fpc/compiler/msg/errorfi.msg
2025-01-10 22:47:03 +01:00

3902 lines
245 KiB
Plaintext
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

%%% Reordering of errorfi.msg respective to errore.msg
%%% Contains all comments from errorfi.msg
#
# This file is part of the Free Pascal Compiler
# Copyright (c) 1999-2018 by the Free Pascal Development team
#
# French (ISO 8859-1) Language File for Free Pascal
# Latest updates contributed by Rémi Dorlet <remi at dorlet.org>
# Based on errore.msg of SVN revision 4165
#
# See the file COPYING.v2, included in this distribution,
# for details about the copyright.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
#
# CodePage 28591
#
# The constants are build in the following order:
# <part>_<type>_<txtidentifier>
#
# <part> is the part of the compiler the message is used
# asmr_ assembler parsing
# asmw_ assembler writing/binary writers
# unit_ unit handling
# scan_ scanner
# parser_ parser
# type_ type checking
# general_ general info
# exec_ calls to assembler, linker, binder
#
# <type> the type of the message it should normally used for
# f_ fatal error
# e_ error
# w_ warning
# n_ note
# h_ hint
# i_ info
# l_ add linenumber
# u_ used
# t_ tried
# c_ conditional
# d_ debug message
# x_ executable informations
#
#
# <type> can contain a minus sign at the beginning to mark that
# the message is off by default. Look at type_w_explicit_string_cast
# for example
#
# General
#
# 01023 is the last used one
#
# BeginOfTeX
% \section{Messages généraux du compilateur}
% Cette partie détaille les messages non fatals,
% mais pouvant apporter une information. La quantité de ces messages
% peut être contrôlé avec l'option de niveau de verbosité \var{-v}.
% \begin{description}
general_t_compilername=01000_T_Compilateur: $1
% When the \var{-vt} switch is used, this line tells you what compiler
% is used.
general_d_sourceos=01001_D_Système d'exploitation du compilateur: $1
% When the \var{-vd} switch is used, this line tells you what the source
% operating system is.
general_i_targetos=01002_I_Système d'exploitation cible: $1
% When the \var{-vd} switch is used, this line tells you what the target
% operating system is.
general_t_exepath=01003_T_Répertoire des fichiers exécutables: $1
% When the \var{-vt} switch is used, this line tells you where the compiler
% looks for its binaries.
general_t_unitpath=01004_T_Répertoire de recherche des unités: $1
% When the \var{-vt} switch is used, this line tells you where the compiler
% looks for compiled units. You can set this path with the \var{-Fu}
general_t_includepath=01005_T_Répertoire de recherche des fichiers inclus: $1
% When the \var{-vt} switch is used, this line tells you where the compiler
% looks for its include files (files used in \var{\{\$I xxx\}} statements).
% You can set this path with the \var{-I} option.
general_t_librarypath=01006_T_Répertoire de recherche des bibliothèques: $1
% When the \var{-vt} switch is used, this line tells you where the compiler
% looks for the libraries. You can set this path with the \var{-Fl} option.
general_t_objectpath=01007_T_Répertoire de recherche des fichiers objet: $1
% When the \var{-vt} switch is used, this line tells you where the compiler
% looks for object files you link in (files used in \var{\{\$L xxx\}} statements).
% You can set this path with the \var{-Fo} option.
general_i_abslines_compiled=01008_I_$1 lignes compilées, $2 sec$3
% When the \var{-vi} switch is used, the compiler reports the number
% of lines compiled, and the time it took to compile them (real time,
% not program time).
general_f_no_memory_left=01009_F_Plus de mémoire disponible
% The compiler doesn't have enough memory to compile your program. There are
% several remedies for this:
% \begin{itemize}
% \item If you're using the build option of the compiler, try compiling the
% different units manually.
% \item If you're compiling a huge program, split it up in units, and compile
% these separately.
% \item If the previous two don't work, recompile the compiler with a bigger
% heap (you can use the \var{-Ch} option for this, \seeo{Ch})
% \end{itemize}
general_i_writingresourcefile=01010_I_Écriture du fichier de ressource: $1
% This message is shown when the compiler writes the Resource String Table
% file containing all the resource strings for a program.
general_e_errorwritingresourcefile=01011_E_Écriture du fichier de chaînes de ressource: $1
% This message is shown when the compiler encountered an error when writing
% the Resource String Table file
general_i_fatal=01012_I_Fatal:
% Prefix for Fatal Errors
general_i_error=01013_I_Erreur:
% Prefix for Errors
general_i_warning=01014_I_Attention:
% Prefix for Warnings
general_i_note=01015_I_Note:
% Prefix for Notes
general_i_hint=01016_I_Conseil:
% Prefix for Hints
general_e_path_does_not_exist=01017_E_Le chemin "$1" n'existe pas
% The specified path does not exist.
general_f_compilation_aborted=01018_F_Compilation interrompue
% Compilation was aborted.
general_text_bytes_code=01019_bytes code
% The size of the generated executable code, in bytes.
general_text_bytes_data=01020_bytes data
% The size of the generated program data, in bytes.
general_i_number_of_warnings=01021_I_$1 avertissement(s) émis
% Total number of warnings issued during compilation.
general_i_number_of_hints=01022_I_$1 conseil(s) émis
% Total number of hints issued during compilation.
general_i_number_of_notes=01023_I_$1 note(s) émises
% Total number of notes issued during compilation.
% \end{description}
#
# Scanner
#
# 02063 is the last used one
#
% \section{Scanner messages.}
% This section lists the messages that the scanner emits. The scanner takes
% care of the lexical structure of the pascal file, i.e. it tries to find
% reserved words, strings, etc. It also takes care of directives and
% conditional compiling handling.
% \begin{description}
general_f_ioerror=01024_F_I/O error: $1
% During compilation an I/O error happened which allows no further compilation.
general_f_oserror=01025_F_Operating system error: $1
% During compilation an operating system error happened which allows no further compilation.
% \end{description}
#
# Scanner
#
# 02098 is the last used one
#
% \section{Scanner messages.}
% This section lists the messages that the scanner emits. The scanner takes
% care of the lexical structure of the pascal file, i.e. it tries to find
% reserved words, strings, etc. It also takes care of directives and
% conditional compilation handling.
% \begin{description}
scan_f_end_of_file=02000_F_Fin de fichier inattendue
% this typically happens in one of the following cases :
% \begin{itemize}
% \item The source file ends before the final \var{end.} statement. This
% happens mostly when the \var{begin} and \var{end} statements aren't
% balanced;
% \item An include file ends in the middle of a statement.
% \item A comment was not closed
% \end{itemize}
scan_f_string_exceeds_line=02001_F_Chaîne de caractères sur plus d'une ligne
% There is a missing closing ' in a string, so it occupies
% multiple lines.
scan_f_illegal_char=02002_F_Caractère "$1" illégal ($2)
% An illegal character was encountered in the input file.
scan_f_syn_expected=02003_F_Erreur de syntaxe, "$1" attendu mais "$2" trouvé
% This indicates that the compiler expected a different token than
% the one you typed. It can occur almost everywhere where you make a
% mistake against the pascal language.
scan_t_start_include_file=02004_T_Début de lecture du fichier include $1
% When you provide the \var{-vt} switch, the compiler tells you
% when it starts reading an included file.
scan_w_comment_level=02005_W_Commentaire de niveau $1 trouvé
% When the \var{-vw} switch is used, then the compiler warns you if
% it finds nested comments. Nested comments are not allowed in Turbo Pascal
% and can be a possible source of errors.
scan_n_ignored_switch=02008_N_Commutateur "$1" ignoré
% With \var{-vn} on, the compiler warns if it ignores a switch
scan_w_illegal_switch=02009_W_Commutateur "$1" illégal
% You included a compiler switch (i.e. \var{\{\$... \}}) which the compiler
% does not recognise
scan_w_switch_is_global=02010_W_Commutateur global mal placé
% The compiler switch is misplaced, and should be located at
% the start of the unit or program.
scan_e_illegal_char_const=02011_E_Constante de type char illégale
% This happens when you specify a character with its ASCII code, as in
% \var{\#96}, but the number is either illegal, or out of range.
scan_f_cannot_open_input=02012_F_Impossible d'ouvrir le fichier "$1"
% \fpc cannot find the program or unit source file you specified on the
% command line.
scan_f_cannot_open_includefile=02013_F_Impossible d'ouvrir le fichier include "$1"
% \fpc cannot find the source file you specified in a \var{\{\$include ..\}}
% statement.
scan_e_illegal_pack_records=02015_E_Paramètre d'alignement de record incorrect "$1"
% You are specifying the \var{\{\$PACKRECORDS n\} } or \var{\{\$ALIGN n\} }
% with an illegal value for \var{n}. For \$PACKRECORDS valid alignments are 1, 2, 4, 8, 16, 32, C,
% NORMAL, DEFAULT, and for \$ALIGN valid alignment are 1, 2, 4, 8, 16, 32, ON,
% OFF. Under mode MacPas \$ALIGN also supports MAC68K, POWER and RESET.
scan_e_illegal_pack_enum=02016_E_Paramètre de taille minimum d'énumération incorrect "$1"
% You are specifying the \var{\{\$PACKENUM n\}} with an illegal value for
% \var{n}. Only 1,2,4, NORMAL or DEFAULT are valid here.
scan_e_endif_expected=02017_E_$ENDIF attendu pour $1 $2 défini dans $3 à la ligne $4
% Your conditional compilation statements are unbalanced.
scan_e_preproc_syntax_error=02018_E_Erreur de syntaxe pendant l'interprétation d'une directive de compilation
% There is an error in the expression following the \var{\{\$if ..\}}, $ifc or $setc compiler
% directives.
scan_e_error_in_preproc_expr=02019_E_Évaluation d'une directive de compilation
% There is an error in the expression following the \var{\{\$if ..\}}, $ifc or $setc compiler
% directives.
scan_w_macro_cut_after_255_chars=02020_W_Le contenu d'une macro est tronqué à 255 caractères
% The contents of macros cannot be longer than 255 characters.
scan_e_endif_without_if=02021_E_ENDIF sans IF(N)DEF
% Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced.
scan_f_user_defined=02022_F_Défini par l'utilisateur : $1
% A user defined fatal error occurred. see also the \progref
scan_e_user_defined=02023_E_Défini par l'utilisateur : $1
% A user defined error occurred. see also the \progref
scan_w_user_defined=02024_W_Défini par l'utilisateur : $1
% A user defined warning occurred. see also the \progref
scan_n_user_defined=02025_N_Défini par l'utilisateur : $1
% A user defined note was encountered. see also the \progref
scan_h_user_defined=02026_H_Défini par l'utilisateur : $1
% A user defined hint was encountered. see also the \progref
scan_i_user_defined=02027_I_Défini par l'utilisateur : $1
% User defined information was encountered. see also the \progref
scan_e_keyword_cant_be_a_macro=02028_E_La redéfinition d'un mot réservé en tant que macro est dans effet
% You cannot redefine keywords with macros.
scan_f_macro_buffer_overflow=02029_F_Débordement de tampon lors de la lecture ou de l'expansion d'une macro
% Your macro or its result was too long for the compiler.
scan_w_macro_too_deep=02030_W_L'expansion des macros dépasse une profondeur de 16.
% When expanding a macro, macros have been nested to a level of 16.
% The compiler will expand no further, since this may be a sign that
% recursion is used.
scan_w_wrong_styled_switch=02031_W_Les commutateurs du compilateur ne sont pas supportés dans les commentaires de style //
% Compiler switches should be in normal pascal style comments.
scan_d_handling_switch=02032_D_Interprétation du commutateur "$1"
% When you set debugging info on (\var{-vd}) the compiler tells you when it
% is evaluating conditional compile statements.
scan_c_endif_found=02033_CL_ENDIF $1 trouvé
% When you turn on conditional messages(\var{-vc}), the compiler tells you
% where it encounters conditional statements.
scan_c_ifdef_found=02034_CL_IFDEF $1 trouvé, $2
% When you turn on conditional messages(\var{-vc}), the compiler tells you
% where it encounters conditional statements.
scan_c_ifopt_found=02035_CL_IFOPT $1 trouvé, $2
% When you turn on conditional messages(\var{-vc}), the compiler tells you
% where it encounters conditional statements.
scan_c_if_found=02036_CL_IF $1 trouvé, $2
% When you turn on conditional messages(\var{-vc}), the compiler tells you
% where it encounters conditional statements.
scan_c_ifndef_found=02037_CL_IFNDEF $1 trouvé, $2
% When you turn on conditional messages(\var{-vc}), the compiler tells you
% where it encounters conditional statements.
scan_c_else_found=02038_CL_ELSE $1 trouvé, $2
% When you turn on conditional messages(\var{-vc}), the compiler tells you
% where it encounters conditional statements.
scan_c_skipping_until=02039_CL_Passant jusqu'à...
% When you turn on conditional messages(\var{-vc}), the compiler tells you
% where it encounters conditional statements, and whether it is skipping or
% compiling parts.
scan_i_press_enter=02040_I_Appuyez sur <Entrée> pour continuer
% When the \var{-vi} switch is used, the compiler stops compilation
% and waits for the \var{Enter} key to be pressed when it encounters
% a \var{\{\$STOP\}} directive.
scan_w_unsupported_switch=02041_W_Commutateur "$1" non supporté
% When warnings are turned on (\var{-vw}) the compiler warns you about
% unsupported switches. This means that the switch is used in Delphi or
% Turbo Pascal, but not in \fpc
scan_w_illegal_directive=02042_W_Directive de compilation "$1" illégale
% When warings are turned on (\var{-vw}) the compiler warns you about
% unrecognised switches. For a list of recognised switches, \progref
scan_t_back_in=02043_T_De retour dans $1
% When you use (\var{-vt}) the compiler tells you when it has finished
% reading an include file.
scan_w_unsupported_app_type=02044_W_Type d'application non supportée : $1
% You get this warning, if you specify an unknown application type
% with the directive \var{\{\$APPTYPE\}}
scan_w_app_type_not_support=02045_W_$APPTYPE n'est pas supporté par l'OS cible
% The \var{\{\$APPTYPE\}} directive is supported by certain operating systems only.
scan_w_description_not_support=02046_W_DESCRIPTION n'est pas supporté par l'OS cible
% The \var{\{\$DESCRIPTION\}} directive is not supported on this target OS
scan_n_version_not_support=02047_N_VERSION non supporté par l'OS cible
% The \var{\{\$VERSION\}} directive is not supported on this target OS
scan_n_only_exe_version=02048_N_VERSION seulement pour les EXE et les DLL
% The \var{\{\$VERSION\}} directive is only used for executable or DLL sources.
scan_w_wrong_version_ignored=02049_W_Mauvais format de la directive VERSION "$1"
% The \var{\{\$VERSION\}} directive format is majorversion.minorversion
% where majorversion and minorversion are words.
scan_e_illegal_asmmode_specifier=02050_E_Style d'assembleur incorrect "$1"
% When you specify an assembler mode with the \var{\{\$ASMMODE xxx\}}
% the compiler didn't recognize the mode you specified.
scan_w_no_asm_reader_switch_inside_asm=02051_W_Changement de type d'interpréteur ASM à l'intérieur de code assembleur, $1 sera effectif seulement pour le prochain
% It is not possible to switch from one assembler reader to another
% inside an assembler block. The new reader will be used for next
% assembler statements only.
scan_e_wrong_switch_toggle=02052_E_Mauvais argument de commutateur, utilisez ON/OFF ou +/-
% You need to use ON or OFF or a + or - to toggle the switch
scan_e_resourcefiles_not_supported=02053_E_Fichiers de ressources non supportés pour cette cible
% The target you are compiling for doesn't support resource files.
scan_w_include_env_not_found=02054_W_Variable d'environment "$1" non trouvée
% The included environment variable can't be found in the environment, it will
% be replaced by an empty string instead.
scan_e_invalid_maxfpureg_value=02055_E_Valeur invalide pour nombre limite de variables en registre FPU
% Valid values for this directive are 0..8 and NORMAL/DEFAULT
scan_w_only_one_resourcefile_supported=02056_W_Un seul fichier de ressource est supporté pour cette cible
% The target you are compiling for supports only one resource file.
% The first resource file found is used, the others are discarded.
scan_w_macro_support_turned_off=02057_W_L'utilisation des macros à été désactivée
% A macro declaration has been found, but macro support is currently off,
% so the declaration will be ignored. To turn macro support on compile with
% -Sm on the commandline or add \{\$MACRO ON\} in the source
scan_e_invalid_interface_type=02058_E_Type d'interface spécifié incorrect. Les valeurs acceptées sont COM, CORBA et DEFAULT.
% The interface type that was specified is not supported
scan_w_appid_not_support=02059_W_APPID n'est supporté que pour PalmOS
% The \var{\{\$APPID\}} directive is only supported for the PalmOS target.
scan_w_appname_not_support=02060_W_APPNAME n'est supporté que pour PalmOS
% The \var{\{\$APPNAME\}} directive is only supported for the PalmOS target.
scan_e_string_exceeds_255_chars=02061_E_Les constantes chaîne de caractères ne peuvent dépasser 255 caractères
% A single string constant can contain at most 255 chars. Try splitting up the
% string in multiple smaller parts and concatenate them with a + operator.
scan_f_include_deep_ten=02062_F_La profondeur des inclusions de fichiers include dépasse 16.
% When including include files the files have been nested to a level of 16.
% The compiler will expand no further, since this may be a sign that
% recursion is used.
scan_e_too_many_push=02063_F_Trop de niveaux de PUSH
% A maximum of 20 levels is allowed. This error occurs only in mode MacPas.
scan_e_too_many_pop=02064_E_Un POP non précédé d'un PUSH
% This error occurs only in mode MacPas.
scan_e_error_macro_lacks_value=02065_E_Macro ou variable d´heure de compilation "$1" sans valeur
% Thus the conditional compile time expression cannot be evaluated.
scan_e_wrong_switch_toggle_default=02066_E_Mauvais argument de commutateur, utilisez ON/OFF/DEFAULT ou +/-/*
% You need to use ON or OFF or DEFAULT or a + or - or * to toggle the switch
scan_e_mode_switch_not_allowed=02067_E_Le commutateur de mode "$1" n'est pas autorisé ici
% A mode switch has already been encountered, or, in case of option -Mmacpas,
% a mode switch occur after UNIT.
scan_e_error_macro_undefined=02068_E_Macro ou variable d´heure de compilation "$1" non définie
% Thus the conditional compile time expression cannot be evaluated. Only in mode MacPas.
scan_e_utf8_bigger_than_65535=02069_E_Code UTF-8 supérieur à 65535 trouvé
% \fpc handles utf-8 strings internally as widestrings e.g. the char codes are limited to 65535
scan_e_utf8_malformed=02070_E_Chaîne UTF-8 malformée
% The given string isn't a valid UTF-8 string
scan_c_switching_to_utf8=02071_C_Signature UTF-8 trouvée, utilisation de l'encodage UTF-8
% The compiler found an UTF-8 encoding signature (\$ef, \$bb, \$bf) at the beginning of a file,
% so it interprets it as an UTF-8 file
scan_e_compile_time_typeerror=02072_E_Heure de compilation: $1 attendue mais $2 à $3 obtenue
% Type check of a compile time expression failed.
scan_n_app_type_not_support=02073_N_APPTYPE n'est pas supporté par l'OS cible
% The \var{\{\$APPTYPE\}} directive is supported by certain operating systems only.
scan_e_illegal_optimization_specifier=02074_E_Optimisation "$1" spécifiée incorrecte
% When you specify an optimization with the \var{\{\$OPTIMIZATION xxx\}}
% the compiler didn't recognize the optimization you specified.
scan_w_setpeflags_not_support=02075_W_SETPEFLAGS n'est pas supporté par l'OS cible
% The \var{\{\$SETPEFLAGS\}} directive is not supported by the target OS
scan_w_imagebase_not_support=02076_W_IMAGEBASE n'est pas supporté par l'OS cible
% The \var{\{\$IMAGEBASE\}} directive is not supported by the target OS
scan_w_minstacksize_not_support=02077_W_MINSTACKSIZE n'est pas supporté sur l'OS cible
% The \var{\{\$MINSTACKSIZE\}} directive is not supported by the target OS
scan_w_maxstacksize_not_support=02078_W_MAXSTACKSIZE n'est pas supporté sur l'OS cible
% The \var{\{\$MAXSTACKSIZE\}} directive is not supported by the target OS
% \end{description}
#
# Parser
#
# 03192 is the last used one
#
% \section{Parser messages}
% This section lists all parser messages. The parser takes care of the
% semantics of you language, i.e. it determines if your pascal constructs
% are correct.
% \begin{description}
scanner_e_illegal_warn_state=02079_E_Illegal state "$1" for $WARN directive
% Only ON and OFF can be used as state with a \var{\{\$WARN\}} compiler directive.
scan_e_only_packset=02080_E_Illegal set packing value
% Only 0, 1, 2, 4, 8, DEFAULT and NORMAL are allowed as packset parameters.
scan_w_pic_ignored=02081_W_PIC directive or switch ignored
% Several targets, such as \windows, do not support nor need PIC,
% so the PIC directive and switch are ignored.
scan_w_unsupported_switch_by_target=02082_W_The switch "$1" is not supported by the currently selected target
% Some compiler switches like \$E are not supported by all targets.
scan_w_frameworks_darwin_only=02084_W_Framework-related options are only supported for Darwin/Mac OS X
% Frameworks are not a known concept, or at least not supported by FPC,
% on operating systems other than Darwin/Mac OS X.
scan_e_illegal_minfpconstprec=02085_E_Illegal minimal floating point constant precision "$1"
% Valid minimal precisions for floating point constants are default, 32 and 64,
% which mean respectively minimal (usually 32 bit), 32 bit and 64 bit precision.
scan_w_multiple_main_name_overrides=02086_W_Overriding name of "main" procedure multiple times, was previously set to "$1"
% The name for the main entry procedure is specified more than once. Only the last
% name will be used.
scanner_w_illegal_warn_identifier=02087_W_Illegal identifier "$1" for $WARN directive
% Identifier is not known by a \var{\{\$WARN\}} compiler directive.
scanner_e_illegal_alignment_directive=02088_E_Illegal alignment directive
% The alignment directive is not valid. Either the alignment type is not known or the alignment
% value is not a power of two.
scanner_f_illegal_utf8_bom=02089_F_It is not possible to include a file that starts with an UTF-8 BOM in a module that uses a different code page
% All source code that is part of a single compilation entity (program, library, unit) must be encoded
% in the same code page
scanner_w_directive_ignored_on_target=02090_W_Directive "$1" is ignored for the current target platform
% Some directives are ignored for certain targets, such as changing the
% packrecords and packenum settings on managed platforms.
scan_w_unavailable_system_codepage=02091_W_Current system codepage "$1" is not available for the compiler. Switching default codepage back to "$2".
% The current system codepage is not known by the compiler.
% The compiler is compiled with support for several codepages built-in.
% The codepage of the operation system is not in that list. You will need to recompile
% the compiler with support for this codepage.
scan_w_setpeoptflags_not_support=02092_W_SETPEOPTFLAGS is not supported by the target OS
% The \var{\{\$SETPEOPTFLAGS\}} directive is not supported by the target OS.
scan_e_illegal_peflag=02093_E_Illegal argument for SETPEFLAGS
% The given argument for SETPEFLAGS is neither a correct named value nor an
% ordinal value
scan_e_illegal_peoptflag=02094_E_Illegal argument for SETPEOPTFLAGS
% The given argument for SETPEOPTFLAGS is neither a correct named value nor an
% ordinal value
scan_e_unsupported_switch=02095_E_Directive $1 is not supported on this target
% Not all compiler directives are supported on all targets.
scan_w_invalid_stacksize=02096_W_The specified stack size is not within the valid range for the platform. Setting the stack size ignored.
% The valid range for the stack size is 1024 - 67107839 on 32-bit and 64-bit
% platforms and 1024 - 65520 on 16-bit platforms. Additionally, for Turbo Pascal 7
% compatibility reasons, specifying a stack size of 65521 on 16-bit platforms
% actually sets the stack size to 65520.
scan_w_heapmax_lessthan_heapmin=02097_W_The specified HeapMax value is smaller than the HeapMin value. Setting HeapMax ignored.
% The HeapMax value (if specified) must be greater than or equal to the HeapMin
% value. Otherwise, the HeapMax value is ignored.
scan_e_illegal_hugepointernormalization=02098_E_Illegal argument for HUGEPOINTERNORMALIZATION
% The only allowed values for HUGEPOINTERNORMALIZATION are BORLANDC, MICROSOFTC
% and WATCOMC.
% \end{description}
#
# Parser
#
# 03339 is the last used one
#
% \section{Parser messages}
% This section lists all parser messages. The parser takes care of the
% semantics of you language, i.e. it determines if your Pascal constructs
% are correct.
% \begin{description}
parser_e_syntax_error=03000_E_Analyseur syntaxique - Erreur de syntaxe
% An error against the Turbo Pascal language was encountered. This happens
% typically when an illegal character is found in the sources file.
parser_e_dont_nest_interrupt=03004_E_Une procédure de type INTERRUPT ne peut pas être imbriquée
% An \var{INTERRUPT} procedure must be global.
parser_w_proc_directive_ignored=03005_W_Type procédure "$1" ignoré
% The specified procedure directive is ignored by FPC programs.
parser_e_no_overload_for_all_procs=03006_E_Toutes les déclaration de "$1" ne sont pas déclarées OVERLOAD
% When you want to use overloading using the \var{OVERLOAD} directive, then
% all declarations need to have \var{OVERLOAD} specified.
parser_e_export_name_double=03008_E_Nom de fonction exportée "$1" dupliqué
% Exported function names inside a specific DLL must all be different
parser_e_export_ordinal_double=03009_E_Index de fonction exportée "$1" dupliqué
% Exported function names inside a specific DLL must all be different
parser_e_export_invalid_index=03010_E_Index de fonction exportée invalide
% DLL function index must be in the range \var{1..\$FFFF}
parser_w_parser_reloc_no_debug=03011_W_Les DLL ou EXE relogeables sont incompatibles avec les informations de débogage, débogage désactivé.
% It is currently not possible to include debug information in a relocatable DLL.
parser_w_parser_win32_debug_needs_WN=03012_W_Pour permettre le débogage de code win32, utilisez l'option -WN
% Stabs info is wrong for relocatable DLL or EXES use -WN
% if you want to debug win32 executables.
parser_e_constructorname_must_be_init=03013_E_Le nom du constructeur doit être INIT
% You are declaring an object constructor with a name which is not \var{init}, and the
% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
parser_e_destructorname_must_be_done=03014_E_Le nom du destructeur doit être DONE
% You are declaring an object destructor with a name which is not \var{done}, and the
% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
parser_e_proc_inline_not_supported=03016_E_Procédure INLINE non supportée
% You tried to compile a program with C++ style inlining, and forgot to
% specify the \var{-Si} option (\seeo{Si}). The compiler doesn't support C++
% styled inlining by default.
parser_w_constructor_should_be_public=03018_W_Le constructeur devrait être public
% Constructors must be in the 'public' part of an object (class) declaration.
parser_w_destructor_should_be_public=03019_W_Le destructeur devrait être public
% Destructors must be in the 'public' part of an object (class) declaration.
parser_n_only_one_destructor=03020_N_Les classes ne doivent avoir qu'un seul destructeur
% You can declare only one destructor for a class.
parser_e_no_local_objects=03021_E_Les définitions de classes locales ne sont pas autorisées
% Classes must be defined globally. They cannot be defined inside a
% procedure or function
parser_f_no_anonym_objects=03022_F_Les définitions de classes anonymes sont interdites
% An invalid object (class) declaration was encountered, i.e. an
% object or class without methods that isn't derived from another object or
% class. For example:
% \begin{verbatim}
% Type o = object
% a : longint;
% end;
% \end{verbatim}
% will trigger this error.
parser_n_object_has_no_vmt=03023_N_L'objet "$1" n'a pas de VMT
% This is a note indicating that the declared object has no
% virtual method table.
parser_e_illegal_parameter_list=03024_E_Liste de paramètres illégale
% You are calling a function with parameters that are of a different type than
% the declared parameters of the function.
parser_e_wrong_parameter_size=03026_E_Mauvais nombre de paramètres spécifié
% There is an error in the parameter list of the function or procedure,
% the number of parameters is not correct.
parser_e_overloaded_no_procedure=03027_E_L'identificateur surchargé "$1" n'est pas une fonction
% The compiler encountered a symbol with the same name as an overloaded
% function, but it is not a function it can overload.
parser_e_overloaded_have_same_parameters=03028_E_Les fonctions surchargées ont les mêmes paramètres
% You're declaring overloaded functions, but with the same parameter list.
% Overloaded function must have at least 1 different parameter in their
% declaration.
parser_e_header_dont_match_forward=03029_E_L'en-tête de la fonction ne correspond pas à la déclaration anticipée "$1"
% You declared a function with same parameters but
% different result type or function modifiers.
parser_e_header_different_var_names=03030_E_L'entête de la fonction "$1" ne correspond pas à sa déclaration anticipée : le nom de variable change $2 => $3
% You declared the function in the \var{interface} part, or with the
% \var{forward} directive, but define it with a different parameter list.
parser_n_duplicate_enum=03031_N_Les valeurs d'une énumération doivent être en ordre croissant
% \fpc allows enumeration constructions as in C. Given the following
% declaration two declarations:
% \begin{verbatim}
% type a = (A_A,A_B,A_E:=6,A_UAS:=200);
% type a = (A_A,A_B,A_E:=6,A_UAS:=4);
% \end{verbatim}
% The second declaration would produce an error. \var{A\_UAS} needs to have a
% value higher than \var{A\_E}, i.e. at least 7.
parser_e_no_with_for_variable_in_other_segments=03033_E_With ne peut pas être utilisé avec les variables d'un autre segment
% With stores a variable locally on the stack,
% but this is not possible if the variable belongs to another segment.
parser_e_too_much_lexlevel=03034_E_Niveau d'inbrication de fonctions > 31
% You can nest function definitions only 31 times.
parser_e_range_check_error=03035_E_Erreur d'intervalle dans l'évaluation d'une constante
% The constants are out of their allowed range.
parser_w_range_check_error=03036_W_Erreur d'intervalle dans l'évaluation d'une constante
% The constants are out of their allowed range.
parser_e_double_caselabel=03037_E_Valeur dupliquée dans une instruction CASE
% You are specifying the same label 2 times in a \var{case} statement.
parser_e_case_lower_less_than_upper_bound=03038_E_Valeur max. inférieure à la valeur min. dans l'instruction CASE
% The upper bound of a \var{case} label is less than the lower bound and this
% is useless
parser_e_type_const_not_possible=03039_E_Les constantes typées de classes sont interdites
% You cannot declare a constant of type class or object.
parser_e_no_overloaded_procvars=03040_E_Les variables fonction de fonctions surchargées ne sont pas autorisées
% You are trying to assign an overloaded function to a procedural variable.
% This is not allowed
parser_e_invalid_string_size=03041_E_La longueur d'une chaîne doit être comprise entre 1 et 255
% The length of a shortstring in Pascal is limited to 255 characters. You are
% trying to declare a string with length lower than 1 or greater than 255
parser_w_use_extended_syntax_for_objects=03042_W_Utilisez la syntaxe étendue de NEW et DISPOSE pour les instances d'objet
% If you have a pointer \var{a} to a class type, then the statement
% \var{new(a)} will not initialize the class (i.e. the constructor isn't
% called), although space will be allocated. you should issue the
% \var{new(a,init)} statement. This will allocate space, and call the
% constructor of the object
parser_w_no_new_dispose_on_void_pointers=03043_W_L'usage de NEW ou DISPOSE pour des pointeurs non typés n'a pas de sens
parser_e_no_new_dispose_on_void_pointers=03044_E_L'usage de NEW ou DISPOSE pour des pointeurs non typés est impossible
% You cannot use \var{new(p)} or \var{dispose(p)} if \var{p} is an untyped pointer
% because no size is associated to an untyped pointer.
% Accepted for compatibility in \var{tp} and \var{delphi} modes.
parser_e_class_id_expected=03045_E_Identificateur de classe attendu
% This happens when the compiler scans a procedure declaration that contains
% a dot,
% i.e., a object or class method, but the type in front of the dot is not
% a known type.
parser_e_no_type_not_allowed_here=03046_E_Identificateur de type interdit ici
% You cannot use a type inside an expression.
parser_e_methode_id_expected=03047_E_Identificateur de méthode attendu
% This identifier is not a method.
% This happens when the compiler scans a procedure declaration that contains
% a dot, i.e., a object or class method, but the procedure name is not a
% procedure of this type.
parser_e_header_dont_match_any_member=03048_E_L'en-tête de la fonction ne correspond à aucune méthode de cette classe "$1"
% This identifier is not a method.
% This happens when the compiler scans a procedure declaration that contains
% a dot, i.e., a object or class method, but the procedure name is not a
% procedure of this type.
parser_d_procedure_start=03049_DL_procédure/fonction $1
% When using the \var{-vd} switch, the compiler tells you when it starts
% processing a procedure or function implementation.
parser_e_error_in_real=03050_E_Constante réelle illégale
% The compiler expects a floating point expression, and gets something else.
parser_e_fail_only_in_constructor=03051_E_FAIL ne peut être utilisé que dans un constructeur
% You are using the \var{fail} keyword outside a constructor method.
parser_e_no_paras_for_destructor=03052_E_Les destructeurs ne peuvent pas avoir de paramètres
% You are declaring a destructor with a parameter list. Destructor methods
% cannot have parameters.
parser_e_only_class_members_via_class_ref=03053_E_Only class methods, class properties and class variables can be referred with class references
% This error occurs in a situation like the following:
% \begin{verbatim}
% Type :
% Tclass = Class of Tobject;
%
% Var C : TClass;
%
% begin
% ...
% C.free
% \end{verbatim}
% \var{Free} is not a class method and hence cannot be called with a class
% reference.
parser_e_only_class_members=03054_E_Only class methods, class properties and class variables can be accessed in class methods
% This is related to the previous error. You cannot call a method of an object
% from inside a class method. The following code would produce this error:
% \begin{verbatim}
% class procedure tobject.x;
%
% begin
% free
% \end{verbatim}
% Because free is a normal method of a class it cannot be called from a class
% method.
parser_e_case_mismatch=03055_E_La constante et l'instruction CASE ne sont pas du même type
% One of the labels is not of the same type as the case variable.
parser_e_illegal_symbol_exported=03056_E_Le symbole ne peut pas être exporté depuis une bibliothèque
% You can only export procedures and functions when you write a library. You
% cannot export variables or constants.
parser_w_should_use_override=03057_W_Une méthode héritée est cachée par "$1"
% A method that is declared \var{virtual} in a parent class, should be
% overridden in the descendent class with the \var{override} directive. If you
% don't specify the \var{override} directive, you will hide the parent method;
% you will not override it.
parser_e_nothing_to_be_overridden=03058_E_Il n'y a pas de méthode dans la classe ancêtre que l'on peut surcharger : "$1"
% You are trying to \var{override} a virtual method of a parent class that does
% not exist.
parser_e_no_procedure_to_access_property=03059_E_Aucun membre n'est fourni pour accéder à la propriété
% You specified no \var{read} directive for a property.
parser_w_stored_not_implemented=03060_W_Directive de propriété stockée non encore implementée
% The \var{stored} directive is not yet implemented
parser_e_ill_property_access_sym=03061_E_Symbole illégal pour l'accès à la propriété
% There is an error in the \var{read} or \var{write} directives for an array
% property. When you declare an array property, you can only access it with
% procedures and functions. The following code would cause such an error.
% \begin{verbatim}
% tmyobject = class
% i : integer;
% property x [i : integer]: integer read I write i;
% \end{verbatim}
%
parser_e_cant_access_protected_member=03062_E_Impossible d'accéder aux champs "protected" d'un object ici
% Fields that are declared in a \var{protected} section of an object or class
% declaration cannot be accessed outside the module where the object is
% defined, or outside descendent object methods.
parser_e_cant_access_private_member=03063_E_Impossible d'accéder aux champs "private" d'un object ici
% Fields that are declared in a \var{private} section of an object or class
% declaration cannot be accessed outside the module where the class is
% defined.
parser_e_overridden_methods_not_same_ret=03066_E_Les méthodes surchargées doivent renvoyer le même type: "$2" est surchargée par "$1" qui retourne un type différent
% If you declare overridden methods in a class definition, they must
% have the same return type.
parser_e_dont_nest_export=03067_E_Les fonctions déclarées comme EXPORT ne peuvent pas être imbriquées
% You cannot declare a function or procedure within a function or procedure
% that was declared as an export procedure.
parser_e_methods_dont_be_export=03068_E_Les méthodes ne peuvent pas être EXPORTées
% You cannot declare a procedure that is a method for an object as
% \var{export}ed.
parser_e_call_by_ref_without_typeconv=03069_E_Les paramètres passés par adresse doivent être du même type que la déclaration: "$1" spécifié mais "$2" attendu
% When calling a function declared with \var{var} parameters, the variables in
% the function call must be of exactly the same type. There is no automatic
% type conversion.
parser_e_no_super_class=03070_E_Cette classe n'est pas un parent de la classe actuelle
% When calling inherited methods, you are trying to call a method of a non-related
% class. You can only call an inherited method of a parent class.
parser_e_self_not_in_method=03071_E_Self n'est possible que dans les méthodes
% You are trying to use the \var{self} parameter outside an object's method.
% Only methods get passed the \var{self} parameters.
parser_e_generic_methods_only_in_methods=03072_E_Une méthode ne peut être appelée avec son identificateur de classe qu'à partir d'une méthode
% A construction like \var{sometype.somemethod} is only allowed in a method.
parser_e_illegal_colon_qualifier=03073_E_Utilisation non valide de ':'
% You are using the format \var{:} (colon) 2 times on an expression that
% is not a real expression.
parser_e_illegal_set_expr=03074_E_Erreur d'intervalle dans un constructeur d'ensemble ou élément d'ensemble dupliqué
% The declaration of a set contains an error. Either one of the elements is
% outside the range of the set type, either two of the elements are in fact
% the same.
parser_e_pointer_to_class_expected=03075_E_Pointeur sur un objet attendu
% You specified an illegal type in a \var{new} statement.
% The extended syntax of \var{new} needs an object as a parameter.
parser_e_expr_have_to_be_constructor_call=03076_E_L'expression doit être un appel à un constructeur
% When using the extended syntax of \var{new}, you must specify the constructor
% method of the object you are trying to create. The procedure you specified
% is not a constructor.
parser_e_expr_have_to_be_destructor_call=03077_E_L'expression doit être un appel à un destructeur
% When using the extended syntax of \var{dispose}, you must specify the
% destructor method of the object you are trying to dispose of.
% The procedure you specified is not a destructor.
parser_e_invalid_record_const=03078_E_Mauvais ordre des éléments d'un record
% When declaring a constant record, you specified the fields in the wrong
% order.
parser_e_false_with_expr=03079_E_L'expression doit être une classe ou un record
% A \var{with} statement needs an argument that is of the type \var{record}
% or \var{class}. You are using \var{with} on an expression that is not of
% this type.
parser_e_void_function=03080_E_Les procédures ne peuvent pas retourner une valeur
% In \fpc, you can specify a return value for a function when using
% the \var{exit} statement. This error occurs when you try to do this with a
% procedure. Procedures cannot return a value.
parser_e_only_methods_allowed=03081_E_Les constructeurs, les destructeurs et les class operators doivent être des méthodes
% You're declaring a procedure as destructor, constructor or class operators, when the
% procedure isn't a class method.
parser_e_operator_not_overloaded=03082_E_L'opérateur n'est pas surchargé
% You're trying to use an overloaded operator when it is not overloaded for
% this type.
parser_e_no_such_assignment=03083_E_Impossible de surcharger l'affectation de types équivalents
% You can not overload assignment for types
% that the compiler considers as equal.
parser_e_overload_impossible=03084_E_Surcharge d'opérateur impossible
% The combination of operator, arguments and return type are
% incompatible.
parser_e_no_reraise_possible=03085_E_Redéclenchement d'exception impossible ici
% You are trying to raise an exception where it is not allowed. You can only
% raise exceptions in an \var{except} block.
parser_e_no_new_or_dispose_for_classes=03086_E_La syntaxe étendue de new ou dispose n'est pas autorisée pour une classe
% You cannot generate an instance of a class with the extended syntax of
% \var{new}. The constructor must be used for that. For the same reason, you
% cannot call \var{dispose} to de-allocate an instance of a class, the
% destructor must be used for that.
parser_e_procedure_overloading_is_off=03088_E_La surcharge de procédures est désactivée
% When using the \var{-So} switch, procedure overloading is switched off.
% Turbo Pascal does not support function overloading.
parser_e_overload_operator_failed=03089_E_Impossible de surcharger cet opérateur
% You are trying to overload an operator which cannot be overloaded.
% The following operators can be overloaded :
% \begin{verbatim}
% +, -, *, /, =, >, <, <=, >=, is, as, in, **, :=
% \end{verbatim}
parser_e_comparative_operator_return_boolean=03090_E_Un opératuer de comparaison doit retourner une valeur booléenne
% When overloading the \var{=} operator, the function must return a boolean
% value.
parser_e_only_virtual_methods_abstract=03091_E_Seules les méthodes virtuelles peuvent être abstraites
% You are declaring a method as abstract, when it is not declared to be
% virtual.
parser_f_unsupported_feature=03092_F_Utilisation d'une caractéristique non supportée !
% You're trying to force the compiler into doing something it cannot do yet.
parser_e_mix_of_classes_and_objects=03093_E_Le mélange de différents types d'objets (classe, objet, interface, etc.) est interdit
% You cannot derive \var{objects}, \var{classes}, \var{cppclasses} and \var{interfaces} interttwined . E.g.
% a class cannot have an object as parent and vice versa.
parser_w_unknown_proc_directive_ignored=03094_W_Une directive de procédure inconnue a due être ignorée : "$1"
% The procedure directive you specified is unknown.
parser_e_directive_only_one_var=03095_E_$1 can be associated with only one variable
% You cannot specify more than one variable before the \var{absolute}, \var{export}, \var{external},
% \var{weakexternal}, \var{public} and \var{cvar} directives.
% As a result, for example the following construct will provide this error:
% \begin{verbatim}
% Var Z : Longint;
% X,Y : Longint absolute Z;
% \end{verbatim}
parser_e_absolute_only_to_var_or_const=03096_E_absolute ne peut être associé qu'à une variable ou une constante
% The address of a \var{absolute} directive can only point to a variable or
% constant. Therefore, the following code will produce this error:
% \begin{verbatim}
% Procedure X;
%
% var p : longint absolute x;
% \end{verbatim}
%
parser_e_initialized_only_one_var=03097_E_Seule UNE variable peut être initialisée
% You cannot specify more than one variable with a initial value
% in Delphi mode.
parser_e_abstract_no_definition=03098_E_Les méthodes abstraites ne doivent pas avoir d'implementation
% Abstract methods can only be declared, you cannot implement them. They
% should be overridden by a descendant class.
parser_e_overloaded_must_be_all_global=03099_E_Cette fonction surchargée ne peut pas être locale (elle doit être exportée)
% You are defining a overloaded function in the implementation part of a unit,
% but there is no corresponding declaration in the interface part of the unit.
parser_w_virtual_without_constructor=03100_W_Des méthodes virtuelles sont utilisées sans constructeur dans "$1"
% If you declare objects or classes that contain virtual methods, you need
% to have a constructor and destructor to initialize them. The compiler
% encountered an object or class with virtual methods that doesn't have
% a constructor/destructor pair.
parser_c_macro_defined=03101_CL_Macro définie: $1
% When \var{-vc} is used, the compiler tells you when it defines macros.
parser_c_macro_undefined=03102_CL_Macro non défine: $1
% When \var{-vc} is used, the compiler tells you when it undefines macros.
parser_c_macro_set_to=03103_CL_Macro $1 définie à $2
% When \var{-vc} is used, the compiler tells you what values macros get.
parser_i_compiling=03104_I_Compilation de $1
% When you turn on information messages (\var{-vi}), the compiler tells you
% what units it is recompiling.
parser_u_parsing_interface=03105_U_Analyse syntaxique de l'interface de l'unité $1
% This tells you that the reading of the interface
% of the current unit starts
parser_u_parsing_implementation=03106_U_Analyse syntaxique de l'implémentation de $1
% This tells you that the code reading of the implementation
% of the current unit, library or program starts
parser_d_compiling_second_time=03107_DL_Compilation de $1 pour la seconde fois
% When you request debug messages (\var{-vd}) the compiler tells you what
% units it recompiles for the second time.
parser_e_no_property_found_to_override=03109_E_Aucune propriété à surcharger n'a été trouvée
% You want to override a property of a parent class, when there is, in fact,
% no such property in the parent class.
parser_e_only_one_default_property=03110_E_Une seule propriété par défaut est autorisée
% You specified a property as \var{Default}, but the class already has a
% default property, and a class can have only one default property.
parser_e_property_need_paras=03111_E_La propriété par défaut doit être de type tableau
% Only array properties of classes can be made \var{default} properties.
parser_e_constructor_cannot_be_not_virtual=03112_E_Les constructeurs virtuels ne sont possibles que pour les classes
% You cannot have virtual constructors in objects. You can only have them
% in classes.
parser_e_no_default_property_available=03113_E_Pas de propriété par défaut disponible
% You are trying to access a default property of a class, but this class (or one of
% its ancestors) doesn't have a default property.
parser_e_cant_have_published=03114_E_La classe ne peut pas avoir une section "published", utilisez le commutateur {$M+}
% If you want a \var{published} section in a class definition, you must
% use the \var{\{\$M+\}} switch, whch turns on generation of type
% information.
parser_e_forward_declaration_must_be_resolved=03115_E_La déclaration anticipée de la classe "$1" doit être résolue ici pour pouvoir utiliser la classe comme ancêtre
% To be able to use an object as an ancestor object, it must be defined
% first. This error occurs in the following situation:
% \begin{verbatim}
% Type ParentClas = Class;
% ChildClass = Class(ParentClass)
% ...
% end;
% \end{verbatim}
% Where \var{ParentClass} is declared but not defined.
parser_e_no_local_operator=03116_E_Les opérateurs locaux ne sont pas supportés
% You cannot overload locally, i.e. inside procedures or function
% definitions.
parser_e_proc_dir_not_allowed_in_interface=03117_E_La directive de procédure "$1" n'est pas autorisée dans la section interface
% This procedure directive is not allowed in the \var{interface} section of
% a unit. You can only use it in the \var{implementation} section.
parser_e_proc_dir_not_allowed_in_implementation=03118_E_La directive de procédure "$1" n'est pas autorisée dans la section implementation
% This procedure directive is not defined in the \var{implementation} section of
% a unit. You can only use it in the \var{interface} section.
parser_e_proc_dir_not_allowed_in_procvar=03119_E_La directive de procédure "$1" n'est pas autorisée dans la déclaration
% This procedure directive cannot be part of a procedural or function
% type declaration.
parser_e_function_already_declared_public_forward=03120_E_La fonction "$1" est déjà déclarée comme Public ou Forward
% You will get this error if a function is defined as \var{forward} twice.
% Or it is once in the \var{interface} section, and once as a \var{forward}
% declaration in the \var{implmentation} section.
parser_e_not_external_and_export=03121_E_Impossible d'utiliser à la fois EXPORT et EXTERNAL
% These two procedure directives are mutually exclusive
parser_n_not_supported_for_inline=03123_N_"$1" n'est pas encore supporté à l'intérieur de procédures/fonctions INLINE
% Inline procedures don't support this declaration.
parser_h_inlining_disabled=03124_H_Inlining désactivé
% Inlining of procedures is disabled.
parser_i_writing_browser_log=03125_I_Ecriture du Browser log $1
% When information messages are on, the compiler warns you when it
% writes the browser log (generated with the \var{\{\$Y+ \}} switch).
parser_h_maybe_deref_caret_missing=03126_H_Le déréférencement du pointeur semble manquer
% The compiler thinks that a pointer may need a dereference.
parser_f_assembler_reader_not_supported=03127_F_Lecteur de code assembleur sélectionné non supporté
% The selected assembler reader (with \var{\{\$ASMMODE xxx\}} is not
% supported. The compiler can be compiled with or without support for a
% particular assembler reader.
parser_e_proc_dir_conflict=03128_E_La directive de procédure "$1" entre en conflit avec d'autres directives
% You specified a procedure directive that conflicts with other directives.
% for instance \var{cdecl} and \var{pascal} are mutually exclusive.
parser_e_call_convention_dont_match_forward=03129_E_La convention d'appel ne correspond pas à la déclaration anticipée
% This error happens when you declare a function or procedure with
% e.g. \var{cdecl;} but omit this directive in the implementation, or vice
% versa. The calling convention is part of the function declaration, and
% must be repeated in the function definition.
parser_e_property_cant_have_a_default_value=03131_E_Cette propriété ne peut pas avoir de valeur par défaut
% Set properties or indexed properties cannot have a default value.
parser_e_property_default_value_must_const=03132_E_La valeur par défaut d'une propriété doit être une constante
% The value of a \var{default} declared property must be known at compile
% time. The value you specified is only known at run time. This happens
% .e.g. if you specify a variable name as a default value.
parser_e_cant_publish_that=03133_E_Ce symbole ne peut pas être "published", il ne peut être qu'une classe
% Only class type variables can be in a \var{published} section of a class
% if they are not declared as a property.
parser_e_cant_publish_that_property=03134_E_Ce genre de propriété ne peut pas être PUBLISHED
% Properties in a \var{published} section cannot be array properties.
% they must be moved to public sections. Properties in a \var{published}
% section must be an ordinal type, a real type, strings or sets.
parser_e_empty_import_name=03136_W_Un nom d'import est requis
% Some targets need a name for the imported procedure or a \var{cdecl} specifier
parser_e_division_by_zero=03138_E_Division par zéro
% There is a division by zero encounted
parser_e_invalid_float_operation=03139_E_Opération en virgule flottante invalide
% An operation on two real type values produced an overflow or a division
% by zero.
parser_e_array_lower_less_than_upper_bound=03140_E_Limite supérieure de l'intervalle plus petite que la limite inférieure
% The upper bound of a an array declaration is less than the lower bound and this
% is not possible
parser_w_string_too_long=03141_W_La chaîne "$1" est plus longue que $2
% The size of the constant string is larger than the size you specified in
% string type definition
parser_e_string_larger_array=03142_E_Longueur de chaîne supérieure à la longueur d'un tableau de caractères
% The size of the constant string is larger than the size you specified in
% the array[x..y] of char definition
parser_e_ill_msg_expr=03143_E_Expression illégale après la directive Message
% \fpc supports only integer or string values as message constants
parser_e_ill_msg_param=03144_E_Les gestionnaires de message ne peuvent accepter qu'un paramètre par référence
% A method declared with the \var{message}-directive as message handler
% can take only one parameter which must be declared as call by reference
% Parameters are declared as call by reference using the \var{var}-directive
parser_e_duplicate_message_label=03145_E_Message dupliqué dans un objet ou une classe: "%1"
% A label for a message is used twice in one object/class
parser_e_self_in_non_message_handler=03146_E_Self ne peut être qu'un paramètre explicite dans les gestionnaires de message
% The self parameter can only be passed explicitly to a method which
% is declared as message handler.
parser_e_threadvars_only_sg=03147_E_Les variables de Threads peuvent seulement être statiques ou globales
% Threadvars must be static or global, you can't declare a thread
% local to a procedure. Local variables are always local to a thread,
% because every thread has its own stack and local variables
% are stored on the stack
parser_f_direct_assembler_not_allowed=03148_F_Assembleur direct non supporté pour la sortie binaire
% You can't use direct assembler when using a binary writer, choose an
% other outputformat or use another assembler reader
parser_w_no_objpas_use_mode=03149_W_Ne chargez pas l'unité OBJPAS manuellement, utilisez de préférence \{\$mode Objfpc\} ou \{\$mode Delphi\}
% You are trying to load the ObjPas unit manually from a uses clause. This is
% not a good idea. Use the \var{\{\$mode objfpc\}} or
% \var{\{\$mode delphi\}}
% directives which load the unit automatically
parser_e_no_object_override=03150_E_OVERRIDE ne peut pas être utilisé avec des objets
% Override is not supported for objects, use \var{virtual} instead to override
% a method of a parent object
parser_e_cant_use_inittable_here=03151_E_Les types de données nécessitant une initialisation/finalisation ne peuvent pas être utilisés dans des records variants
% Some data type (e.g. \var{ansistring}) needs initialization/finalization
% code which is implicitly generated by the compiler. Such data types
% can't be used in the variant part of a record.
parser_e_resourcestring_only_sg=03152_E_Les chaînes de ressource ne peuvent être que statiques ou globales
% Resourcestring can not be declared local, only global or using the static
% directive.
parser_e_exit_with_argument_not__possible=03153_E_Exit avec un argument ne peut pas être utilisé ici
% an exit statement with an argument for the return value can't be used here, this
% can happen e.g. in \var{try..except} or \var{try..finally} blocks
parser_e_stored_property_must_be_boolean=03154_E_Le type du symbole STORED doit être un booléen
% If you specify a storage symbol in a property declaration, it must be of
% the type boolean
parser_e_ill_property_storage_sym=03155_E_Ce symbole n'est pas admis comme symbole STORED
% You can't use this type of symbol as storage specifier in property
% declaration. You can use only methods with the result type boolean,
% boolean class fields or boolean constants
parser_e_only_publishable_classes_can_be_published=03156_E_Only classes which are compiled in $M+ mode can be published
% A class-typed field in the published section of a class can only be a class which was
% compiled in \var{\{\$M+\}} or which is derived from such a class. Normally
% such a class should be derived from \var{TPersistent}.
parser_e_proc_directive_expected=03157_E_Directive de procédure attendue
% This error is triggered when you have a \var{\{\$Calling\}} directive without
% a calling convention specified.
% It also happens when declaring a procedure in a const block and you
% used a ; after a procedure declaration which must be followed by a
% procedure directive.
% Correct declarations are:
% \begin{verbatim}
% const
% p : procedure;stdcall=nil;
% p : procedure stdcall=nil;
% \end{verbatim}
parser_e_invalid_property_index_value=03158_E_La valeur d'un index de propriété doit être de type scalaire
% The value you use to index a property must be of an ordinal type, for
% example an integer or enumerated type.
parser_e_procname_to_short_for_export=03159_E_Nom de procédure trop court pour être exporté
% The length of the procedure/function name must be at least 2 characters
% long. This is because of a bug in dlltool which doesn't parse the .def
% file correct with a name of length 1.
parser_e_dlltool_unit_var_problem=03160_E_Impossible de créer une entrée DEFFILE pour des variables globales d'unité
parser_e_dlltool_unit_var_problem2=03161_E_Compilez sans l'option -WD
% You need to compile this file without the -WD switch on the
% commandline
parser_f_need_objfpc_or_delphi_mode=03162_F_Vous devez utilisez le mode ObjFpc (-S2) ou Delphi (-Sd) pour compiler ce module
% You need to use \{\$mode objfpc\} or \{\$mode delphi\} to compile this file.
% Or use the equivalent commandline switches -S2 or -Sd.
parser_e_no_export_with_index_for_target=03163_E_Impossible d'exporter avec un index sous $1
% Exporting of functions or procedures with a specified index is not
% supported on this target.
parser_e_no_export_of_variables_for_target=03164_E_L'export de variables n'est pas supporté sous $1
% Exporting of variables is not supported on this target.
parser_e_improper_guid_syntax=03165_E_Syntaxe GUID incorrecte
% The GUID indication does not have the proper syntax. It should be of the form
% \begin{verbatim}
% {XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX}
% \end{verbatim}
% Where each \var{X} represents a hexadecimal digit.
parser_w_interface_mapping_notfound=03168_W_Impossible de trouver la procédure nommée "$1" nécessaire à l'implémentation de $2.$3
% The compiler cannot find a suitable procedure which implements the given method of an interface.
% A procedure with the same name is found, but the arguments do not match.
parser_e_interface_id_expected=03169_E_Identificateur d'interface attendu
% This happens when the compiler scans a \var{class} declaration that contains
% \var{interface} function name mapping code like this:
% \begin{verbatim}
% type
% TMyObject = class(TObject, IDispatch)
% function IUnknown.QueryInterface=MyQueryInterface;
% ....
% \end{verbatim}
% and the \var{interface} before the dot not listed in the inheritance list.
parser_e_type_cant_be_used_in_array_index=03170_E_Le type "$1" ne peut être utilisé comme indice de tableau
% Types like \var{qword} or \var{int64} aren't allowed as array index type
parser_e_no_con_des_in_interfaces=03171_E_Constructeurs et destructeurs ne sont pas autorisés dans les interfaces
% Constructor and destructor declarations aren't allowed in interface
% In the most cases the method \var{QueryInterface} of \var{IUnknown} can
% be used to create a new interface.
parser_e_no_access_specifier_in_interfaces=03172_E_Les descripteurs de portée ne peuvent pas être utilisés dans les INTERFACES
% The access specifiers \var{public}, \var{private}, \var{protected} and
% \var{pusblished} can't be used in interfaces because all methods
% of an interfaces must be public.
parser_e_no_vars_in_interfaces=03173_E_Une interface ne peut pas contenir de propriétés
% Declarations of fields aren't allowed in interfaces. An interface
% can contain only methods
parser_e_no_local_proc_external=03174_E_Impossible de déclarer une procédure locale comme EXTERNAL
% Declaring local procedures as external is not possible. Local procedures
% get hidden parameters that will make the chance of errors very high
parser_w_skipped_fields_before=03175_W_Certaines propriétés avant "$1" n'ont pas été initialisées
% In Delphi mode, not all fields of a typed constant record have to be
% initialized, but the compiler warns you when it detects such situations.
parser_e_skipped_fields_before=03176_E_Certaines propriétés situées avant "$1" n'ont pas été initialisées
% In all syntax modes but Delphi mode, you can't leave some fields uninitialized
% in the middle of a typed constant record
parser_w_skipped_fields_after=03177_W_Certaines propriétés après "$1" n'ont pas été initialisées
% You can leave some fields at the end of a type constant record uninitialized
% (the compiler will initialize them to zero automatically). This may be the cause
% of subtle problems.
parser_e_varargs_need_cdecl_and_external=03178_E_Directive VarArgs sans CDecl ni External
% The varargs directive can only be used with procedures or functions
% that are declared with \var{cdecl} and \var{external} directives. The varargs directive
% is only meant to provide a compatible interface to C functions like printf.
parser_e_self_call_by_value=03179_E_Self doit être un paramètre normal (appel par valeur)
% You can't declare self as a const or var parameter, it must always be
% a call-by-value parameter
parser_e_interface_has_no_guid=03180_E_L'interface "$1" n'a pas d'identification d'interface
% When you want to assign an interface to a constant, then the interface
% must have a GUID value set.
parser_e_illegal_field_or_method=03181_E_Champ de classe ou identificateur de méthode "$1" inconnu
% Properties must refer to a field or method in the same class.
parser_w_proc_overriding_calling=03182_W_Surcharge de la convention d'appel "$1" avec "$2"
% There are two directives in the procedure declaration that specify a calling
% convention. Only the last directive will be used
parser_e_no_procvarobj_const=03183_E_Les constantes typées de la forme "procedure of object" ne peuvent être initialisées qu'avec NIL
% You can't assign the address of a method to a typed constant which has a
% 'procedure of object' type, because such a constant requires two addresses:
% that of the method (which is known at compile time) and that of the object or
% class instance it operates on (which can not be known at compile time).
parser_e_default_value_only_one_para=03184_E_Une valeur par défaut ne peut être affectée qu'à un paramètre
% It is not possible to specify a default value for several parameters at once.
% The following is invalid:
% \begin{verbatim}
% Procedure MyProcedure (A,B : Integer = 0);
% \end{verbatim}
% Instead, this should be declared as
% \begin{verbatim}
% Procedure MyProcedure (A : Integer = 0; B : Integer = 0);
% \end{verbatim}
parser_e_default_value_expected_for_para=03185_E_Paramètre par défaut requis pour "$1"
% The specified parameter requires a default value.
parser_w_unsupported_feature=03186_W_Fonctionnalité non supportée
% You're trying to force the compiler into doing something it cannot do yet.
parser_h_c_arrays_are_references=03187_H_Les tableaux C sont passés par référence
% Any array passed to a C functions is passed
% by a pointer (i.e. by reference).
parser_e_C_array_of_const_must_be_last=03188_E_Un tableau de constantes C doit être le dernier argument
% You can not add any other argument after an \var{array of const} for
% \var{cdecl} functions, as the size pushed on stack for this argument is
% not known.
parser_h_type_redef=03189_H_Redéfinition du Type "$1"
% This is an indicator that a previously declared type is
% being redefined as something else. This may, or may not
% be, a cause for errors.
parser_w_cdecl_has_no_high=03190_W_les fonctions cdecl n'ont pas de paramètre implicite
% Functions declared with cdecl modifier do not pass an extra implicit parameter.
parser_w_cdecl_no_openstring=03191_W_Les fonctions cdecl n'acceptent pas les chaînes ouvertes
% Openstring is not supported for cdecl'ared functions.
parser_e_initialized_not_for_threadvar=03192_E_Impossible d'initialiser des variables de thread
% Variables declared as threadvar can not be initialized with a default value.
% The variables will always be filled with zero at the start of a new thread.
parser_e_msg_only_for_classes=03193_E_La directive Message n'est autorisée que dans les classes
% The message directive is only supported for Class types.
parser_e_procedure_or_function_expected=03194_E_Procédure ou foncction attendue
% A class method can only be specified for procedures and functions.
parser_e_illegal_calling_convention=03195_W_Directive de convention d'appel ignorée: "$1"
% Some calling conventions are supported only by certain CPUs. I.e. most non-i386 ports support
% only the standard ABI calling convention of the CPU.
parser_e_no_object_reintroduce=03196_E_REINTRODUCE ne peut pas être utilisé avec des objets
% \var{reintroduce} is not supported for objects.
parser_e_paraloc_only_one_para=03197_E_Chaque argument doit avoir son propre emplacement
% If locations for arguments are specified explicitly as it is required by
% some syscall conventions, each argument must have it's only location, things
% like \var{procedure p(i,j : longint 'r1');} aren't allowed
parser_e_paraloc_all_paras=03198_E_Chaque argument doit avoir un emplacement explicite
% If one argument has an explicit argument location, all arguments of a procedure
% must have one.
parser_e_illegal_explicit_paraloc=03199_E_Emplacement d'argument inconnu
% The location specified for an argument isn't recognized by the compiler
parser_e_32bitint_or_pointer_variable_expected=03200_E_Variable entière sur 32 bits ou pointeur attendu
% The libbase for MorphOS/AmigaOS can be give only as \var{longint}, \var{dword} or any pointer variable.
parser_e_goto_outside_proc=03201_E_Les instructions Goto ne sont pas autorisées entre procédures différentes
% It isn't allowed to use the \var{goto} statements referencing labels outside the
% current procedure. The following example shows the problem:
% \begin{verbatim}
% ...
% procedure p1;
% label
% l1;
%
% procedure p2;
% begin
% goto l1; // This goto ISN'T allowed
% end;
%
% begin
% p2
% l1:
% end;
% ...
%
% \end{verbatim}
parser_f_too_complex_proc=03202_F_Procédure trop complexe, nécessite trop de registres
% Your procedure body is too long for the compiler. You should split the
% procedure into multiple smaller procedures.
parser_e_illegal_expression=03203_E_Expression illégale
% This can occur under many circumstances. Mostly when trying to evaluate
% constant expressions.
parser_e_invalid_integer=03204_E_Expression entière incorrecte
% You made an expression which isn't an integer, and the compiler expects the
% result to be an integer.
parser_e_invalid_qualifier=03205_E_Qualificateur incorrect
% One of the following is happening :
% \begin{itemize}
% \item You're trying to access a field of a variable that is not a record.
% \item You're indexing a variable that is not an array.
% \item You're dereferencing a variable that is not a pointer.
% \end{itemize}
parser_e_upper_lower_than_lower=03206_E_Limite haute < limite basse
% You are declaring a subrange, and the lower limit is higher than the high
% limit of the range.
parser_e_macpas_exit_wrong_param=03207_E_Le paramètre de sortie doit être le nom de la procédure dans laquelle il est utilisé
% Non local exit is not allowed. This error occurs only in mode MacPas.
parser_e_illegal_assignment_to_count_var=03208_E_Affectation illégale à la variable de boucle for "$1"
% The type of a \var{for} loop variable must be an ordinal type.
% Loop variables cannot be reals or strings. You can also not assign values to
% loop variables inside the loop (except in Delphi and TP modes). Use a while or
% repeat loop instead if you need to do something like that, since those
% constructs were built for that.
parser_e_no_local_var_external=03209_E_Impossible de déclarer une variable locale comme EXTERNAL
% Declaring local variables as external is not allowed. Only global variables can reference
% to external variables.
parser_e_proc_already_external=03210_E_Procédure déjà déclarée EXTERNAL
% The procedure is already declared with the EXTERNAL directive in an interface or
% forward declaration.
parser_w_implicit_uses_of_variants_unit=03211_W_Utilisation implicite de l'unité Variants
% The Variant type is used in the unit without any used unit using the Variants unit. The
% compiler has implicitly added the Variants unit to the uses list. To remove this warning
% the Variants unit needs to be added to the uses statement.
parser_e_no_static_method_in_interfaces=03212_E_Les méthodes de classe et les méthodes statiques ne peuvent pas être utilisées dans les interfaces
% The specifier \var{class} and directive \var{static} can't be used in interfaces
% because all methods of an interfaces must be public.
parser_e_arithmetic_operation_overflow=03213_E_Dépassement dans une opération arithmétique
% An operation on two integers values produced an overflow
parser_e_protected_or_private_expected=03214_E_Protected ou private attendu
% \var{strict} can be only used together with \var{protected} or \var{private}.
parser_e_illegal_slice=03215_E_SLICE ne peut pas être utilisée en dehors d'une liste de paramètres
% \var{slice} can be used only for arguments accepting an open array parameter
parser_e_dispinterface_cant_have_parent=03216_E_Une DISPINTERFACE ne peut pas avoir de classe parent
% A DISPINMTERFACE is a special type of interface which can't have a parent class
parser_e_dispinterface_needs_a_guid=03217_E_Une DISPINTERFACE requiert un GUID
% A DISPINMTERFACE always needs an interface identification
parser_w_overridden_methods_not_same_ret=03218_W_Les méthodes surchargées doivent avoir un type de résultat similaire. Ce code peut "crasher", il dépend d'un bug de l'analyseur syntaxique de Delphi ("$2" est surchargé par "$1" qui a un type de résultat différent)
% If you declare overridden methods in a class definition, they must
% have the same return type. Some versions of Delphi allow you to change the
% return type of interface methods, and even to change procedures into
% functions, but the resulting code may crash depending on the types used
% and the way the methods are called.
parser_e_dispid_must_be_ord_const=03219_E_Les Dispatch ID doivent être des constantes scalaires
% \end{description}
#
# Type Checking
#
# 04049 is the last used one
#
% \section{Type checking errors}
% This section lists all errors that can occur when type checking is
% performed.
% \begin{description}
parser_e_array_range_out_of_bounds=03220_E_The range of the array is too large
% Regardless of the size taken up by its elements, an array cannot have more
% than high(ptrint) elements. Additionally, the range type must be a subrange
% of ptrint.
parser_e_packed_element_no_var_addr=03221_E_The address cannot be taken of bit packed array elements and record fields
% If you declare an array or record as \var{packed} in Mac Pascal mode
% (or as \var{packed} in any mode with \var{\{\$bitpacking on\}}), it will
% be packed at the bit level. This means it becomes impossible to take addresses
% of individual array elements or record fields. The only exception to this rule
% is in the case of packed arrays elements whose packed size is a multiple of 8 bits.
parser_e_packed_dynamic_open_array=03222_E_Dynamic arrays cannot be packed
% Only regular (and possibly in the future also open) arrays can be packed.
parser_e_packed_element_no_loop=03223_E_Bit packed array elements and record fields cannot be used as loop variables
% If you declare an array or record as \var{packed} in Mac Pascal mode
% (or as \var{packed} in any mode with \var{\{\$bitpacking on\}}), it will
% be packed at the bit level. For performance reasons, they cannot be
% used as loop variables.
parser_e_type_var_const_only_in_records_and_classes=03224_E_VAR, TYPE and CONST are allowed only in records, objects and classes
% The usage of VAR, TYPE and CONST to declare new types inside an object is allowed only inside
% records, objects and classes.
parser_e_cant_create_generics_of_this_type=03225_E_This type cannot be a generic
% Only Classes, Objects, Interfaces and Records are allowed to be used as generic.
parser_w_no_lineinfo_use_switch=03226_W_Don't load LINEINFO unit manually, Use the -gl compiler switch instead
% Do not use the \file{lineinfo} unit directly, Use the \var{-gl} switch which
% automatically adds the correct unit for reading the selected type of debugging
% information. The unit that needs to be used depends on the type of
% debug information used when compiling the binary.
parser_e_no_funcret_specified=03227_E_No function result type specified for function "$1"
% The first time you declare a function you have to declare it completely,
% including all parameters and the result type.
parser_e_special_onlygenerics=03228_E_Specialization is only supported for generic types
% Types which are not generics cannot be specialized.
parser_e_no_generics_as_params=03229_E_Generics cannot be used as parameters when specializing generics
% When specializing a generic, only non-generic types can be used as parameters.
parser_e_type_object_constants=03230_E_Constants of objects containing a VMT are not allowed
% If an object requires a VMT either because it contains a constructor or virtual methods,
% it's not allowed to create constants of it. In TP and Delphi mode this is allowed
% for compatibility reasons.
parser_e_label_outside_proc=03231_E_Taking the address of labels defined outside the current scope isn't allowed
% It isn't allowed to take the address of labels outside the
% current procedure.
parser_e_initialized_not_for_external=03233_E_Cannot initialize variables declared as external
% Variables declared as external cannot be initialized with a default value.
parser_e_illegal_function_result=03234_E_Illegal function result type
% Some types like file types cannot be used as function result.
parser_e_no_common_type=03235_E_No common type possible between "$1" and "$2"
% To perform an operation on integers, the compiler converts both operands
% to their common type, which appears to be an invalid type. To determine the
% common type of the operands, the compiler takes the minimum of the minimal values
% of both types, and the maximum of the maximal values of both types. The common
% type is then minimum..maximum.
parser_e_no_generics_as_types=03236_E_Generics without specialization cannot be used as a type for a variable
% Generics must be always specialized before being used as variable type.
parser_w_register_list_ignored=03237_W_Register list is ignored for pure assembler routines
% When using pure assembler routines, the list with modified registers is ignored.
parser_e_implements_must_be_class_or_interface=03238_E_Implements property must have class or interface type
% A property which implements an interface must be of type class or interface.
parser_e_implements_must_have_correct_type=03239_E_Implements-property must implement interface of correct type, found "$1" expected "$2"
% A property which implements an interface actually implements a different interface.
parser_e_implements_must_read_specifier=03240_E_Implements-property must have read specifier
% A property which implements an interface must have at least a read specifier.
parser_e_implements_must_not_have_write_specifier=03241_E_Implements-property must not have write-specifier
% A property which implements an interface may not have a write specifier.
parser_e_implements_must_not_have_stored_specifier=03242_E_Implements-property must not have stored-specifier
% A property which implements an interface may not have a stored specifier.
parser_e_implements_uses_non_implemented_interface=03243_E_Implements-property used on unimplemented interface: "$1"
% The interface which is implemented by a property is not an interface implemented by the class.
parser_e_unsupported_real=03244_E_Floating point not supported for this target
% The compiler parsed a floating point expression, but it is not supported.
parser_e_class_doesnt_implement_interface=03245_E_Class "$1" does not implement interface "$2"
% The delegated interface is not implemented by the class given in the implements clause.
parser_e_class_implements_must_be_interface=03246_E_Type used by implements must be an interface
% The \var{implements} keyword must be followed by an interface type.
parser_e_cant_export_var_different_name=03247_E_Variables cannot be exported with a different name on this target, add the name to the declaration using the "export" directive (variable name: $1, declared export name: $2)
% On most targets it is not possible to change the name under which a variable
% is exported inside the \var{exports} statement of a library.
% In that case, you have to specify the export name at the point where the
% variable is declared, using the \var{export} and \var{alias} directives.
parser_e_weak_external_not_supported=03248_E_Weak external symbols are not supported for the current target
% A "weak external" symbol is a symbol which may or may not exist at (either static
% or dynamic) link time. This concept may not be available (or implemented yet)
% on the current cpu/OS target.
parser_e_forward_mismatch=03249_E_Forward type definition does not match
% Classes and interfaces being defined forward must have the same type
% when being implemented. A forward interface cannot be changed into a class.
parser_n_ignore_lower_visibility=03250_N_Virtual method "$1" has a lower visibility ($2) than parent class $3 ($4)
% The virtual method overrides an method that is declared with a higher visibility. This might give
% unexpected results. E.g., in case the new visibility is private then a call to ``inherited'' in a
% new child class will call the higher-visible method in a parent class and ignores the private method.
parser_e_field_not_allowed_here=03251_E_Fields cannot appear after a method or property definition, start a new visibility section first
% Once a method or property has been defined in a class or object, you cannot define any fields afterwards
% without starting a new visibility section (such as \var{public}, \var{private}, etc.). The reason is
% that otherwise the source code can appear ambiguous to the compiler, since it is possible to use modifiers
% such as \var{default} and \var{register} also as field names.
parser_e_no_local_para_def=03252_E_Parameters or result types cannot contain local type definitions. Use a separate type definition in a type block.
% In Pascal, types are not considered to be identical simply because they are semantically equivalent.
% Two variables or parameters are only considered to be of the same type if they refer to the
% same type definition.
% As a result, it is not allowed to define new types inside parameter lists, because then it is impossible to
% refer to the same type definition in the procedure headers of the interface and implementation of a unit
% (both procedure headers would define a separate type). Keep in mind that expressions such as
% ``file of byte'' or ``string[50]'' also define a new type.
parser_e_abstract_and_sealed_conflict=03253_E_ABSTRACT and SEALED conflict
% ABSTRACT and SEALED cannot be used together in one declaration
parser_e_sealed_descendant=03254_E_Cannot create a descendant of the sealed class "$1"
% Sealed means that class cannot be derived by another class.
parser_e_sealed_class_cannot_have_abstract_methods=03255_E_SEALED class cannot have an ABSTRACT method
% Sealed means that class cannot be derived. Therefore no one class is able to override an abstract method in a sealed class.
parser_e_only_virtual_methods_final=03256_E_Only virtual methods can be final
% You are declaring a method as final, when it is not declared to be
% virtual.
parser_e_final_can_no_be_overridden=03257_E_Final method cannot be overridden: "$1"
% You are trying to \var{override} a virtual method of a parent class that does
% not exist.
parser_e_multiple_messages=03258_E_Only one message can be used per method.
% It is not possible to associate multiple messages with a single method.
parser_e_invalid_enumerator_identifier=03259_E_Invalid enumerator identifier: "$1"
% Only "MoveNext" and "Current" enumerator identifiers are supported.
parser_e_enumerator_identifier_required=03260_E_Enumerator identifier required
% "MoveNext" or "Current" identifier must follow the \var{enumerator} modifier.
parser_e_enumerator_movenext_is_not_valid=03261_E_Enumerator MoveNext pattern method is not valid. Method must be a function with the Boolean return type and no required arguments.
% "MoveNext" enumerator pattern method must be a function with Boolean return type and no required arguments
parser_e_enumerator_current_is_not_valid=03262_E_Enumerator Current pattern property is not valid. Property must have a getter.
% "Current" enumerator pattern property must have a getter
parser_e_only_one_enumerator_movenext=03263_E_Only one enumerator MoveNext method is allowed per class/object
% Class or Object can have only one enumerator MoveNext declaration.
parser_e_only_one_enumerator_current=03264_E_Only one enumerator Current property is allowed per class/object
% Class or Object can have only one enumerator Current declaration.
parser_e_for_in_loop_cannot_be_used_for_the_type=03265_E_For in loop cannot be used for the type "$1"
% For in loop can be used not for all types. For example it cannot be used for the enumerations with jumps.
parser_e_objc_requires_msgstr=03266_E_Objective-C messages require their Objective-C selector name to be specified using the "message" directive.
% Objective-C messages require their Objective-C name (selector name) to be specified using the \var{message `someName:'} procedure directive.
% While bindings to other languages automatically generate such names based on the identifier you use (by replacing
% all underscores with colons), this is unsafe since nothing prevents an Objective-C method name to contain actual
% colons.
parser_e_objc_no_constructor_destructor=03267_E_Objective-C does not have formal constructors nor destructors. Use the alloc, initXXX and dealloc messages.
% The Objective-C language does not have any constructors or destructors. While there are some messages with a similar
% purpose (such as \var{init} and \var{dealloc}), these cannot be identified using automatic parsers and do not
% guarantee anything like Pascal constructors/destructors (e.g., you have to take care of only calling ``designated''
% inherited ``constructors''). For these reasons, we have opted to follow the standard Objective-C patterns for
% instance creation/destruction.
parser_e_message_string_too_long=03268_E_Message name is too long (max. 255 characters)
% Due to compiler implementation reasons, message names are currently limited to 255 characters.
parser_e_objc_message_name_too_long=03269_E_Objective-C message symbol name for "$1" is too long
% Due to compiler implementation reasons, mangled message names (i.e., the symbol names used in the assembler
% code) are currently limited to 255 characters.
parser_h_no_objc_parent=03270_H_Defining a new Objective-C root class. To derive from another root class (e.g., NSObject), specify it as the parent class.
% If no parent class is specified for an Object Pascal class, then it automatically derives from TObject.
% Objective-C classes however do not automatically derive from NSObject, because one can have multiple
% root classes in Objective-C. For example, in the Cocoa framework both NSObject and NSProxy are root classes.
% Therefore, you have to explicitly define a parent class (such as NSObject) if you want to derive your
% Objective-C class from it.
parser_e_no_objc_published=03271_E_Objective-C classes cannot have published sections.
% In Object Pascal, ``published'' determines whether or not RTTI is generated. Since the Objective-C runtime always needs
% RTTI for everything, this specified does not make sense for Objective-C classes.
parser_f_need_objc=03272_F_This module requires an Objective-C mode switch to be compiled
% This error indicates the use of Objective-C language features without an Objective-C mode switch
% active. Enable one via the -M command line switch, or the {\$modeswitch x} directive.
parser_e_must_use_override=03273_E_Inherited methods can only be overridden in Objective-C and Java, add "override" (inherited method defined in $1)
parser_h_should_use_override=03274_H_Inherited methods can only be overridden in Objective-C and Java, add "override" (inherited method defined in $1).
% It is not possible to \var{reintroduce} methods in Objective-C or Java like in Object Pascal. Methods with the same
% name always map to the same virtual method entry. In order to make this clear in the source code,
% the compiler always requires the \var{override} directive to be specified when implementing overriding
% Objective-C or Java methods in Pascal. If the implementation is external, this rule is relaxed because Objective-C and Java
% do not have any \var{override}-style keyword (since it's the default and only behaviour in these languages),
% which makes it hard for automated header conversion tools to include it everywhere.
% The type in which the inherited method is defined is explicitly mentioned, because this may either
% be an objcclass or an objccategory in case of Objective-C.
parser_e_objc_message_name_changed=03275_E_Message name "$1" in inherited class is different from message name "$2" in current class.
% An overriding Objective-C method cannot have a different message name than an inherited method. The reason
% is that these message names uniquely define the message to the Objective-C runtime, which means that
% giving them a different message name breaks the ``override'' semantics.
parser_e_unique_unsupported=03276_E_It is not yet possible to make unique copies of Objective-C or Java types
% Duplicating an Objective-C or Java type using \var{type x = type y;} is not yet supported. You may be able to
% obtain the desired effect using \var{type x = objcclass(y) end;} resp.{} \var{type x = class(y) end;} instead.
parser_e_no_category_as_types=03277_E_Objective-C categories and Object Pascal class helpers cannot be used as types
% It is not possible to declare a variable as an instance of an Objective-C
% category or an Object Pascal class helper. A category/class helper adds
% methods to the scope of an existing class, but does not define a type by
% itself. An exception of this rule is when inheriting an Object Pascal class
% helper from another class helper.
parser_e_no_category_override=03278_E_Categories do not override, but replace methods. Use "reintroduce" instead.
parser_e_must_use_reintroduce_objc=03279_E_Replaced methods can only be reintroduced in Objective-C, add "reintroduce" (replaced method defined in $1).
parser_h_should_use_reintroduce_objc=03280_H_Replaced methods can only be reintroduced in Objective-C, add "reintroduce" (replaced method defined in $1).
% A category replaces an existing method in an Objective-C class, rather than that it overrides it.
% Calling an inherited method from an category method will call that method in
% the extended class' parent, not in the extended class itself. The
% replaced method in the original class is basically lost, and can no longer be
% called or referred to. This behaviour corresponds somewhat more closely to
% \var{reintroduce} than to \var{override} (although in case of \var{reintroduce}
% in Object Pascal, hidden methods are still reachable via inherited).
% The type in which the inherited method is defined is explicitly mentioned, because this may either
% be an objcclass or an objccategory.
parser_e_implements_getter_not_default_cc=03281_E_Getter for implements interface must use the target's default calling convention.
% Interface getters are called via a helper in the run time library, and hence
% have to use the default calling convention for the target (\var{register} on
% i386 and x86\_64, \var{stdcall} on other architectures).
parser_e_no_refcounted_typed_file=03282_E_Typed files cannot contain reference-counted types.
% The data in a typed file cannot be of a reference counted type (such as
% \var{ansistring} or a record containing a field that is reference counted).
parser_e_operator_not_overloaded_2=03283_E_Operator is not overloaded: $2 "$1"
% You are trying to use an overloaded operator when it is not overloaded for
% this type.
parser_e_operator_not_overloaded_3=03284_E_Operator is not overloaded: "$1" $2 "$3"
% You are trying to use an overloaded operator when it is not overloaded for
% this type.
parser_e_more_array_elements_expected=03285_E_Expected another $1 array elements
% When declaring a typed constant array, you provided to few elements to initialize the array
parser_e_string_const_too_long=03286_E_String constant too long while ansistrings are disabled
% Only when a piece of code is compiled with ansistrings enabled (\var{\{\$H+\}}), string constants
% longer than 255 characters are allowed.
parser_e_invalid_univ_para=03287_E_Type cannot be used as univ parameter because its size is unknown at compile time: "$1"
% \var{univ} parameters are compatible with all values of the same size, but this
% cannot be checked in case a parameter's size is unknown at compile time.
parser_e_only_one_class_constructor_allowed=03288_E_Only one class constructor can be declared in class: "$1"
% You are trying to declare more than one class constructor but only one class constructor can be declared.
parser_e_only_one_class_destructor_allowed=03289_E_Only one class destructor can be declared in class: "$1"
% You are trying to declare more than one class destructor but only one class destructor can be declared.
parser_e_no_paras_for_class_constructor=03290_E_Class constructors cannot have parameters
% You are declaring a class constructor with a parameter list. Class constructor methods
% cannot have parameters.
parser_e_no_paras_for_class_destructor=03291_E_Class destructors cannot have parameters
% You are declaring a class destructor with a parameter list. Class destructor methods
% cannot have parameters.
parser_f_modeswitch_objc_required=03292_F_This construct requires the \{\$modeswitch objectivec1\} mode switch to be active
% Objective-Pascal constructs are not supported when \{\$modeswitch ObjectiveC1\}
% is not active.
parser_e_widestring_to_ansi_compile_time=03293_E_Unicodechar/string constants cannot be converted to ansi/shortstring at compile-time
% It is not possible to use unicodechar and unicodestring constants in
% constant expressions that have to be converted into an ansistring or shortstring
% at compile time, for example inside typed constants. The reason is that the
% compiler cannot know what the actual ansi encoding will be at run time.
parser_e_objc_enumerator_2_0=03294_E_For-in Objective-Pascal loops require \{\$modeswitch ObjectiveC2\} to be active
% Objective-C ``fast enumeration'' support was added in Objective-C 2.0, and
% hence the appropriate modeswitch has to be activated to expose this feature.
% Note that Objective-C 2.0 programs require Mac OS X 10.5 or later.
parser_e_objc_missing_enumeration_defs=03295_E_The compiler cannot find the NSFastEnumerationProtocol or NSFastEnumerationState type in the CocoaAll unit
% Objective-C for-in loops (fast enumeration) require that the compiler can
% find a unit called CocoaAll that contains definitions for the
% NSFastEnumerationProtocol and NSFastEnumerationState types. If you get this
% error, most likely the compiler is finding and loading an alternate CocoaAll
% unit.
parser_e_no_procvarnested_const=03296_E_Typed constants of the type 'procedure is nested' can only be initialized with NIL and global procedures/functions
% A nested procedural variable consists of two components: the address of the
% procedure/function to call (which is always known at compile time), and also
% a parent frame pointer (which is never known at compile time) in case the
% procedural variable contains a reference to a nested procedure/function.
% Therefore such typed constants can only be initialized with global
% functions/procedures since these do not require a parent frame pointer.
parser_f_no_generic_inside_generic=03297_F_Declaration of generic class inside another generic class is not allowed
% At the moment, scanner supports recording of only one token buffer at the time
% (guarded by internal error 200511173 in tscannerfile.startrecordtokens).
% Since generics are implemented by recording tokens, it is not possible to
% have declaration of generic class inside another generic class.
parser_e_forward_intf_declaration_must_be_resolved=03298_E_Forward declaration "$1" must be resolved before a class can conform to or implement it
% An Objective-C protocol or Java Interface must be fully defined before classes can conform to it.
% This error occurs in the following situation (example for Objective-C, but the same goes for Java interfaces):
% \begin{verbatim}
% Type MyProtocol = objcprotoocl;
% ChildClass = Class(NSObject,MyProtocol)
% ...
% end;
% \end{verbatim}
% where \var{MyProtocol} is declared but not defined.
parser_e_no_record_published=03299_E_Record types cannot have published sections
% Published sections can be used only inside classes.
parser_e_no_destructor_in_records=03300_E_Destructors are not allowed in records or helpers
% Destructor declarations are not allowed in records or helpers.
parser_e_class_methods_only_static_in_records=03301_E_Class methods must be static in records
% Class methods declarations are not allowed in records without static modifier.
% Records have no inheritance and therefore non static class methods have no sense for them.
parser_e_no_parameterless_constructor_in_records=03302_E_Parameterless constructors are not allowed in records or record/type helpers
% Constructor declarations with no arguments are not allowed in records or record/type helpers.
parser_e_at_least_one_argument_must_be_of_type=03303_E_Either the result or at least one parameter must be of type "$1"
% It is required that either the result of the routine or at least one of its parameters be of the specified type.
% For example class operators either take an instance of the structured type in which they are defined, or they return one.
parser_e_cant_use_type_parameters_here=03304_E_Type parameters may require initialization/finalization - cannot be used in variant records
% Type parameters may be specialized with types which (e.g. \var{ansistring}) need initialization/finalization
% code which is implicitly generated by the compiler.
parser_e_externals_no_section=03305_E_Variables being declared as external cannot be in a custom section
% A section directive is not valid for variables being declared as external.
parser_e_section_no_locals=03306_E_Non-static and non-global variables cannot have a section directive
% A variable placed in a custom section is always statically allocated so it must be either a static or global variable.
parser_e_not_allowed_in_helper=03307_E_"$1" is not allowed in helper types
% Some directives and specifiers like "virtual", "dynamic", "override" are not
% allowed inside helper types in mode ObjFPC (they are ignored in mode Delphi),
% because they have no meaning within helpers. Also "abstract" isn't allowed in
% either mode.
parser_e_no_class_constructor_in_helpers=03308_E_Class constructors are not allowed in helpers
% Class constructor declarations are not allowed in helpers.
parser_e_inherited_not_in_record=03309_E_The use of "inherited" is not allowed in a record
% As records don't support inheritance the use of "inherited" is prohibited for
% these as well as for record helpers (in mode "Delphi" only).
parser_e_no_types_in_local_anonymous_records=03310_E_Type declarations are not allowed in local or anonymous records
% Records with types must be defined globally. Types cannot be defined inside records which are defined in a
% procedure or function or in anonymous records.
parser_e_duplicate_implements_clause=03311_E_Duplicate implements clause for interface "$1"
% A class may delegate an interface using the "implements" clause only to a single property. Delegating it multiple times
% is a error.
parser_e_mapping_no_implements=03312_E_Interface "$1" cannot be delegated by "$2", it already has method resolutions
% Method resolution clause maps a method of an interface to a method of the current class. Therefore the current class
% has to implement the interface directly. Delegation is not possible.
parser_e_implements_no_mapping=03313_E_Interface "$1" cannot have method resolutions, "$2" already delegates it
% Method resolution is only possible for interfaces that are implemented directly, not by delegation.
parser_e_invalid_codepage=03314_E_Invalid codepage
% When declaring a string with a given codepage, the range of valid codepages values is limited
% to 0 to 65535.
parser_e_final_only_const_var=03315_E_Only fields (var-sections) and constants can be final in object types
% A final (class) field must be assigned a single value in the (class) constructor, and cannot
% be overwritten afterwards. A final (typed) constant is read-only.
parser_e_final_only_external=03316_E_Final fields are currently only supported for external classes
% Support for final fields in non-external classes requires a full data flow
% analysis implementation in FPC, which it currently still lacks.
parser_e_no_typed_const=03317_E_Typed constants are not allowed here, only formal constants are
% Java interfaces define a namespace in which formal constant can be defined,
% but since they define no storage it is not possible to define typed constants
% in them (those are more or less the same as initialised class fields).
parser_e_java_no_inherited_constructor=03318_E_Constructors are not automatically inherited in the JVM; explicitly add a constructor that calls the inherited one if you need it
% Java does not automatically add inherited constructors to child classes, so that they can be hidden.
% For compatibility with external Java code, FPC does the same. If you require access to the same
% constructors in a child class, define them in the child class and call the inherited one from
% there.
parser_d_internal_parser_string=03319_D_Parsing internally generated code: $1
% The compiler sometimes internally constructs Pascal code that is subsequently
% injected into the program. These messages display such code, in order to help
% with debugging errors in them.
parser_e_feature_unsupported_for_vm=03320_E_This language feature is not supported on managed VM targets
% Certain language features are not supported on targets that are managed virtual machines.
parser_e_jvm_invalid_virtual_constructor_call=03321_E_Calling a virtual constructor for the current instance inside another constructor is not possible on the JVM target
% The JVM does not natively support virtual constructor. Unforunately, we are not aware of a way to
% emulate them in a way that makes it possible to support calling virtual constructors
% for the current instance inside another constructor.
parser_e_method_lower_visibility=03322_E_Overriding method "$1" cannot have a lower visibility ($2) than in parent class $3 ($4)
% The JVM does not allow lowering the visibility of an overriding method.
parser_e_nostackframe_without_assembler=03323_E_Procedure/Function declared with call option NOSTACKFRAME but without ASSEMBLER
% nostackframe call modifier is supposed to be used in conjunction with assembler.
parser_e_nostackframe_with_locals=03324_E_Procedure/Function declared with call option NOSTACKFRAME but local stack size is $1
% nostackframe call modifier used without assembler modifier
% might still generate local stack needs.
parser_e_cannot_generate_property_getter_setter=03325_E_Cannot generate property getter/setter $1 because its name clashes with existing identifier $2
% Automatically generated getters/setters cannot have the same name as existing
% identifiers, because this may change the behaviour of existing code.
parser_w_overriding_property_getter_setter=03326_W_Automatically generated property getter/setter $1 overrides the same-named getter/setter in class $2
% Automatically generated property getters/setters on the JVM platform are virtual methods, because
% the JVM does not support non-virtual methods that can be changed in child classes. This means
% that if a child class changes an inherited property definition, the behaviour of that property
% can change compared to native targets since even if a variable is declared as the parent type,
% by calling the virtual method the getter from the child will be used. This is different from
% the behaviour on native targets or when not activating automatically generated setters/getters,
% because in that case only the declared type of a variable influences the property behaviour.
parser_w_case_difference_auto_property_getter_setter_prefix=03327_W_Case mismatch between declared property getter/setter $1 and automatically constructed name $2, not changing declared name
% If a property's specified getter/setter already corresponded to the naming convention specified
% by the automatic getter/setter generation setting except in terms of upper/lowercase, the
% compiler will print a warning because it cannot necessarily change that other declaration itself
% not can it add one using the correct case (it could conflict with the original declaration).
% Manually correct the case of the getter/setter to conform to the desired coding rules.
% \var{TChild} overrides
parser_e_no_consts_in_local_anonymous_records=03328_E_Constants declarations are not allowed in local or anonymous records
% Records with constants must be defined globally. Constants cannot be defined inside records which are defined in a
% procedure or function or in anonymous records.
parser_e_no_methods_in_local_anonymous_records=03329_E_Method declarations are not allowed in local or anonymous records
% Records with methods must be defined globally. Methods cannot be defined inside records which are defined in a
% procedure or function or in anonymous records.
parser_e_no_properties_in_local_anonymous_records=03330_E_Property declarations are not allowed in local or anonymous records
% Records with properties must be defined globally. Properties cannot be defined inside records which are defined in a
% procedure or function or in anonymous records.
parser_e_no_class_in_local_anonymous_records=03331_E_Class member declarations are not allowed in local or anonymous records
% Records with class members must be defined globally. Class members cannot be defined inside records which are defined in a
% procedure or function or in anonymous records.
parser_e_not_allowed_in_record=03332_E_Visibility section "$1" not allowed in records
% The visibility sections \var(protected) and \var(strict protected) are only
% useful together with inheritance. Since records do not support that they are
% forbidden.
parser_e_dir_not_allowed=03333_E_Directive "$1" not allowed here
% This directive is not allowed in the given context. E.g. "static"
% is not allowed for instance methods or class operators.
parser_e_no_assembler_in_generic=03334_E_Assembler blocks not allowed inside generics
% The use of assembler blocks/routines is not allowed inside generics.
parser_e_property_only_sgr=03335_E_Properties can be only static, global or inside structured types
% Properties cannot be declared local, only global, using the static
% directive or inside structured types.
parser_e_overloaded_have_same_mangled_name=03336_E_Overloaded routines have the same mangled name
% Some platforms, such as the JVM platform, encode the parameters in the routine name in
% a prescribed way, and this encoding may map different Pascal types to the same encoded
% (a.k.a.\ ``mangled'') name. This error can only be solved by removing or changing the
% conflicting definitions' parameter declarations or routine names.
parser_e_default_value_val_const=03337_E_Default values can only be specified for value, const and constref parameters
% A default parameter value allows you to not specify a value for this parameter
% when calling the routine, and the compiler will instead pass the specified
% default (constant) value. As a result, default values can only be specified
% for parameters that can accept constant values.
parser_w_ptr_type_ignored=03338_W_Pointer type "$1" ignored
% The specified pointer type modifier is ignored, because it is not supported on
% the current platform. This happens, for example, when a far pointer is
% declared on a non-x86 platform.
parser_e_global_generic_references_static=03339_E_Global Generic template references static symtable
% A generic declared in the interface section of a unit must not reference symbols that belong
% solely to the implementation section of that unit.
parser_u_already_compiled=03340_UL_Unit $1 has been already compiled meanwhile.
% This tells you that the recursive reading of the uses clauses triggered already
% a compilation of the current unit, so the current compilation can be aborted.
%
%
%
% \end{description}
%
# Type Checking
#
# 04123 is the last used one
#
% \section{Type checking errors}
% This section lists all errors that can occur when type checking is
% performed.
% \begin{description}
type_e_mismatch=04000_E_Type non valable
% This can happen in many cases:
% \begin{itemize}
% \item The variable you're assigning to is of a different type than the
% expression in the assignment.
% \item You are calling a function or procedure with parameters that are
% incompatible with the parameters in the function or procedure definition.
% \end{itemize}
type_e_incompatible_types=04001_E_Types incompatibles: $1 spécifié mais $2 attendu
% There is no conversion possible between the two types
% Another possiblity is that they are declared in different
% declarations:
% \begin{verbatim}
% Var
% A1 : Array[1..10] Of Integer;
% A2 : Array[1..10] Of Integer;
%
% Begin
% A1:=A2; { This statement gives also this error, it
% is due the strict type checking of pascal }
% End.
% \end{verbatim}
type_e_not_equal_types=04002_E_Incompatibilité de types entre $1 et $2
% The types are not equal
type_e_type_id_expected=04003_E_Identificateur de type attendu
% The identifier is not a type, or you forgot to supply a type identifier.
type_e_variable_id_expected=04004_E_Identificateur de variable attendu
% This happens when you pass a constant to a routine (such as \var{Inc} var or \var{Dec})
% when it expects a variable. You can only pass variables as arguments to these functions.
type_e_integer_expr_expected=04005_E_Expression entière attendue, "$1" spécifié
% The compiler expects an expression of type integer, but gets a different
% type.
type_e_boolean_expr_expected=04006_E_Expression booléenne attendue mais "$1" spécifié
% The expression must be a boolean type, it should be return true or
% false.
type_e_ordinal_expr_expected=04007_E_Expression ordinale attendue
% The expression must be of ordinal type, i.e., maximum a \var{Longint}.
% This happens, for instance, when you specify a second argument
% to \var{Inc} or \var{Dec} that doesn't evaluate to an ordinal value.
type_e_pointer_type_expected=04008_E_Type pointeur attendu, "$1" spécifié
% The variable or expression isn't of the type \var{pointer}. This
% happens when you pass a variable that isn't a pointer to \var{New}
% or \var{Dispose}.
type_e_class_type_expected=04009_E_Type classe attendu mais "$1" spécifié
% The variable of expression isn't of the type \var{class}. This happens
% typically when
% \begin{enumerate}
% \item The parent class in a class declaration isn't a class.
% \item An exception handler (\var{On}) contains a type identifier that
% isn't a class.
% \end{enumerate}
type_e_cant_eval_constant_expr=04011_E_Impossible d'évaluer l'expression constante
% This error can occur when the bounds of an array you declared does
% not evaluate to ordinal constants
type_e_set_element_are_not_comp=04012_E_Éléments de l'ensemble incompatibles
% You are trying to make an operation on two sets, when the set element types
% are not the same. The base type of a set must be the same when taking the
% union
type_e_set_operation_unknown=04013_E_Opération non implémentée pour des ensembles
% several binary operations are not defined for sets
% like div mod ** (also >= <= for now)
type_w_convert_real_2_comp=04014_W_Conversion automatique d'un réel vers COMP qui est un type entier
% An implicit type conversion from a real type to a \var{comp} is
% encountered. Since \var{comp} is a 64 bit integer type, this may indicate
% an error.
type_h_use_div_for_int=04015_H_Utilisez DIV pour obtenir un résultat entier
% When hints are on, then an integer division with the '/' operator will
% procuce this message, because the result will then be of type real
type_e_strict_var_string_violation=04016_E_Types de chaînes incompatibles à cause du mode $V+
% When compiling in \var{\{\$V+\}} mode, the string you pass as a parameter
% should be of the exact same type as the declared parameter of the procedure.
type_e_succ_and_pred_enums_with_assign_not_possible=04017_E_Succ ou Pred impossible pour des énumérations contenant des affectations
% When you declared an enumeration type which has assignments in it, as in C,
% like in the following:
% \begin{verbatim}
% Tenum = (a,b,e:=5);
% \end{verbatim}
% you cannot use the \var{Succ} or \var{Pred} functions on them.
type_e_cant_read_write_type=04018_E_Impossible de lire ou d'écrire des variables de ce type
% You are trying to \var{read} or \var{write} a variable from or to a
% file of type text, which doesn't support that. Only integer types,
% reals, pchars and strings can be read from/written to a text file.
% Booleans can only be written to text files.
type_e_no_readln_writeln_for_typed_file=04019_E_Impossible d'utiliser ReadLn ou WriteLn sur un ficher typé
% \var{readln} and \var{writeln} are only allowed for text files.
type_e_no_read_write_for_untyped_file=04020_E_Impossible d'utiliser Read ou Write sur un fichier non typé
% \var{read} and \var{write} are only allowed for text or typed files.
type_e_typeconflict_in_set=04021_E_Conflit de type dans les éléments de l'ensemble
% There is at least one set element which is of the wrong type, i.e. not of
% the set type.
type_w_maybe_wrong_hi_lo=04022_W_Lo/Hi(Longint/DWord) retourne le mot ou le double mot de poids fort ou de poids faible
% \fpc supports an overloaded version of \var{lo/hi} for \var{longint/dword/int64/qword}
% which returns the lower/upper word/dword of the argument. TP always uses
% a 16 bit \var{lo/hi} which returns always bits 0..7 for \var{lo} and the
% bits 8..15 for \var{hi}. If you want the TP behavior you have
% to type cast the argument to \var{word/integer}
type_e_integer_or_real_expr_expected=04023_E_Expression entière ou réelle attendue
% The first argument to \var{str} must a real or integer type.
type_e_wrong_type_in_array_constructor=04024_E_Mauvais type "$1" dans le constructeur
% You are trying to use a type in an array constructor which is not
% allowed.
type_e_wrong_parameter_type=04025_E_Type incompatible pour l'argument no. $1: $2 spécifié au lieu de $3
% You are trying to pass an invalid type for the specified parameter.
type_e_no_method_and_procedure_not_compatible=04026_E_Méthodes (variable) et procédures (variable) sont incompatibles
% You can't assign a method to a procedure variable or a procedure to a
% method pointer.
type_e_wrong_math_argument=04027_E_Constante invalide passée à une fonction mathématique interne
% The constant argument passed to a ln or sqrt function is out of
% the definition range of these functions.
type_e_no_addr_of_constant=04028_E_Impossible d'obtenir l'adresse des constantes
% It is not possible to get the address of a constant, because they
% aren't stored in memory, you can try making it a typed constant.
type_e_argument_cant_be_assigned=04029_E_Cet argument ne peut pas être passé par référence
% Only expressions which can be on the left side of an
% assignment can be passed as call by reference argument
% Remark: Properties can be only
% used on the left side of an assignment, but they cannot be used as arguments
type_e_cannot_local_proc_to_procvar=04030_E_Impossible d'assigner une fonction ou une procédure locale à une variable de type procédure
% It's not allowed to assign a local procedure/function to a
% procedure variable, because the calling of local procedure/function is
% different. You can only assign local procedure/function to a void pointer.
type_e_no_assign_to_addr=04031_E_Impossible d'affecter des valeurs à une adresse
% It is not allowed to assign a value to an address of a variable,constant,
% procedure or function. You can try compiling with -So if the identifier
% is a procedure variable.
type_e_no_assign_to_const=04032_E_Impossible d'affecter des valeurs à une constante
% It's not allowed to assign a value to a variable which is declared
% as a const. This is normally a parameter declared as const, to allow
% changing the value make the parameter as a value parameter or a var.
type_e_array_required=04033_E_Type de tableau requis
% If you are accessing a variable using an index '[<x>]' then
% the type must be an array. In FPC mode also a pointer is allowed.
type_e_interface_type_expected=04034_E_Type interface attendu, "$1" spécifié
% The compiler expected to encounter an interface type name, but got something else.
% The following code would provoke this error:
% \begin{verbatim}
% Type
% TMyStream = Class(TStream,Integer)
% \end{verbatim}
type_h_mixed_signed_unsigned=04035_H_Mixing signed expressions and longwords gives a 64bit result
% If you divide (or calculate the modulus of) a signed expression by a longword (or vice versa),
% or if you have overflow and/or range checking turned on and use an arithmetic
% expression (+, -, *, div, mod) in which both signed numbers and longwords appear,
% then everything has to be evaluated in 64-bit arithmetic which is slower than normal
% 32-bit arithmetic. You can avoid this by typecasting one operand so it
% matches the result type of the other one.
type_w_mixed_signed_unsigned2=04036_W_Le mélange d'expressions signées et de cardinaux ici peut provoquer une erreur de dépassement d'intervalle
% If you use a binary operator (and, or, xor) and one of
% the operands is a longword while the other one is a signed expression, then,
% if range checking is turned on, you may get a range check error because in
% such a case both operands are converted to longword before the operation is
% carried out. You can avoid this by typecasting one operand so it
% matches the result type of the other one.
type_e_typecast_wrong_size_for_assignment=04037_E_Transtypage de types de tailles différentes ($1 -> $2) dans l'affectation
% Type casting to a type with a different size is not allowed when the variable is
% used for assigning.
type_e_array_index_enums_with_assign_not_possible=04038_E_Les énumérations contenant des affectations ne peuvent pas être utilisées comme index de tableau
% When you declared an enumeration type which has assignments in it, as in C,
% like in the following:
% \begin{verbatim}
% Tenum = (a,b,e:=5);
% \end{verbatim}
% you cannot use it as index of an array.
type_e_classes_not_related=04039_E_Les types de classe ou d'objet "$1" et "$2" ne sont pas compatibles
% There is a typecast from one class or object to another while the class/object
% are not related. This will probably lead to errors
type_w_classes_not_related=04040_W_Classes "$1" et "$2" incompatibles
% There is a typecast from one class or object to another while the class/object
% are not related. This will probably lead to errors
type_e_class_or_interface_type_expected=04041_E_Classe ou interface attendue mais "$1" spécifié
% The compiler expected a class or interface name, but got another type or identifier.
type_e_type_is_not_completly_defined=04042_E_Le type "$1" n'est pas complètement défini
% This error occurs when a type is not complete: i.e. a pointer type which points to
% an undefined type.
type_w_string_too_long=04043_W_La chaîne contient plus de caractères que ne peut en contenir une chaîne courte
% The size of the constant string, which is assigned to a shortstring,
% is longer than the maximum size of the shortstring
type_w_comparison_always_false=04044_W_Comparison might be always false due to range of constant and expression
% There is a comparison between a constant and an expression where the constant is out of the
% valid range of values of the expression. Because of type promotion, the statement will always evaluate to
% false. Explicitly typecast the constant or the expression to the correct range to avoid this warning
% if you think the code is correct.
type_w_comparison_always_true=04045_W_Comparison might be always true due to range of constant and expression
% There is a comparison between a constant and an expression where the constant is out of the
% valid range of values of the expression. Because of type promotion, the statement will always evaluate to
% true. Explicitly typecast the constant or the expression to the correct range to avoid this warning
% if you think the code is correct.
type_w_instance_with_abstract=04046_W_Construction d´une classe "$1" avec des méthodes abstraites
% An instance of a class is created which contains non-implemented abstract
% methods. This will probably lead to a runtime error 211 in the code if that
% routine is ever called. All abstract methods should be overridden.
type_h_in_range_check=04047_H_L´opérande à gauche de l´opérateur IN doit avoir la longueur d´un octet (8 bits)
% The left operand of the \var{in} operator is not an ordinal or enumeration which fits
% within 8-bits, this may lead to range check errors. The \var{in} operator
% currently only supports a left operand which fits within a byte. In the case of
% enumerations, the size of an element of an enumeration can be controlled with
% the \var{\{\$PACKENUM\}} or \var{\{\$Zn\}} switches.
type_w_smaller_possible_range_check=04048_W_Divergence de taille des types, risque de perte de données ou d'erreur de dépassement d'intervalle
% There is an assignment to a smaller type than the source type. This means that
% this may cause a range-check error, or may lead to possible loss of data.
type_h_smaller_possible_range_check=04049_H_Taille des types non concordante, possibilité de perte de données ou d´erreur de dépassement d´intervalle
% There is an assignment to a smaller type than the source type. This means that
% this may cause a range-check error, or may lead to possible loss of data.
type_e_cant_take_address_of_abstract_method=04050_E_L'adresse d'une méthode abstraite ne peut pas être utilisée
% An abstract method has no body, so the address of an abstract method can't be taken.
type_e_assignment_not_allowed=04051_E_Assignments to formal parameters and open arrays are not possible
% You are trying to assign a value to a formal (untyped var, const or out)
% parameter, or to an open array.
type_e_constant_expr_expected=04052_E_Expression constante attendue
% The compiler expects an constant expression, but gets a variable expression.
type_e_operator_not_supported_for_types=04053_E_L'opération "$1" n'est pas supportée pour les types "$2" et "$3"
% The operation is not allowed for the supplied types
type_e_illegal_type_conversion=04054_E_Conversion de types illégale: de "$1" vers "$2"
% When doing a type-cast, you must take care that the sizes of the variable and
% the destination type are the same.
type_h_pointer_to_longint_conv_not_portable=04055_H_La conversion entre types scalaires et pointeurs n´est pas portable
% If you typecast a pointer to a longint (or vice-versa), this code will not compile
% on a machine using 64-bit for pointer storage.
type_w_pointer_to_longint_conv_not_portable=04056_W_La conversion entre cardinaux et pointeurs n'est pas portable
% If you typecast a pointer to a ordinal type of a different size (or vice-versa), this can
% cause problems. This is a warning to help finding the 32bit specific code where cardinal/longint is used
% to typecast pointers to ordinals. A solution is to use the ptrint/ptruint types instead.
type_e_cant_choose_overload_function=04057_E_Impossible de déterminer quelle fonction overload appeler
% You're calling overloaded functions with a parameter that doesn't correspond
% to any of the declared function parameter lists. e.g. when you have declared
% a function with parameters \var{word} and \var{longint}, and then you call
% it with a parameter which is of type \var{integer}.
type_e_illegal_count_var=04058_E_Variable de boucle FOR invalide
% The type of a \var{for} loop variable must be an ordinal type.
% Loop variables cannot be reals or strings.
type_w_double_c_varargs=04059_W_Conversion d'une valeur réelle constante en valeur double pour un paramètre variable C, ajoutez un transtypage explicite pour éviter ceci
% In C, constant real values are double by default. For this reason, if you
% pass a constant real value to a variable argument part of a C function, FPC
% by default converts this constant to double as well. If you want to prevent
% this from happening, add an explicit typecast around the constant.
type_e_class_or_cominterface_type_expected=04060_E_Classe ou interface COM attendue mais "$1" spécifié
% Some operators like the AS operator are only appliable to classes or COM interfaces.
% \end{description}
#
# Symtable
#
# 05060 is the last used one
#
% \section{Symbol handling}
% This section lists all the messages that concern the handling of symbols.
% This means all things that have to do with procedure and variable names.
% \begin{description}
type_e_no_const_packed_array=04061_E_Constant packed arrays are not yet supported
% You cannot declare a (bit)packed array as a typed constant.
type_e_got_expected_packed_array=04062_E_Incompatible type for arg no. $1: Got "$2" expected "(Bit)Packed Array"
% The compiler expects a (bit)packed array as the specified parameter.
type_e_got_expected_unpacked_array=04063_E_Incompatible type for arg no. $1: Got "$2" expected "(not packed) Array"
% The compiler expects a regular (i.e., not packed) array as the specified parameter.
type_e_no_packed_inittable=04064_E_Elements of packed arrays cannot be of a type which need to be initialised
% Support for packed arrays of types that need initialization
% (such as ansistrings, or records which contain ansistrings) is not yet implemented.
type_e_no_const_packed_record=04065_E_Constant packed records and objects are not yet supported
% You cannot declare a (bit)packed array as a typed constant at this time.
type_w_untyped_arithmetic_unportable=04066_W_Arithmetic "$1" on untyped pointer is unportable to {$T+}, suggest typecast
% Addition/subtraction from an untyped pointer may work differently in \var{\{\$T+\}}.
% Use a typecast to a typed pointer.
type_e_cant_take_address_of_local_subroutine=04076_E_Can't take address of a subroutine marked as local
% The address of a subroutine marked as local cannot be taken.
type_e_cant_export_local=04077_E_Can't export subroutine marked as local from a unit
% A subroutine marked as local cannot be exported from a unit.
type_e_not_automatable=04078_E_Type is not automatable: "$1"
% Only byte, integer, longint, smallint, currency, single, double, ansistring,
% widestring, tdatetime, variant, olevariant, wordbool and all interfaces are automatable.
type_h_convert_add_operands_to_prevent_overflow=04079_H_Converting the operands to "$1" before doing the add could prevent overflow errors.
% Adding two types can cause overflow errors. Since you are converting the result to a larger type, you
% could prevent such errors by converting the operands to this type before doing the addition.
type_h_convert_sub_operands_to_prevent_overflow=04080_H_Converting the operands to "$1" before doing the subtract could prevent overflow errors.
% Subtracting two types can cause overflow errors. Since you are converting the result to a larger type, you
% could prevent such errors by converting the operands to this type before doing the subtraction.
type_h_convert_mul_operands_to_prevent_overflow=04081_H_Converting the operands to "$1" before doing the multiply could prevent overflow errors.
% Multiplying two types can cause overflow errors. Since you are converting the result to a larger type, you
% could prevent such errors by converting the operands to this type before doing the multiplication.
type_w_pointer_to_signed=04082_W_Converting pointers to signed integers may result in wrong comparison results and range errors, use an unsigned type instead.
% The virtual address space on 32-bit machines runs from \$00000000 to \$ffffffff.
% Many operating systems allow you to allocate memory above \$80000000.
% For example both \windows and \linux allow pointers in the range \$0000000 to \$bfffffff.
% If you convert pointers to signed types, this can cause overflow and range check errors,
% but also \$80000000 < \$7fffffff. This can cause random errors in code like "if p>q".
type_e_interface_has_no_guid=04083_E_Interface type $1 has no valid GUID
% When applying the as-operator to an interface or class, the desired interface (i.e. the right operand of the
% as-operator) must have a valid GUID.
type_e_invalid_objc_selector_name=04084_E_Invalid selector name "$1"
% An Objective-C selector cannot be empty, must be a valid identifier or a single colon,
% and if it contains at least one colon it must also end in one.
type_e_expected_objc_method_but_got=04085_E_Expected Objective-C method, but got $1
% A selector can only be created for Objective-C methods, not for any other kind
% of procedure/function/method.
type_e_expected_objc_method=04086_E_Expected Objective-C method or constant method name
% A selector can only be created for Objective-C methods, either by specifying
% the name using a string constant, or by using an Objective-C method identifier
% that is visible in the current scope.
type_e_no_type_info=04087_E_No type info available for this type
% Type information is not generated for some types, such as enumerations with gaps
% in their value range (this includes enumerations whose lower bound is different
% from zero).
type_e_ordinal_or_string_expr_expected=04088_E_Ordinal or string expression expected
% The expression must be an ordinal or string type.
type_e_string_expr_expected=04089_E_String expression expected
% The expression must be a string type.
type_w_zero_to_nil=04090_W_Converting 0 to NIL
% Use NIL rather than 0 when initialising a pointer.
type_e_protocol_type_expected=04091_E_Objective-C protocol type expected, but got "$1"
% The compiler expected a protocol type name, but found something else.
type_e_objc_type_unsupported=04092_E_The type "$1" is not supported for interaction with the Objective-C and the blocks runtime.
% Objective-C and Blocks make extensive use of run time type information (RTTI). This format
% is defined by the maintainers of the run time and can therefore not be adapted
% to all possible Object Pascal types. In particular, types that depend on
% reference counting by the compiler (such as ansistrings and certain kinds of
% interfaces) cannot be used as fields of Objective-C classes, cannot be
% directly passed to Objective-C methods or Blocks, and cannot be encoded using \var{objc\_encode}.
type_e_class_or_objcclass_type_expected=04093_E_Class or objcclass type expected, but got "$1"
% It is only possible to create class reference types of \var{class} and \var{objcclass}
type_e_objcclass_type_expected=04094_E_Objcclass type expected
% The compiler expected an \var{objcclass} type
type_w_procvar_univ_conflicting_para=04095_W_Coerced univ parameter type in procedural variable may cause crash or memory corruption: $1 to $2
% \var{univ} parameters are implicitly compatible with all types of the same size,
% also in procedural variable definitions. That means that the following code is
% legal, because \var{single} and \var{longint} have the same size:
% \begin{verbatim}
% {$mode macpas}
% Type
% TIntProc = procedure (l: univ longint);
%
% procedure test(s: single);
% begin
% writeln(s);
% end;
%
% var
% p: TIntProc;
% begin
% p:=test;
% p(4);
% end.
% \end{verbatim}
% This code may however crash on platforms that pass integers in registers and
% floating point values on the stack, because then the stack will be unbalanced.
% Note that this warning will not flag all potentially dangerous situations.
% when \var{test} returns.
type_e_generics_cannot_reference_itself=04096_E_Type parameters of specializations of generics cannot reference the currently specialized type
% Recursive specializations of generics like \var{Type MyType = specialize MyGeneric<MyType>;} are not possible.
type_e_type_parameters_are_not_allowed_here=04097_E_Type parameters are not allowed on non-generic class/record/object procedure or function
% Type parameters are only allowed for methods of generic classes, records or objects
type_e_generic_declaration_does_not_match=04098_E_Generic declaration of "$1" differs from previous declaration
% Generic declaration does not match the previous declaration
type_e_helper_type_expected=04099_E_Helper type expected
% The compiler expected a \var{class helper} type.
type_e_record_type_expected=04100_E_Record type expected
% The compiler expected a \var{record} type.
type_e_class_helper_must_extend_subclass=04101_E_Derived class helper must extend a subclass of "$1" or the class itself
% If a class helper inherits from another class helper the extended class must
% extend either the same class as the parent class helper or a subclass of it
type_e_record_helper_must_extend_same_record=04102_E_Derived record or type helper must extend "$1"
% If a record helper inherits from another record helper it must extend the same
% record that the parent record helper extended.
type_e_procedures_return_no_value=04103_E_Invalid assignment, procedures return no value
% This error occurs when one tries to assign the result of a procedure or destructor call.
% A procedure or destructor returns no value so this is not
% possible.
type_w_implicit_string_cast=04104_W_Implicit string type conversion from "$1" to "$2"
% An implicit type conversion from an ansi string type to an unicode string type is
% encountered. To avoid this warning perform an explicit type conversion.
type_w_implicit_string_cast_loss=04105_W_Implicit string type conversion with potential data loss from "$1" to "$2"
% An implicit type conversion from an unicode string type to an ansi string type is
% encountered. This conversion can lose data since not all unicode characters may be represented in the codepage of
% destination string type.
type_w_explicit_string_cast=04106_-W_Explicit string typecast from "$1" to "$2"
% An explicit typecast from an ansi string type to an unicode string type is
% encountered. This warning is off by default. You can turn it on to see all suspicious string conversions.
type_w_explicit_string_cast_loss=04107_-W_Explicit string typecast with potential data loss from "$1" to "$2"
% An explicit typecast from an unicode string type to an ansi string type is
% encountered. This conversion can lose data since not all unicode characters may be represented in the codepage of
% destination string type. This warning is off by default. You can turn it on to see all the places with lossy string
% conversions.
type_w_unicode_data_loss=04108_W_Unicode constant cast with potential data loss
% Conversion from a WideChar to AnsiChar can lose data since now all unicode characters may be represented in the current
% system codepage
% You can nest function definitions only 31 levels deep.
type_e_range_check_error_bounds=04109_E_range check error while evaluating constants ($1 must be between $2 and $3)
type_w_range_check_error_bounds=04110_W_range check error while evaluating constants ($1 must be between $2 and $3)
% The constants are outside their allowed range.
type_e_type_not_allowed_for_default=04111_E_This type is not supported for the Default() intrinsic
% Some types like for example Text and File Of X are not supported by the Default intrinsic.
type_e_java_class_method_not_static_virtual=04112_E_JVM virtual class methods cannot be static
% Virtual class methods cannot be static when targeting the JVM platform, because
% the self pointer is required for correct dispatching.
type_e_invalid_final_assignment=04113_E_Final (class) fields can only be assigned in their class' (class) constructor
% It is only possible to assign a value to a final (class) field inside a (class) constructor of its owning class.
type_e_no_managed_formal_assign_typecast=04114_E_It is not possible to typecast untyped parameters on managed platforms, simply assign a value to them instead.
% On managed platforms, untyped parameters are translated by the compiler into
% the equivalent of \var{var x: BaseClassType}. Non-class-based types passed to
% such parameters are automatically wrapped (or boxed) in a class, and after the
% call the potentially modified value is assigned back to the original variable.
% On the caller side, changing untyped var/out parameters happens by simply assigning
% values to them (either class-based or primitive ones). On the caller side,
% they will be extracted and if their type does not match the original variable's,
% an exception will be raised.
type_e_no_managed_assign_generic_typecast=04115_E_The assignment side of an expression cannot be typecasted to a supertype on managed platforms
% Managed platforms guarantee type safety at the bytecode level. This means that the virtual machine must be able
% to statically determine that no type-unsafe assignments or operations occur. By assigning a parent class type to a
% variable of a child type by typecasting the assignment side to the parent class type, the type safety would no
% longer be guaranteed and the generated code would fail verification at run time time.
type_w_interface_lower_visibility=04116_-W_The interface method "$1" raises the visibility of "$2" to public when accessed via an interface instance
type_e_interface_lower_visibility=04117_E_The interface method "$1" has a higher visibility (public) than "$2"
% All methods in an interface have always public visibility. That means that if
% an interface method is implemented using a (strict) protected or private method,
% this method is actually publicly accessible via the interface. On the JVM
% target this situation results in an error because the JVM rejects such
% attempts to circumvent the visibility rules. On other targets this is a
% warning that is disabled by default because such situations are common
% practice, but it can be enabled in case you are concerned with keeping your
% code compilable for the JVM target.
type_e_typeof_requires_vmt=04118_E_TYPEOF can only be used on object types with VMT
% Typeof() intrinsic returns pointer to VMT of its argument. It cannot be used on object types that do not have VMT.
type_e_invalid_default_value=04119_E_It is not possible to define a default value for a parameter of type "$1"
% Parameters declared as structured types, such as files, variants, non-dynamic
% arrays and TP-style objects, cannot have a default value.
type_e_type_not_allowed_for_type_helper=04120_E_Type "$1" cannot be extended by a type helper
% Types like procedural variables cannot be extended by type helpers
type_e_procedure_must_be_far=04121_E_Procedure or function must be far in order to allow taking its address: "$1"
% In certain i8086 memory models (medium, large and huge), procedures and functions
% have to be declared 'far' in order to allow their address to be taken.
type_w_instance_abstract_class=04122_W_Creating an instance of abstract class "$1"
% The specified class is declared as \var{abstract} and thus no instance of this class
% should be created. This is merely a warning for Delphi compatibility.
type_e_function_reference_kind=04123_E_Subroutine references cannot be declared as "of object" or "is nested", they can always refer to any kind of subroutine
% Subroutine references can refer to any kind of subroutine and hence do not
% require specialisation for methods or nested subroutines.
type_e_anonymous_function_unsupported=04999_E_Function references are not yet supported, only blocks (add "cdecl;" at the end)
% Remove this error message once Delphi-style anonymous are implemented. It has
% number 4999 so as not to result in a gap in the error message numbering once
% it's removed.
% \end{description}
#
# Symtable
#
# 05095 is the last used one
#
% \section{Symbol handling}
% This section lists all the messages that concern the handling of symbols.
% This means all things that have to do with procedure and variable names.
% \begin{description}
sym_e_id_not_found=05000_E_Identificateur "$1" non trouvé
% The compiler doesn't know this symbol. Usually happens when you misspel
% the name of a variable or procedure, or when you forgot to declare a
% variable.
sym_f_internal_error_in_symtablestack=05001_F_Erreur interne dans SymTableStack()
% An internal error occurred in the compiler; If you encounter such an error,
% please contact the developers and try to provide an exact description of
% the circumstances in which the error occurs.
sym_e_duplicate_id=05002_E_Double déclaration de l'identificateur "$1"
% The identifier was already declared in the current scope.
sym_h_duplicate_id_where=05003_H_Identificateur déjà défini dans $1 à la ligne $2
% The identifier was already declared in a previous scope.
sym_e_unknown_id=05004_E_Identificateur "$1" inconnu
% The identifier encountered has not been declared, or is used outside the
% scope where it is defined.
sym_e_forward_not_resolved=05005_E_Déclaration forward "$1" non résolue
% This can happen in two cases:
% \begin{itemize}
% \item This happens when you declare a function (in the \var{interface} part, or
% with a \var{forward} directive, but do not implement it.
% \item You reference a type which isn't declared in the current \var{type}
% block.
% \end{itemize}
sym_e_error_in_type_def=05007_E_Erreur dans la définition du type
% There is an error in your definition of a new array type:
% \item One of the range delimiters in an array declaration is erroneous.
% For example, \var{Array [1..1.25]} will trigger this error.
sym_e_forward_type_not_resolved=05009_E_Déclaration forward "$1" non résolue
% A symbol was forward defined, but no declaration was encountered.
sym_e_only_static_in_static=05010_E_Seules les variables statiques peuvent être utilisées dans les méthodes statiques ou en dehors des méthodes
% A static method of an object can only access static variables.
sym_e_type_must_be_rec_or_object_or_class=05012_E_Record or object or class type expected
% The variable or expression isn't of the type \var{record} or \var{object} or \var{class}.
sym_e_no_instance_of_abstract_object=05013_E_Les instances de classes ou les objets avec une méthode abstraite ne sont pas autorisés
% You are trying to generate an instance of a class which has an abstract
% method that wasn't overridden.
sym_w_label_not_defined=05014_W_Label non défini $1
% A label was declared, but not defined.
sym_e_label_used_and_not_defined=05015_E_Le Label "$1" est utilisé mais indéfini
% A label was declared and used, but not defined.
sym_e_ill_label_decl=05016_E_Déclaration de label illégale
% This error should never happen; it occurs if a label is defined outside a
% procedure or function.
sym_e_goto_and_label_not_supported=05017_E_GOTO et LABEL non supportés (utilisez l'option -Sg)
% You must compile a program which has \var{label}s and \var{goto} statements
% with the \var{-Sg} switch. By default, \var{label} and \var{goto} aren't
% supported.
sym_e_label_not_found=05018_E_Label non trouvé
% A \var{goto label} was encountered, but the label isn't declared.
sym_e_id_is_no_label_id=05019_E_L'identificateur n'est pas un label
% The identifier specified after the \var{goto} isn't of type label.
sym_e_label_already_defined=05020_E_Label déjà défini
% You are defining a label twice. You can define a label only once.
sym_e_ill_type_decl_set=05021_E_Déclaration de type d'éléments d'ensemble illégale
% The declaration of a set contains an invalid type definition.
sym_e_class_forward_not_resolved=05022_E_Déclaration forward de classe "$1" non résolue
% You declared a class, but you did not implement it.
sym_n_unit_not_used=05023_H_L'unité $1 n'est pas utilisée par $2
% The unit referenced in the \var{uses} clause is not used.
sym_h_para_identifier_not_used=05024_H_Le paramètre "$1" n'est pas utilisé
% The identifier was declared (locally or globally) but
% was not used (locally or globally).
sym_n_local_identifier_not_used=05025_N_La variable locale "$1" n'est pas utilisée
% You have declared, but not used a variable in a procedure or function
% implementation.
sym_h_para_identifier_only_set=05026_H_La valeur du paramètre "$1" est définie mais jamais utilisée
% The identifier was declared (locally or globally)
% set but not used (locally or globally).
sym_n_local_identifier_only_set=05027_N_La variable locale "$1" a une valeur mais n'est jamais utilisée
% The variable in a procedure or function
% implementation is declared, set but never used.
sym_h_local_symbol_not_used=05028_H_Le symbole local $1 "$2" n'est pas utilisé
% A local symbol is never used.
sym_n_private_identifier_not_used=05029_N_Le champ privé "$1.$2" n'est jamais utilisé
% The indicated private field is defined, but is never used in the code.
sym_n_private_identifier_only_set=05030_N_Le champ privé "$1.$2" a une valeur mais n'est jamais utilisé
% The indicated private field is declared, assigned but never read.
sym_n_private_method_not_used=05031_N_La méthode privée "$1.$2" n'est jamais utilisée
% The indicated private method is declared but is never used in the code.
sym_e_set_expected=05032_E_Type ensemble attendu
% The variable or expression is not of type \var{set}. This happens in an
% \var{in} statement.
sym_w_function_result_not_set=05033_W_Le résultat de la fonction semble indéfini
% You can get this warning if the compiler thinks that a function return
% value is not set. This will not be displayed for assembler procedures,
% or procedures that contain assembler blocks.
sym_w_wrong_C_pack=05034_W_Le type $1 n'est pas aligné correctement pour C dans l'enregistrement courant
% Arrays with sizes not multiples of 4 will be wrongly aligned
% for C structures.
sym_e_illegal_field=05035_E_Identificateur de champ "$1" inconnu
% The field doesn't exist in the record/object definition.
sym_w_uninitialized_local_variable=05036_W_La variable locale "$1" ne semble pas être initialisée
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. appears in the right-hand-side of an expression) when it
% was not initialized first (i.e. appeared in the left-hand side of an
% assigment)
sym_w_uninitialized_variable=05037_W_La variable "$1" ne semble pas être initialisée
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. appears in the right-hand-side of an expression) when it
% was not initialized first (i.e. appeared in the left-hand side of an
% assigment)
sym_e_id_no_member=05038_E_L'identificateur "$1" n'a pas de membres
% This error is generated when an identifier of a record,
% field, or method is accessed while it is not defined.
sym_h_param_list=05039_H_Déclaration trouvée: $1
% You get this when you use the \var{-vh} switch. In case an overloaded
% procedure is not found, then all candidate overloaded procedures are
% listed, with their parameter lists.
sym_e_segment_too_large=05040_E_Donnée trop grande (max. 2GB)
% You get this when you declare a data element whose size exceeds the
% prescribed limit (2 Gb on 80386+/68020+ processors)
sym_e_no_matching_implementation_found=05042_E_Aucune implémentation correspondante pour la méthode "$1" trouvée dans l'interface
% There was no matching method found which could implement the interface
% method. Check argument types and result type of the methods.
sym_w_deprecated_symbol=05043_W_Le symbole "$1" est déprécié
% This means that a symbol (a variable, routine, etc...) which is
% declared as \var{deprecated} is used. Deprecated symbols may no longer
% be available in newer versions of the unit / library. Usage of this symbol
% should be avoided as much as possible.
sym_w_non_portable_symbol=05044_W_Le symbole "$1" n'est pas portable
% This means that a symbol (a variable, routine, etc...) which is
% declared as \var{platform} is used. This symbol's value, usage
% and availability is platform specific and should not be used
% if the source code must be portable.
sym_w_non_implemented_symbol=05055_W_Le symbole "$1" n'est pas implémenté
% This means that a symbol (a variable, routine, etc...) which is
% declared as \var{unimplemented} is used. This symbol is defined,
% but is not yet implemented on this specific platform.
sym_e_cant_create_unique_type=05056_E_Impossible de créer un type unique depuis ce type
% Only simple types like ordinal, float and string types are supported when
% redefining a type with \var{type newtype = type oldtype;}.
sym_h_uninitialized_local_variable=05057_H_La variable locale "$1" ne semble pas initialisée
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. appears in the right-hand-side of an expression) when it
% was not initialized first (i.e. appeared in the left-hand side of an
% assigment)
sym_h_uninitialized_variable=05058_H_La variable "$1" ne semble pas initialisée
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. appears in the right-hand-side of an expression) when it
% was not initialized first (i.e. appeared in the left-hand side of an
% assigment)
sym_w_function_result_uninitialized=05059_W_La variable Result de la fonction ne semble pas initialisée
% This message is displayed if the compiler thinks that the function result
% variable will be used (i.e. appears in the right-hand-side of an expression)
% before it is initialized (i.e. appeared in the left-hand side of an
% assigment)
sym_h_function_result_uninitialized=05060_H_La variable Result de la fonction ne semble pas initialisée
% This message is displayed if the compiler thinks that the function result
% variable will be used (i.e. appears in the right-hand-side of an expression)
% before it is initialized (i.e. appeared in the left-hand side of an
% assigment)
sym_w_identifier_only_read=05061_W_La variable "$1" est lue mais ne reçoit de valeur nulle part
% You have read the value of a variable, but nowhere assigned a value to
% it.
% \end{description}
#
# Codegenerator
#
# 06040 is the last used one
#
% \section{Code generator messages}
% This section lists all messages that can be displayed if the code
% generator encounters an error condition.
% \begin{description}
sym_h_abstract_method_list=05062_H_Found abstract method: $1
% When getting a warning about constructing a class/object with abstract methods
% you get this hint to assist you in finding the affected method.
sym_w_experimental_symbol=05063_W_Symbol "$1" is experimental
% This means that a symbol (a variable, routine, etc...) which is
% declared as \var{experimental} is used. Experimental symbols
% might disappear or change semantics in future versions. Usage of this symbol
% should be avoided as much as possible.
sym_w_forward_not_resolved=05064_W_Forward declaration "$1" not resolved, assumed external
% This happens if you declare a function in the \var{interface} of a unit in macpas mode,
% but do not implement it.
sym_w_library_symbol=05065_W_Symbol "$1" is belongs to a library
% This means that a symbol (a variable, routine, etc...) which is
% declared as \var{library} is used. Library symbols may not be
% available in other libraries.
sym_w_deprecated_symbol_with_msg=05066_W_Symbol "$1" is deprecated: "$2"
% This means that a symbol (a variable, routine, etc...) which is
% declared as \var{deprecated} is used. Deprecated symbols may no longer
% be available in newer versions of the unit / library. Use of this symbol
% should be avoided as much as possible.
sym_e_no_enumerator=05067_E_Cannot find an enumerator for the type "$1"
% This means that compiler cannot find an appropriate enumerator to use in the for-in loop.
% To create an enumerator you need to define an operator enumerator or add a public or published
% GetEnumerator method to the class or object definition.
sym_e_no_enumerator_move=05068_E_Cannot find a "MoveNext" method in enumerator "$1"
% This means that compiler cannot find a public MoveNext method with the Boolean return type in
% the enumerator class or object definition.
sym_e_no_enumerator_current=05069_E_Cannot find a "Current" property in enumerator "$1"
% This means that compiler cannot find a public Current property in the enumerator class or object
% definition.
sym_e_objc_para_mismatch=05070_E_Mismatch between number of declared parameters and number of colons in message string.
% In Objective-C, a message name automatically contains as many colons as parameters.
% In order to prevent mistakes when specifying the message name in FPC, the compiler
% checks whether this is also the case here. Note that in case of messages taking a
% variable number of arguments translated to FPC via an \var{array of const} parameter,
% this final \var{array of const} parameter is not counted. Neither are the hidden
% \var{self} and \var{\_cmd} parameters.
sym_n_private_type_not_used=05071_N_Private type "$1.$2" never used
% The indicated private type is declared but is never used in the code.
sym_n_private_const_not_used=05072_N_Private const "$1.$2" never used
% The indicated private const is declared but is never used in the code.
sym_n_private_property_not_used=05073_N_Private property "$1.$2" never used
% The indicated private property is declared but is never used in the code.
sym_w_deprecated_unit=05074_W_Unit "$1" is deprecated
% This means that a unit which is
% declared as \var{deprecated} is used. Deprecated units may no longer
% be available in newer versions of the library. Use of this unit
% should be avoided as much as possible.
sym_w_deprecated_unit_with_msg=05075_W_Unit "$1" is deprecated: "$2"
% This means that a unit which is
% declared as \var{deprecated} is used. Deprecated units may no longer
% be available in newer versions of the library. Use of this unit
% should be avoided as much as possible.
sym_w_non_portable_unit=05076_W_Unit "$1" is not portable
% This means that a unit which is
% declared as \var{platform} is used. This unit use
% and availability is platform specific and should not be used
% if the source code must be portable.
sym_w_library_unit=05077_W_Unit "$1" is belongs to a library
% This means that a unit which is
% declared as \var{library} is used. Library units may not be
% available in other libraries.
sym_w_non_implemented_unit=05078_W_Unit "$1" is not implemented
% This means that a unit which is
% declared as \var{unimplemented} is used. This unit is defined,
% but is not yet implemented on this specific platform.
sym_w_experimental_unit=05079_W_Unit "$1" is experimental
% This means that a unit which is
% declared as \var{experimental} is used. Experimental units
% might disappear or change semantics in future versions. Usage of this unit
% should be avoided as much as possible.
sym_e_formal_class_not_resolved=05080_E_No complete definition of the formally declared class "$1" is in scope
% Objecive-C and Java classes can be imported formally, without using the unit in which it is fully declared.
% This enables making forward references to such classes and breaking circular dependencies amongst units.
% However, as soon as you wish to actually do something with an entity of this class type (such as
% access one of its fields, send a message to it, or use it to inherit from), the compiler requires the full definition
% of the class to be in scope.
sym_e_interprocgoto_into_init_final_code_not_allowed=05081_E_Gotos into initialization or finalization blocks of units are not allowed
% Gotos into initialization or finalization blockse of units are not allowed.
sym_e_external_class_name_mismatch1=05082_E_Invalid external name "$1" for formal class "$2"
sym_e_external_class_name_mismatch2=05083_E_Complete class definition with external name "$1" here
% When a class is declared using a formal external definition, the actual external
% definition (if any) must specify the same external name as the formal definition
% (since both definitions refer to the same actual class type).
sym_w_library_overload=05084_W_Possible library conflict: symbol "$1" from library "$2" also found in library "$3"
% Some OS do not have library specific namespaces, for those
% OS, the function declared as "external 'libname' name 'funcname'",
% the 'libname' part is only a hint, funcname might also be loaded
% by another library. This warning appears if 'funcname' is used twice
% with two different library names.
sym_e_duplicate_id_create_java_constructor=05085_E_Cannot add implicit constructor 'Create' because identifier already used by "$1"
% Java does not automatically add inherited constructors to child classes, so that they can be hidden.
% However, if a class does not explicitly declare at least one constructor, the compiler is
% required to add a public, parameterless constructor. In Java, constructors are nameless,
% but in FPC they are all called ``Create''. Therefore, if you do not add a constructor to
% a Java class and furthermore use the ``Create'' identifier for another entity (e.g., a field,
% or a parameterless method), the compiler cannot satisfy this requirement.
sym_e_no_matching_inherited_parameterless_constructor=05086_E_Cannot generate default constructor for class, because parent has no parameterless constructor
% Java does not automatically add inherited constructors to child classes, so that they can be hidden.
% However, if a class does not explicitly declare at least one constructor, the compiler is
% required to add a public, parameterless constructor. This compiler must then call
% the parameterless constructor from the parent class inside this added constructor.
% This is however impossible if the parent class does not declare such a constructor.
% In this case you must add a valid constructor yourself.
sym_d_adding_helper_for=05087_D_Adding helper for $1
% A helper for the mentioned type is added to the current scope
sym_e_param_list=05088_E_Found declaration: $1
% This message shows all overloaded declarations in case of an error.
sym_w_uninitialized_managed_local_variable=05089_W_Local variable "$1" of a managed type does not seem to be initialized
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. it appears in the right-hand side of an expression) when it
% was not initialized first (i.e. appeared in the left-hand side of an
% assignment). Since the variable is managed, i. e. implicitly initialized by the compiler, this might be intended behaviour and
% does not necessarily mean that the code is wrong.
sym_w_uninitialized_managed_variable=05090_W_Variable "$1" of a managed type does not seem to be initialized
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. it appears in the right-hand side of an expression) when it
% was not initialized first (i.e. appeared in the left-hand side of an
% assignment). Since the variable is managed, i. e. implicitly initialized by the compiler, this might be intended behaviour and
% does not necessarily mean that the code is wrong.
sym_h_uninitialized_managed_local_variable=05091_H_Local variable "$1" of a managed type does not seem to be initialized
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. it appears in the right-hand side of an expression) when it
% was not initialized first (i.e. it did not appear in the left-hand side of an
% assignment). Since the variable is managed, i. e. implicitly initialized by the compiler, this might be intended behaviour and
% does not necessarily mean that the code is wrong.
sym_h_uninitialized_managed_variable=05092_H_Variable "$1" of a managed type does not seem to be initialized
% This message is displayed if the compiler thinks that a variable will
% be used (i.e. it appears in the right-hand side of an expression) when it
% was not initialized first (i.e. t did not appear in the left-hand side of an
% assignment). Since the variable is managed, i. e. implicitly initialized by the compiler, this might be intended behaviour and
% does not necessarily mean that the code is wrong.
sym_w_managed_function_result_uninitialized=05093_W_function result variable of a managed type does not seem to initialized
% This message is displayed if the compiler thinks that the function result
% variable will be used (i.e. it appears in the right-hand side of an expression)
% before it is initialized (i.e. before it appeared in the left-hand side of an
% assignment). Since the variable is managed, i. e. implicitly initialized by the compiler, this might be intended behaviour and
% does not necessarily mean that the code is wrong.
sym_h_managed_function_result_uninitialized=05094_H_Function result variable of a managed type does not seem to be initialized
% This message is displayed if the compiler thinks that the function result
% variable will be used (i.e. it appears in the right-hand side of an expression)
% before it is initialized (i.e. it appears in the left-hand side of an
% assignment). Since the variable is managed, i. e. implicitly initialized by the compiler, this might be intended behaviour and
% does not necessarily mean that the code is wrong.
sym_w_duplicate_id=05095_W_Duplicate identifier "$1"
% The identifier was already declared in an Objective-C category that's in the
% same scope as the current identifier. This is a warning instead of an error,
% because while this hides the identifier from the category, there are often
% many unused categories in scope.
% \end{description}
#
# Codegenerator
#
# 06049 is the last used one
#
% \section{Code generator messages}
% This section lists all messages that can be displayed if the code
% generator encounters an error condition.
% \begin{description}
cg_e_parasize_too_big=06009_E_La taille de la liste de paramètre dépasse 65535 octets
% The I386 processor limits the parameter list to 65535 bytes (the \var{RET}
% instruction causes this)
cg_e_file_must_call_by_reference=06012_E_Les paramètres de type File doivent être passés par adresse
% You cannot specify files as value parameters, i.e. they must always be
% declared \var{var} parameters.
cg_e_cant_use_far_pointer_there=06013_E_L'utilisation d'un pointeur long n'est pas autorisée ici
% Free Pascal doesn't support far pointers, so you cannot take the address of
% an expression which has a far reference as a result. The \var{mem} construct
% has a far reference as a result, so the following code will produce this
% error:
% \begin{verbatim}
% var p : pointer;
% ...
% p:=@mem[a000:000];
% \end{verbatim}
cg_e_dont_call_exported_direct=06015_E_Les fonctions déclarées EXPORT ne peuvent pas être appelées
% No longer in use.
cg_w_member_cd_call_from_method=06016_W_Appel probablement illégal d'un constructeur ou d'un destructeur
% The compiler detected that a constructor or destructor is called within a
% a method. This will probably lead to problems, since constructors / destructors
% require parameters on entry.
cg_n_inefficient_code=06017_N_Code inefficace
% Your statement seems dubious to the compiler.
cg_w_unreachable_code=06018_W_Code inaccessible
% You specified a construct which will never be executed. Example:
% \begin{verbatim}
% while false do
% begin
% {.. code ...}
% end;
% \end{verbatim}
cg_e_cant_call_abstract_method=06020_E_Les méthodes abstraites ne peuvent pas être appelées directement
% You cannot call an abstract method directy, instead you must call a
% overriding child method, because an abstract method isn't implemented.
cg_d_register_weight=06027_DL_Registre $1 poids $2 $3
% Debugging message. Shown when the compiler considers a variable for
% keeping in the registers.
cg_d_stackframe_omited=06029_DL_Cadre de pile omis
% Some procedure/functions do not need a complete stack-frame, so it is omitted.
% This message will be displayed when the {-vd} switch is used.
cg_e_unable_inline_object_methods=06031_E_Un object ou des méthodes de classe ne peuvent pas être "inline".
% You cannot have inlined object methods.
cg_e_unable_inline_procvar=06032_E_Les appels à des variables procédure ne peuvent pas être "inline".
% A procedure with a procedural variable call cannot be inlined.
cg_e_no_code_for_inline_stored=06033_E_Pas de code pour la procédure inline stockée
% The compiler couldn't store code for the inline procedure.
cg_e_can_access_element_zero=06035_E_Impossible d'accéder à l'élément zéro d'une chaîne ANSI, large ou longue, utilisez à la place (set)length
% You should use \var{setlength} to set the length of an ansi/wide/longstring
% and \var{length} to get the length of such a string types
cg_e_cannot_call_cons_dest_inside_with=06037_E_Constructeurs et destructeurs ne peuvent pas être appelés à l'intérieur d'une clause 'with'
% Inside a \var{with} clause you cannot call a constructor or destructor for the
% object you have in the \var{with} clause.
cg_e_cannot_call_message_direct=06038_E_Impossible d'appeler directement les méthodes du gestionnaire de messages
% A message method handler method cannot be called directly if it contains an
% explicit self argument
cg_e_goto_inout_of_exception_block=06039_E_Saut à l'intérieur ou en dehors d'un bloc de traitement d'une exception
% It is not allowed to jump in or outside of an exception block like \var{try..finally..end;}:
% \begin{verbatim}
% label 1;
%
% ...
%
% try
% if not(final) then
% goto 1; // this line will cause an error
% finally
% ...
% end;
% 1:
% ...
% \end{verbatim}
cg_e_control_flow_outside_finally=06040_E_Les instructions de contrôle d'exécution ne sont pas autorisées dans un bloc finally
% It isn't allowed to use the control flow statements \var{break},
% \var{continue} and \var{exit}
% inside a finally statement. The following example shows the problem:
% \begin{verbatim}
% ...
% try
% p;
% finally
% ...
% exit; // This exit ISN'T allowed
% end;
% ...
%
% \end{verbatim}
% If the procedure \var{p} raises an exception the finally block is
% executed. If the execution reaches the exit, it's unclear what to do:
% exiting the procedure or searching for another exception handler
cg_w_parasize_too_big=06041_W_La taille des paramètres dépasse la limite supportée par certains processeurs.
% This indicates that you are declaring more than 64K of parameters, which
% might not be supported on other processor targets.
cg_w_localsize_too_big=06042_W_La taille de la variable locale dépasse la limite supportée par certains processeurs.
% This indicates that you are declaring more than 32K of local variables, which
% might not be supported on other processor targets.
cg_e_localsize_too_big=06043_E_La taille des variables locales dépasse la limite supportée
% This indicates that you are declaring more than 32K of local variables, which
% is not supported by this processor.
cg_e_break_not_allowed=06044_E_BREAK non autorisé
% You're trying to use \var{break} outside a loop construction.
cg_e_continue_not_allowed=06045_E_CONTINUE non autorisé
% You're trying to use \var{continue} outside a loop construction.
cg_f_unknown_compilerproc=06046_F_Procédure "$1" inconnue. Verifiez que vous utilisez la bonne version de bibliothèque d'exécution.
% The compiler expects that the runtime library contains some subrountines. If you see this error
% and you didn't mess with the runtime library, it's very likely that the runtime library
% you're using doesn't match the used compiler. If you changed the runtime library this error means
% that you removed a subroutine which the compiler needs for internal use.
% \end{description}
# EndOfTeX
#
# Assembler reader
#
# 07097 is the last used one
#
cg_f_unknown_system_type=06047_F_Cannot find system type "$1". Check if you use the correct run time library.
% The compiler expects that the runtime library contains certain type definitions. If you see this error
% and you didn't change the runtime library code, it's very likely that the runtime library
% you're using doesn't match the compiler in use. If you changed the runtime library this error means
% that you removed a type which the compiler needs for internal use.
cg_h_inherited_ignored=06048_H_Inherited call to abstract method ignored
% This message appears only in Delphi mode when you call an abstract method
% of a parent class via \var{inherited;}. The call is then ignored.
cg_e_goto_label_not_found=06049_E_Goto label "$1" not defined or optimized away
% The label used in the goto definition is not defined or optimized away by the
% unreachable code elemination.
cg_f_unknown_type_in_unit=06050_F_Cannot find type "$1" in unit "$2". Check if you use the correct run time library.
% The compiler expects that the runtime library contains certain type definitions. If you see this error
% and you didn't change the runtime library code, it's very likely that the runtime library
% you're using doesn't match the compiler in use. If you changed the runtime library this error means
% that you removed a type which the compiler needs for internal use.
cg_e_interprocedural_goto_only_to_outer_scope_allowed=06051_E_Interprocedural gotos are allowed only to outer subroutines
% Gotos between subroutines are only allowed if the goto jumps from an inner to an outer subroutine or
% from a subroutine to the main program
cg_e_labels_cannot_defined_outside_declaration_scope=06052_E_Label must be defined in the same scope as it is declared
% In ISO mode, labels must be defined in the same scope as they are declared.
cg_e_goto_across_procedures_with_exceptions_not_allowed=06053_E_Leaving procedures containing explicit or implicit exceptions frames using goto is not allowed
% Non-local gotos might not be used to leave procedures using exceptions either implicitly or explicitly. Procedures
% which use automated types like ansistrings or class constructurs are affected by this too.
cg_e_mod_only_defined_for_pos_quotient=06054_E_In ISO mode, the mod operator is defined only for positive quotient
% In ISO pascal, only positive values are allowed for the quotient: \var{n mod m} is only valid if \var{m>0}.
cg_d_autoinlining=06055_DL_Auto inlining: $1
% Due to auto inlining turned on, the compiler auto inlines this subroutine.
cg_e_function_not_support_by_selected_instruction_set=06056_E_The function used, is not supported by the selected instruction set: $1
% Some functions cannot be implemented efficiently for certain instruction sets, one example is fused multiply/add.
% To avoid very inefficient code, the compiler complains in this case, so either select another instruction set
% or replace the function call by alternative code
cg_f_max_units_reached=06057_F_Maximum number of units ($1) reached for the current target
% Depending of target architecture, the number of units is limited. This limit
% has been reached. A unit counts only if it contains initialization or finalization count.
%
% \end{description}
# EndOfTeX
#
# Assembler reader
#
# 07125 is the last used one
#
asmr_d_start_reading=07000_DL_Début d'analyse assembleur de style $1
% This informs you that an assembler block is being parsed
asmr_d_finish_reading=07001_DL_Analyse assembleur de style $1 terminée
% This informs you that an assembler block has finished.
asmr_e_none_label_contain_at=07002_E_Un identificateur qui n'est pas un label contient @
% A identifier which isn't a label can't contain a @.
asmr_e_building_record_offset=07004_E_Erreur de construction de l'offset du record
% An error occurred while building the offset of a record/object
% structure, this can happend when there is no field specified at all or
% an unknown field identifier is used.
asmr_e_offset_without_identifier=07005_E_OFFSET utilisé sans identificateur
% You can only use OFFSET with an identifier. Other syntaxes aren't
% supported
asmr_e_type_without_identifier=07006_E_TYPE utilisé sans identificateur
% You can only use TYPE with an identifier. Other syntaxes aren't
% supported
asmr_e_no_local_or_para_allowed=07007_E_Impossible d'utiliser une variable locale ou des paramètres ici
% You can't use a local variable or parameter here, mostly because the
% addressing of locals and parameters is done using the frame pointer register so the
% address can't be obtained directly.
asmr_e_need_offset=07008_E_Utilisation d'OFFSET nécessaire
% You need to use OFFSET <id> here to get the address of the identifier.
asmr_e_need_dollar=07009_E_Utilisation de $ nécessaire
% You need to use $<id> here to get the address of the identifier.
asmr_e_cant_have_multiple_relocatable_symbols=07010_E_Impossible d'utiliser plusieurs symboles relogeables
% You can't have more than one relocatable symbol (variable/typed constant)
% in one argument.
asmr_e_only_add_relocatable_symbol=07011_E_Les symboles relogeables ne peuvent qu'être ajoutés
% Relocatable symbols (variable/typed constant) can't be used with other
% operators. Only addition is allowed.
asmr_e_invalid_constant_expression=07012_E_Expression contante incorrecte
% There is an error in the constant expression.
asmr_e_relocatable_symbol_not_allowed=07013_E_Symbole relogeable non autorisé
% You can't use a relocatable symbol (variable/typed constant) here.
asmr_e_invalid_reference_syntax=07014_E_Syntaxe de référence incorrecte
% There is an error in the reference.
asmr_e_local_para_unreachable=07015_E_Impossible d´atteindre $1 depuis ce code
% You can not read directly the value of a local variable or parameter
% of a higher level procedure in assembler code (except for
% local assembler code without parameter nor locals).
asmr_e_local_label_not_allowed_as_ref=07016_E_Les symboles locaux et les labels ne sont pas autorisés en tant que références
% You can't use local symbols/labels as references
asmr_e_wrong_base_index=07017_E_Utilisation d'un registre de base et d'un index de registre incorrecte
% There is an error with the base and index register, they are
% probably incorrect
asmr_w_possible_object_field_bug=07018_W_Erreur possible dans la gestion d'un champ d'objet
% Fields of objects or classes can be reached directly in normal or objfpc
% modes but TP and Delphi modes treat the field name as a simple offset.
asmr_e_wrong_scale_factor=07019_E_Facteur d'échelle spécifié incorrect
% The scale factor given is wrong, only 1,2,4 and 8 are allowed
asmr_e_multiple_index=07020_E_Utilisation d'index de registre multiples
% You are trying to use more than one index register
asmr_e_invalid_operand_type=07021_E_Type de paramètre incorrect
% The operand type doesn't match with the opcode used
asmr_e_invalid_string_as_opcode_operand=07022_E_Paramètre chaîne incorrect pour le code opération: $1
% The string specified as operand is not correct with this opcode
asmr_w_CODE_and_DATA_not_supported=07023_W_@CODE et @DATA non supportés
% @CODE and @DATA are unsupported and are ignored.
asmr_e_null_label_ref_not_allowed=07024_E_Référence à un label Null non autorisée
asmr_e_expr_zero_divide=07025_E_Division par zéro dans l'évaluateur assembleur
% There is a division by zero in a constant expression
asmr_e_expr_illegal=07026_E_Expression illégale
% There is an illegal expression in a constant expression
asmr_e_escape_seq_ignored=07027_E_Séquence d'échappement ignorée: $1
% There is a C-styled string, but the escape sequence in the string
% is unknown, and is therefore ignored
asmr_e_invalid_symbol_ref=07028_E_Référence au symbole incorrecte
asmr_w_fwait_emu_prob=07029_W_Fwait peut causer des problèmes d'émulation avec emu387
asmr_w_fadd_to_faddp=07030_W_$1 sans paramètre traduit en $1P
asmr_w_enter_not_supported_by_linux=07031_W_Instruction ENTER non supportée par le noyau Linux
% ENTER instruction can generate a stack page fault that is not
% caught correctly by the i386 Linux page handler.
asmr_w_calling_overload_func=07032_W_Appel d'une fonction surchargée en assembleur
% There is a call to an overloaded method in the assembler block,
% this might be the sign there is a problem
asmr_e_unsupported_symbol_type=07033_E_Type de symbole non supporté
asmr_e_constant_out_of_bounds=07034_E_Valeur de constante hors intervalle
asmr_e_error_converting_decimal=07035_E_Erreur de conversion décimale $1
% A constant decimal value does not have the correct syntax
asmr_e_error_converting_octal=07036_E_Erreur de conversion octale $1
% A constant octal value does not have the correct syntax
asmr_e_error_converting_binary=07037_E_Erreur de conversion binaire $1
% A constant binary value does not have the correct syntax
asmr_e_error_converting_hexadecimal=07038_E_Erreur de conversion hexadecimale $1
% A constant hexadecimal value does not have the correct syntax
asmr_h_direct_global_to_mangled=07039_H_$1 traduit en $2
asmr_w_direct_global_is_overloaded_func=07040_W_$1 est associé(e) à une fonction surchargée
asmr_e_cannot_use_SELF_outside_a_method=07041_E_Impossible d'utiliser SELF en dehors d'une méthode
% There is a reference to the \var{self} symbol while it is not
% allowed. \var{self} can only be referenced inside methods
asmr_e_cannot_use_OLDEBP_outside_nested_procedure=07042_E_Impossible d'utiliser OLDEBP en dehors d'une procédure imbriquée
% There is a reference to the \var{oldebp} symbol while it is not
% allowed. \var{oldebp} can only be referenced inside nested routines
asmr_e_void_function=07043_W_Les procédures ne peuvent pas retourner de valeur en code assembleur
% Trying to return a value while in a procedure. A procedure
% does not have any return value
asmr_e_SEG_not_supported=07044_E_SEG non supporté
asmr_e_size_suffix_and_dest_dont_match=07045_E_La taille du suffixe et celle de la destination ou de la source ne correspondent pas
% The register size and the opcode size suffix don't match. This is
% probably an error in the assembler statement
asmr_w_size_suffix_and_dest_dont_match=07046_W_La taille du suffixe ne correspond pas à celle de la destination ou de la source
% The register size and the opcode size suffix don't match. This is
% probably an error in the assembler statement
asmr_e_syntax_error=07047_E_Erreur de syntaxe assembleur
% There is an assembler syntax error
asmr_e_invalid_opcode_and_operand=07048_E_Combinaison de codes opération et de paramètres incorrecte
% The opcode cannot be used with this type of operand
asmr_e_syn_operand=07049_E_Erreur de syntaxe assembleur dans le paramètre
asmr_e_syn_constant=07050_E_Erreur de syntaxe assembleur dans la constante
asmr_e_invalid_string_expression=07051_E_Expression chaîne incorrecte
asmr_w_const32bit_for_address=07052_W_Constante avec symbole $1 utilisée comme adresse n'est pas un pointeur
% A constant expression represents an address which does not fit
% into a pointer. The address is probably incorrect
asmr_e_unknown_opcode=07053_E_Code opération $1 non reconnu
% This opcode is not known
asmr_e_invalid_or_missing_opcode=07054_E_Code opération incorrect ou manquant
asmr_e_invalid_prefix_and_opcode=07055_E_Combinaison invalide de prefix avec un code opération: $1
asmr_e_invalid_override_and_opcode=07056_E_Combinaison invalide de override avec un code opération: $1
asmr_e_too_many_operands=07057_E_Nombre de paramètres insuffisant
% There are too many operands for this opcode. Check your
% assembler syntax
asmr_w_near_ignored=07058_W_NEAR ignoré
asmr_w_far_ignored=07059_W_FAR ignoré
asmr_e_dup_local_sym=07060_E_Symbole local $1 dupliqué
asmr_e_unknown_local_sym=07061_E_Symbole local $1 inconnu
asmr_e_unknown_label_identifier=07062_E_Identificateur de label $1 inconnu
asmr_e_invalid_register=07063_E_Nom de registre incorrect
% There is an unknown register name used as operand.
asmr_e_invalid_fpu_register=07064_E_Nom de registre de calcul réel incorrect
% There is an unknown register name used as operand.
asmr_w_modulo_not_supported=07066_W_Modulo non supporté
asmr_e_invalid_float_const=07067_E_Constante réelle $1 invalide
% The floating point constant declared in an assembler block is
% invalid.
asmr_e_invalid_float_expr=07068_E_Expression réelle invalide
% The floating point expression declared in an assembler block is
% invalid.
asmr_e_wrong_sym_type=07069_E_Type de symbole incorrect
asmr_e_cannot_index_relative_var=07070_E_Impossible d'indicer directement une variable locale ou un paramètre avec un registre
% Trying to index using a base register a symbol which is already relative
% to a register. This is not possible, and will probably lead to crashes.
asmr_e_invalid_seg_override=07071_E_Expression d'override du segment incorrecte
asmr_w_id_supposed_external=07072_W_Identificateur $1 supposé external
% There is a reference to an undefined symbol. This will not result
% in an error, since the symbol might be external, but may cause
% problems at link time if the symbol is not defined anywhere.
asmr_e_string_not_allowed_as_const=07073_E_Constantes chaînes non autorisées
% Character strings are not allowed as constants.
asmr_e_no_var_type_specified=07074_Type de variable non spécifié
% The syntax expects a type idenfitifer after the dot, but
% none was found.
asmr_w_assembler_code_not_returned_to_text=07075_E_Code assembleur non retourné à la section text
% There was a directive in the assembler block to change sections,
% but there is a missing return to the text section at the end
% of the assembler block. This might cause errors during link time.
asmr_e_not_directive_or_local_symbol=07076_E_$1 n'est pas une directive ou un symbole local
% This symbol is unknown.
asmr_w_using_defined_as_local=07077_E_Utilisation d'un nom défini comme label local
asmr_e_dollar_without_identifier=07078_E_Dollar utilisé sans identificateur
% A constant expression has an identifier which does not start with
% the $ symbol.
asmr_w_32bit_const_for_address=07079_W_Constante 32 bits créée comme adresse
% A constant was used as an address. This is probably an error,
% since using absolute addresses will probably not work.
asmr_n_align_is_target_specific=07080_N_.align dépend de la cible, utilisez .balign ou .p2align
% Using the .align directive is platform specific, and its meaning will vary
% from one platform to another.
asmr_e_cannot_access_field_directly_for_parameters=07081_E_Impossible d'accéder directement aux champs transmis en paramètres
% You should load the parameter first into a register and then access the
% fields using that register.
asmr_e_cannot_access_object_field_directly=07082_E_Impossible d'accéder directement aux champs d'objets ou de classes
% You should load the self pointer first into a register and then access the
% fields using the register as base. By default the self pointer is available
% in the esi register on i386.
asmr_e_unable_to_determine_reference_size=07083_E_Taille non spécifiée et impossibilité de déterminer la taille des paramètres
% You should specify explicitly a size for the reference, because
% the compiler is unable to determine what size (byte,word,dword,etc.) it
% should use for the reference.
asmr_e_cannot_use_RESULT_here=07084_E_Impossible d'utiliser RESULT dans cette fonction
% Some functions which return complex types cannot use the \var{result}
% keyword.
asmr_w_adding_explicit_args_fXX=07086_W_"$1" sans paramètre traduit en "$1 %st,%st(1)"
asmr_w_adding_explicit_first_arg_fXX=07087_W_"$1 %st(n)" traduit en "$1 %st,%st(n)"
asmr_w_adding_explicit_second_arg_fXX=07088_W_"$1 %st(n)" traduit en "$1 %st(n),%st"
asmr_e_invalid_char_smaller=07089_E_Caractère < non autorisé ici
% The shift operator requires the << characters. Only one
% of those characters was found.
asmr_e_invalid_char_greater=07090_E_Caractère > non autorisé ici
% The shift operator requires the >> characters. Only one
% of those characters was found.
asmr_w_align_not_supported=07093_W_ALIGN non supporté
asmr_e_no_inc_and_dec_together=07094_E_Inc et Dec ne peuvent pas être ensemble
% Trying to use an increment and a decrement within the same
% opcode on the 680x0. This is impossible.
asmr_e_invalid_reg_list_in_movem=07095_E_Liste de registres invalide pour l'opération movem
% Trying to use the \var{movem} opcode with invalid registers
% to save or restore.
asmr_e_invalid_reg_list_for_opcode=07096_E_Liste de registres invalide pour le code opération
asmr_e_higher_cpu_mode_required=07097_E_Mode CPU supérieur nécessaire ($1)
% Trying to use an instruction which is not supported in the current
% cpu mode. Use a higher cpu generation to be able to use this
% opcode in your assembler block
asmr_w_unable_to_determine_reference_size_using_dword=07098_W_Taille non spécifiée et impossible de déterminer la taille des paramètres, utilisation de DWORD par défaut
% You should specify explicitly a size for the reference, because
% the compiler is unable to determine what size (byte,word,dword,etc.) it
% should use for the reference. This warning is only used in Delphi mode where
% it falls back to use DWORD as default.
asmr_e_illegal_shifterop_syntax=07099_E_Erreur de syntaxe durant l'analyse d'une opération de décalage
% ARM only; ARM assembler supports a so called shifter operand. The used syntax isn't
% a valid shifter operand. Example for an operation with shifter operand:
% \begin{verbatim}
% asm
% orr r2,r2,r2,lsl #8
% end;
% \end{verbatim}
#
# Assembler/binary writers
#
# 08018 is the last used one
#
asmr_e_packed_element=07100_E_Address of packed component is not at a byte boundary
% Packed components (record fields and array elements) may start at an arbitrary
% bit inside a byte. On CPU which do not support bit-addressable memory (which
% includes all currently supported CPUs by FPC) you will therefore get an error
% message when trying to index arrays with elements whose size is not a multiple
% of 8 bits. The same goes for accessing record fields with such an address.
% multiple of 8 bits.
asmr_w_unable_to_determine_reference_size_using_byte=07101_W_No size specified and unable to determine the size of the operands, using BYTE as default
% You should specify explicitly a size for the reference, because
% the compiler is unable to determine what size (byte,word,dword,etc.) it
% should use for the reference. This warning is only used in Delphi mode where
% it falls back to use BYTE as default.
asmr_w_no_direct_ebp_for_parameter=07102_W_Use of +offset(%ebp) for parameters invalid here
% Using direct 8(%ebp) reference for function/procedure parameters is invalid
% if parameters are in registers.
asmr_w_direct_ebp_for_parameter_regcall=07103_W_Use of +offset(%ebp) is not compatible with regcall convention
% Using direct 8(%ebp) reference for function/procedure parameters is invalid
% if parameters are in registers.
asmr_w_direct_ebp_neg_offset=07104_W_Use of -offset(%ebp) is not recommended for local variable access
% Using -8(%ebp) to access a local variable is not recommended
asmr_w_direct_esp_neg_offset=07105_W_Use of -offset(%esp), access may cause a crash or value may be lost
% Using -8(%esp) to access a local stack is not recommended, as
% this stack portion can be overwritten by any function calls or interrupts.
asmr_e_no_vmtoffset_possible=07106_E_VMTOffset must be used in combination with a virtual method, and "$1" is not virtual
% Only virtual methods have VMT offsets
asmr_e_need_pic_ref=07107_E_Generating PIC, but reference is not PIC-safe
% The compiler has been configured to generate position-independent code
% (PIC), but there are position-dependent references in the current
% handwritten assembler instruction.
asmr_e_mixing_regtypes=07108_E_All registers in a register set must be of the same kind and width
% Instructions on the ARM architecture that take a register set as argument require that all registers
% in this set are of the same kind (e.g., integer, vfp) and width (e.g., single precision, double precision).
asmr_e_empty_regset=07109_E_A register set cannot be empty
% Instructions on the ARM architecture that take a register set as argument require that such a set
% contains at least one register.
asmr_w_useless_got_for_local=07110_W_@GOTPCREL is useless and potentially dangerous for local symbols
% The use of @GOTPCREL supposes an extra indirection that is
% not present if the symbol is local, which might lead to wrong assembler code
asmr_w_general_segment_with_constant=07111_W_Constant with general purpose segment register
% General purpose register should not have constant offsets
% as OS memory allocation might not be compatible with that.
asmr_e_bad_seh_directive_offset=07112_E_Invalid offset value for $1
% Win64 SEH directives have certain restrictions on possible offset values, e.g. they should
% be positive and have 3 or 4 low bits clear.
asmr_e_bad_seh_directive_register=07113_E_Invalid register for $1
% Win64 SEH directives accept only 64-bit integer registers or XMM registers.
asmr_e_seh_in_pure_asm_only=07114_E_SEH directives are allowed only in pure assembler procedures
% Win64 SEH directives are allowed only in pure assembler procedures, not in assembler
% blocks of regular procedures.
asmr_e_unsupported_directive=07115_E_Directive "$1" is not supported for the current target
asmr_e_complex_function_result_location=07116_E_This function's result location cannot be encoded directly in a single operand when "nostackframe" is used
% Functions declared with the \var{nostackframe} modifier do not have a stack frame, and hence
% do not have a local variable to hold the temporary function result. Accesses to the function
% result in such routines directly go to the registers or memory location that will be used
% to return their result to the caller. In some cases this result may be spread over multiple
% registers, in which case it is not possible to access the location via its symbolic name.
% You have to directly use the appropriate register names in this case.
asmr_e_wrong_gotpcrel_intel_syntax=07117_E_GOTPCREL references in Intel assembler syntax cannot contain a base or index register, and their offset must 0.
% The syntax for a gotpcrel PIC memory expression in Intel assembler syntax is
% \verb*[global_symbol wrt ..gotpcrel]*
asmr_e_no_gotpcrel_support=07118_E_The current target does not support GOTPCREL relocations
% Not all targets support position-independent code using a global offset table.
% Use a different way to access symbols in a position-indepent way in these cases.
asmr_w_global_access_without_got=07119_W_Exported/global symbols should be accessed via the GOT
% Global symbols (symbols from the unit interface, or defined in a program
% or library) should be accessed via the GOT when generating position-indepent code.
asmr_w_check_mem_operand_size=07120_W_Check size of memory operand "$1"
% The size of memory operand is possible invalid. This is
% probably an error in the assembler statement
asmr_w_check_mem_operand_size3=07121_W_Check size of memory operand "$1: memory-operand-size is $2 bits, but expected [$3 bits]"
% The size of memory operand is possible invalid. This is
% probably an error in the assembler statement
asmr_w_check_mem_operand_size_offset=07122_W_Check size of memory operand "$1: memory-operand-size is $2 bits, but expected [$3 bits + $4 byte offset]"
% The size of memory operand is possible invalid. This is
% probably an error in the assembler statement
asmr_w_check_mem_operand_negative_offset=07123_W_Check "$1: offset of memory operand is negative "$2 byte"
% The offset of memory operand is possible invalid. This is
% probably an error in the assembler statement
asmr_w_check_mem_operand_automap_multiple_size=07124_W_Check "$1: size of memory operand is empty, but es exists different definitions of the memory size =>> map to $2 (smallest option)"
% The size of memory operand is empty and we have different definitions of possible memory sizes. Check it!
asmr_e_invalid_ref_register=07125_E_Invalid register used in memory reference expression: "$1"
% FPU, vector and sometimes integer registers cannot be used in memory reference
% expressions, due to limitations of the cpu architecture or simple because
% it is not meaningful.
#
# Assembler/binary writers
#
# 08029 is the last used one
#
asmw_f_too_many_asm_files=08000_F_Trop peu de fichiers assembleur
% With smartlinking enabled, there are too many assembler
% files generated. Disable smartlinking.
asmw_f_assembler_output_not_supported=08001_F_Résultat de l'assembleur sélectionné non supporté
asmw_f_comp_not_supported=08002_F_Comp non supporté
asmw_f_direct_not_supported=08003_F_Direct non supporté pour les 'writers' binaires
% Direct assembler mode is not supported for binary writers.
asmw_e_alloc_data_only_in_bss=08004_E_Allocation de données supportée uniquement dans la section bss
asmw_f_no_binary_writer_selected=08005_F_Aucun 'writer' binaire sélectionné
asmw_e_opcode_not_in_table=08006_E_Asm: Code opération $1 absent de la liste
asmw_e_invalid_opcode_and_operands=08007_E_Asm: $1 combinaison du code opération et des paramètres incorrecte
asmw_e_16bit_not_supported=08008_E_Asm: référence 16 bits non supportée
asmw_e_invalid_effective_address=08009_E_Asm: Adresse effective incorrecte
asmw_e_immediate_or_reference_expected=08010_E_Asm: Immediate ou référence attendue
asmw_e_value_exceeds_bounds=08011_E_Asm: la valeur $1 dépasse les limites $2
asmw_e_short_jmp_out_of_range=08012_E_Asm: Saut court hors limites $1
asmw_e_undefined_label=08013_E_Asm: Label $1 non défini
asmw_e_comp_not_supported=08014_E_Asm: type Comp non supporté pour cette cible
asmw_e_extended_not_supported=08015_E_Asm: type Extended non supporté pour cette cible
asmw_e_duplicate_label=08016_E_Asm: label $1 dupliqué
asmw_e_redefined_label=08017_E_Asm: label $1 redéfini
asmw_e_first_defined_label=08018_E_Asm: Première définition
asmw_e_invalid_register=08019_E_Asm: Registre $1 incorrect
asmw_e_16bit_32bit_not_supported=08020_E_Asm: références 16 et 32 bits non supportées
asmw_e_64bit_not_supported=08021_E_Asm: paramètres 64 bits non supportés
#
# Executing linker/assembler
#
# 09034 is the last used one
#
# BeginOfTeX
%
% \section{Errors of assembling/linking stage}
% This section lists errors that occur when the compiler is processing the
% command line or handling the configuration files.
% \begin{description}
asmw_e_bad_reg_with_rex=08022_E_Asm: AH,BH,CH or DH cannot be used in an instruction requiring REX prefix
% x86_64 only: instruction encoding of this platform does not allow using
% 8086 high byte registers (AH,BH,CH or DH) together with REX prefix in a single instruction.
% The REX prefix is required whenever the instruction operand size is 64 bits, or
% when it uses one of extended x86_64 registers (R8-R15 or XMM8-XMM15).
asmw_e_missing_endprologue=08023_E_Missing .seh_endprologue directive
% x86_64-win64 only: Normally, SEH directives are handled internally by compiler.
% However, in pure assembler procedures .seh_endprologue directive is required
% if other SEH directives are present.
asmw_e_prologue_too_large=08024_E_Function prologue exceeds 255 bytes
% x86_64-win64: .seh_prologue directive must be placed within 255 bytes from function start.
asmw_e_handlerdata_no_handler=08025_E_.seh_handlerdata directive without preceding .seh_handler
% x86_64-win64: If .seh_handlerdata directive is used, then a .seh_handler directive must be
% present earlier in the same function.
asmw_f_too_many_relocations=08026_F_Relocation count for section $1 exceeds 65535
% Legacy COFF targets limit number of relocations per section to 65535 because they use a 2-byte field
% to store the relocation count. Targets using newer PECOFF format do not have this limitation.
asmw_w_changing_bind_type=08027_N_Change of bind type of symbol $1 from $2 to $3 after use
asmw_h_changing_bind_type=08028_H_Change of bind type of symbol $1 from $2 to $3 after use
% An assembler symbol bind type has been altered after use, which can lead to wrong code.
% First version is reserved for changig to local label, which is the most probable cause
% of wrong code generation, but currently set to Note level as it appears inside
% the compiler compilation.
asmw_e_32bit_not_supported=08029_E_Asm: 32 Bit references not supported
#
# Executing linker/assembler
#
# 09035 is the last used one
#
# BeginOfTeX
%
% \section{Errors of assembling/linking stage}
% This section lists errors that occur when the compiler is processing the
% command line or handling the configuration files.
% \begin{description}
exec_w_source_os_redefined=09000_W_Système d'exploitation source redéfini
% The source operating system is redefined.
exec_i_assembling_pipe=09001_I_Assemblage (pipe) de $1
% Assembling using a pipe to an external assembler.
exec_d_cant_create_asmfile=09002_E_Impossible de créer le fichier assembleur: $1
% The mentioned file can't be created. Check if you have got
% access permissions to create this file
exec_e_cant_create_objectfile=09003_E_Impossible de créer le fichier object: $1
% The mentioned file can't be created. Check if you've
% got access permissions to create this file
exec_e_cant_create_archivefile=09004_E_Impossible de créer le fichier archive: $1
% The mentioned file can't be created. Check if you've
% access permissions to create this file
exec_e_assembler_not_found=09005_E_Assembleur $1 non trouvé, utilisation d'un assembleur externe
% The assembler program was not found. The compiler will produce a script that
% can be used to assemble and link the program.
exec_t_using_assembler=09006_T_Utilisation de l'assembleur: $1
% Information message saying which assembler is being used.
exec_e_error_while_assembling=09007_E_Erreur durant l'assemblage, code de sortie $1
% There was an error while assembling the file using an external assembler.
% Consult the documentation of the assembler tool to find out more information
% on this error.
exec_e_cant_call_assembler=09008_E_Impossible d'appeler l'assembleur, erreur $1, utilisation d'un assembleur externe
% An error occurred when calling an external assembler, The compiler will produce a script that
% can be used to assemble and link the program.
exec_i_assembling=09009_I_Assemblage de $1
% An informational message stating which file is being assembled.
exec_i_assembling_smart=09010_I_Assemblage avec édition intelligente des liens de $1
% An informational message stating which file is being assembled using smartlinking.
exec_w_objfile_not_found=09011_W_Objet $1 non trouvé, l'édition des liens peut échouer !
% One of the object file is missing, and linking will probably fail.
% Check your paths.
exec_w_libfile_not_found=09012_W_Bibliothèque $1 non trouvée, l'édition des liens peut échouer !
% One of the library file is missing, and linking will probably fail.
% Check your paths.
exec_e_error_while_linking=09013_E_Erreur durant l'édition des liens
% Generic error while linking.
exec_e_cant_call_linker=09014_E_Impossible d'appeler l'éditeur de liens, utilisation d'un éditeur de liens externe
% An error occurred when calling an external linker, The compiler will produce a script that
% can be used to assemble and link the program.
exec_i_linking=09015_I_Édition des liens de $1
% An informational message, showing which program or library is being linked.
exec_e_util_not_found=09016_E_Utilitaire $1 non trouvé, utilisation d'un éditeur de liens externe
% An external tool was not found, the compiler will produce a script that
% can be used to assemble and link or postprocess the program.
exec_t_using_util=09017_T_Utilisation de l'utilitaire $1
% An informational message, showing which external program (usually a postprocessor) is being used.
exec_e_exe_not_supported=09018_E_Création d'exécutables non supportée
% Creating executable programs is not supported for this platform, because it was
% not yet implemented in the compiler.
exec_e_dll_not_supported=09019_E_Création de bibliothèques dynamiques/partagées non supportée
% Creating dynamically loadable libraries is not supported for this platform, because it was
% not yet implemented in the compiler.
exec_e_static_lib_not_supported=09035_E_Creation of Static Libraries not supported
% Creating static libraries is not supported for this platform, because it was
% not yet implemented in the compiler.
exec_i_closing_script=09020_I_Fermeture du script $1
% Informational message showing when the external assembling an linking script is finished.
exec_e_res_not_found=09021_E_Compilateur de ressource non trouvé, utilisation d'un compilateur externe
% An external resource compiler was not found, the compiler will produce a script that
% can be used to assemble, compile resources and link or postprocess the program.
exec_i_compilingresource=09022_I_Compilation de la resource $1
% An informational message, showing which resource is being compiled.
exec_t_unit_not_static_linkable_switch_to_smart=09023_T_Édition statique des liens de l'unité $1 impossible, utilisation d'une édition intelligente des liens
% Statical linking was requested, but a unit which is not statically linkable was used.
exec_t_unit_not_smart_linkable_switch_to_static=09024_T_Édition intelligente des liens de l'unité $1 impossible, utilisation d'une édition de liens statique
% Smart linking was requested, but a unit which is not smart-linkable was used.
exec_t_unit_not_shared_linkable_switch_to_static=09025_T_Édition des liens partagée de l'unité $1 impossible, utilisation d'une édition de liens statique
% Shared linking was requested, but a unit which is not shared-linkable was used.
exec_e_unit_not_smart_or_static_linkable=09026_E_Édition intelligente ou statique des liens de l'unité $1 impossible
% Smart or static linking was requested, but a unit which cannot be used for either was used.
exec_e_unit_not_shared_or_static_linkable=09027_E_Édition des liens partagée ou statique de l'unité $1 impossible
% Shared or static linking was requested, but a unit which cannot be used for either was used.
exec_d_resbin_params=09028_D_Exécution du compilateur de ressource "$1" avec "$2" comme ligne de commande
% An informational message showing which command-line is used for the resource compiler.
%\end{description}
# EndOfTeX
#
# Executable information
#
# BeginOfTeX
% \section{Executable information messages.}
% This section lists all messages that the compiler emits when an executable program is produced,
% and only when the internal linker is used.
% \begin{description}
exec_e_error_while_compiling_resources=09029_E_Error while compiling resources
% The resource compiler or converter returned an error.
exec_e_cant_call_resource_compiler=09030_E_Can't call the resource compiler "$1", switching to external mode
% An error occurred when calling a resource compiler. The compiler will produce
% a script that can be used to assemble, compile resources and link or
% postprocess the program.
exec_e_cant_open_resource_file=09031_E_Can't open resource file "$1"
% An error occurred resource file cannot be opened.
exec_e_cant_write_resource_file=09032_E_Can't write resource file "$1"
% An error occurred resource file cannot be written.
exec_n_backquote_cat_file_not_found=09033_N_File "$1" not found for backquoted cat command
% The compiler did not find the file that should be expanded into linker parameters
exec_w_init_file_not_found=09034_W_"$1" not found, this will probably cause a linking failure
% The compiler adds certain startup code files to the linker only when they are found.
% If they are not found, they are not added and this might cause a linking failure.
%
%\end{description}
# EndOfTeX
#
# Executable information
#
# 09134 is the last used one
#
# BeginOfTeX
% \section{Executable information messages.}
% This section lists all messages that the compiler emits when an executable program is produced,
% and only when the internal linker is used.
% \begin{description}
execinfo_f_cant_process_executable=09128_F_Post-traitement de l'exécutable $1 impossible
% Fatal error when the compiler is unable to post-process an executable.
execinfo_f_cant_open_executable=09129_F_Impossible d'ouvrir l'exécutable $1
% Fatal error when the compiler cannot open the file for the executable.
execinfo_x_codesize=09130_X_Taille du code: $1 octets
% Informational message showing the size of the produced code section.
execinfo_x_initdatasize=09131_X_Taille des données initialisées: $1 octets
% Informational message showing the size of the initialized data section.
execinfo_x_uninitdatasize=09132_X_Taille des données non-initialisées: $1 octets
% Informational message showing the size of the uninitialized data section.
execinfo_x_stackreserve=09133_X_Taille de pile réservée: $1 octets
% Informational message showing the stack size that the compiler reserved for the executable.
execinfo_x_stackcommit=09134_X_Taille de pile validée: $1 octets
% Informational message showing the stack size that the compiler committed for the executable.
%\end{description}
# EndOfTeX
#
# Unit loading
#
# 10041 is the last used one
#
# BeginOfTeX
% \section{Unit loading messages.}
% This section lists all messages that can occur when the compiler is
% loading a unit from disk into memory. Many of these messages are
% informational messages.
% \begin{description}
link_f_executable_too_big=09200_F_Executable image size is too big for $1 target.
% Fatal error when resulting executable is too big.
link_w_32bit_absolute_reloc=09201_W_Object file "$1" contains 32-bit absolute relocation to symbol "$2".
% Warning when 64-bit object file contains 32-bit absolute relocations.
% In such case an executable image can be loaded into lower 4Gb of
% address space only.
%\end{description}
# EndOfTeX
#
# Unit loading
#
# 10062 is the last used one
#
# BeginOfTeX
% \section{Unit loading messages.}
% This section lists all messages that can occur when the compiler is
% loading a unit from disk into memory. Many of these messages are
% informational messages.
% \begin{description}
unit_t_unitsearch=10000_T_Recherche de l'unité $1
% When you use the \var{-vt}, the compiler tells you where it tries to find
% unit files.
unit_t_ppu_loading=10001_T_Chargement du fichier PPU $1
% When the \var{-vt} switch is used, the compiler tells you
% what units it loads.
unit_u_ppu_name=10002_U_Fichier PPU: $1
% When you use the \var{-vu} flag, the unit name is shown.
unit_u_ppu_flags=10003_U_Drapeaux PPU: $1
% When you use the \var{-vu} flag, the unit flags are shown.
unit_u_ppu_crc=10004_U_Somme de contrôle du fichier PPU: $1
% When you use the \var{-vu} flag, the unit CRC check is shown.
unit_u_ppu_time=10005_U_Fichier PPU compilé à $1
% When you use the \var{-vu} flag, the time the unit was compiled is shown.
unit_u_ppu_file_too_short=10006_U_Fichier PPU trop court
% The ppufile is too short, not all declarations are present.
unit_u_ppu_invalid_header=10007_U_En-tête PPU invalide (PPU non trouvé au début)
% A unit file contains as the first three bytes the ascii codes of \var{PPU}
unit_u_ppu_invalid_version=10008_U_Version $1 de fichier PPU invalide
% This unit file was compiled with a different version of the compiler, and
% cannot be read.
unit_u_ppu_invalid_processor=10009_U_Fichier PPU compilé pour un autre processeur
% This unit file was compiled for a different processor type, and
% cannot be read
unit_u_ppu_invalid_target=10010_U_Fichier PPU compilé pour une autre cible
% This unit file was compiled for a different target, and
% cannot be read
unit_u_ppu_source=10011_U_Fichier source: $1
% When you use the \var{-vu} flag, the unit source file name is shown.
unit_u_ppu_write=10012_U_Écriture de $1
% When you specify the \var{-vu} switch, the compiler will tell you where it
% writes the unit file.
unit_f_ppu_cannot_write=10013_F_Impossible d'écrire le fichier PPU
% An error occurred when writing the unit file.
unit_f_ppu_read_error=10014_F_Erreur lors de la lecture du fichier PPU
% This means that the unit file was corrupted, and contains invalid
% information. Recompilation will be necessary.
unit_f_ppu_read_unexpected_end=10015_F_Fin de fichier PPU inattendue
% Unexpected end of file. This may mean that the PPU file is
% corrupted.
unit_f_ppu_invalid_entry=10016_F_Entrée invalide dans le fichier PPU $1
% The unit the compiler is trying to read is corrupted, or generated with a
% newer version of the compiler.
unit_f_ppu_dbx_count_problem=10017_F_PPU Dbx count problem
% There is an inconsistency in the debugging information of the unit.
unit_e_illegal_unit_name=10018_E_Nom d'unité illégal: $1
% The name of the unit does not match the file name.
unit_f_too_much_units=10019_F_Trop d'unités
% \fpc has a limit of 1024 units in a program. You can change this behavior
% by changing the \var{maxunits} constant in the \file{fmodule.pas} file of the
% compiler, and recompiling the compiler.
unit_f_circular_unit_reference=10020_F_Référence circulaire entre les unités $1 et $2
% Two units are using each other in the interface part. This is only allowed
% in the \var{implementation} part. At least one unit must contain the other one
% in the \var{implementation} section.
unit_f_cant_compile_unit=10021_F_Compilation de l'unité $1 impossible, pas de sources disponibles
% A unit was found that needs to be recompiled, but no sources are
% available.
unit_f_cant_find_ppu=10022_F_Impossible de trouver l'unité $1
% You tried to use a unit of which the PPU file isn't found by the
% compiler. Check your configuration file for the unit paths
unit_w_unit_name_error=10023_W_Unité $1 non trouvée mais $2 existe
% This error message is no longer used.
unit_f_unit_name_error=10024_F_Unité $1 cherchée mais $2 trouvée
% Dos truncation of 8 letters for unit PPU files
% may lead to problems when unit name is longer than 8 letters.
unit_w_switch_us_missed=10025_W_La compilation de l´unité System requiert l´option -Us
% When recompiling the system unit (it needs special treatment), the
% \var{-Us} must be specified.
unit_f_errors_in_unit=10026_F_$1 erreurs lors de la compilation du module, arrêt
% When the compiler encounters a fatal error or too many errors in a module
% then it stops with this message.
unit_u_load_unit=10027_U_Chargement à partir de $1 ($2) de l'unité $3
% When you use the \var{-vu} flag, which unit is loaded from which unit is
% shown.
unit_u_recompile_crc_change=10028_U_Recompilation de $1, la somme de contrôle est maintenant $2
% The unit is recompiled because the checksum of a unit it depends on has
% changed.
unit_u_recompile_source_found_alone=10029_U_Recompilation de $1, seul le source a été trouvé
% When you use the \var{-vu} flag, these messages tell you why the current
% unit is recompiled.
unit_u_recompile_staticlib_is_older=10030_U_Recompilation de l'unité, la bibliothèque statique est plus ancienne que le fichier PPU
% When you use the \var{-vu} flag, the compiler warns if the static library
% of the unit are older than the unit file itself.
unit_u_recompile_sharedlib_is_older=10031_U_Recompilation de l'unité, la bibliothèque partagée est plus ancienne que le fichier PPU
% When you use the \var{-vu} flag, the compiler warns if the shared library
% of the unit are older than the unit file itself.
unit_u_recompile_obj_and_asm_older=10032_U_Recompilation de l'unité, les fichiers OBJ et ASM sont plus anciens que le fichier PPU
% When you use the \var{-vu} flag, the compiler warns if the assembler or
% object file of the unit are older than the unit file itself.
unit_u_recompile_obj_older_than_asm=10033_U_Recompilation de l'unité, le fichier OBJ est plus ancien que le fichier ASM
% When you use the \var{-vu} flag, the compiler warns if the assembler
% file of the unit is older than the object file of the unit.
unit_u_parsing_interface=10034_U_Analyse de l'interface de $1
% When you use the \var{-vu} flag, the compiler warns that it starts
% parsing the interface part of the unit
unit_u_parsing_implementation=10035_U_Analyse de l'implémentation de $1
% When you use the \var{-vu} flag, the compiler warns that it starts
% parsing the implementation part of the unit
unit_u_second_load_unit=10036_U_Deuxième compilation de l'unité $1
% When you use the \var{-vu} flag, the compiler warns that it starts
% recompiling a unit for the second time. This can happend with interdepend
% units.
unit_u_check_time=10037_U_Vérification du fichier PPU $1, date/heure $2
% When you use the \var{-vu} flag, the compiler show the filename and
% date and time of the file which a recompile depends on
### The following two error msgs are currently disabled.
#unit_h_cond_not_set_in_last_compile=10038_H_Conditional $1 was not set at startup in last compilation of $2
#% when recompilation of an unit is required the compiler will check that
#% the same conditionals are set for the recompiliation. The compiler has
#% found a conditional that currently is defined, but was not used the last
#% time the unit was compiled.
#unit_h_cond_set_in_last_compile=10039_H_Conditional $1 was set at startup in last compilation of $2
#% when recompilation of an unit is required the compiler will check that
#% the same conditionals are set for the recompiliation. The compiler has
#% found a conditional that was used the last time the unit was compiled, but
#% the conditional is currently not defined.
unit_w_cant_compile_unit_with_changed_incfile=10040_W_Impossible de recompiler l'unité $1 alors que des fichiers inclus ont été trouvés
% A unit was found to have modified include files, but
% some source files were not found, so recompilation is impossible.
unit_u_source_modified=10041_U_File $1 is newer than the one used for creating PPU file $2
% A modified source file for a compiler unit was found.
unit_u_ppu_invalid_fpumode=10042_U_Utilisation d'une unité compilée avec un mode FPU incorrect
% Trying to compile code while using units which were not compiled with
% the same floating point format mode. Either all code should be compiled
% with FPU emulation on, or with FPU emulation off.
unit_u_loading_interface_units=10043_U_Chargement des unités déclarées dans l'interface de $1
% When you use the \var{-vu} flag, the compiler warns that it starts
% loading the units defined in the interface part of the unit.
unit_u_loading_implementation_units=10044_U_Chargement des unités déclarées dans l'implementation de $1
% When you use the \var{-vu} flag, the compiler warns that it starts
% loading the units defined in the implementation part of the unit.
unit_u_interface_crc_changed=10045_U_La somme de contrôle de l'interface de l'unité $1 a changé
% When you use the \var{-vu} flag, the compiler warns that it the
% CRC calculated for the interface has been changed after the implementation
% has been parsed.
unit_u_implementation_crc_changed=10046_U_La somme de contrôle de l'implémentation de l'unité $1 a changé
% When you use the \var{-vu} flag, the compiler warns that it the
% CRC calculated has been changed after the implementation
% has been parsed.
unit_u_finished_compiling=10047_U_Recompilation de l'unité $1 terminée
% When you use the \var{-vu} flag, the compiler warns that it
% has finished compiling the unit.
unit_u_add_depend_to=10048_U_Ajout d'une dépendance entre $1 et $2
% When you use the \var{-vu} flag, the compiler warns that it
% has added a dependency between the two units.
unit_u_no_reload_is_caller=10049_U_Pas de rechargement de $1 qui est l'unité appelante
% When you use the \var{-vu} flag, the compiler warns that it
% has will not reload the unit because it is the unit that wants
% to load this unit
unit_u_no_reload_in_second_compile=10050_U_Pas de rechargement de $1 déjà en cours de recompilation
% When you use the \var{-vu} flag, the compiler warns that it
% has will not reload the unit because it is already in a second recompile
unit_u_flag_for_reload=10051_U_Nécessité de recharger $1
% When you use the \var{-vu} flag, the compiler warns that it
% has to reload the unit
unit_u_forced_reload=10052_U_Rechargement forcé
% When you use the \var{-vu} flag, the compiler warns that it
% has is reloading the unit because it was required
unit_u_previous_state=10053_U_État précédent de l'unité $1 : $2
% When you use the \var{-vu} flag, the compiler shows the
% previous state of the unit
unit_u_second_compile_unit=10054_U_Recompilation de l'unité $1
% When you use the \var{-vu} flag, the compiler warns that it starts
% recompiling a unit for the second time. This can happend with interdepend
% units.
unit_u_loading_unit=10055_U_Chargement de l'unité $1
% When you use the \var{-vu} flag, the compiler warns that it starts
% loading the unit.
unit_u_finished_loading_unit=10056_U_Chargement de l'unité $1 terminé
% When you use the \var{-vu} flag, the compiler warns that it finished
% loading the unit.
unit_u_registering_new_unit=10057_U_Enregistrement de la nouvelle unité $1
% When you use the \var{-vu} flag, the compiler warns that it has
% found a new unit and registers it in the internal lists.
unit_u_reresolving_unit=10058_U_Re-résolution de l'unité $1
% When you use the \var{-vu} flag, the compiler warns that it
% has to recalculate the internal data of the unit
unit_u_skipping_reresolving_unit=10059_U_Saut de la re-resolution de l'unité $1, chargement des unités utilisées
% When you use the \var{-vu} flag, the compiler warns that it
% skips to recalculate the internal data of the unit because there
% is no data to recalculate
% \end{description}
# EndOfTeX
#
# Options
#
# 11039 is the last used one
#
unit_u_unload_resunit=10060_U_Unloading resource unit $1 (not needed)
% When you use the \var{-vu} flag, the compiler warns that it is unloading the
% resource handling unit, since no resources are used.
unit_e_different_wpo_file=10061_E_Unit $1 was compiled using a different whole program optimization feedback input ($2, $3); recompile it without wpo or use the same wpo feedback input file for this compilation invocation
% When a unit has been compiled using a particular whole program optimization (wpo) feedback file (\var{-FW<x>} \var{-OW<x>}),
% this compiled version of the unit is specialised for that particular compilation scenario and cannot be used in
% any other context. It has to be recompiled before you can use it in another program or with another wpo feedback input file.
unit_u_indirect_crc_changed=10062_U_Indirect interface (objects/classes) CRC changed for unit $1
% When you use the \var{-vu} flag, the compiler warns that the
% indirect CRC calculated for the unit (this is the CRC of all classes/objects/interfaces/$\ldots$
% in the interfaces of units directly or indirectly used by this unit in the interface) has been changed after the
% implementation has been parsed.
unit_u_ppu_invalid_memory_model=10063_U_PPU is compiled for another i8086 memory model
% This unit file was compiled for a different i8086 memory model and
% cannot be read.
% \end{description}
# EndOfTeX
#
# Options
#
# 11057 is the last used one
#
option_usage=11000_O_$1 [options] <nom_fichier> [options]
# BeginOfTeX
%
% \section{Command-line handling errors}
% This section lists errors that occur when the compiler is processing the
% command line or handling the configuration files.
% \begin{description}
option_only_one_source_support=11001_W_Un seul fichier source supporté
% You can specify only one source file on the command line. The first
% one will be compiled, others will be ignored. This may indicate that
% you forgot a \var{'-'} sign.
option_def_only_for_os2=11002_W_Les fichiers DEF ne peuvent être créés que pour OS/2
% This option can only be specified when you're compiling for OS/2
option_no_nested_response_file=11003_E_Les fichiers de réponse imbriqués ne sont pas supportés
% you cannot nest response files with the \var{@file} command-line option.
option_no_source_found=11004_F_Pas de nom de fichier source sur la ligne de commande
% The compiler expects a source file name on the command line.
option_no_option_found=11005_N_Aucune option trouvée dans le fichier de configuration $1
% The compiler didn't find any option in that config file.
option_illegal_para=11006_E_Paramètre illégal: $1
% You specified an unknown option.
option_help_pages_para=11007_H_-? génère les pages d'aide
% When an unknown option is given, this message is diplayed.
option_too_many_cfg_files=11008_F_Trop de fichiers de configuration imbriqués
% You can only nest up to 16 config files.
option_unable_open_file=11009_F_Ouverture du fichier $1 impossible
% The option file cannot be found.
option_reading_further_from=11010_D_Lecture d'options supplémentaires depuis $1
% Displayed when you have notes turned on, and the compiler switches
% to another options file.
option_target_is_already_set=11011_W_La destination est déjà définie à: $1
% Displayed if more than one \var{-T} option is specified.
option_no_shared_lib_under_dos=11012_W_Bibliothèques partagées non supportées sous DOS, retour à une édition de liens statique
% If you specify \var{-CD} for the \dos platform, this message is displayed.
% The compiler supports only static libraries under \dos
option_too_many_ifdef=11013_F_Trop de IF(N)DEF
% the \var{\#IF(N)DEF} statements in the options file are not balanced with
% the \var{\#ENDIF} statements.
option_too_many_endif=11014_F_Trop de ENDIF
% the \var{\#IF(N)DEF} statements in the options file are not balanced with
% the \var{\#ENDIF} statements.
option_too_less_endif=11015_F_Directive de compilation conditionnelle non fermée à la fin du fichier
% the \var{\#IF(N)DEF} statements in the options file are not balanced with
% the \var{\#ENDIF} statements.
option_no_debug_support=11016_W_La génération d'informations de débogage n'est pas supportée par cet exécutable
% It is possible to have a compiler executable that doesn't support
% the generation of debugging info. If you use such an executable with the
% \var{-g} switch, this warning will be displayed.
option_no_debug_support_recompile_fpc=11017_H_Essayez de recompiler avec -dGDB
% It is possible to have a compiler executable that doesn't support
% the generation of debugging info. If you use such an executable with the
% \var{-g} switch, this warning will be displayed.
option_obsolete_switch=11018_W_Vous utilisez le commutateur obsolète $1
% this warns you when you use a switch that is not needed/supported anymore.
% It is recommended that you remove the switch to overcome problems in the
% future, when the switch meaning may change.
option_obsolete_switch_use_new=11019_W_Vous utilisez le commutateur obsolète $1, veuillez utiliser $2
% this warns you when you use a switch that is not supported anymore. You
% must now use the second switch instead.
% It is recommended that you change the switch to overcome problems in the
% future, when the switch meaning may change.
option_switch_bin_to_src_assembler=11020_N_Switching assembler to default source writing assembler
% this notifies you that the assembler has been changed because you used the
% -a switch which can't be used with a binary assembler writer.
option_incompatible_asm=11021_W_La sortie assembleur "$1" n'est pas compatible avec "$2"
option_asm_forced=11022_W_Utilisation de l'assembleur "$1" forcée
% The assembler output selected can not generate
% object files with the correct format. Therefore, the
% default assembler for this target is used instead.
option_using_file=11026_T_Lecture des options depuis le fichier $1
% Options are also read from this file
option_using_env=11027_T_Lecture des options depuis la variable d'environnement $1
% Options are also read from this environment string
option_handling_option=11028_D_Utilisation de l'option "$1"
% Debug info that an option is found and will be handled
option_help_press_enter=11029__*** Appuyez sur Entrée ***
% Message shown when help is shown page per page. When pressing the ENTER
% Key, the next page of help is shown. If you press q and then ENTER, the
% compiler exits.
option_start_reading_configfile=11030_H_Début de la lecture du fichier de configuration $1
% Starting of config file parsing.
option_end_reading_configfile=11031_H_Fin de la lecture du fichier de configuration $1
% End of config file parsing.
option_interpreting_option=11032_D_Interprétation de l'option "$1"
% The compiler is interpreting an option
option_interpreting_firstpass_option=11036_D_Interprétation de l'option de 1ère passe "$1"
% The compiler is interpreting an option for the first time.
option_interpreting_file_option=11033_D_Interprétation de l'option de fichier "$1"
% The compiler is interpreting an option which it read from the configuration file.
option_read_config_file=11034_D_Lecture du fichier de configuration "$1"
% The compiler is starting to read the configuration file.
option_found_file=11035_D_Fichier source "$1" trouvé
% Additional infos about options, displayed
% when you have debug option turned on.
option_code_page_not_available=11039_E_Page de codes inconnue
% An unknown codepage for the source files was requested.
% The compiler is compiled with support for several codepages built-in.
% The requested codepage is not in that list. You will need to recompile
% the compiler with support for the codepage you need.
option_config_is_dir=11040_F_Le fichier de configuration $1 est un répertoire
% Directories can not be used as configuration files.
%\end{description}
# EndOfTeX
#
# Logo (option -l)
#
option_confict_asm_debug=11041_W_Assembler output selected "$1" cannot generate debug info, debugging disabled
% The selected assembler output cannot generate
% debugging information, debugging option is therefore disabled.
option_ppc386_deprecated=11042_W_Use of ppc386.cfg is deprecated, please use fpc.cfg instead
% Using ppc386.cfg is still supported for historical reasons, however, for a multiplatform
% system the naming makes no sense anymore. Please continue to use fpc.cfg instead.
option_else_without_if=11043_F_In options file $1 at line $2 #ELSE directive without #IF(N)DEF found
% An \var{\#ELSE} statement was found in the options file without a matching \var{\#IF(N)DEF} statement.
option_unsupported_target=11044_F_Option "$1" is not, or not yet, supported on the current target platform
% Not all options are supported or implemented for all target platforms. This message informs you that a chosen
% option is incompatible with the currently selected target platform.
option_unsupported_target_for_feature=11045_F_The feature "$1" is not, or not yet, supported on the selected target platform
% Not all features are supported or implemented for all target platforms. This message informs you that a chosen
% feature is incompatible with the currently selected target platform.
option_dwarf_smart_linking=11046_N_DWARF debug information cannot be used with smart linking on this target, switching to static linking
% Smart linking is currently incompatible with DWARF debug information on most
% platforms, so smart linking is disabled in such cases.
option_ignored_target=11047_W_Option "$1" is ignored for the current target platform.
% Not all options are supported or implemented for all target platforms. This message informs you that a chosen
% option is ignored for the currently selected target platform.
option_debug_external_unsupported=11048_W_Disabling external debug information because it is unsupported for the selected target/debug format combination.
% Not all debug formats can be stored in an external file on all platforms. In particular, on
% Mac OS X only DWARF debug information can be stored externally.
option_dwarf_smartlink_creation=11049_N_DWARF debug information cannot be used with smart linking with external assembler, disabling static library creation.
% Smart linking is currently incompatble with DWARF debug information on most
% platforms, so smart linking is disabled in such cases.
option_invalid_macosx_deployment_target=11050_E_Invalid value for MACOSX_DEPLOYMENT_TARGET environment variable: $1
option_invalid_iphoneos_deployment_target=11051_E_Invalid value for IPHONEOS_DEPLOYMENT_TARGET environment variable: $1
% On Mac OS X, the MACOSX\_DEPLOYMENT\_TARGET/IPHONEOS\_DEPLOYMENT\_TARGET environment variable can be
% used to set the default target OS version. In case of Mac OS X, it has to be of the format
% XY.Z or XY.Z.AB with X, Y,Z , A and B all digits from 0-9.
% In case of iOS, it has to be X.Z.A, where X, Z and A can all be either 1 or 2
% digits from 0-9.
option_illegal_fpu_eabihf=11052_E_You must use one of the VFP FPU types when using the EABIHF ABI target
% The EABIHF (VFP hardfloat) ABI target can only be used with VFP FPUs.
option_w_unsupported_debug_format=11053_W_The selected debug format is not supported on the current target, not changing the current setting
% Not all targets support all debug formats (in particular, Stabs is not supported on 64 bit targets).
option_missing_arg=11054_E_argument to "$1" is missing
% Displayed when parameter must be followed by an argument.
option_malformed_para=11055_E_malformed parameter: $1
% Given argument is not valid for parameter.
option_smart_link_requires_external_linker=11056_W_Smart linking requires external linker
option_com_files_require_tiny_model=11057_E_Creating .COM files is not supported in the current memory model. Only the tiny memory model supports making .COM files.
%\end{description}
# EndOfTeX
#
# Whole program optimization
#
# 12019 is the last used one
#
# BeginOfTeX
%
% \section{Whole program optimization messages}
% This section lists errors that occur when the compiler is performing
% whole program optimization.
% \begin{description}
wpo_cant_find_file=12000_F_Cannot open whole program optimization feedback file "$1"
% The compiler cannot open the specified feedback file with whole program optimization information.
wpo_begin_processing=12001_D_Processing whole program optimization information in wpo feedback file "$1"
% The compiler starts processing whole program optimization information found in the named file.
wpo_end_processing=12002_D_Finished processing the whole program optimization information in wpo feedback file "$1"
% The compiler has finished processing the whole program optimization information found in the named file.
wpo_expected_section=12003_E_Expected section header, but got "$2" at line $1 of wpo feedback file
% The compiler expected a section header in the whole program optimization file (starting with \%),
% but did not find it.
wpo_no_section_handler=12004_W_No handler registered for whole program optimization section "$2" at line $1 of wpo feedback file, ignoring
% The compiler has no handler to deal with the mentioned whole program optimization information
% section, and will therefore ignore it and skip to the next section.
wpo_found_section=12005_D_Found whole program optimization section "$1" with information about "$2"
% The compiler encountered a section with whole program optimization information, and according
% to its handler this section contains information usable for the mentioned purpose.
wpo_no_input_specified=12006_F_The selected whole program optimizations require a previously generated feedback file (use -Fw to specify)
% The compiler needs information gathered during a previous compilation run to perform the selected
% whole program optimizations. You can specify the location of the feedback file containing this
% information using the -Fw switch.
wpo_not_enough_info=12007_E_No collected information necessary to perform "$1" whole program optimization found
% While you pointed the compiler to a file containing whole program optimization feedback, it
% did not contain the information necessary to perform the selected optimizations. You most likely
% have to recompile the program using the appropriate -OWxxx switch.
wpo_no_output_specified=12008_F_Specify a whole program optimization feedback file to store the generated info in (using -FW)
% You have to specify the feedback file in which the compiler has to store the whole program optimization
% feedback that is generated during the compilation run. This can be done using the -FW switch.
wpo_output_without_info_gen=12009_E_Not generating any whole program optimization information, yet a feedback file was specified (using -FW)
% The compiler was instructed to store whole program optimization feedback into a file specified using -FW,
% but not to actually generated any whole program optimization feedback. The classes of to be
% generated information can be specified using -OWxxx.
wpo_input_without_info_use=12010_E_Not performing any whole program optimizations, yet an input feedback file was specified (using -Fw)
% The compiler was not instructed to perform any whole program optimizations (no -Owxxx parameters),
% but nevertheless an input file with such feedback was specified (using -Fwyyy). Since this can
% indicate that you forgot to specify an -Owxxx parameter, the compiler generates an error in this case.
wpo_skipping_unnecessary_section=12011_D_Skipping whole program optimization section "$1", because not needed by the requested optimizations
% The whole program optimization feedback file contains a section with information that is not
% required by the selected whole program optimizations.
wpo_duplicate_wpotype=12012_W_Overriding previously read information for "$1" from feedback input file using information in section "$2"
% The feedback file contains multiple sections that provide the same class of information (e.g.,
% information about which virtual methods can be devirtualized). In this case, the information in last encountered
% section is used. Turn on debugging output (-vd) to see which class of information is provided by each section.
wpo_cannot_extract_live_symbol_info_strip=12013_E_Cannot extract symbol liveness information from program when stripping symbols, use -Xs-
% Certain symbol liveness collectors extract the symbol information from the linked program. If the symbol information
% is stripped (option -Xs), this is not possible.
wpo_cannot_extract_live_symbol_info_no_link=12014_E_Cannot extract symbol liveness information from program when when not linking
% Certain symbol liveness collectors extract the symbol information from the linked program. If the program is not
% linked by the compiler, this is not possible.
wpo_cannot_find_symbol_progs=12015_F_Cannot find "$1" or "$2" to extract symbol liveness information from linked program
% Certain symbol liveness collectors need a helper program to extract the symbol information from the linked program.
% This helper program is normally 'nm', which is part of the GNU binutils.
wpo_error_reading_symbol_file=12016_E_Error during reading symbol liveness information produced by "$1"
% An error occurred during the reading of the symbol liveness file that was generated using the 'nm' or 'objdump' program. The reason
% can be that it was shorter than expected, or that its format was not understood.
wpo_error_executing_symbol_prog=12017_F_Error executing "$1" (exitcode: $2) to extract symbol information from linked program
% Certain symbol liveness collectors need a helper program to extract the symbol information from the linked program.
% The helper program produced the reported error code when it was run on the linked program.
wpo_symbol_live_info_needs_smart_linking=12018_E_Collection of symbol liveness information can only help when using smart linking, use -CX -XX
% Whether or not a symbol is live is determined by looking whether it exists in the final linked program.
% Without smart linking/dead code stripping, all symbols are always included, regardless of whether they are
% actually used or not. So in that case all symbols will be seen as live, which makes this optimization ineffective.
wpo_cant_create_feedback_file=12019_E_Cannot create specified whole program optimisation feedback file "$1"
% The compiler is unable to create the file specified using the -FW parameter to store the whole program optimisation information.
%\end{description}
# EndOfTeX
#
# Logo (option -l)
#
option_logo=11023_[ Compilateur Free Pascal version $FPCFULLVERSION [$FPCDATE] for $FPCCPU
Copyright (c) 1993-2025, Florian Klaempfl and others]
#
# Info (option -i)
#
option_info=11024_[ Compilateur Free Pascal version $FPCVERSION
Date du compilateur: $FPCDATE
Processeur cible: $FPCCPU
Cibles supportées: $OSTARGETS
Jeu d'instructions CPU supportés: $INSTRUCTIONSETS
Jeu d'instructions FPU supportés: $FPUINSTRUCTIONSETS
Optimisations supportées: $OPTIMIZATIONS
Ce programme est fourni sous la License Publique Générale GNU (GNU GPL).
Pour plus d'informations, consultez le fichier COPYING.v2.
Rapports de bogues, suggestions, etc. à:
https://bugs.freepascal.org
]
#
# Help pages (option -? and -h)
#
# The first character on the line indicates who will display this
# line, the current possibilities are :
# * = every target
# 3 = 80x86 targets
# 6 = 680x0 targets
# e = in extended debug mode only
# P = PowerPC targets
# S = Sparc targets
# V = Virtual machine targets
# The second character also indicates who will display this line,
# (if the above character was TRUE) the current possibilities are :
# * = everyone
# g = with GDB info supported by the compiler
# O = OS/2
# L = UNIX systems
# The third character represents the indentation level.
#
option_info=11024_[
Free Pascal Compiler version $FPCVERSION
Compiler date : $FPCDATE
Compiler CPU target: $FPCCPU
Supported targets (targets marked with '{*}' are under development):
$OSTARGETS
Supported CPU instruction sets:
$INSTRUCTIONSETS
Supported FPU instruction sets:
$FPUINSTRUCTIONSETS
Supported inline assembler modes:
$ASMMODES
Recognized compiler and RTL features:
$FEATURELIST
Supported ABI targets:
$ABITARGETS
Supported Optimizations:
$OPTIMIZATIONS
Supported Whole Program Optimizations:
All
$WPOPTIMIZATIONS
Supported Microcontroller types:$\n $CONTROLLERTYPES$\n
This program comes under the GNU General Public Licence
For more information read COPYING.v2
Please report bugs in our bug tracker on:
https://bugs.freepascal.org
More information may be found on our WWW pages (including directions
for mailing lists useful for asking questions or discussing potential
new features, etc.):
https://www.freepascal.org
]
#
# Help pages (option -? and -h)
#
# The first character on the line indicates who will display this
# line, the current possibilities are :
# * = every target
# 3 = 80x86 targets
# 4 = x86_64
# 6 = 680x0 targets
# 8 = 8086 (16-bit) targets
# a = AArch64
# A = ARM
# e = in extended debug mode only
# F = help for the 'fpc' binary (independent of the target compiler)
# I = VIS
# J = JVM
# M = MIPS (MIPSEB) targets
# m = MIPSEL targets
# P = PowerPC targets
# p = PowerPC64 targets
# S = Sparc targets
# V = AVR
# The second character also indicates who will display this line,
# (if the above character was TRUE) the current possibilities are :
# * = everyone
# g = with GDB info supported by the compiler
# O = OS/2
# L = UNIX systems
# The third character represents the indentation level.
#
option_help_pages=11025_[
**0*_mettre + après un booléen pour activer l'option, - pour la désactiver
**1a_conserve les fichiers assembleurs créés pendant la compilation
**2al_liste le code source dans les fichiers assembleur
**2an_liste les infos de noeud dans le fichier assembleur
*L2ap_utilise des pipes au lieu de fichiers assembleur temporaires
**2ar_liste les allocations de registres dans les fichiers assembleur
**2at_liste les allocations de données temporaire dans la pile
**1A<x>_format de sortie :
**2Adefault_utilise l'assembleur défini par défaut
3*2Aas_fichier objet généré par GNU AS
3*2Anasmcoff_fichier COFF (Go32v2) avec Nasm
3*2Anasmelf_fichier ELF32 (Linux) avec Nasm
3*2Anasmwin32_fichier objet Win32 utilisant Nasm
3*2Anasmwdosx_fichier objet Win32/WDOSX utilisant Nasm
3*2Awasm_fichier objet utilisant Wasm (Watcom)
3*2Anasmobj_fichier OBJ avec Nasm
3*2Amasm_fichier OBJ avec Masm (Microsoft)
3*2Atasm_fichier OBJ avec Tasm (Borland)
3*2Aelf_elf32 (Linux) utilisant le writer interne
3*2Acoff_coff (Go32v2) using internal writer
3*2Apecoff_pecoff (Win32) using internal writer
4*2Aas_fichier objet généré par GNU AS
6*2Aas_fichier .o Unix utilisant GNU AS
6*2Agas_assembleur GNU Motorola
6*2Amit_syntaxe MIT (anciennement GAS)
6*2Amot_assembleur Motorola standard
A*2Aas_assembler avec GNU AS
P*2Aas_assembler avec GNU AS
S*2Aas_assembler avec GNU AS
**1b_génère les informations pour le browser
**2bl_génère les informations locales également
**1B_recompile toutes les unités
**1C<x>_options de génération de code :
**2Cc<x>_définir les convention d'appel <x> par défaut
**2CD_créer une bibliothèque dynamique
**2Ce_compilation avec émulation des opérations à virgule flottante
**2Cf<x>_sélectionner le jeu d'instructions FPU à utiliser, voir fpc -i pour les valeurs possibles
**2Cg_Générer du code PIC
**2Ch<n>_<n> taille du tas en bytes (entre 1023 et 67107840)
**2Ci_IO-checking
**2Cn_pas de linking
**2Co_génère des tests d'overflow pour les opérations sur les entiers
**2Cp<x>_sélectionner le jeu d'instructions, voir fpc -i pour les valeurs possibles
**2Cr_controle d'intervalles
**2CR_vérifier la validité de l'appel à la méthode d'objet
**2Cs<n>_spécifie <n> comme taille de la pile
**2Ct_test de débordement de pile
**2CX_créer également une bibliothèque avec liens optimisés
**1d<x>_définit le symbole <x>
**1D_génère un fichier DEF
**2Dd<x>_assigne la description à <x>
**2Dv<x>_affecter la version <x> à la DLL
*O2Dw_application en mode protégé
**1e<x>_définit le chemin vers l'exécutable
**1E_comme -Cn
**1F<x>_définit des chemins et noms de fichiers :
**2Fa<x>[,y]_Pour un programme charger d'abord les unités <x> et [y] avant que uses ne soit analysé
**2Fc<x>_Utiliser la page de codes <x> en entrée
**2FD<x>_définit le répertoire où chercher les utilitaires de compilation
**2Fe<x>_redirige les erreurs vers le fichier <x>
**2FE<x>_répertoire pour les exe/unités : <x>
**2Fi<x>_ajoute <x> à la liste des répertoires pour fichiers inclus
**2Fl<x>_ajoute <x> à la liste des répertoires pour librairies
**2FL<x>_utilises <x> comme lieur dynamique
**2Fo<x>_ajoute <x> à la liste des répertoires pour fichiers objets
**2Fr<x>_charge le fichier erreur <x>
**2Fu<x>_ajoute <x> à la liste des répertoires pour unités
**2FU<x>_définit le répertoire d'écriture des unités à <x>, en dépit de -FE
*g1g<x>_génère des informations de débogage :
*g2gc_générer des contrôles pour les pointeurs
*g2gd_utilise dbx
*g2gg_utilise gsym
*g2gh_use l'unité de tracage du tas
*g2gl_utiliser l'unité line info pour montrer plus de détails dans les traces
*g2gv_générer des programmes traçables avec valgrind
*g2gw_générer des infos de débogage au format dwarf
**1i_information
**2iD_donne la date du compilateur
**2iV_donne la version du compilateur
**2iW_retourner la version complète du compilateur
**2iSO_donne l'OS du compilateur
**2iSP_donne le processeur du compilateur
**2iTO_donne l'OS cible
**2iTP_donne le processeur cible
**1I<x>_ajoute <x> à la liste des répertoires pour fichiers inclus
**1k<x>_transmet <x> au linker
**1l_écrit le logo
**1M<x>_utiliser le type de langage <x>
**2Mfpc_dialecte Free Pascal (par défaut)
**2Mobjfpc_activation de certaines extensions Delphi 2
**2Mdelphi_essaye d'être compatible avec Delphi
**2Mtp_essaye d'être compatible avec TP/BP 7.0
**2Mgpc_essaye d'être compatible avec gpc
**2Mmacpas_essaye d'être compatible avec les dialectes Pascal du Macintosh
**1n_ne pas lire le fichier de configuration par défaut
**1o<x>_change le nom de l'executable en <x>
**1O<x>_optimisations :
3*2Oa_définir l'alignement <type>=<values>
3*2Og_génère du code compact
3*2OG_génère du code rapide (defaut)
3*2Or_garde certaines variables dans des registres
3*2Ou_autorise les optimisations incertaines (voir docs)
3*2O1_optimisations niveau 1 (optimisations rapides)
3*2O2_optimisations niveau 2 (-O1 + optimisations plus lentes)
3*2O3_optimisations niveau 3 (comme -O2u)
3*2Op<x>_processeur cible :
3*3Op1_définit 386/486 comme processeur cible
3*3Op2_définit Pentium/PentiumMMX (tm) comme processeur cycle
3*3Op3_définit PPro/PII/c6x86/K6 (tm) comme processeur cycle
3*3Op4_définit Pentium 4 (tm) comme processeur cycle
3*3Op5_définit Pentium M (tm) comme processeur cycle
6*2Og_génère du code compact
6*2OG_génère du code rapide (par défaut)
6*2Ox_optimiser au maximum (encore BOGUÉ !!!)
6*2O0_définir le processeur cible MC68000
6*2O2_définir le processeur cible MC68020+
**1pg_génère du code pour profiler avec gprof (définit FPC_PROFILE)
3*1R<x>_type lecture assembleur :
3*2Ratt_lit l'assembleur AT&T
3*2Rintel_lit l'assembleur Intel
4*2Ratt_lit l'assembleur AT&T
4*2Rintel_lit l'assembleur Intel
8*2Ratt_lit l'assembleur AT&T
8*2Rintel_lit l'assembleur Intel
6*2RMOT_lire l'assembleur type Motorola
**1S<x>_options de syntaxe :
**2S2_identique à -Mobjfpc
**2Sa_include assertion code.
**2Sc_autorise les operateurs type C (*=,+=,/= et -=)
**2Sd_identique à -Mdelphi
**2Se<x>_erreur d'options. <x> est une combinaison de :
**3*_<n> : le compilateur s'arrête après <n> erreurs (1 par défaut)
**3*_w : le compilateur s'arrête également en cas d'avertissements
**3*_n : le compilateur s'arrête également en cas de notes
**3*_h : le compilateur s'arrête également en cas de suggestions
**2Sg_autorise LABEL et GOTO
**2Sh_utilise les ansistrings
**2Si_supporte les INLINE type C++
**2SI<x>_définir le style d'interface <x>
**3SIcom_interface compatible COM (par défaut)
**3SIcorba_interface compatible CORBA
**2Sk_charger l'unité fpcylix
**2Sm_support des macros comme C (global)
**2So_identique à -Mtp
**2Sp_identique à -Mgpc
**2Ss_les constructeurs doivent s'appeler init (et les destructeurs done)
**1s_n'appelle pas l'assembleur ni le linker
**2sh_générer un script à lier sur l'hôte
**2st_générer un script à lier sur la cible
**2sr_passer la phase d'allocation de registre (à utiliser avec -alr)
**1T<x>_système d'expliotation cible:
3*2Temx_OS/2 via EMX (et les extensions EMX/RSX)
3*2Tfreebsd_FreeBSD
3*2Tgo32v2_version 2 de l'extension DOS de DJ Delorie
3*2Tlinux_Linux
3*2Tnetbsd_NetBSD
3*2Tnetware_Novell Netware Module (clib)
3*2Tnetwlibc_Novell Netware Module (libc)
3*2Topenbsd_OpenBSD
3*2Tos2_OS/2 / eComStation
3*2Twatcom_DOS extender compatible avec Watcom
3*2Twdosx_WDOSX DOS extension
3*2Twin32_Windows 32 Bits
4*2Tlinux_Linux
6*2Tamiga_Commodore Amiga
6*2Tatari_Atari ST/STe/TT
6*2Tlinux_Linux/m68k
6*2Tmacos_Macintosh m68k
6*2Tpalmos_PalmOS
A*2Tlinux_Linux
P*2Tdarwin_Darwin et MacOS X pour PowerPC
P*2Tlinux_Linux pour PowerPC
P*2Tmacos_MacOS (classique) pour PowerPC
P*2Tmorphos_MorphOS
S*2Tlinux_Linux
**1u<x>_rend le symbole <x> non défini
**1U_options d'unités :
**2Un_ne pas vérifier le nom de l'unité
**2Ur_générer des fichiers d'unité distribuables
**2Us_compiler en temps qu'unité système
**1v<x>_donne des informations. <x> est une combination des lettres suivantes :
**2*_e : montre les erreurs (défaut) 0 : ne montre rien (sauf les erreurs)
**2*_w : montre les avertissements u : montre les info sur les unités
**2*_n : montre les notes t : montre les fichiers essayés/utilisés
**2*_h : montre les suggestions c : montre les conditionniels
**2*_i : montre des infos générales d : informations de déboggage
**2*_l : montre les numéros de lignes r : mode compatibilité Rhide/GCC
**2*_a : montre tout x : infos Executable (Win32 seulement)
**2*_b : montre le nom des fichiers avec chemin complet dans les messages
**2*_v : écrit fpcdebug.txt avec p : écrit tree.log avec arbre d'analyse
**2*_ un maximum d'informations de débogage
3*1W<x>_options pour cibles de type Win32
3*2WB_créer une image relogeable
3*2WB<x>_définir la base de l'Image à la valeur hexadecimale <x>
3*2WC_générer une application console
3*2WD_utiliser DEFFILE pour exporter les fonction de la DLL ou de l'EXE
3*2WF_générer une application plein écran (OS/2 seulement)
3*2WG_générer une application graphique
3*2WN_ne pas générer de code relogeable (nécessaire pour le débogage)
3*2WR_générer du code relogeable
P*2WC_générer une application console (MacOS seulement)
P*2WG_générer une application graphique (MacOS seulement)
P*2WT_générer une application utilitaire (MPW tool, MacOS seulement)
**1X_options pour executable :
**2Xc_passer --shared à l'éditeur de liens (Unix seulement)
**2Xd_ne pas utiliser le chemin de recherche des bibliothèques standard (nécessaire à la compilation pour une autre cible)
**2XD_lien avec la librarie dynamique (définit FPC_LINK_DYNAMIC)
**2Xm_générer un fichier MAP
**2XM<x>_définir le nom de la procédure 'main' ('main' par défaut)
**2XP<x>_prepend the binutils names with the prefix <x>
**2Xr<x>_définir <x> comme chemin de recherche des bibliothèques (nécessaire à la compilation pour une autre cible)
**2Xs_enlêve tous les symboles de l'executable
**2XS_lien avec les librairies statiques (définit FPC_LINK_STATIC)
**2Xt_lier avec des bibliothèques statiques (-static est passé à l'éditeur de liens)
**2XX_essayer de lier les unités intelligemment (définit FPC_LINK_SMART)
**1*_
**1?_affiche cette aide
**1h_affiche cette aide sans attente
]
#
# The End...
%%% parser_e_only_class_methods_via_class_ref=03053_E_Seules des références de classe peuvent faire référence à des méthodes de classe
% This error occurs in a situation like the following:
% \begin{verbatim}
% Type :
% Tclass = Class of Tobject;
%
% Var C : TClass;
%
% begin
% ...
% C.free
% \end{verbatim}
% \var{Free} is not a class method and hence cannot be called with a class
% reference.
%%% parser_e_only_class_methods=03054_E_Seules des méthodes de classe peuvent être appelées dans des méthodes de classe
% This is related to the previous error. You cannot call a method of an object
% from a inside a class method. The following code would produce this error:
% \begin{verbatim}
% class procedure tobject.x;
%
% begin
% free
% \end{verbatim}
% Because free is a normal method of a class it cannot be called from a class
% method.
%%% parser_e_absolute_only_one_var=03095_E_absolute ne peut être associé qu'à une seule variable
% You cannot specify more than one variable before the \var{absolute} directive.
% Thus, the following construct will provide this error:
% \begin{verbatim}
% Var Z : Longint;
% X,Y : Longint absolute Z;
% \end{verbatim}
% \item [ absolute can only be associated a var or const ]
% The address of a \var{absolute} directive can only point to a variable or a
% typed constant. Therefore, the following code will produce this error:
% \begin{verbatim}
% Procedure X;
%
% var p : longint absolute x;
% \end{verbatim}
%
%%% parser_e_only_publishable_classes_can__be_published=03156_E_Seules les classes compilées avec le mode $M+ peuvent être PUBLISHED
% In the published section of a class can be only class as fields used which
% are compiled in \var{\{\$M+\}} or which are derived from such a class. Normally
% such a class should be derived from TPersitent
%%% type_w_mixed_signed_unsigned=04035_W_Le mélange d'expressions signées et de mots longs (longwords) donne un résultat sur 64 bits
% If you divide (or calculate the modulus of) a signed expression by a longword (or vice versa),
% or if you have overflow and/or range checking turned on and use an arithmetic
% expression (+, -, *, div, mod) in which both signed numbers and longwords appear,
% then everything has to be evaluated in 64bit which is slower than normal
% 32bit arithmetic. You can avoid this by typecasting one operand so it
% matches the result type of the other one.
%%% type_w_signed_unsigned_always_false=04044_W_La comparaison est toujours FAUSSE du fait de l'intervalle des valeurs
% There is a comparison between an unsigned value and a signed constant which is
% less than zero. Because of type promotion, the statement will always evaluate to
% false. Exlicitly typecast the constant to the correct range to avoid this problem.
%%% type_w_signed_unsigned_always_true=04045_W_La comparaison est toujours VRAIE du fait de l'intervalle des valeurs
% There is a comparison between an unsigned value and a signed constant which is
% less than zero. Because of type promotion, the statement will always evaluate to
% true. Exlicitly typecast the constant to the correct range to avoid this problem.
%%% type_e_operator_not_allowed=04051_E_L'opérateur n'est pas utilisable pour le type d'opérande
% You are trying an operator that is not available for the type of the
% operands
%%% unit_h_source_modified=10041_H_Le fichier $1 est plus récent que le fichier PPU $2
% A modified source file for a unit was found that was compiled with the
% release flag (-Ur). The unit will not implicitly be recompiled because
% this release flag is set.