.berladung % The combination of operator, arguments and return type are % incompatible. parser_e_no_reraise_possible=03085_E_Ausl”sen einer Exception an dieser Stelle nicht m”glich % You are trying to raise an exception where it isn't allowed. You can only % raise exceptions in an \var{except} block. parser_e_no_new_or_dispose_for_classes=03086_E_Die erweiterte Syntax von New oder Dispose ist fr Klassen unzul„ssig % You cannot generate an instance of a class with the extended syntax of % \var{new}. The constructor must be used for that. For the same reason, you % cannot call \var{Dispose} to de-allocate an instance of a class, the % destructor must be used for that. parser_e_asm_incomp_with_function_return=03087_E_Assembler-Funktion nicht mit diesem Rckgabetyp m”glich % You're trying to implement a \var{assembler} function, but the return type % of the function doesn't allow that. parser_e_procedure_overloading_is_off=03088_E_Das šberladen von Prozeduren ist ausgeschaltet % When using the \var{-So} switch, procedure overloading is switched off. % Turbo Pascal does not support function overloading. parser_e_overload_operator_failed=03089_E_Es ist nicht m”glich, dieesen Operator zu berladen (benutzen Sie stattdessen '=') % You are trying to overload an operator which cannot be overloaded. % The following operators can be overloaded : % \begin{verbatim} % +, -, *, /, =, >, <, <=, >=, is, as, in, **, := % \end{verbatim} parser_e_comparative_operator_return_boolean=03090_E_Vergleichsoperator muss einen booleschen Wert zurckgeben % When overloading the \var{=} operator, the function must return a boolean % value. parser_e_only_virtual_methods_abstract=03091_E_Nur virtuelle Methoden k”nnen abstrakt sein % You are declaring a method as abstract, when it isn't declared to be % virtual. parser_f_unsupported_feature=03092_F_Benutzung einer nicht untersttzten Erweiterung! % You're trying to force the compiler into doing something it cannot do yet. parser_e_mix_of_classes_and_objects=03093_E_Das Mischen von Klassen und Objekten ist unzul„ssig % You cannot derive \var{objects} and \var{classes} intertwined . That is, % a class cannot have an object as parent and vice versa. parser_w_unknown_proc_directive_ignored=03094_W_Unbekannte Prozedur, Direktive $1 wurde ignoriert % The procedure direcive you secified is unknown. Recognised procedure % directives are \var{cdecl}, \var{stdcall}, \var{popstack}, \var{pascal} % \var{register}, \var{export}. parser_e_absolute_only_one_var=03095_E_ABSOLUTE kann nur auf eine alleinstehende Variable angewendet werden % You cannot specify more than one variable before the \var{absolute} directive. % Thus, the following construct will provide this error: % \begin{verbatim} % Var Z : Longint; % X,Y : Longint absolute Z; % \end{verbatim} % \begin{itemize} % \item [ absolute can only be associated a var or const ] % \end{itemize} % The address of a \var{absolute} directive can only point to a variable or % constant. Therefore, the following code will produce this error: % \begin{verbatim} % Procedure X; % % var p : longint absolute x; % \end{verbatim} % parser_e_absolute_only_to_var_or_const=03096_E_ABSOLUTE kann nur auf Variablen und Konstanten angewendet werden % The address of a \var{absolute} directive can only point to a variable or % constant. Therefore, the following code will produce this error: % \begin{verbatim} % Procedure X; % % var p : longint absolute x; % \end{verbatim} % parser_e_initialized_only_one_var=03097_E_Es kann nur EINE Variable initialisiert werden % You cannot specify more than one variable with a initial value % in Delphi syntax. parser_e_abstract_no_definition=03098_E_Abstrakte Methoden drfen keine Definition (mit Rumpf) haben % Abstract methods can only be declared, you cannot implement them. They % should be overridden by a descendant class. parser_e_overloaded_must_be_all_global=03099_E_Diese berladene Funktion darf nicht lokal sein (muss Exportiert werden) % You are defining a overloaded function in the implementation part of a unit, % but there is no corresponding declaration in the interface part of the unit. parser_w_virtual_without_constructor=03100_W_Virtuelle Methoden wurden ohne Konstruktor verwendet in $1 % If you declare objects or classes that contain virtual methods, you need % to have a constructor and destructor to initialize them. The compiler % encountered an object or class with virtual methods that doesn't have % a constructor/destructor pair. parser_m_macro_defined=03101_M_Makro definiert: $1 % When \var{-vm} is used, the compiler tells you when it defines macros. parser_m_macro_undefined=03102_M_Makro gel”scht: $1 % When \var{-vm} is used, the compiler tells you when it undefines macros. parser_m_macro_set_to=03103_M_Makro $1 auf $2 gesetzt % When \var{-vm} is used, the compiler tells you what values macros get. parser_i_compiling=03104_I_Kompiliere $1 % When you turn on information messages (\var{-vi}), the compiler tells you % what units it is recompiling. parser_u_parsing_interface=03105_U_Parse Interface von Unit $1 % This tells you that the reading of the interface % of the current unit starts parser_u_parsing_implementation=03106_U_Parse Implementation von $1 % This tells you that the code reading of the implementation % of the current unit, library or program starts parser_d_compiling_second_time=03107_D_Kompiliere $1 zum zweiten Mal % When you request debug messages (\var{-vd}) the compiler tells you what % units it recompiles for the second time. parser_e_no_paras_allowed=03108_E_Array-Eigenschaften sind an dieser Stelle nicht erlaubt % You cannot use array properties at that point. parser_e_no_property_found_to_override=03109_E_Es gibt keine Property diesen Namens, die berschrieben werden k”nnte % You want to overrride a property of a parent class, when there is, in fact, % no such property in the parent class. parser_e_only_one_default_property=03110_E_Es ist nur eine einzelne Default-Property erlaubt, vererbte Default-Property in Klasse $1 gefunden % You specified a property as \var{Default}, but a parent class already has a % default property, and a class can have only one default property. parser_e_property_need_paras=03111_E_Die Default-Property muss eine Array-Property sein % Only array properties of classes can be made \var{default} properties. parser_e_constructor_cannot_be_not_virtual=03112_E_Virtuelle Konstruktoren werden nur im Klassen-Objektmodell untersttzt % You cannot have virtual constructors in objects. You can only have them % in classes. parser_e_no_default_property_available=03113_E_Keine Default-Property verfgbar % You try to access a default property of a class, but this class (or one of % it's ancestors) doesn't have a default property. parser_e_cant_have_published=03114_E_Die Klasse kann keinen PUBLISHED Bereich haben, benutzen Sie den {$M+} Schalter % If you want a \var{published} section in a class definition, you must % use the \var{\{\$M+\}} switch, whch turns on generation of type % information. parser_e_forward_declaration_must_be_resolved=03115_E_Forward-Deklaration der Klasse $1 muss hier aufgel”st werden, wenn sie als Elternklasse benutzt werden soll % To be able to use an object as an ancestor object, it must be defined % first. This error occurs in the following situation: % \begin{verbatim} % Type ParentClas = Class; % ChildClass = Class(ParentClass) % ... % end; % \end{verbatim} % Where \var{ParentClass} is declared but not defined. parser_e_no_local_operator=03116_E_Lokale Operatoren werden nicht untersttzt % You cannot overload locally, i.e. inside procedures or function % definitions. parser_e_proc_dir_not_allowed_in_interface=03117_E_Prozedur-Direktive $1 unzul„ssig im Interface-Bereich % This procedure directive is not allowed in the \var{interface} section of % a unit. You can only use it in the \var{implementation} section. parser_e_proc_dir_not_allowed_in_implementation=03118_E_Prozedur Direktive $1 unzul„ssig im Implementation-Bereich % This procedure directive is not defined in the \var{implementation} section of % a unit. You can only use it in the \var{interface} section. parser_e_proc_dir_not_allowed_in_procvar=03119_E_Prozedur-Direktive $1 unzul„ssig in einer Procvar-Deklaration % This procedure directive cannot be part of a procedural of function % type declaration. parser_e_function_already_declared_public_forward=03120_E_Funktion ist bereits als Public oder Forward deklariert: $1 % You will get this error if a function is defined as \var{forward} twice. % Or it is once in the \var{interface} section, and once as a \var{forward} % declaration in the \var{implmentation} section. parser_e_not_external_and_export=03121_E_Kann nicht EXPORT und EXTERNAL gleichzeitig benutzen % These two procedure directives are mutually exclusive parser_e_name_keyword_expected=03122_E_Schlsselwort NAME erwartet % The definition of an external variable needs a \var{name} clause. parser_w_not_supported_for_inline=03123_W_$1 noch nicht innerhalb von inline Prozeduren/Funktionen untersttzt % Inline procedures don't support this declaration. parser_w_inlining_disabled=03124_W_Inlining deaktiviert % Inlining of procedures is disabled. parser_i_writing_browser_log=03125_I_Schreibe Browser-Log $1 % When information messages are on, the compiler warns you when it % writes the browser log (generated with the \var{\{\$Y+\}} switch). parser_h_maybe_deref_caret_missing=03126_H_M”glicherweise fehlt eine Zeiger-Dereferenzierung % The compiler thinks that a pointer may need a dereference. parser_f_assembler_reader_not_supported=03127_F_Gew„hlter Assembler-Leser nicht untersttzt % The selected assembler reader (with \var{\{\$ASMMODE xxx\}} is not % supported. The compiler can be compiled with or without support for a % particular assembler reader. parser_e_proc_dir_conflict=03128_E_Prozedur-Direktive $1 steht in Konflikt mit anderen Direktiven % You specified a procedure directive that conflicts with other directives. % for instance \var{cdecl} and \var{pascal} are mutually exclusive. parser_e_call_convention_dont_match_forward=03129_E_Aufrufkonvention passt nicht zur Forward-Deklaration % This error happens when you declare a function or procedure with % e.g. \var{cdecl;} but omit this directive in the implementation, or vice % versa. The calling convention is part of the function declaration, and % must be repeated in the function definition. parser_e_register_calling_not_supported=03130_E_Register-Aufrufkonvention (fastcall) nicht untersttzt % The \var{register} calling convention, i.e., arguments are passed in % registers instead of on the stack is not supported. Arguments are always % passed on the stack. parser_e_property_cant_have_a_default_value=03131_E_Property kann keinen Vorgabewert haben % Set properties or indexed properties cannot have a default value. parser_e_property_default_value_must_const=03132_E_Der Vorgabewert einer Property muss eine Konstante sein % The value of a \var{default} declared property must be known at compile % time. The value you specified is only known at run time. This happens % .e.g. if you specify a variable name as a default value. parser_e_cant_publish_that=03133_E_Symbol darf nicht PUBLISHED sein, dies kann nur eine Klasse sein % Only class type variables can be in a \var{published} section of a class % if they are not declared as a property. parser_e_cant_publish_that_property=03134_E_Diese Property-Art kann nicht Published sein % Properties in a \var{published} section cannot be array properties. % they must be moved to public sections. Properties in a \var{published} % section must be an ordinal type, a real type, strings or sets. parser_w_empty_import_name=03135_W_Leerer Importname angegeben % Both index and name for the import are 0 or empty parser_e_empty_import_name=03136_W_Leerer Importname angegeben % Some targets need a name for the imported procedure or a cdecl specifier parser_e_used_proc_name_changed=03137_E_Funktionsinterner Name hat sich nach der Verwendung einer Funktion ge„ndert % This is an internal error; please report any occurrences of this error % to the \fpc team. parser_e_division_by_zero=03138_E_Division durch Null % There is a divsion by zero encounted parser_e_invalid_float_operation=03139_E_Ungltige Fliesskomma-Operation % An operation on two real type values produced an overflow or a division % by zero. parser_e_array_lower_less_than_upper_bound=03140_E_Obere Grenze des Bereichs ist kleiner als die untere Grenze % The upper bound of a \var{case} label is less than the lower bound and this % is not possible parser_w_string_too_long=03141_W_String "$1" ist l„nger als $2 % The size of the constant string is larger than the size you specified in % string type definition parser_e_string_larger_array=03142_E_Stringl„nge ist gr”sser als die L„nge des "array of char" % The size of the constant string is larger than the size you specified in % the array[x..y] of char definition parser_e_ill_msg_expr=03143_E_Ungltiger Ausdruck nach der 'Message'-Direktive % \fpc supports only integer or string values as message constants parser_e_ill_msg_param=03144_E_Message-Handler akzeptieren nur einen "Call by Reference" Parameter % A method declared with the \var{message}-directive as message handler % can take only one parameter which must be declared as call by reference % Parameters are declared as call by reference using the \var{var}-directive parser_e_duplicate_message_label=03145_E_Doppeltes Message-Label: $1 % A label for a message is used twice in one object/class parser_e_self_in_non_message_handler=03146_E_SELF darf nur in Message-Handlern ein expliziter Parameter sein % The self parameter can be passed only explicit if it is a method which % is declared as message method handler parser_e_threadvars_only_sg=03147_E_Threadvariablen k”nnen nur statisch oder global sein % Threadvars must be static or global, you can't declare a thread % local to a procedure. Local variables are always local to a thread, % because every thread has it's own stack and local variables % are stored on the stack parser_f_direct_assembler_not_allowed=03148_F_Direkter Assembler wird f+r bin„res Ausgabeformat nicht untersttzt % You can't use direct assembler when using a binary writer, choose an % other outputformat or use an other assembler reader parser_w_no_objpas_use_mode=03149_W_Laden Sie die OBJPAS Unit nicht manuell, benutzen Sie statdessen {$mode objfpc} oder {$mode delphi} % You're trying to load the ObjPas unit manual from a uses clause. This is % not a good idea to do, you can better use the \var{\{\$mode objfpc\}} or % \var{\{\$mode delphi\}} % directives which load the unit automaticly parser_e_no_object_override=03150_E_OVERRIDE darf in Objekten nicht verwendet werden % Override isn't support for objects, use VIRTUAL instead to override % a method of an anchestor object parser_e_cant_use_inittable_here=03151_E_Datentypen, die ein Initialiserung oder Finalisierung ben”tigen, k”nnen in varianten Records nicht verwendet werden % Some data type (e.g. \var{ansistring}) needs initialization/finalization % code which is implicitly generated by the compiler. Such data types % can't be used in the variant part of a record. parser_e_resourcestring_only_sg=03152_E_Resourcestrings drfen nur statisch oder global sein % Resourcestring can not be declared local, only global or using the static % directive. parser_e_exit_with_argument_not__possible=03153_E_EXIT mit Argument darf hier nicht verwendet werden % an exit statement with an argument for the return value can't be used here, this % can happen e.g. in \var{try..except} or \var{try..finally} blocks parser_e_stored_property_must_be_boolean=03154_E_Der Typ des STORED-Symbols muss boolesch sein % If you specify a storage symbol in a property declaration, it must be of % the type boolean parser_e_ill_property_storage_sym=03155_E_Dieses Symbol ist als Speichersymbol unzul„ssig % You can't use this type of symbol as storage specifier in property % declaration. You can use only methods with the result type boolean, % boolean class fields or boolean constants parser_e_only_publishable_classes_can__be_published=03156_E_Nur Klassen, die im "$M+"-Modus kompiliert wurden, drfen published sein % In the published section of a class can be only class as fields used which % are compiled in $M+ or which are derived from such a class. Normally % such a class should be derived from TPersitent parser_e_proc_directive_expected=03157_E_Prozedurdirektive erwartet % When declaring a procedure in a const block you used a ; after the % procedure declaration after which a procedure directive must follow. % Correct declarations are: % \begin{verbatim} % const % p : procedure;stdcall=nil; % p : procedure stdcall=nil; % \end{verbatim} parser_e_invalid_property_index_value=03158_E_Der Wert fr einen Property-Index muss ordinalen Typs sein % The value you use to index a property must be of an ordinal type, for % example an integer or enumerated type. parser_e_procname_to_short_for_export=03159_E_Prozedurname zu kurz um exportiert zu werden % The length of the procedure/function name must be at least 2 characters % long. This is because of a bug in dlltool which doesn't parse the .def % file correct with a name of length 1. parser_e_dlltool_unit_var_problem=03160_E_Es kann kein DEFFILE-Eintrag fr unit-globale Variablen erzeugt werden parser_e_dlltool_unit_var_problem2=03161_E_Kompiliere ohne "-WD"-Option # # Type Checking # % \section{Type checking errors} % This section lists all errors that can occur when type checking is % performed. % \begin{description} type_e_mismatch=04000_E_Typen passen nicht zusammen % This can happen in many cases: % \begin{itemize} % \item The variable you're assigning to is of a different type than the % expression in the assignment. % \item You are calling a function or procedure with parameters that are % incompatible with the parameters in the function or procedure definition. % \end{itemize} type_e_incompatible_types=04001_E_Inkompatible Typen: Habe "$1" erhalten, aber "$2" erwartet % There is no conversion possible between the two types % Another possiblity is that they are declared in different % declarations: % \begin{verbatim} % Var % A1 : Array[1..10] Of Integer; % A2 : Array[1..10] Of Integer; % % Begin % A1:=A2; { This statement gives also this error, it % is due the strict type checking of pascal } % End. % \end{verbatim} type_e_not_equal_types=04002_E_Typen sind verschieden bei $1 und $2 % The types are not equal type_e_type_id_expected=04003_E_Typbezeichner erwartet % The identifier is not a type, or you forgot to supply a type identifier. type_e_variable_id_expected=04004_E_Variablenbezeichner erwartet % This happens when you pass a constant to a \var{Inc} var or \var{Dec} % procedure. You can only pass variables as arguments to these functions. type_e_integer_expr_expected=04005_E_Integer-Ausdruck erwartet, aber "$1" erhalten % The compiler expects an expression of type integer, but gets a different % type. type_e_boolean_expr_expected=04006_E_Booleschen Ausdruck erwartet, aber "$1" erhalten % The expression must be a boolean type, it should be return true or % false. type_e_ordinal_expr_expected=04007_E_Ganzahligen Ausdruck erwartet % The expression must be of ordinal type, i.e., maximum a \var{Longint}. % This happens, for instance, when you specify a second argument % to \var{Inc} or \var{Dec} that doesn't evaluate to an ordinal value. type_e_pointer_type_expected=04008_E_Zeigertyp erwartet, aber "$1" erhalten % The variable or expression isn't of the type \var{pointer}. This % happens when you pass a variable that isn't a pointer to \var{New} % or \var{Dispose}. type_e_class_type_expected=04009_E_Klassentyp erwartet, aber "$1" erhalten % The variable of expression isn't of the type \var{class}. This happens % typically when % \begin{enumerate} % \item The parent class in a class declaration isn't a class. % \item An exception handler (\var{On}) contains a type identifier that % isn't a class. % \end{enumerate} type_e_varid_or_typeid_expected=04010_E_Variable oder Typbezeichner erwartet % The argument to the \var{High} or \var{Low} function is not a variable % nor a type identifier. type_e_cant_eval_constant_expr=04011_E_Kann konstanten Ausdruck nicht auswerten % No longer in use. type_e_set_element_are_not_comp=04012_E_Set-Elemente sind nicht kompatibel % You are trying to make an operation on two sets, when the set element types % are not the same. The base type of a set must be the same when taking the % union type_e_set_operation_unknown=04013_E_Operation fr Sets nicht implementiert % several binary operations are not defined for sets % like div mod ** (also >= <= for now) type_w_convert_real_2_comp=04014_W_Automatische Typumwandlung von Fliesskommatyp nach COMP (=integer mit 64 bit) % An implicit type conversion from a real type to a \var{comp} is % encountered. Since \var{Comp} is a 64 bit integer type, this may indicate % an error. type_h_use_div_for_int=04015_H_Verwenden sie DIV um ein Integer-Ergebnis zu erhalten % When hints are on, then an integer division with the '/' operator will % procuce this message, because the result will then be of type real type_e_strict_var_string_violation=04016_E_Stringtypen passen nicht zueinander, da in "$V+"-Modus % When compiling in \var{\{\$V+\}} mode, the string you pass as a parameter % should be of the exact same type as the declared parameter of the procedure. type_e_succ_and_pred_enums_with_assign_not_possible=04017_E_Succ oder Pred kann nicht auf Aufz„hlungen mit Zuweisungen angewendet werden % When you declared an enumeration type which has assignments in it, as in C, % like in the following: % \begin{verbatim} % Tenum = (a,b,e:=5); % \end{verbatim} % you cannot use the \var{Succ} or \var{Pred} functions on them. type_e_cant_read_write_type=04018_E_Kann Variablen dieses Typs nicht lesen oder schreiben % You are trying to \var{read} or \var{write} a variable from or to a % file of type text, which doesn't support that. Only integer types, % booleans, reals, pchars and strings can be read from/written to a text file. type_e_no_readln_writeln_for_typed_file=04019_E_Kann ReadLn und WriteLn nicht bei typisierten Dateien verwenden % \var{readln} and \var{writeln} are only allowed for text files. type_e_no_read_write_for_untyped_file=04020_E_Kann Read und Write nicht bei untypisierten Dateien verwenden % \var{read} and \var{write} are only allowed for text or typed files. type_e_typeconflict_in_set=04021_E_Typkonflikt zwischen den Elementen des Sets % There is at least one set element which is of the wrong type, i.e. not of % the set type. type_w_maybe_wrong_hi_lo=04022_W_lo/hi(dword/qword) gibt oberes/unteres Word/DWord zurck % \fpc supports an overloaded version of \var{lo/hi} for \var{longint/dword/int64/qword} % which returns the lower/upper word of the argument. TP always uses % a 16 bit \var{lo/hi} which returns always bits 0..7 for \var{lo} and the % bits 8..15 for \var{hi}. If you want the TP behavior you have % to type case the argument to \var{word/integer} type_e_integer_or_real_expr_expected=04023_E_Integer- oder Real-Ausdruck erwartet % The first argument to \var{str} must a real or integer type. type_e_wrong_type_in_array_constructor=04024_E_Falscher Typ im Array-Konstructor % You are trying to use a type in an array constructor which is not % allowed. type_e_wrong_parameter_type=04025_E_Inkompatible Typen fr Argument Nr. #$1: habe $2 erhalten, aber $3 erwartet % You are trying to pass an invalid type for the specified parameter. type_e_no_method_and_procedure_not_compatible=04026_E_Methode (Variable) und Prozedur (Variable) sind nicht kompatibel % You can't assign a method to a procedure variable or a procedure to a % method pointer. type_e_wrong_math_argument=04027_E_Unzul„ssige Konstante an interne Algebrafunktion bergeben % The constant argument passed to a ln or sqrt function is out of % the definition range of these functions. type_e_no_addr_of_constant=04028_E_Von Konstanten kann keine Adresse bestimmt werden % It's not possible to get the address of a constant, because they % aren't stored in memory, you can try making it a typed constant. type_e_argument_cant_be_assigned=04029_E_Auf das Argument kann nichts zugewiesen werden % Only expressions which can be on the left side of an % assignment can be passed as call by reference argument % Remark: Properties can be only % used on the left side of an assignment, but they can't be used as arguments type_e_cannot_local_proc_to_procvar=04030_E_Kann lokale Prozedur/Funktion nicht an Prozedurvariable zuweisen % It's not allowed to assign a local procedure/function to a % procedure variable, because the calling of local procedure/function is % different. You can only assign local procedure/function to a void pointer. type_e_no_assign_to_addr=04031_E_Kann einer Adresse keine Werte zuweisen % It's not allowed to assign a value to an address of a variable,constant, % procedure or function. You can try compiling with -So if the identifier % is a procedure variable. type_e_no_assign_to_const=04032_E_Kann einer Konstanten keine Werte zuweisen % It's not allowed to assign a value to a variable which is declared % as a const. This is normally a parameter declared as const, to allow % changing make the parameter value or var. % \end{description} # # Symtable # % \section{Symbol handling} % This section lists all the messages that concern the handling of symbols. % This means all things that have to do with procedure and variable names. % \begin{description} sym_e_id_not_found=05000_E_Bezeichner "$1" nicht gefunden % The compiler doesn't know this symbol. Usually happens when you misspel % the name of a variable or procedure, or when you forgot to declare a % variable. sym_f_internal_error_in_symtablestack=05001_F_Interner Fehler in SymTableStack() % An internal error occurred in the compiler; If you encounter such an error, % please contact the developers and try to provide an exact description of % the circumstances in which the error occurs. sym_e_duplicate_id=05002_E_Doppelter Bezeichner "$1" % The identifier was already declared in the current scope. sym_h_duplicate_id_where=05003_H_Bezeichner ist bereits definiert in $1 in Zeile $2 % The identifier was already declared in a previous scope. sym_e_unknown_id=05004_E_Unbekannter Bezeichner "$1" % The identifier encountered hasn't been declared, or is used outside the % scope where it's defined. sym_e_forward_not_resolved=05005_E_Forward-Deklaration "$1" nicht gefunden % This can happen in two cases: % \begin{itemize} % \item This happens when you declare a function (in the \var{interface} part, or % with a \var{forward} directive, but do not implement it. % \item You reference a type which isn't declared in the current \var{type} % block. % \end{itemize} sym_f_id_already_typed=05006_F_Bezeichnertyp ist bereits als Typ definiert % You are trying to redefine a type. sym_e_error_in_type_def=05007_E_Fehler in Typdefinition % There is an error in your definition of a new array type: % \item One of the range delimiters in an array declaration is erroneous. % For example, \var{Array [1..1.25]} will trigger this error. sym_e_type_id_not_defined=05008_E_Typbezeichner nicht definiert % The type identifier has not been defined yet. sym_e_forward_type_not_resolved=05009_E_Forward-Typ "$1" nicht gefunden % The compiler encountered an unknown type. sym_e_only_static_in_static=05010_E_Nur statische Variablen k”nnen in statischen oder „usseren Methoden verwendet werden % A static method of an object can only access static variables. sym_e_invalid_call_tvarsymmangledname=05011_E_Ungltiger Aufruf von tvarsym.mangledname() % An internal error occurred in the compiler; If you encounter such an error, % please contact the developers and try to provide an exact description of % the circumstances in which the error occurs. sym_f_type_must_be_rec_or_class=05012_F_Record- oder Klassen-Typ erwartet % The variable or expression isn't of the type \var{record} or \var{class}. sym_e_no_instance_of_abstract_object=05013_E_Instanzen von Klassen oder Objekten mit abstrakten Methoden sind unzul„ssig % You are trying to generate an instance of a class which has an abstract % method that wasn't overridden. sym_w_label_not_defined=05014_W_Label "$1" nicht definiert % A label was declared, but not defined. sym_e_label_used_and_not_defined=05015_E_Label "$1" benutzt aber nicht definiert % A label was declared and used, but not defined. sym_e_ill_label_decl=05016_E_Ungltige Label-Deklaration % This error should never happen; it occurs if a label is defined outside a % procedure or function. sym_e_goto_and_label_not_supported=05017_E_GOTO und LABEL werden nicht untersttzt (verwenden Sie den Schalter -Sg) % You must compile a program which has \var{label}s and \var{goto} statements % with the \var{-Sg} switch. By default, \var{label} and \var{goto} aren't % supported. sym_e_label_not_found=05018_E_Label nicht gefunden % A \var{goto label} was encountered, but the label isn't declared. sym_e_id_is_no_label_id=05019_E_Bezeichner ist kein Label % The identifier specified after the \var{goto} isn't of type label. sym_e_label_already_defined=05020_E_Label ist bereits definiert % You are defining a label twice. You can define a label only once. sym_e_ill_type_decl_set=05021_E_Ungltige Typdeklaration von Set-Elementen % The declaration of a set contains an invalid type definition. sym_e_class_forward_not_resolved=05022_E_Forward-Klassendefinition nicht gefunden: $1 % You declared a class, but you didn't implement it. sym_n_unit_not_used=05023_H_Unit "$1" wird von "$2" nicht verwendet % The unit referenced in the \var{uses} clause is not used. sym_h_para_identifier_not_used=05024_H_Parameter nicht verwendet: $1 % This is a warning. The identifier was declared (locally or globally) but % wasn't used (locally or globally). sym_n_local_identifier_not_used=05025_N_Lokale Variable nicht verwendet: $1 % You have declared, but not used a variable in a procedure or function % implementation. sym_h_para_identifier_only_set=05026_H_Werte-Parameter "$1" wurde zugewiesen aber nie verwendet % This is a warning. The identifier was declared (locally or globally) % set but not used (locally or globally). sym_n_local_identifier_only_set=05027_N_Lokale Variable "$1" wurde zugewiesen aber nicht verwendet % The variable in a procedure or function % implementation is declared, set but never used. sym_h_local_symbol_not_used=05028_H_Lokales $1-Element "$2" wird nicht verwendet % A local symbol is never used. sym_n_private_identifier_not_used=05029_N_Privates Feld $1.$2 wird nie verwendet sym_n_private_identifier_only_set=05030_N_Privates Feld $1.$2 wurde zugewiesen aber nie verwendet sym_n_private_method_not_used=05031_N_Private Methode $1.$2 wird nie verwendet sym_e_set_expected=05032_E_Mengentyp erwartet % The variable or expression isn't of type \var{set}. This happens in an % \var{in} statement. sym_w_function_result_not_set=05033_W_Funktionsergebnis scheint nicht gesetzt zu sein % You can get this warning if the compiler thinks that a function return % value is not set. This will not be displayed for assembler procedures, % or procedures that contain assembler blocks. sym_w_wrong_C_pack=05034_W_Typ "$1" ist im aktuellen Record mit C-Packing nicht korrekt ausgerichtet % Arrays with sizes not multiples of 4 will be wrongly aligned % for C structures. sym_e_illegal_field=05035_E_Unbekannter Record-Feldbezeichner $1 % The field doesn't exist in the record definition. sym_n_uninitialized_local_variable=05036_W_Lokale Variable "$1" wird verwendet, bevor ihr ein Wert zugewiesen wurde sym_n_uninitialized_variable=05037_W_Variable "$1" scheint nicht initialisert worden zu sein % These messages are displayed if the compiler thinks that a variable will % be used (i.e. appears in the right-hand-side of an expression) when it % wasn't initialized first (i.e. appeared in the left-hand side of an % assigment) sym_e_id_no_member=05038_E_Bezeichener verweist nicht auf ein Element: $1 % When using the extended syntax of \var{new}, you must specify the constructor % method of the class you are trying to create. The procedure you specified % does not exist. sym_b_param_list=05039_B_Deklaration gefunden: $1 % You get this when you use the \var{-vb} switch. In case an overloaded % procedure is not found, then all candidate overloaded procedures are % listed, with their parameter lists. sym_e_segment_too_large=05040_E_Datensegment zu gross (max. 2GB) % You get this when you declare an array whose size exceeds the 2GB limit. % \end{description} # # Codegenerator # % \section{Code generator messages} % This section lists all messages that can be displayed if the code % generator encounters an error condition. % \begin{description} cg_e_break_not_allowed=06000_E_BREAK nicht zul„ssig % You're trying to use \var{break} outside a loop construction. cg_e_continue_not_allowed=06001_E_CONTINUE nicht zul„ssig % You're trying to use \var{continue} outside a loop construction. cg_e_too_complex_expr=06002_E_Ausdruck zu komplex - FPU Stackberlauf % Your expression is too long for the compiler. You should try dividing the % construct over multiple assignments. cg_e_illegal_expression=06003_E_Ungltiger Ausdruck % This can occur under many circumstances. Mostly when trying to evaluate % constant expressions. cg_e_invalid_integer=06004_E_Ungltiger Ausdruck, kein Integer % You made an expression which isn't an integer, and the compiler expects the % result to be an integer. cg_e_invalid_qualifier=06005_E_Ungltige Kombination % One of the following is happening : % \begin{itemize} % \item You're trying to access a field of a variable that is not a record. % \item You're indexing a variable that is not an array. % \item You're dereferencing a variable that is not a pointer. % \end{itemize} cg_e_upper_lower_than_lower=06006_E_Oberes Bereichsende < unteres Bereichsende % You are declaring a subrange, and the lower limit is higher than the high % limit of the range. cg_e_illegal_count_var=06007_E_Unzul„ssige Z„hlvariable % The type of a \var{for} loop variable must be an ordinal type. % Loop variables cannot be reals or strings. cg_e_cant_choose_overload_function=06008_E_Kann mich bestimmen, welche berladene Funktion aufgerufen werden soll % You're calling overloaded functions with a parameter that doesn't correspond % to any of the declared function parameter lists. e.g. when you have declared % a function with parameters \var{word} and \var{longint}, and then you call % it with a parameter which is of type \var{integer}. cg_e_parasize_too_big=06009_E_Gr”sse der Parameterliste bersteigt 65535 Bytes % The I386 processor limits the parameter list to 65535 bytes (the \var{RET} % instruction causes this) cg_e_illegal_type_conversion=06010_E_Unzul„ssige Typumwandlung % When doing a type-cast, you must take care that the sizes of the variable and % the destination type are the same. cg_d_pointer_to_longint_conv_not_portable=06011_D_Umwandlung zwischen ganzen Zahlen und Pointern ist zwischen verschiedenen Plattformen nicht portabel % If you typecast a pointer to a longint, this code will not compile % on a machine using 64bit for pointer storage. cg_e_file_must_call_by_reference=06012_E_Dateitypen mssen VAR Parameter sein % You cannot specify files as value parameters, i.e. they must always be % declared \var{var} parameters. cg_e_cant_use_far_pointer_there=06013_E_Die Verwendung eines FAR-Zeigers ist in dieser Art nicht erlaubt % Free Pascal doesn't support far pointers, so you cannot take the address of % an expression which has a far reference as a result. The \var{mem} construct % has a far reference as a result, so the following code will produce this % error: % \begin{verbatim} % var p : pointer; % ... % p:=@mem[a000:000]; % \end{verbatim} cg_e_var_must_be_reference=06014_E_Unzul„ssiger "call by reference"-Parameter % You are trying to pass a constant or an expression to a procedure that % requires a \var{var} parameter. Only variables can be passed as a \var{var} % parameter. cg_e_dont_call_exported_direct=06015_E_Mit EXPORT deklarierte Funktionen k”nnen nicht aufgerufen werden % No longer in use. cg_w_member_cd_call_from_method=06016_W_M”glicherweise unzul„ssiger Aufruf eines Konstruktors oder Destruktors (passt nicht in diesen Kontext) % No longer in use. cg_n_inefficient_code=06017_N_Uneffiziente Programmierung % You construction seems dubious to the compiler. cg_w_unreachable_code=06018_W_Code wird niemals ausgefhrt % You specified a loop which will never be executed. Example: % \begin{verbatim} % while false do % begin % {.. code ...} % end; % \end{verbatim} cg_e_stackframe_with_esp=06019_E_Prozeduraufruf mit Stackframe ESP/SP % The compiler enocountered a procedure or function call inside a % procedure that uses a \var{ESP/SP} stackframe. Normally, when a call is % done the procedure needs a \var{EBP} stackframe. cg_e_cant_call_abstract_method=06020_E_Abstrakte Methoden k”nnen nicht direkt aufgerufen werden % You cannot call an abstract method directy, instead you must call a % overriding child method, because an abstract method isn't implemented. cg_f_internal_error_in_getfloatreg=06021_F_Interner Fehler in getfloatreg(), Allozierungsfehler % An internal error occurred in the compiler; If you encounter such an error, % please contact the developers and try to provide an exact description of % the circumstances in which the error occurs. cg_f_unknown_float_type=06022_F_Unbekannter Fliesskommatyp % The compiler cannot determine the kind of float that occurs in an expression. cg_f_secondvecn_base_defined_twice=06023_F_SecondVecn() Basis wurde zweimal definiert % An internal error occurred in the compiler; If you encounter such an error, % please contact the developers and try to provide an exact description of % the circumstances in which the error occurs. cg_f_extended_cg68k_not_supported=06024_F_Extended wird auf der m68k-Plattform nicht untersttzt % The var{extended} type is not supported on the m68k platform. cg_f_32bit_not_supported_in_68000=06025_F_Vorzeichenlose 32-Bit-Typen werden im MC68000-Modus nicht unterstzt % The cardinal/dword is not supported on the m68k platform. cg_f_internal_error_in_secondinline=06026_F_Interner Fehler in secondinline() % An internal error occurred in the compiler; If you encounter such an error, % please contact the developers and try to provide an exact description of % the circumstances in which the error occurs. cg_d_register_weight=06027_D_Register $1 Gewichtung $2 $3 % Debugging message. Shown when the compiler considers a variable for % keeping in the registers. cg_e_stacklimit_in_local_routine=06028_E_Stacklimit in lokaler Routine berschritten % Your code requires a too big stack. Some operating systems pose limits % on the stack size. You should use less variables or try ro put large % variables on the heap. cg_d_stackframe_omited=06029_D_Stackframe wird ausgelassen % Some procedure/functions do not need a complete stack-frame, so it is omitted. % This message will be displayed when the {-vd} switch is used. cg_w_64bit_range_check_not_supported=06030_W_Bereichsberprfung fr 64-Bit-Integer wird fr die Zielplattform nicht untersttzt % 64 bit range check is not yet implemented for 32 bit processors. cg_e_unable_inline_object_methods=06031_E_Objektmethoden k”nnen nicht Inline sein % You cannot have inlined object methods. cg_e_unable_inline_procvar=06032_E_Procvar-Aufrufe k”nnen nicht Inline sein % A procedure with a procedural variable call cannot be inlined. cg_e_no_code_for_inline_stored=06033_E_Kein Code fr Inline-Prozedur gespeichert % The compiler couldn't store code for the inline procedure. cg_e_no_call_to_interrupt=06034_E_Direkter Aufruf von Interruptprozedur $1 ist nicht m”glich % You can not call an interrupt procedure directly from FPC code cg_e_can_access_element_zero=06035_E_Auf Element Null von Ansi/Wide- oder Longstring kann nicht zugegriffen werden, benutzen Sie stattdessen (Set)Length % You should use \var{setlength} to set the length of an ansi/wide/longstring % and \var{length} to get the length of such kinf of string cg_e_include_not_implemented=06036_E_Include und Exclude sind fr diesen Fall noch nicht implementiert % \var{include} and \var{exclude} are only partially % implemented for \var{i386} processors % and not at all for \var{m68k} processors. cg_e_cannot_call_cons_dest_inside_with=06037_E_Konstruktoren und Destruktoren k”nnen in diesem Kontext nicht aufgerufen werden % Inside a \var{With} clause you cannot call a constructor or destructor for the % object you have in the \var{with} clause. cg_e_cannot_call_message_direct=06038_E_Kann Messagehandler-Methode nicht direkt aufrufen % A message method handler method can't be called directly if it contains an % explicit self argument % \end{description} # EndOfTeX # # Assembler reader # cg_e_goto_inout_of_exception_block=06039_E_Sprung in- oder aus Exceptionblock heraus % It isn't allowed to jump in or outside of an exception block like \var{try..finally..end;}: % \begin{verbatim} % label 1; % % ... % % try % if not(final) then % goto 1; // this line will cause an error % finally % ... % end; % 1: % ... % \end{verbatim} % \end{description} # EndOfTeX cg_e_control_flow_outside_finally=06040_E_Kontrollfluss-Anweisungen sind in einem Finally-Block nicht erlaubt % It isn't allowed to use the control flow statements \var{break}, % \var{continue} and \var{exit} % inside a finally statement. The following example shows the problem: % \begin{verbatim} % ... % try % p; % finally % ... % exit; // This exit ISN'T allowed % end; % ... % % \end{verbatim} % If the procedure \var{p} raises an exception the finally block is % executed. If the execution reaches the exit, it's unclear what to do: % exiting the procedure or searching for another exception handler # EndOfTeX # # Assembler reader # asmr_d_start_reading=07000_D_Starte $1 Stil Assembler Parsen % This informs you that an assembler block is being parsed asmr_d_finish_reading=07001_D_Beende $1 Stil Assembler Parsen % This informs you that an assembler block has finished. asmr_e_none_label_contain_at=07002_E_Nicht-Label Bezeichner enth„lt @ % A identifier which isn't a label can't contain a @. asmr_w_override_op_not_supported=07003_W_Override-Operator wird nicht untersttzt % The Override operator is not supported asmr_e_building_record_offset=07004_E_Fehler beim Ermitteln des Recordoffsets % There has an error occured while building the offset of a record/object % structure, this can happend when there is no field specified at all or % an unknown field identifier is used. asmr_e_offset_without_identifier=07005_E_OFFSET ohne Bezeicner verwendet % You can only use OFFSET with an identifier. Other syntaxes aren't % supported asmr_e_type_without_identifier=07006_E_TYPE verwendet ohne Bezeichner % You can only use TYPE with an identifier. Other syntaxes aren't % supported asmr_e_no_local_or_para_allowed=07007_E_Lokale Variable oder Parameter k”nnen hier nicht verwendet werden % You can't use a local variable or parameter here, mostly because the % addressing of locals and parameters is done using the %ebp register so the % address can't be get directly. asmr_e_need_offset=07008_E_Hier muss OFFSET verwendet werden % You need to use OFFSET here to get the address of the identifier. asmr_e_need_dollar=07009_E_Hier muss "$" verwendet werden % You need to use $ here to get the address of the identifier. asmr_e_cant_have_multiple_relocatable_symbols=07010_E_Verwendung von mehreren verschiebbaren Symbolen nicht m”glich % You can't have more than one relocatable symbol (variable/typed constant) % in one argument. asmr_e_only_add_relocatable_symbol=07011_E_Verschiebbares Symbol kann nur addiert werden % Relocatable symbols (variable/typed constant) can't be used with other % operators. Only addition is allowed. asmr_e_invalid_constant_expression=07012_E_Ungltiger Konstantenausdruck % There is an error in the constant expression. asmr_e_relocatable_symbol_not_allowed=07013_E_Verschiebbares Symbol ist nicht zul„ssig % You can't use a relocatable symbol (variable/typed constant) here. asmr_e_invalid_reference_syntax=07014_E_Ungltige Verweis-Syntax % There is an error in the reference. asmr_e_local_para_unreachable=07015_E_Sie k”nnen "$1" von diesem Code aus nicht erreichen % You can not read directly the value of local or para % of a higher level in assembler code (except for % local assembler code without parameter nor locals). asmr_e_local_label_not_allowed_as_ref=07016_E_Lokale Symbole/Labels sind nicht als Referenz zul„ssig % You can't use local symbols/labels as references asmr_e_wrong_base_index=07017_E_Ungltige Verwendung von Basis- und Index-Registern % There is an error with the base and index register asmr_w_possible_object_field_bug=07018_W_M”glicher Fehler bei Objektfeld-Behandlung % Fields of objects or classes can be reached directly in normal or objfpc % modes but TP and Delphi modes treat the field name as a simple offset. asmr_e_wrong_scale_factor=07019_E_Falscher Skalierungsfaktor angegeben % The scale factor given is wrong, only 1,2,4 and 8 are allowed asmr_e_multiple_index=07020_E_Mehrfache Verwendung fon Index-Registern % You are trying to use more than one index register asmr_e_invalid_operand_type=07021_E_Ungltiger Operandentyp % The operand type doesn't match with the opcode used asmr_e_invalid_string_as_opcode_operand=07022_E_Unglitge Zeichenkette als Opcode-Operand: $1 % The string specified as operand is not correct with this opcode asmr_w_CODE_and_DATA_not_supported=07023_W_@CODE und @DATA werden nicht untersttzt % @CODE and @DATA are unsupported and are ignored. asmr_e_null_label_ref_not_allowed=07024_E_Null-Label-Bezug nicht m”glich asmr_e_expr_zero_divide=07025_E_Division durch Null in Assembler-Ausdruck asmr_e_expr_illegal=07026_E_Ungltiger Ausdruck asmr_e_escape_seq_ignored=07027_E_Escape-Sequenz ignoriert: $1 asmr_e_invalid_symbol_ref=07028_E_Ungltige Symbolverwendung asmr_w_fwait_emu_prob=07029_W_FWAIT kann Emulationsprobleme mit emu387 verursachen asmr_w_fadd_to_faddp=07030_W_FADD ohne Operand wurde in FADDPbersetzt asmr_w_enter_not_supported_by_linux=07031_W_Der ENTER-Befehl wird vom Linux-Kernel nicht untersttzt % ENTER instruction can generate a stack page fault that is not % caught correctly by the i386 Linux page handler. asmr_w_calling_overload_func=07032_W_Aufruf einer berladenen Funktion in Assembler asmr_e_unsupported_symbol_type=07033_E_Nicht untersttzter Symboltyp fr Operand asmr_e_constant_out_of_bounds=07034_E_Wert der Konstante ausserhalb des zul„ssigen Bereichs asmr_e_error_converting_decimal=07035_E_Fehler beim Umwandeln in Dezimal $1 asmr_e_error_converting_octal=07036_E_Fehler beim Umwandeln in Oktal $1 asmr_e_error_converting_binary=07037_E_Fehler beim Umwandeln in Bin„r $1 asmr_e_error_converting_hexadecimal=07038_E_Fehler beim Umwandeln in Hexadezimal $1 asmr_h_direct_global_to_mangled=07039_H_$1 bersetzt nach $2 asmr_w_direct_global_is_overloaded_func=07040_W_$1 ist einer berladenen Funktion zugeordnet asmr_e_cannot_use_SELF_outside_a_method=07041_E_Kann SELF nicht ausserhalb einer Methode verwenden asmr_e_cannot_use_OLDEBP_outside_nested_procedure=07042_E_Kann OLDEBP ausserhalb einer verschachtelten Prozedur nicht verwenden asmr_e_void_function=07043_W_Prozeduren k”nnen keinen Wert im Assembler-Code zurckliefern asmr_e_SEG_not_supported=07044_E_SEG nicht untersttzt asmr_e_size_suffix_and_dest_dont_match=07045_E_Gr”ssensuffix und Ziel- oder Quellgr”sse passen nicht zusammen asmr_w_size_suffix_and_dest_dont_match=07046_W_Gr”ssensuffix und Ziel- oder Quellgr”sse passen nicht zusammen asmr_e_syntax_error=07047_E_Assembler Syntaxfehler asmr_e_invalid_opcode_and_operand=07048_E_Ungltige Kombination von Opcode und Operanden asmr_e_syn_operand=07049_E_Assembler Syntaxfehler im Operanden asmr_e_syn_constant=07050_E_Assembler Syntaxfehler in Konstanten asmr_e_invalid_string_expression=07051_E_Ungltiger Stringausdruck asmr_w_const32bit_for_address=07052_-Bit-Konstanten fr Adresse erzeugt asmr_e_unknown_opcode=07053_E_Unbekannter Opcode $1 asmr_e_invalid_or_missing_opcode=07054_E_Ungltiger oder fehlender Opcode asmr_e_invalid_prefix_and_opcode=07055_E_Ungltige Kombination von Prefix und Opcode: $1 asmr_e_invalid_override_and_opcode=07056_E_Ungltige Kombination von Override und Opcode: $1 asmr_e_too_many_operands=07057_E_Zu viele Operanden in der Zeile asmr_w_near_ignored=07058_W_NEAR ignoriert asmr_w_far_ignored=07059_W_FAR ignoriert asmr_e_dup_local_sym=07060_E_Doppelters lokales Symbol $1 asmr_e_unknown_local_sym=07061_E_Undefiniertes lokales Symbol $1 asmr_e_unknown_label_identifier=07062_E_Unbekannter Label-Bezeichner $1 asmr_e_invalid_register=07063_E_Ungltiger Registername asmr_e_invalid_fpu_register=07064_E_Ungltiger Name fr Fliesskommaregister asmr_e_nor_not_supported=07065_E_NOR nicht untersttzt asmr_w_modulo_not_supported=07066_W_Modulo nicht untersttzt asmr_e_invalid_float_const=07067_E_Ungltige Fliesskommakonstante $1 asmr_e_invalid_float_expr=07068_E_Ungltiger Fliesskommaausdruck asmr_e_wrong_sym_type=07069_E_Falscher Symboltyp asmr_e_cannot_index_relative_var=07070_E_Kann lokale Variable oder Parameter nicht mit Register indizieren asmr_e_invalid_seg_override=07071_E_Ungltiger Segmentoverride-Ausdruck asmr_w_id_supposed_external=07072_W_Bezeichner $1 ist vermutlich External asmr_e_string_not_allowed_as_const=07073_E_Strings sind als Konstanten unzul„ssig asmr_e_no_var_type_specified=07074_Typ der Variablen nicht angegeben asmr_w_assembler_code_not_returned_to_text=07075_E_Assemblercode kehrt nicht zum Text zurck asmr_e_not_directive_or_local_symbol=07076_E_Keine Direktive oder lokales Symbol $1 asmr_w_using_defined_as_local=07077_E_Verwendung eines definierten Namens als lokales Label asmr_e_dollar_without_identifier=07078_E_Dollarzeichen wird ohne Bezeichner verwendet asmr_w_32bit_const_for_address=07079_W_32-Bit-Konstante fr Adresse erzeugt asmr_n_align_is_target_specific=07080_N_.align ist abh„ngig von Zielplattform, verwende .balign oder .p2align asmr_e_cannot_access_field_directly_for_parameters=07081_E_Kann fr Parameter nicht direkt auf Felder zugreifen % You should load the parameter first into a register and then access the % fields using that register. asmr_e_cannot_access_object_field_directly=07082_E_Kann auf Felder von Objekten/Klassen nicht direkt zugreifen % You should load the self pointer first into a register and then access the % fields using the register as base. By default the self pointer is available % in the esi register on i386. # # Assembler/binary writers # asmw_f_too_many_asm_files=08000_F_Zu viele Assembler-Dateien asmw_f_assembler_output_not_supported=08001_F_Gew„hlte Assemblerausgabe wird nicht untersttzt asmw_f_comp_not_supported=08002_F_Comp nicht untersttzt asmw_f_direct_not_supported=08003_F_Direct nicht untersttzt fr bin„res Schreiben asmw_e_alloc_data_only_in_bss=08004_E_Allozieren von Daten ist nur in "bss"-Abschnitten zul„ssig asmw_f_no_binary_writer_selected=08005_F_Kein Bin„rschreiber ausgew„hlt asmw_e_opcode_not_in_table=08006_E_Asm: Opcode $1 nicht in Tabelle enthalten asmw_e_invalid_opcode_and_operands=08007_E_Asm: $1 ungltige Kombination von Opcode und Operanden asmw_e_16bit_not_supported=08008_E_Asm: 16-Bit-Verweise werden nicht unterttzt asmw_e_invalid_effective_address=08009_E_Asm: Ungltige effektive Adresse asmw_e_immediate_or_reference_expected=08010_E_Asm: Konstanten Ausdruck oder Referenz erwartet asmw_e_value_exceeds_bounds=08011_E_Asm: $1 Wert berschreitet Grenzen $2 asmw_e_short_jmp_out_of_range=08012_E_Asm: "Short jump" ist ausserhalb der Bereichs $1 asmw_e_undefined_label=08013_E_Asm: Undefiniertes Label: $1 # # Executing linker/assembler # exec_w_source_os_redefined=09000_W_Quell-Betriebssystem wurde neu definiert exec_i_assembling_pipe=09001_I_Assembliere (pipe) $1 exec_d_cant_create_asmfile=09002_E_Kann Assemblerdatei nicht erzeugen: $1 % The mentioned file can't be create. Check if you've % permission to create this file exec_e_cant_create_objectfile=09003_E_Kann Objektdatei nicht erzeugen: $1 % The mentioned file can't be create. Check if you've % permission to create this file exec_e_cant_create_archivefile=09004_E_Kann Archivdatei nicht erzeugen: $1 % The mentioned file can't be create. Check if you've % permission to create this file exec_w_assembler_not_found=09005_W_Assembler $1 nicht gefunden, schalte um auf externes Assemblieren exec_t_using_assembler=09006_T_Benutze Assembler: $1 exec_w_error_while_assembling=09007_W_Fehler w„hren des Assemblierens, Exitcode $1 exec_w_cant_call_assembler=09008_W_Kann den Assembler nicht aufrufen, Fehler $1 beim Umschalten auf externen Assembler exec_i_assembling=09009_I_Assembliere $1 exec_i_assembling_smart=09010_I_Assembliere mit Smartlinking $1 exec_w_objfile_not_found=09011_W_Objekt $1 nicht gefunden, Linken kann fehlschlagen! exec_w_libfile_not_found=09012_W_Bibliothek $1 nicht gefunden, Linken kann fehlschlagen! exec_w_error_while_linking=09013_W_Fehler w„hrend des Linkens exec_w_cant_call_linker=09014_W_Kann Linker nicht aufrufen, schalte um auf externes Linken exec_i_linking=09015_I_Linke $1 exec_w_util_not_found=09016_W_Hilfsprogramm "$1" nicht gefunden, schalte um auf externes Linken exec_t_using_util=09017_T_Benutze Hilfsprogramm $1 exec_e_exe_not_supported=09018_E_Erzeugen von ausfhrbaren Dateien nicht untersttzt exec_e_dll_not_supported=09019_E_Dynamische Bibliotheken nicht untersttzt exec_i_closing_script=09020_I_Schliesse Skript $1 exec_w_res_not_found=09021_W_Resource Compiler nicht gefunden, schalte um auf externen Modus exec_i_compilingresource=09022_I_Kompiliere Resource $1 # # Executable information # execinfo_f_cant_process_executable=09023_F_Kann ausfhrbare Datei nicht nachbearbeiten: $1 execinfo_f_cant_open_executable=09024_F_Kann ausfhrbare Datei nicht ”ffnen: $1 execinfo_x_codesize=09025_X_Gr”sse des Codes: $1 Bytes execinfo_x_initdatasize=09026_X_Gr”sse der initialisierten Daten: $1 Bytes execinfo_x_uninitdatasize=09027_X_Gr”sse der nicht initialisierten Daten: $1 Bytes execinfo_x_stackreserve=09028_X_Stack Bereich "reserved": $1 Bytes execinfo_x_stackcommit=09029_X_Stack Bereich "commited": $1 Bytes # # Unit loading # # BeginOfTeX % \section{Unit loading messages.} % This section lists all messages that can occur when the compiler is % loading a unit from disk into memory. Many of these mesages are % informational messages. % \begin{description} unit_t_unitsearch=10000_T_Suche Unit: $1 % When you use the \var{-vt}, the compiler tells you where it tries to find % unit files. unit_t_ppu_loading=10001_T_Lade PPU: $1 % When the \var{-vt} switch is used, the compiler tells you % what units it loads. unit_u_ppu_name=10002_U_PPU-Name: $1 % When you use the \var{-vu} flag, the unit name is shown. unit_u_ppu_flags=10003_U_PPU-Flags: $1 % When you use the \var{-vu} flag, the unit flags are shown. unit_u_ppu_crc=10004_U_PPU-CRC: $1 % When you use the \var{-vu} flag, the unit CRC check is shown. unit_u_ppu_time=10005_U_PPU-Zeit: $1 % When you use the \var{-vu} flag, the unit time is shown. unit_u_ppu_file_too_short=10006_U_PPU-Datei zu kurz % When you use the \var{-vu} flag, the unit time is shown. unit_u_ppu_invalid_header=10007_U_PPU Ungltiger Header (kein PPU am Anfang) % A unit file contains as the first three bytes the ascii codes of \var{PPU} unit_u_ppu_invalid_version=10008_U_PPU Ungltige Version $1 % This unit file was compiled with a different version of the compiler, and % cannot be read. unit_u_ppu_invalid_processor=10009_U_PPU ist fr einen anderen Prozessor kompiliert % This unit file was compiled for a different processor type, and % cannot be read unit_u_ppu_invalid_target=10010_U_PPU ist fr ein anderes Zielsystem kompiliert % This unit file was compiled for a different processor type, and % cannot be read unit_u_ppu_source=10011_U_PPU Quelle: $1 % When you use the \var{-vu} flag, the unit CRC check is shown. unit_u_ppu_write=10012_U_Schreibe $1 % When you specify the \var{-vu} switch, the compiler will tell you where it % writes the unit file. unit_f_ppu_cannot_write=10013_F_Kann PPU-Datei nicht schreiben % An err unit_f_ppu_read_error=10014_F_Lese PPU-Datei % Unexpected end of file unit_f_ppu_read_unexpected_end=10015_F_Unerwartetes Ende der PPU-Datei % This means that the unit file was corrupted, and contains invalid % information. Recompilation will be necessary. unit_f_ppu_invalid_entry=10016_F_Ungltiger Eintrag in PPU-Datei: $1 % The unit the compiler is trying to read is corrupted, or generated with a % newer version of the compiler. unit_f_ppu_dbx_count_problem=10017_F_PPU Dbx Z„hler-Problem % There is an inconsistency in the debugging information of the unit. unit_e_illegal_unit_name=10018_E_Ungltiger Unitname: $1 % The name of the unit doesn't match the file name. unit_f_too_much_units=10019_F_Zu viele Units % \fpc has a limit of 1024 units in a program. You can change this behavior % by changing the \var{maxunits} constant in the \file{files.pas} file of the % compiler, and recompiling the compiler. unit_f_circular_unit_reference=10020_F_Gegenseitige Abh„ngigkeit von Units zwischen $1 und $2 % Two units are using each other in the interface part. This is only allowed % in the \var{implementation} part. At least one unit must contain the other one % in the \var{implementation} section. unit_f_cant_compile_unit=10021_F_Kann Unit "$1" nicht bersetzen, keine Quellen vorhanden % A unit was found that needs to be recompiled, but no sources are % available. unit_f_cant_find_ppu=10022_F_Kann Unit "$1" nicht finden % You tried to use a unit of which the PPU file isn't found by the % compiler. Check your config files for the unit pathes unit_w_unit_name_error=10023_W_Unit "$1" wurde nicht gefunden, aber "$2" existiert unit_f_unit_name_error=10024_F_Unit "$1" gesucht, aber "$2" gefunden % Dos truncation of 8 letters for unit PPU files % may lead to problems when unit name is longer than 8 letters. unit_w_switch_us_missed=10025_W_šbersetzen der Systemunit erfordert den Schalter -Us % When recompiling the system unit (it needs special treatment), the % \var{-Us} must be specified. unit_f_errors_in_unit=10026_F_Es traten $1 Fehler beim šbersetzen des Moduls auf, halte an % When the compiler encounters a fatal error or too many errors in a module % then it stops with this message. unit_u_load_unit=10027_U_Lade aus $1 ($2) die Unit $3 % When you use the \var{-vu} flag, which unit is loaded from which unit is % shown. unit_u_recompile_crc_change=10028_U_šbersetze $1 erneut, Prfsumme fr $2 hat sich ge„ndert unit_u_recompile_source_found_alone=10029_U_šbersetze "$1", nur Quellcode gefunden % When you use the \var{-vu} flag, these messages tell you why the current % unit is recompiled. unit_u_recompile_staticlib_is_older=10030_U_šbersetze Unit erneut, statische Biblothek ist „lter als PPU-Datei % When you use the \var{-vu} flag, the compiler warns if the static library % of the unit are older than the unit file itself. unit_u_recompile_sharedlib_is_older=10031_U_šbersetze Unit erneut, gemeinsame Bibliothek ist „lter als PPU-Datei % When you use the \var{-vu} flag, the compiler warns if the shared library % of the unit are older than the unit file itself. unit_u_recompile_obj_and_asm_older=10032_U_šbersetze Unit erneut, obj und asm sind „lter als PPU-Datei % When you use the \var{-vu} flag, the compiler warns if the assembler of % object file of the unit are older than the unit file itself. unit_u_recompile_obj_older_than_asm=10033_U_šbersetze Unit erneut, obj ist „lter als asm % When you use the \var{-vu} flag, the compiler warns if the assembler % file of the unit is older than the object file of the unit. unit_u_start_parse_interface=10034_U_Parse Interface-Abschnitt von "$1" % When you use the \var{-vu} flag, the compiler warns that it starts % parsing the interface part of the unit unit_u_start_parse_implementation=10035_U_Parse Implementation-Abschnitt von "$1" % When you use the \var{-vu} flag, the compiler warns that it starts % parsing the implementation part of the unit unit_u_second_load_unit=10036_U_Zweites Laden fr Unit "$1" % When you use the \var{-vu} flag, the compiler warns that it starts % recompiling a unit for the second time. This can happend with interdepend % units. unit_u_check_time=10037_U_PPU prfe Datei $1 Zeit $2 % When you use the \var{-vu} flag, the compiler show the filename and % date and time of the file which a recompile depends on % \end{description} # EndOfTeX # # Options # option_usage=11000_$1 [Optionen] [Optionen] # BeginOfTeX % % \section{Command-line handling errors} % This section lists errors that occur when the compiler is processing the % command line or handling the configuration files. % \begin{description} option_only_one_source_support=11001_W_Nur eine Quelldatei untersttzt % You can specify only one source file on the command line. The first % one will be compiled, others will be ignored. This may indicate that % you forgot a \var{'-'} sign. option_def_only_for_os2=11002_W_DEF-Datei kann nur fr OS/2 erzeugt werden % This option can only be specified when you're compiling for OS/2 option_no_nested_response_file=11003_E_Verschachtelte Response-Dateien werden nicht untersttzt % you cannot nest response files with the \var{@file} command-line option. option_no_source_found=11004_F_Kein Name fr Quelldatei auf der Kommandzeile % The compiler expects a source file name on the command line. option_no_option_found=11005_N_Keine Angeben in Konfigurationsdatei "$1" gefunden % The compiler didn't find any option in that config file. option_illegal_para=11006_E_Ungltiger Parameter: $1 % You specified an unknown option. option_help_pages_para=11007_H_-? zeigt Hilfetext an % When an unknown option is given, this message is diplayed. option_too_many_cfg_files=11008_F_Zu viele verschachtelte Konfigurtionsdateien % You can only nest up to 16 config files. option_unable_open_file=11009_F_Kann Datei nicht ”ffnen $1 % The option file cannot be found. option_reading_further_from=11010_N_Lese weitere Optionen aus $1 % Displayed when you have notes turned on, and the compiler switches % to another options file. option_target_is_already_set=11011_W_Zielsystem ist bereits gesetzt: $1 % Displayed if more than one \var{-T} option is specified. option_no_shared_lib_under_dos=11012_W_Gemeinsame Bibliotheken sind auf der DOS Platform nicht verfgbar, verwende stattdessen statische Bibliotheken % If you specify \var{-CD} for the \dos platform, this message is displayed. % The compiler supports only static libraries under \dos option_too_many_ifdef=11013_F_Zu viele IF(N)DEFs % the \var{\#IF(N)DEF} statements in the options file are not balanced with % the \var{\#ENDIF} statements. option_too_many_endif=11014_F_Zu viele ENDIFs % the \var{\#IF(N)DEF} statements in the options file are not balanced with % the \var{\#ENDIF} statements. option_too_less_endif=11015_F_Offene Bedingung am Dateiende % the \var{\#IF(N)DEF} statements in the options file are not balanced with % the \var{\#ENDIF} statements. option_no_debug_support=11016_W_Erzeugung von Debug-Informationen wird von dieser ausfhrbaren Datei nicht untersttzt % It is possible to have a compiler executable that doesn't support % the generation of debugging info. If you use such an executable with the % \var{-g} switch, this warning will be displayed. option_no_debug_support_recompile_fpc=11017_H_Versuchen Sie mit -dGDB erneut zu kompilieren % It is possible to have a compiler executable that doesn't support % the generation of debugging info. If you use such an executable with the % \var{-g} switch, this warning will be displayed. option_obsolete_switch=11018_E_Sie verwenden den nun berflssigen Schalter $1 % this warns you when you use a switch that is not needed/supported anymore. % It is recommended that you remove the switch to overcome problems in the % future, when the switch meaning may change. option_obsolete_switch_use_new=11019_E_Sie benutzen den nun berflssigen Schalter $1, bitte benutzen Sie $2 % this warns you when you use a switch that is not supported anymore. You % must now use the second switch instead. % It is recommended that you change the switch to overcome problems in the % future, when the switch meaning may change. option_switch_bin_to_src_assembler=11020_N_Schalte Assembler auf den Standard-Assembler-Quellcodeschreiber % this notifies you that the assembler has been changed because you used the % -a switch which can't be used with a binary assembler writer. option_incompatible_asm=11021_W_Das gew„hlte Assembler-Ausgabeformat "$1" ist nicht mit "$2" kompatibel option_asm_forced=11022_W_Verwendung des Assemblers "$1" erzwungen % The assembler output selected can not generate % object files with the correct format. Therefore, the % default assembler for this target is used instead. %\end{description} # EndOfTeX # # Logo (option -l) # option_logo=11023_[ Free Pascal Compiler Version $FPCVER [$FPCDATE] fr $FPCTARGET Copyright (c) 1993-2002 Florian Kl„mpfl ] # # Info (option -i) # option_info=11024_[ Free Pascal Compiler Version $FPCVER Compiler Datum: $FPCDATE Compiler Zielsystem: $FPCTARGET Dieses Programm unterliegt der GNU General Public Licence Weitere Informationen sind in COPYING.FPC zu finden Fehlerberichte, Vorschl„ge usw. bitte senden an: bugrep@freepascal.org ] # # Help pages (option -? and -h) # option_help_pages=11025_[ **0*_nach booleschen Optionen geben Sie + zum Ein- bzw. - zum Ausschalten an **1a_l”sche die erzeugte Assembler-Datei nicht **2al_liste Quellcode-Zeilen in der Assembler-Datei **2ar_liste Registerbelegungsinformation in Assembler-Datei **2at_liste Temp. Variablenbelegungsinfo in Assembler-Datei **1b_erzeuge Browser-Info **2bl_erzeuge Info zu lokalen Symbolen **1B_erzeuge alle Module (Build) **1C_Optionen fr Code-Erzeugung: 3*2CD_erzeuge auch eine dynamische Bibliothek (nicht untersttzt) **2Ch_ Bytes Heap (zwischen 1023 und 67107840) **2Ci_I/O-Prfung **2Cn_lasse die Linkstufe aus **2Co_prfe šberlauf von Integer-Operationen **2Cr_fhre Bereichsprfung durch **2Cs_setze Gr”sse des Stacks auf **2Ct_fhre Stackprfung durch 3*2CS_erzeuge statische Bibliothek 3*2Cx_benutze Smartlinking **1d_definiere das Symbol *O1D_erzeuge eine DEF-Datei *O2Dd_setze Beschreibung zu *O2Dw_erzeuge PM-Anwendung **1e_setze Pfad zur ausfhrbaren Datei **1F_Dateinamen und Pfade: **2FD_setze das Verzeichnis fr die Compiler-Hilfsprogramme **2Fe_leite die Fehlerausgabe um nach **2FE_setze den Pfad fr Exe/Unit-Dateien auf *L2Fg_identisch mit -Fl **2Fi_erg„nze zum Include-Pfad **2Fl_erg„nze zum Bibliotheks-Pfad *L2FL_benutze als dynamischen Linker **2Fo_erg„nze zum Objektdatei-Pfad **2Fr_lade die Fehler-Meldungs Datei **2Fu_erg„nze zum Unit-Pfad **2FU_Units werden nach ausgegen, hat Vorrang vor -FE *g1g_erzeuge Informationen zur Fehlersuche: *g2gg_Verwende gsym *g2gd_Verwende dbx *g2gh_Heaptrace-Unit einbinden *g2gc_Zeigerberprfung **1i_zeige alle Information ber den Compiler **2iD_zeige Compilerdatum **2iV_zeige Compilerversion **2iSO_zeige Compiler-Betriebssystem **2iSP_zeige Compilerprozessor **2iTO_zeige Ziel-Betriebssystem **2iTP_zeige Zielprozessor **1I_erg„nze zum Include-Pfad **1k_bergebe an den Linker **1l_zeige Logo **1n_Standard-Konfigurationsdatei ignorieren **1o_die erzeugte, ausfhrbaren Datei bekommt den Namen **1pg_erzeuge Profiler-Code fr gprof *L1P_benutze Pipes anstelle von tempor„ren Assembler-Dateien **1S_Syntax-Optionen: **2S2_schalte einige der Delphi 2 Erweiterungen ein **2Sc_untersttze spezielle C Operatoren (*=,+=,/= and -=) **2Sd_sei Delphi-kompatibel **2Se_halte Compiler nach dem ersten Fehler an **2Sg_erlaube LABEL und GOTO **2Sh_benutze ANSI-Strings **2Si_benutze C++ artige INLINE **2Sm_untersttze Makros wie in C (global) **2So_sei TP/BP 7.0 kompatibel **2Sp_sei gpc-kompatibel **2Ss_Kon-und Destruktorname mssen "Init" und "Done" sein **2St_erlaube Schlsselwort static in Objekten **1s_rufe weder Assembler noch Linker auf (nur mit -a) **1u_entferne die Definition fr das Symbol **1U_Unit-Optionen: **2Un_prfe den Unitnamen nicht **2Us_erzeuge eine Systemunit **1v_Meldungen, ist eine Kombination der folgenden Zeichen: **2*_e : Fehler (Standard) d : Debug Info **2*_w : Warnungen u : Unit Info **2*_n : Anmerkungen t : angesprochene/benutzte Dateien **2*_h : Hinweise m : definierte Macros **2*_i : allgemeine Info p : kompilierte Prozeduren **2*_l : Zeilennummern c : Preprozessordirective **2*_a : alles 0 : nichts (ausser Fehlern) **2*_b : alle Prozedurdekla- r : Rhide/GCC kompatibler Modus **2*_ rationen im Fehlerfall x : Exe-Datei Info (nur Win32) **2*_ **1X_Optionen fr ausfhrbare Dateien: *L2Xc_linke mit der C-Bibliothek **2Xs_entferne alle Symbole von ausfhrbarer Datei **2XD_dynamisch linken (definiert FPC_LINK_DYNAMIC) **2XS_statisch linken (default) (definiert FPC_LINK_STATIC) **2XX_smartlinken (definiert FPC_LINK_SMART) **0*_Optionen fr den Prozessor: 3*1A_Ausgabeformat: 3*2Aas_Datei mit Hilfe von GNU AS 3*2Aasaout_Datei mit Hilfe von GNU AS fr aout (Go32v1) 3*2Anasmcoff_coff-Datei mit Hilfe von Nasm 3*2Anasmelf_elf32-Datei (Linux) mit Hilfe von Nasm 3*2Anasmobj_obj-Datei mit Hilfe von Nasm 3*2Amasm_obj-Datei mit Hilfe von Masm (Microsoft) 3*2Atasm_obj-Datei mit Hilfe von Tasm (Borland) 3*2Acoff_coff (Go32v2) benutze internen Schreiber 3*2Apecoff_pecoff (Win32) benutze internen Schreiber 3*1R_Assembler-Leser Format: 3*2Ratt_lese AT&T Assembler Variante 3*2Rintel_lese Intel Assembler Variante 3*2Rdirect_kopiere Assembler-Text direkt in die Assembler-Datei 3*1O_Optimierungen: 3*2Og_erzeuge kleineren Code 3*2OG_erzeuge schnelleren Code (Standard) 3*2Or_Registervariablen (enth„lt eventuell noch Fehler) 3*2Ou_aktiviere unsichere Optimierungen (siehe Dokumentation) 3*2O1_Stufe 1 Optimierungen (schnelle Optimierungen) 3*2O2_Stufe 2 Optimierungen (-O1 + langsamere Optimierungen) 3*2O3_Stufe 3 Optimierungen (gleich wie -O2u) 3*2Op_Ziel-Prozessor: 3*3Op1_Optimierungen fr 386/486 3*3Op2_Optimierungen fr Pentium/PentiumMMX (R) 3*3Op3_Optimierungen fr PPro/PII/c6x86/K6 (R) 3*1T_Ziel-Betriebssystem 3*2TEMX_OS/2 via EMX (EMX/RSX extender inclusive) 3*2TGO32V2_Version 2 von DJ Delorie's DOS extender 3*2TLINUX_Linux 3*2TNETWARE_Novell Netware Module (clib) 3*2TOS2_OS/2 / eComStation 3*2TSUNOS_SunOS/Solaris 3*2TWDOSX_WDOSX DOS extender 3*2TWIN32_Windows 32 Bit 6*1A_Ausgabe Format: 6*2Aas_Unix o-Datei mit Hilfe von GNU AS 6*2Agas_GNU Motorola Assembler 6*2Amit_MIT Syntax (alter GAS) 6*2Amot_Standard Motorola Assembler 6*1O_Optimierungen: 6*2Oa_schalte Optimierer ein 6*2Og_erzeuge kleineren Code 6*2OG_erzeuge schnelleren Code (Standard) 6*2Ox_optimiere maximal (enth„lt eventuell noch Fehler) 6*2O2_setze Ziel-Prozessor auf MC68020+ 6*1R_Assembler-Leser Format: 6*2RMOT_lese Assembler nach Motorola-Art 6*1T_Ziel-Betriebssystem: 6*2TAMIGA_Commodore Amiga 6*2TATARI_Atari ST/STe/TT 6*2TMACOS_Macintosh m68k 6*2TLINUX_Linux-68k **1*_ **1?_zeigt diese Hilfe an 6*2RMOT_lese Assembler nach Motorola-Art 6*1T_Ziel-Betriebssystem: 6*2TAMIGA_Commodore Amiga 6*2TATARI_Atari ST/STe/TT 6*2TMACOS_Macintosh m68k 6*2TLINUX_Linux-68k **1*_ **1?_zeigt diese Hilfe an **1h_zeigt diese Hilfe ohne Warten an ] # # The End... #