mirror of
https://gitlab.com/freepascal.org/fpc/source.git
synced 2025-04-27 17:53:43 +02:00
2369 lines
135 KiB
Plaintext
2369 lines
135 KiB
Plaintext
#
|
||
# This file is part of the Free Pascal Compiler
|
||
# Copyright (c) 1999-2000 by the Free Pascal Development team
|
||
#
|
||
# Spanish Language File for Free Pascal
|
||
#
|
||
# See the file COPYING.FPC, included in this distribution,
|
||
# for details about the copyright.
|
||
#
|
||
# This program is distributed in the hope that it will be useful,
|
||
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
|
||
#
|
||
#
|
||
# The constants are build in the following order:
|
||
# <part>_<type>_<txtidentifier>
|
||
#
|
||
# <part> is the part of the compiler the message is used
|
||
# asmr_ assembler parsing
|
||
# asmw_ assembler writing/binary writers
|
||
|
||
# unit_ unit handling
|
||
# scan_ scanner
|
||
# parser_ parser
|
||
# type_ type checking
|
||
# general_ general info
|
||
# exec_ calls to assembler, linker, binder
|
||
#
|
||
# <type> the type of the message it should normally used for
|
||
# f_ fatal error
|
||
# e_ error
|
||
# w_ warning
|
||
# n_ note
|
||
# h_ hint
|
||
# i_ info
|
||
# l_ add linenumber
|
||
# u_ used
|
||
# t_ tried
|
||
# c_ conditional
|
||
# d_ debug message
|
||
# x_ executable informations
|
||
#
|
||
|
||
#
|
||
# General
|
||
#
|
||
# 01016 is the last used one
|
||
#
|
||
# BeginOfTeX
|
||
% \section{General compiler messages}
|
||
% This section gives the compiler messages which are not fatal, but which
|
||
% display useful information. The number of such messages can be
|
||
% controlled with the various verbosity level \var{-v} switches.
|
||
% \begin{description}
|
||
general_t_compilername=01000_T_Compilador: $1
|
||
% When the \var{-vt} switch is used, this line tells you what compiler
|
||
% is used.
|
||
general_d_sourceos=01001_D_SO del host: $1
|
||
% When the \var{-vd} switch is used, this line tells you what the source
|
||
% operating system is.
|
||
general_i_targetos=01002_I_SO de destino: $1
|
||
% When the \var{-vd} switch is used, this line tells you what the target
|
||
% operating system is.
|
||
general_t_exepath=01003_T_Usando la ruta para ejecutables: $1
|
||
% When the \var{-vt} switch is used, this line tells you where the compiler
|
||
% looks for it's binaries.
|
||
general_t_unitpath=01004_T_Usando la ruta para unidades: $1
|
||
% When the \var{-vt} switch is used, this line tells you where the compiler
|
||
% looks for compiled units. You can set this path with the \var{-Fu}
|
||
general_t_includepath=01005_T_Usando la ruta para inclusiones: $1
|
||
% When the \var{-vt} switch is used, this line tells you where the compiler
|
||
% looks for it's include files (files used in \var{\{\$I xxx\}} statements).
|
||
% You can set this path with the \var{-I} option.
|
||
general_t_librarypath=01006_T_Usando la ruta para bibliotecas: $1
|
||
% When the \var{-vt} switch is used, this line tells you where the compiler
|
||
% looks for the libraries. You can set this path with the \var{-Fl} option.
|
||
general_t_objectpath=01007_T_Usando la ruta para objetos: $1
|
||
% When the \var{-vt} switch is used, this line tells you where the compiler
|
||
% looks for object files you link in (files used in \var{\{\$L xxx\}} statements).
|
||
% You can set this path with the \var{-Fo} option.
|
||
general_i_abslines_compiled=01008_I_$1 Líneas compiladas, $2 seg
|
||
% When the \var{-vi} switch is used, the compiler reports the number
|
||
% of lines compiled, and the time it took to compile them (real time,
|
||
% not program time).
|
||
general_f_no_memory_left=01009_F_No queda suficiente memoria disponible
|
||
% The compiler doesn't have enough memory to compile your program. There are
|
||
% several remedies for this:
|
||
% \begin{itemize}
|
||
% \item If you're using the build option of the compiler, try compiling the
|
||
% different units manually.
|
||
% \item If you're compiling a huge program, split it up in units, and compile
|
||
% these separately.
|
||
% \item If the previous two don't work, recompile the compiler with a bigger
|
||
% heap (you can use the \var{-Ch} option for this, \seeo{Ch})
|
||
% \end{itemize}
|
||
general_i_writingresourcefile=01010_I_Escribiendo archivo de recursos de tabla de cadenas: $1
|
||
% This message is shown when the compiler writes the Resource String Table
|
||
% file containing all the resource strings for a program.
|
||
general_e_errorwritingresourcefile=01011_E_Escribiendo archivo de recursos de tabla de cadenas: $1
|
||
% This message is shown when the compiler encountered an error when writing
|
||
% the Resource String Table file
|
||
general_i_fatal=01012_I_Fatal:
|
||
% Prefix for Fatal Errors
|
||
general_i_error=01013_I_Error:
|
||
% Prefix for Errors
|
||
general_i_warning=01014_I_Aviso:
|
||
% Prefix for Warnings
|
||
general_i_note=01015_I_Nota:
|
||
% Prefix for Notes
|
||
general_i_hint=01016_I_Consejo:
|
||
% Prefix for Hints
|
||
general_e_path_does_not_exist=01017_E_La ruta "$1" no existe
|
||
% The specified path does not exist.
|
||
general_e_compilation_aborted=01018_E_Compilación abortada
|
||
% \end{description}
|
||
#
|
||
# Scanner
|
||
#
|
||
# 02063 is the last used one
|
||
#
|
||
% \section{Scanner messages.}
|
||
% This section lists the messages that the scanner emits. The scanner takes
|
||
% care of the lexical structure of the pascal file, i.e. it tries to find
|
||
% reserved words, strings, etc. It also takes care of directives and
|
||
% conditional compiling handling.
|
||
% \begin{description}
|
||
scan_f_end_of_file=02000_F_Final de fichero inesperado
|
||
% this typically happens in one of the following cases :
|
||
% \begin{itemize}
|
||
% \item The source file ends before the final \var{end.} statement. This
|
||
% happens mostly when the \var{begin} and \var{end} statements aren't
|
||
% balanced;
|
||
% \item An include file ends in the middle of a statement.
|
||
% \item A comment was not closed
|
||
% \end{itemize}
|
||
scan_f_string_exceeds_line=02001_F_La cadena excede la línea
|
||
% There is a missing closing ' in a string, so it occupies
|
||
% multiple lines.
|
||
scan_f_illegal_char=02002_F_Caracter inválido
|
||
% An illegal character was encountered in the input file.
|
||
scan_f_syn_expected=02003_F_Error de sintaxis, se esperaba "$1" pero se encontró "$2"
|
||
% This indicates that the compiler expected a different token than
|
||
% the one you typed. It can occur almost everywhere where you make a
|
||
% mistake against the pascal language.
|
||
scan_t_start_include_file=02004_TL_Empezando a leer el fichero incluido $1
|
||
% When you provide the \var{-vt} switch, the compiler tells you
|
||
% when it starts reading an included file.
|
||
scan_w_comment_level=02005_W_Nivel de comentario anidado $1 encontrado
|
||
% When the \var{-vw} switch is used, then the compiler warns you if
|
||
% it finds nested comments. Nested comments are not allowed in Turbo Pascal
|
||
% and can be a possible source of errors.
|
||
scan_n_ignored_switch=02008_N_Directiva de compilación $1 ignorado
|
||
% With \var{-vn} on, the compiler warns if it ignores a switch
|
||
scan_w_illegal_switch=02009_W_Directiva de compilación $i inválida
|
||
% You included a compiler switch (i.e. \var{\{\$... \}}) which the compiler
|
||
% does not recognise
|
||
scan_w_switch_is_global=02010_W_Esta opción de compilacion tiene un efecto global
|
||
% The compiler switch is misplaced, and should be located at
|
||
% the start of the unit or program.
|
||
scan_e_illegal_char_const=02011_E_Constante de caracter inválido
|
||
% This happens when you specify a character with its ASCII code, as in
|
||
% \var{\#96}, but the number is either illegal, or out of range.
|
||
scan_f_cannot_open_input=02012_F_No se puede abrir el fichero "$1"
|
||
% \fpc cannot find the program or unit source file you specified on the
|
||
% command line.
|
||
scan_f_cannot_open_includefile=02013_F_No se puede abrir el fichero de inclusion "$1"
|
||
% \fpc cannot find the source file you specified in a \var{\{\$include ..\}}
|
||
% statement.
|
||
scan_w_only_pack_records=02015_W_Los campos de los registros pueden ser alineados solo a 1, 2, 4 o 16 bytes
|
||
% You are specifying the \var{\{\$PACKRECORDS n\} } with an illegal value for
|
||
% \var{n}. Only 1, 2, 4, 8, 16 and 32 are valid in this case.
|
||
scan_w_only_pack_enum=02016_W_Los tipos enumerados solo pueden ser almacenados en 1, 2 o 4 bytes
|
||
% You are specifying the \var{\{\$PACKENUM n\}} with an illegal value for
|
||
% \var{n}. Only 1,2 or 4 are valid in this case.
|
||
scan_e_endif_expected=02017_E_$1 esperado para $2 definido en la línea $3
|
||
% Your conditional compilation statements are unbalanced.
|
||
scan_e_preproc_syntax_error=02018_E_Error de sintaxis mientras se procesaba una expresión de compilación condicional
|
||
% There is an error in the expression following the \var{\{\$if ..\}}, $ifc or $setc compiler
|
||
% directives.
|
||
scan_e_error_in_preproc_expr=02019_E_Evaluando una expresión de compilación condicional
|
||
% There is an error in the expression following the \var{\{\$if ..\}}, $ifc or $setc compiler
|
||
% directives.
|
||
scan_w_macro_cut_after_255_chars=02020_W_El contenido de las macros esta limitado a 255 caracteres de longitud
|
||
% The contents of macros cannot be longer than 255 characters.
|
||
scan_e_endif_without_if=02021_E_ENDIF sin IF(N)DEF
|
||
% Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced.
|
||
scan_f_user_defined=02022_F_Error de usuario: $1
|
||
% A user defined fatal error occurred. see also the \progref
|
||
scan_e_user_defined=02023_E_Error de usuario: $1
|
||
% A user defined error occurred. see also the \progref
|
||
scan_w_user_defined=02024_W_Aviso de usuario: $1
|
||
% A user defined warning occurred. see also the \progref
|
||
scan_n_user_defined=02025_N_Nota de usuario: $1
|
||
% A user defined note was encountered. see also the \progref
|
||
scan_h_user_defined=02026_H_Consejo de usuario: $1
|
||
% A user defined hint was encountered. see also the \progref
|
||
scan_i_user_defined=02027_I_Informacion de usuario: $1
|
||
% User defined information was encountered. see also the \progref
|
||
scan_e_keyword_cant_be_a_macro=02028_E_Palabra clave redefinida como macro no tiene efecto
|
||
% You cannot redefine keywords with macros.
|
||
scan_f_macro_buffer_overflow=02029_F_Desbordamiento del buffer de macro durante la lextura o expansión
|
||
% Your macro or it's result was too long for the compiler.
|
||
can_w_macro_too_deep=02030_W_La expansión de macros excede una profundidad de 16.
|
||
% When expanding a macro, macros have been nested to a level of 16.
|
||
% The compiler will expand no further, since this may be a sign that
|
||
% recursion is used.
|
||
scan_w_wrong_styled_switch=02031_W_Las directivas de compilacióon no estan soportadas en comentarios estilo //
|
||
% Compiler switches should be in normal pascal style comments.
|
||
scan_d_handling_switch=02032_DL_Manejando la directiva "$1"
|
||
% When you set debugging info on (\var{-vd}) the compiler tells you when it
|
||
% is evaluating conditional compile statements.
|
||
scan_c_endif_found=02033_CL_ENDIF $1 encontrado
|
||
% When you turn on conditional messages(\var{-vc}), the compiler tells you
|
||
% where it encounters conditional statements.
|
||
scan_c_ifdef_found=02034_CL_IFDEF $1 encontrado, $2
|
||
% When you turn on conditional messages(\var{-vc}), the compiler tells you
|
||
% where it encounters conditional statements.
|
||
scan_c_ifopt_found=02035_CL_IFOPT $1 encontrado, $2
|
||
% When you turn on conditional messages(\var{-vc}), the compiler tells you
|
||
% where it encounters conditional statements.
|
||
scan_c_if_found=02036_CL_IF $1 encontrado, $2
|
||
% When you turn on conditional messages(\var{-vc}), the compiler tells you
|
||
% where it encounters conditional statements.
|
||
scan_c_ifndef_found=02037_CL_IFNDEF $1 encontrado, $2
|
||
% When you turn on conditional messages(\var{-vc}), the compiler tells you
|
||
% where it encounters conditional statements.
|
||
scan_c_else_found=02038_CL_ELSE $1 encontrado, $2
|
||
% When you turn on conditional messages(\var{-vc}), the compiler tells you
|
||
% where it encounters conditional statements.
|
||
scan_c_skipping_until=02039_CL_Omitiendo hasta...
|
||
% When you turn on conditional messages(\var{-vc}), the compiler tells you
|
||
% where it encounters conditional statements, and whether it is skipping or
|
||
% compiling parts.
|
||
scan_i_press_enter=02040_I_Presione <retorno> para continuar
|
||
% When the \var{-vi} switch is used, the compiler stops compilation
|
||
% and waits for the \var{Enter} key to be pressed when it encounters
|
||
% a \var{\{\$STOP\}} directive.
|
||
scan_w_unsupported_switch=02041_W_Conmutador "$1" no soportado
|
||
% When warnings are turned on (\var{-vw}) the compiler warns you about
|
||
% unsupported switches. This means that the switch is used in Delphi or
|
||
% Turbo Pascal, but not in \fpc
|
||
scan_w_illegal_directive=02042_W_Directiva de compilación "$1" inválida
|
||
% When warings are turned on (\var{-vw}) the compiler warns you about
|
||
% unrecognised switches. For a list of recognised switches, \progref
|
||
scan_t_back_in=02043_TL_Vuelve en $1
|
||
% When you use (\var{-vt}) the compiler tells you when it has finished
|
||
% reading an include file.
|
||
scan_w_unsupported_app_type=02044_W_Tipo de aplicación no soportada: "$1"
|
||
% You get this warning, ff you specify an unknown application type
|
||
% with the directive \var{\{\$APPTYPE\}}
|
||
scan_w_app_type_not_support=02045_W_APPTYPE no es soportado por el SO de destino
|
||
% The \var{\{\$APPTYPE\}} directive is supported by certain operating systems only.
|
||
scan_w_description_not_support=02046_W_DESCRIPTION no es soportado por el SO de destino
|
||
% The \var{\{\$DESCRIPTION\}} directive is not supported on this target OS
|
||
scan_n_version_not_support=02047_N_VERSION no es soportado por el SO de destino
|
||
% The \var{\{\$VERSION\}} directive is not supported on this target OS
|
||
scan_n_only_exe_version=02048_N_VERSION sólo para EXEs o DLLs
|
||
% The \var{\{\$VERSION\}} directive is only used for executable or DLL sources.
|
||
scan_w_wrong_version_ignored=02049_W_Formato erroneo para la directiva VERSION: "$1"
|
||
% The \var{\{\$VERSION\}} directive format is majorversion.minorversion
|
||
% where majorversion and minorversion are words.
|
||
scan_e_illegal_asmmode_specifier=02050_E_Estilo de ensamblador inváalido especificado: "$1"
|
||
% When you specify an assembler mode with the \var{\{\$ASMMODE xxx\}}
|
||
% the compiler didn't recognize the mode you specified.
|
||
scan_w_no_asm_reader_switch_inside_asm=02051_W_No es posible cambiar el lector dentro de una sentencia asm. "$1" solo sera efectivo en los siguientes
|
||
% It is not possible to switch from one assembler reader to another
|
||
% inside an assmebler block. The new reader will be used for next
|
||
% assembler statements only.
|
||
scan_e_wrong_switch_toggle=02052_E_Modificador de conmutador erróneo, use ON/OFF o +/-
|
||
% You need to use ON or OFF or a + or - to toggle the switch
|
||
scan_e_resourcefiles_not_supported=02053_E_Los ficheros de recursos no son soportados por la plataforma de destino
|
||
% The target you are compiling for doesn't support resource files.
|
||
scan_w_include_env_not_found=02054_W_Variable de entorno incluida "$1" no encontrada.
|
||
% The included environment variable can't be found in the environment, it will
|
||
% be replaced by an empty string instead.
|
||
scan_e_invalid_maxfpureg_value=02055_E_Valor inválido para el registro de la FPU
|
||
% Valid values for this directive are 0..8 and NORMAL/DEFAULT
|
||
scan_w_only_one_resourcefile_supported=02056_W_La plataforma de destino solo soporta un archivo de recursos
|
||
% The target you are compiling for supports only one resource file.
|
||
% The first resource file found is used, the others are discarded.
|
||
scan_w_macro_support_turned_off=02057_W_El soporte para macros ha sido deshabilitado
|
||
% A macro declaration has been found, but macro support is currently off,
|
||
% so the declaration will be ignored. To turn macro support on compile with
|
||
% -Sm on the commandline or add \{\$MACRO ON\} in the source
|
||
scan_e_invalid_interface_type=02058_E_El tipo de interfaz especificado es inválido. Debe ser COM, CORBA o DEFAULT
|
||
% The interface type that was specified is not supported
|
||
scan_w_appid_not_support=02059_W_APPID solo esta soportado para PalmOS
|
||
% The \var{\{\$APPID\}} directive is only supported for the PalmOS target.
|
||
scan_w_appname_not_support=02060_W_APPNAME solo esta soportado para PalmOS
|
||
% The \var{\{\$APPNAME\}} directive is only supported for the PalmOS target.
|
||
scan_e_string_exceeds_255_chars=02061_E_Las constantes de cadena no pueden ser de mas de 255 caracteres de longitud
|
||
% A single string constant can contain at most 255 chars. Try splitting up the
|
||
% string in multiple smaller parts and concatenate them with a + operator.
|
||
scan_f_include_deep_ten=02062_F_La inclusion de archivos no puede exceder 16 niveles
|
||
% When including include files the files have been nested to a level of 16.
|
||
% The compiler will expand no further, since this may be a sign that
|
||
% recursion is used.
|
||
scan_e_too_many_push=02063_F_Demasiados niveles de PUSH
|
||
% A maximum of 20 levels is allowed. This error occur only in mode MacPas.
|
||
scan_e_too_many_pop=02064_E_A POP sin un PUSH previo
|
||
% This error occur only in mode MacPas.
|
||
scan_e_error_macro_lacks_value=02065_E_Macro o variable de compilación "$1" no tiene ningún valor
|
||
% Thus the conditional compiling expression cannot be evaluated.
|
||
scan_e_wrong_switch_toggle_default=02066_E_Valor invalido para el conmutado, use ON/OFF/DEFAULT o +/-/*
|
||
% You need to use ON or OFF or DEFAULT or a + or - or * to toggle the switch
|
||
scan_e_mode_switch_not_allowed=02067_E_No esta permitido cambiar de modo a "$1" aqui
|
||
% A mode switch has already been encountered, or, in case of option -Mmacpas,
|
||
% a mode switch occur after UNIT.
|
||
scan_e_error_macro_undefined=02068_E_Variable en tiempo de compilación "$1" no ha sido definida.
|
||
% Thus the conditional compile time expression cannot be evaluated.
|
||
% \end{description}
|
||
#
|
||
# Parser
|
||
#
|
||
# 03192 is the last used one
|
||
#
|
||
% \section{Parser messages}
|
||
% This section lists all parser messages. The parser takes care of the
|
||
% semantics of you language, i.e. it determines if your pascal constructs
|
||
% are correct.
|
||
% \begin{description}
|
||
parser_e_syntax_error=03000_E_Analizador - Error de sintaxis
|
||
% An error against the Turbo Pascal language was encountered. This happens
|
||
% typically when an illegal character is found in the sources file.
|
||
parser_e_dont_nest_interrupt=03004_E_Los procedimientos INTERRUPT no pueden ser anidados
|
||
% An \var{INTERRUPT} procedure must be global.
|
||
parser_w_proc_directive_ignored=03005_W_Tipo de procedimiento "$1" ignorado
|
||
% The specified is ignored by FPC programs.
|
||
parser_e_no_overload_for_all_procs=03006_E_No todas las declaraciones de "$1" llevan OVERLOAD
|
||
% When you want to use overloading using the \var{OVERLOAD} directive, then
|
||
% all declarations need to have \var{OVERLOAD} specified.
|
||
parser_e_export_name_double=03008_E_Nombre de funcion exportada "$1" duplicado
|
||
% Exported function names inside a specific DLL must all be different
|
||
parser_e_export_ordinal_double=03009_E_Indice de funcion exportada "$1" duplicado
|
||
% Exported function names inside a specific DLL must all be different
|
||
parser_e_export_invalid_index=03010_E_Indice de funcion exportada inválido
|
||
% DLL function index must be in the range \var{1..\$FFFF}
|
||
parser_w_parser_reloc_no_debug=03011_W_La informacion de depurado $1 para ejecutables o DLLs reubicables no funciona. Desactivado.
|
||
parser_w_parser_win32_debug_needs_WN=03012_W_Para permitir el depurado en win32 las reubicaciones deben ser desactivadas con la opcion -WN
|
||
% Stabs info is wrong for relocatable DLL or EXES use -WN
|
||
% if you want to debug win32 executables.
|
||
parser_e_constructorname_must_be_init=03013_E_El nombre del constructor debe ser INIT
|
||
% You are declaring an object constructor with a name which is not \var{init}, and the
|
||
% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
|
||
parser_e_destructorname_must_be_done=03014_E_El nombre del destructor debe ser DONE
|
||
% You are declaring an object destructor with a name which is not \var{done}, and the
|
||
% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
|
||
parser_e_proc_inline_not_supported=03016_E_Procedimientos tipo INLINE no soportados
|
||
% You tried to compile a program with C++ style inlining, and forgot to
|
||
% specify the \var{-Si} option (\seeo{Si}). The compiler doesn't support C++
|
||
% styled inlining by default.
|
||
parser_w_constructor_should_be_public=03018_W_El constructor debería ser público
|
||
% Constructors must be in the 'public' part of an object (class) declaration.
|
||
parser_w_destructor_should_be_public=03019_W_El destructor debería ser público
|
||
% Destructors must be in the 'public' part of an object (class) declaration.
|
||
parser_n_only_one_destructor=03020_N_Una clase debería tener solo un destructor
|
||
% You can declare only one destructor for a class.
|
||
parser_e_no_local_objects=03021_E_Las definiciones de clases locales no están permitidas
|
||
% Classes must be defined globally. They cannot be defined inside a
|
||
% procedure or function
|
||
parser_f_no_anonym_objects=03022_F_Las definiciones de clases anónimas no están permitidas
|
||
% An invalid object (class) declaration was encountered, i.e. an
|
||
% object or class without methods that isn't derived from another object or
|
||
% class. For example:
|
||
% \begin{verbatim}
|
||
% Type o = object
|
||
% a : longint;
|
||
% end;
|
||
% \end{verbatim}
|
||
% will trigger this error.
|
||
parser_n_object_has_no_vmt=03023_N_El objeto "$1" no tiene VMT
|
||
% This is a note indicating that the declared object has no
|
||
% virtual method table.
|
||
parser_e_illegal_parameter_list=03024_E_Lista de parámetros inválida
|
||
% You are calling a function with parameters that are of a different type than
|
||
% the declared parameters of the function.
|
||
parser_e_wrong_parameter_size=03026_E_Numero de parámetros incorrecto
|
||
% There is an error in the parameter list of the function or procedure,
|
||
% the number of parameters is not correct.
|
||
parser_e_overloaded_no_procedure=03027_E_el identificador sobrecargado "$1" no es una función
|
||
% The compiler encountered a symbol with the same name as an overloaded
|
||
% function, but it is not a function it can overload.
|
||
parser_e_overloaded_have_same_parameters=03028_E_funciones sobrecargadas tienen los mismos par metros
|
||
% You're declaring overloaded functions, but with the same parameter list.
|
||
% Overloaded function must have at least 1 different parameter in their
|
||
% declaration.
|
||
parser_e_header_dont_match_forward=03029_E_la cabecera de la función no concuerda con la declaración posterior "$1"
|
||
% You declared a function with same parameters but
|
||
% different result type or function modifiers.
|
||
parser_e_header_different_var_names=03030_E_la cabecera de la funcion "$1" no concuerda con la posterior declaración : el nombre de la variable cambia $2 => $3
|
||
% You declared the function in the \var{interface} part, or with the
|
||
% \var{forward} directive, but define it with a different parameter list.
|
||
parser_n_duplicate_enum=03031_N_el orden de los valores en una enumeracion debe ser ascendente
|
||
% \fpc allows enumeration constructions as in C. Given the following
|
||
% declaration two declarations:
|
||
% \begin{verbatim}
|
||
% type a = (A_A,A_B,A_E:=6,A_UAS:=200);
|
||
% type a = (A_A,A_B,A_E:=6,A_UAS:=4);
|
||
% \end{verbatim}
|
||
% The second declaration would produce an error. \var{A\_UAS} needs to have a
|
||
% value higher than \var{A\_E}, i.e. at least 7.
|
||
parser_e_no_with_for_variable_in_other_segments=03033_E_With no puede ser usado con variables en segmentos diferentes
|
||
% With stores a variable locally on the stack,
|
||
% but this is not possible if the variable belongs to another segment.
|
||
parser_e_too_much_lexlevel=03034_E_Anidado de funciones > 31
|
||
% You can nest function definitions only 31 times.
|
||
parser_e_range_check_error=03035_E_error en la comprobación de rangos mientras se evaluaban constantes
|
||
% The constants are out of their allowed range.
|
||
parser_w_range_check_error=03036_W_error en la comprobacion de rangos mientras se evaluaban constantes
|
||
% The constants are out of their allowed range.
|
||
parser_e_double_caselabel=03037_E_etiqueta de caso duplicada
|
||
% You are specifying the same label 2 times in a \var{case} statement.
|
||
parser_e_case_lower_less_than_upper_bound=03038_E_El líimite superior del caso es menor que el inferior
|
||
% The upper bound of a \var{case} label is less than the lower bound and this
|
||
% is useless
|
||
parser_e_type_const_not_possible=03039_E_no se permiten constantes con tipo de clases
|
||
% You cannot declare a constant of type class or object.
|
||
parser_e_no_overloaded_procvars=03040_E_no se permite asignar a variables de funcion funciones sobrecargadas
|
||
% You are trying to assign an overloaded function to a procedural variable.
|
||
% This is not allowed
|
||
parser_e_invalid_string_size=03041_E_la longitud de una cadena tiene que ser un valor entre 1 y 255
|
||
% The length of a shortstring in Pascal is limited to 255 characters. You are
|
||
% trying to declare a string with length lower than 1 or greater than 255
|
||
parser_w_use_extended_syntax_for_objects=03042_W_use la sintaxis estendida de DISPOSE y NEW para instancias de objetos
|
||
% If you have a pointer \var{a} to a class type, then the statement
|
||
% \var{new(a)} will not initialize the class (i.e. the constructor isn't
|
||
% called), although space will be allocated. you should issue the
|
||
% \var{new(a,init)} statement. This will allocate space, and call the
|
||
% constructor of the object
|
||
parser_w_no_new_dispose_on_void_pointers=03043_W_el uso de NEW o DISPOSE para punteros sin tipo no tiene sentido
|
||
parser_e_no_new_dispose_on_void_pointers=03044_E_el uso de NEW o DISPOSE no es posible con punteros sin tipo
|
||
% You cannot use \var{new(p)} or \var{dispose(p)} if \var{p} is an untyped pointer
|
||
% because no size is associated to an untyped pointer.
|
||
% Accepted for compatibility in \var{tp} and \var{delphi} modes.
|
||
parser_e_class_id_expected=03045_E_identificador de clase esperado
|
||
% This happens when the compiler scans a procedure declaration that contains
|
||
% a dot,
|
||
% i.e., a object or class method, but the type in front of the dot is not
|
||
% a known type.
|
||
parser_e_no_type_not_allowed_here=03046_E_identificador de tipo no permitido aquí
|
||
% You cannot use a type inside an expression.
|
||
parser_e_methode_id_expected=03047_E_identificador de método esperado
|
||
% This identifier is not a method.
|
||
% This happens when the compiler scans a procedure declaration that contains
|
||
% a dot, i.e., a object or class method, but the procedure name is not a
|
||
% procedure of this type.
|
||
parser_e_header_dont_match_any_member=03048_E_la cabecera de la funcion no concuerda con ningún método de esta clase "$1"
|
||
% This identifier is not a method.
|
||
% This happens when the compiler scans a procedure declaration that contains
|
||
% a dot, i.e., a object or class method, but the procedure name is not a
|
||
% procedure of this type.
|
||
parser_d_procedure_start=03049_DL_proceduimiento/función $1
|
||
% When using the \var{-vd} switch, the compiler tells you when it starts
|
||
% processing a procedure or function implementation.
|
||
parser_e_error_in_real=03050_E_Constante de punto flotante inválida
|
||
% The compiler expects a floating point expression, and gets something else.
|
||
parser_e_fail_only_in_constructor=03051_E_FAIL solo puede ser usado en constructores
|
||
% You are using the \var{fail} keyword outside a constructor method.
|
||
parser_e_no_paras_for_destructor=03052_E_Los destructores no pueden tener parámetros
|
||
% You are declaring a destructor with a parameter list. Destructor methods
|
||
% cannot have parameters.
|
||
parser_e_only_class_methods_via_class_ref=03053_E_Solo los métodos de clases pueden ser referidos con referencias de clase
|
||
% This error occurs in a situation like the following:
|
||
% \begin{verbatim}
|
||
% Type :
|
||
% Tclass = Class of Tobject;
|
||
%
|
||
% Var C : TClass;
|
||
%
|
||
% begin
|
||
% ...
|
||
% C.free
|
||
% \end{verbatim}
|
||
% \var{Free} is not a class method and hence cannot be called with a class
|
||
% reference.
|
||
parser_e_only_class_methods=03054_E_Los métodos de clase solo pueden ser acceder a otros métodos de clase
|
||
% This is related to the previous error. You cannot call a method of an object
|
||
% from a inside a class method. The following code would produce this error:
|
||
% \begin{verbatim}
|
||
% class procedure tobject.x;
|
||
%
|
||
% begin
|
||
% free
|
||
% \end{verbatim}
|
||
% Because free is a normal method of a class it cannot be called from a class
|
||
% method.
|
||
parser_e_case_mismatch=03055_E_Los tipos de la constante y del CASE no concuerdan
|
||
% One of the labels is not of the same type as the case variable.
|
||
parser_e_illegal_symbol_exported=03056_E_El símbolo no puede ser exportado de una librería
|
||
% You can only export procedures and functions when you write a library. You
|
||
% cannot export variables or constants.
|
||
parser_w_should_use_override=03057_W_Un método heredado ha sido ocultado por "$1"
|
||
% A method that is declared \var{virtual} in a parent class, should be
|
||
% overridden in the descendent class with the \var{override} directive. If you
|
||
% don't specify the \var{override} directive, you will hide the parent method;
|
||
% you will not override it.
|
||
parser_e_nothing_to_be_overridden=03058_E_No hay un método en una clase antepasada para ser substituido: "$1"
|
||
% You are trying to \var{override} a virtual method of a parent class that does
|
||
% not exist.
|
||
parser_e_no_procedure_to_access_property=03059_E_No se suministro un miembro para acceder a propiedad
|
||
% You specified no \var{read} directive for a property.
|
||
parser_w_stored_not_implemented=03060_W_La directiva de propiedad Stored no esta implementada aún
|
||
% The \var{stored} directive is not yet implemented
|
||
parser_e_ill_property_access_sym=03061_E_símbolo inváalido para el acceso a la propiedad
|
||
% There is an error in the \var{read} or \var{write} directives for an array
|
||
% property. When you declare an array property, you can only access it with
|
||
% procedures and functions. The following code woud cause such an error.
|
||
% \begin{verbatim}
|
||
% tmyobject = class
|
||
% i : integer;
|
||
% property x [i : integer]: integer read I write i;
|
||
% \end{verbatim}
|
||
%
|
||
parser_e_cant_access_protected_member=03062_E_No se puede acceder a un campo protegido de un objeto aquí
|
||
% Fields that are declared in a \var{protected} section of an object or class
|
||
% declaration cannot be accessed outside the module wher the object is
|
||
% defined, or outside descendent object methods.
|
||
parser_e_cant_access_private_member=03063_E_No se puede acceder a un campo privado de un objeto aquí
|
||
% Fields that are declared in a \var{private} section of an object or class
|
||
% declaration cannot be accessed outside the module where the class is
|
||
% defined.
|
||
parser_e_overridden_methods_not_same_ret=03066_E_los métodos reemplazados deben tener el mismo tipo de dato devuelto: "$2" es reemplazado por "$1" que devuelve otro tipo
|
||
% If you declare overridden methods in a class definition, they must
|
||
% have the same return type.
|
||
parser_e_dont_nest_export=03067_E_Las funciones declarados como EXPORT no pueden estar anidados
|
||
% You cannot declare a function or procedure within a function or procedure
|
||
% that was declared as an export procedure.
|
||
parser_e_methods_dont_be_export=03068_E_los métodos no pueden ser EXPORTados
|
||
% You cannot declare a procedure that is a method for an object as
|
||
% \var{export}ed.
|
||
parser_e_call_by_ref_without_typeconv=03069_E_en llamadas con parámetros VAR los tipos deben coincidir exactamente. Se recibio "$1" cuando se esperaba "$2"
|
||
% When calling a function declared with \var{var} parameters, the variables in
|
||
% the function call must be of exactly the same type. There is no automatic
|
||
% type conversion.
|
||
parser_e_no_super_class=03070_E_La clase no es un ancestor de la clase actual
|
||
% When calling inherited methods, you are trying to call a method of a non-related
|
||
% class. You can only call an inherited method of a parent class.
|
||
parser_e_self_not_in_method=03071_E_SELF solo está permitido en métodos
|
||
% You are trying to use the \var{self} parameter outside an object's method.
|
||
% Only methods get passed the \var{self} parameters.
|
||
parser_e_generic_methods_only_in_methods=03072_E_los métodos solo pueden estar en otros métodos llamados directamente con el tipo identificador de la clase
|
||
% A construction like \var{sometype.somemethod} is only allowed in a method.
|
||
parser_e_illegal_colon_qualifier=03073_E_Uso inválido de ':'
|
||
% You are using the format \var{:} (colon) 2 times on an expression that
|
||
% is not a real expression.
|
||
parser_e_illegal_set_expr=03074_E_Error en la comprobación de rangos en el constructor del set, o elemento duplicado en el set
|
||
% The declaration of a set contains an error. Either one of the elements is
|
||
% outside the range of the set type, either two of the elements are in fact
|
||
% the same.
|
||
parser_e_pointer_to_class_expected=03075_E_Se esperaba un puntero a objeto
|
||
% You specified an illegal type in a \var{new} statement.
|
||
% The extended syntax of \var{new} needs an object as a parameter.
|
||
parser_e_expr_have_to_be_constructor_call=03076_E_La expresión tiene que ser una llamada al constructor
|
||
% When using the extended syntax of \var{new}, you must specify the constructor
|
||
% method of the object you are trying to create. The procedure you specified
|
||
% is not a constructor.
|
||
parser_e_expr_have_to_be_destructor_call=03077_E_La expresión tiene que ser una llamada al destructor
|
||
% When using the extended syntax of \var{dispose}, you must specify the
|
||
% destructor method of the object you are trying to dispose of.
|
||
% The procedure you specified is not a destructor.
|
||
parser_e_invalid_record_const=03078_E_Orden de los campos del registro incorrecto
|
||
% When declaring a constant record, you specified the fields in the wrong
|
||
% order.
|
||
parser_e_false_with_expr=03079_E_El tipo de la expresión tiene que ser class o record
|
||
% A \var{with} statement needs an argument that is of the type \var{record}
|
||
% or \var{class}. You are using \var{with} on an expression that is not of
|
||
% this type.
|
||
parser_e_void_function=03080_E_Los procedimientos no pueden devolver ningún valor
|
||
% In \fpc, you can specify a return value for a function when using
|
||
% the \var{exit} statement. This error occurs when you try to do this with a
|
||
% procedure. Procedures cannot return a value.
|
||
parser_e_constructors_always_objects=03081_E_constructores y destructores deben ser métodos
|
||
% You're declaring a procedure as destructor or constructor, when the
|
||
% procedure isn't a class method.
|
||
parser_e_operator_not_overloaded=03082_E_El operador no esta sobrecargado
|
||
% You're trying to use an overloaded operator when it is not overloaded for
|
||
% this type.
|
||
parser_e_no_such_assignment=03083_E_Imposible sobrecargar operador de asignacion para tipos iguales
|
||
% You can not overload assignment for types
|
||
% that the compiler considers as equal.
|
||
parser_e_overload_impossible=03084_E_Sobrecarga de operador imposible
|
||
% The combination of operator, arguments and return type are
|
||
% incompatible.
|
||
parser_e_no_reraise_possible=03085_E_Re-lanzamiento de la excepcion no es posible aquí
|
||
% You are trying to raise an exception where it is not allowed. You can only
|
||
% raise exceptions in an \var{except} block.
|
||
parser_e_no_new_or_dispose_for_classes=03086_E_La sintaxis extendida de new o dispose no está permitida para una clase
|
||
% You cannot generate an instance of a class with the extended syntax of
|
||
% \var{new}. The constructor must be used for that. For the same reason, you
|
||
% cannot call \var{dispose} to de-allocate an instance of a class, the
|
||
% destructor must be used for that.
|
||
parser_e_procedure_overloading_is_off=03088_E_La sobrecarga de funciones no esta activada
|
||
% When using the \var{-So} switch, procedure overloading is switched off.
|
||
% Turbo Pascal does not support function overloading.
|
||
parser_e_overload_operator_failed=03089_E_No es posible sobrecargar este operador (sobrecarge en cambio "=" )
|
||
% You are trying to overload an operator which cannot be overloaded.
|
||
% The following operators can be overloaded :
|
||
% \begin{verbatim}
|
||
% +, -, *, /, =, >, <, <=, >=, is, as, in, **, :=
|
||
% \end{verbatim}
|
||
parser_e_comparative_operator_return_boolean=03090_E_Operador comparativo tiene que devolver un valor booleano
|
||
% When overloading the \var{=} operator, the function must return a boolean
|
||
% value.
|
||
parser_e_only_virtual_methods_abstract=03091_E_Solo los métodos virtuales pueden ser abstractos
|
||
% You are declaring a method as abstract, when it is not declared to be
|
||
% virtual.
|
||
parser_f_unsupported_feature=03092_F_Uso de característica no soportada!
|
||
% You're trying to force the compiler into doing something it cannot do yet.
|
||
parser_e_mix_of_classes_and_objects=03093_E_No se permite la mezcla de objetos de diferentes tipos (class, object, interface, etc)
|
||
% You cannot derive \var{objects}, \var{classes}, \var{cppclasses} and \var{interfaces} interttwined . E.g.
|
||
% a class cannot have an object as parent and vice versa.
|
||
parser_w_unknown_proc_directive_ignored=03094_W_Directiva de procedimiento desconocida fue ignorada: "$1"
|
||
% The procedure directive you specified is unknown.
|
||
parser_e_absolute_only_one_var=03095_E_absolute solo puede estar asociado a una variable
|
||
% You cannot specify more than one variable before the \var{absolute} directive.
|
||
% Thus, the following construct will provide this error:
|
||
% \begin{verbatim}
|
||
% Var Z : Longint;
|
||
% X,Y : Longint absolute Z;
|
||
% \end{verbatim}
|
||
% \item [ absolute can only be associated a var or const ]
|
||
% The address of a \var{absolute} directive can only point to a variable or a
|
||
% typed constant. Therefore, the following code will produce this error:
|
||
% \begin{verbatim}
|
||
% Procedure X;
|
||
%
|
||
% var p : longint absolute x;
|
||
% \end{verbatim}
|
||
%
|
||
parser_e_absolute_only_to_var_or_const=03096_E_absolute solo puede ser asociado con var o const
|
||
% The address of a \var{absolute} directive can only point to a variable or
|
||
% constant. Therefore, the following code will produce this error:
|
||
% \begin{verbatim}
|
||
% Procedure X;
|
||
%
|
||
% var p : longint absolute x;
|
||
% \end{verbatim}
|
||
%
|
||
parser_e_initialized_only_one_var=03097_E_Solo una variable puede ser inicializada
|
||
% You cannot specify more than one variable with a initial value
|
||
% in Delphi mode.
|
||
parser_e_abstract_no_definition=03098_E_Métodos abstractos no deberían tener ninguna definición (con el cuerpo de la función)
|
||
% Abstract methods can only be declared, you cannot implement them. They
|
||
% should be overridden by a descendant class.
|
||
parser_e_overloaded_must_be_all_global=03099_E_Esta función sobrecargada no puede ser local (debe ser exportada)
|
||
% You are defining a overloaded function in the implementation part of a unit,
|
||
% but there is no corresponding declaration in the interface part of the unit.
|
||
parser_w_virtual_without_constructor=03100_W_Métodos virtuales están siendo usados sin un constructor en "$1"
|
||
% If you declare objects or classes that contain virtual methods, you need
|
||
% to have a constructor and destructor to initialize them. The compiler
|
||
% encountered an object or class with virtual methods that doesn't have
|
||
% a constructor/destructor pair.
|
||
parser_c_macro_defined=03101_CL_Macro definido: $1
|
||
% When \var{-vc} is used, the compiler tells you when it defines macros.
|
||
parser_c_macro_undefined=03102_CL_Macro indefinido: $1
|
||
% When \var{-vc} is used, the compiler tells you when it undefines macros.
|
||
parser_c_macro_set_to=03103_CL_Macro $1 asignado a $2
|
||
% When \var{-vc} is used, the compiler tells you what values macros get.
|
||
parser_i_compiling=03104_I_Compilando $1
|
||
% When you turn on information messages (\var{-vi}), the compiler tells you
|
||
% what units it is recompiling.
|
||
parser_u_parsing_interface=03105_UL_Interpretando interfaz de la unidad $1
|
||
% This tells you that the reading of the interface
|
||
% of the current unit starts
|
||
parser_u_parsing_implementation=03106_UL_Interpretando implementacion de la unidad $1
|
||
% This tells you that the code reading of the implementation
|
||
% of the current unit, library or program starts
|
||
parser_d_compiling_second_time=03107_DL_Compilando $1 por segunda vez
|
||
% When you request debug messages (\var{-vd}) the compiler tells you what
|
||
% units it recompiles for the second time.
|
||
parser_e_no_property_found_to_override=03109_E_No se encontro la propiedad a reemplazar
|
||
% You want to overrride a property of a parent class, when there is, in fact,
|
||
% no such property in the parent class.
|
||
parser_e_only_one_default_property=03110_E_Sólo se permite una única propiedad por defecto
|
||
% You specified a property as \var{Default}, but the class already has a
|
||
% default property, and a class can have only one default property.
|
||
parser_e_property_need_paras=03111_E_La propiedad por defecto tiene que ser un array
|
||
% Only array properties of classes can be made \var{default} properties.
|
||
parser_e_constructor_cannot_be_not_virtual=03112_E_Solo las clases soportan constructores virtuales
|
||
% You cannot have virtual constructors in objects. You can only have them
|
||
% in classes.
|
||
parser_e_no_default_property_available=03113_E_No hay propiedad por defecto disponible
|
||
% You are trying to access a default property of a class, but this class (or one of
|
||
% it's ancestors) doesn't have a default property.
|
||
parser_e_cant_have_published=03114_E_La clase no puede tener una sección published, use el conmutador {$M+}
|
||
% If you want a \var{published} section in a class definition, you must
|
||
% use the \var{\{\$M+\}} switch, whch turns on generation of type
|
||
% information.
|
||
parser_e_forward_declaration_must_be_resolved=03115_E_Declaración posterior de la clase "$1" tiene que ser resuelta aquí para usar la clase como antepasado
|
||
% To be able to use an object as an ancestor object, it must be defined
|
||
% first. This error occurs in the following situation:
|
||
% \begin{verbatim}
|
||
% Type ParentClas = Class;
|
||
% ChildClass = Class(ParentClass)
|
||
% ...
|
||
% end;
|
||
% \end{verbatim}
|
||
% Where \var{ParentClass} is declared but not defined.
|
||
parser_e_no_local_operator=03116_E_Operadores locales no soportados
|
||
% You cannot overload locally, i.e. inside procedures or function
|
||
% definitions.
|
||
parser_e_proc_dir_not_allowed_in_interface=03117_E_Directiva de procedimiento "$1" no permitida en la sección de interfaz
|
||
% This procedure directive is not allowed in the \var{interface} section of
|
||
% a unit. You can only use it in the \var{implementation} section.
|
||
parser_e_proc_dir_not_allowed_in_implementation=03118_E_Directiva de procedimiento "$1" no permitida en la sección de implementacion
|
||
% This procedure directive is not defined in the \var{implementation} section of
|
||
% a unit. You can only use it in the \var{interface} section.
|
||
parser_e_proc_dir_not_allowed_in_procvar=03119_E_Directiva de procedimiento "$1" no permitida en la declaración de tipo
|
||
% This procedure directive cannot be part of a procedural or function
|
||
% type declaration.
|
||
parser_e_function_already_declared_public_forward=03120_E_La función esta actualmente declarada como Public/Forward "$1"
|
||
% You will get this error if a function is defined as \var{forward} twice.
|
||
% Or it is once in the \var{interface} section, and once as a \var{forward}
|
||
% declaration in the \var{implmentation} section.
|
||
parser_e_not_external_and_export=03121_E_No se pueden usar ambos EXPORT y EXTERNAL
|
||
% These two procedure directives are mutually exclusive
|
||
parser_w_not_supported_for_inline=03123_W_"$1" aún no soportado en procedimientos/funciones inline
|
||
% Inline procedures don't support this declaration.
|
||
parser_w_inlining_disabled=03124_W_Inlining deshabilitado
|
||
% Inlining of procedures is disabled.
|
||
parser_i_writing_browser_log=03125_I_Escribiendo Browser log $1
|
||
% When information messages are on, the compiler warns you when it
|
||
% writes the browser log (generated with the \var{\{\$Y+ \}} switch).
|
||
parser_h_maybe_deref_caret_missing=03126_H_podría ser que falte la de-referencia del puntero
|
||
% The compiler thinks that a pointer may need a dereference.
|
||
parser_f_assembler_reader_not_supported=03127_F_Lector del ensamblador seleccionado no soportado
|
||
% The selected assembler reader (with \var{\{\$ASMMODE xxx\}} is not
|
||
% supported. The compiler can be compiled with or without support for a
|
||
% particular assembler reader.
|
||
parser_e_proc_dir_conflict=03128_E_Directiva de procedimiento "$1" causa conflicto con otras directivas
|
||
% You specified a procedure directive that conflicts with other directives.
|
||
% for instance \var{cdecl} and \var{pascal} are mutually exclusive.
|
||
parser_e_call_convention_dont_match_forward=03129_E_La convencion de llamada actual no concuerda con la definida anteriormente
|
||
% This error happens when you declare a function or procedure with
|
||
% e.g. \var{cdecl;} but omit this directive in the implementation, or vice
|
||
% versa. The calling convention is part of the function declaration, and
|
||
% must be repeated in the function definition.
|
||
parser_e_property_cant_have_a_default_value=03131_E_La propiedad no puede tener un valor por defecto
|
||
% Set properties or indexed properties cannot have a default value.
|
||
parser_e_property_default_value_must_const=03132_E_El valor por defecto de una propiedad tiene que ser constante
|
||
% The value of a \var{default} declared property must be known at compile
|
||
% time. The value you specified is only known at run time. This happens
|
||
% .e.g. if you specify a variable name as a default value.
|
||
parser_e_cant_publish_that=03133_E_El símbolo no puede ser published, solo puede ser una clase
|
||
% Only class type variables can be in a \var{published} section of a class
|
||
% if they are not declared as a property.
|
||
parser_e_cant_publish_that_property=03134_E_Este tipo de propiedad no puede ser published
|
||
% Properties in a \var{published} section cannot be array properties.
|
||
% they must be moved to public sections. Properties in a \var{published}
|
||
% section must be an ordinal type, a real type, strings or sets.
|
||
parser_e_empty_import_name=03136_E_Se requiere un nombre de importación
|
||
% Some targets need a name for the imported procedure or a \var{cdecl} specifier
|
||
parser_e_division_by_zero=03138_E_Division por cero
|
||
% There is a divsion by zero encounted
|
||
parser_e_invalid_float_operation=03139_E_Operacion de punto flotante no válida
|
||
% An operation on two real type values produced an overflow or a division
|
||
% by zero.
|
||
parser_e_array_lower_less_than_upper_bound=03140_E_Límite superior del rango es menor que el límite inferior
|
||
% The upper bound of a an array declaration is less than the lower bound and this
|
||
% is not possible
|
||
parser_w_string_too_long=03141_W_La cadena "$1" es mas larga que $2
|
||
% The size of the constant string is larger than the size you specified in
|
||
% string type definition
|
||
parser_e_string_larger_array=03142_E_La longitud de la cadena es mayor que el tamaño array de carácteres
|
||
% The size of the constant string is larger than the size you specified in
|
||
% the array[x..y] of char definition
|
||
parser_e_ill_msg_expr=03143_E_Expresión inválida tras la directiva de mensaje
|
||
% \fpc supports only integer or string values as message constants
|
||
parser_e_ill_msg_param=03144_E_Los méetodos de manejo de mensajes deben tener un único parámetro por referencia
|
||
% A method declared with the \var{message}-directive as message handler
|
||
% can take only one parameter which must be declared as call by reference
|
||
% Parameters are declared as call by reference using the \var{var}-directive
|
||
parser_e_duplicate_message_label=03145_E_Etiqueta de mensaje duplicada: "$1"
|
||
% A label for a message is used twice in one object/class
|
||
parser_e_self_in_non_message_handler=03146_E_Self solo puede ser un parámetro explícito en manejadores de mensajes
|
||
% The self parameter can only be passed explicitly to a method which
|
||
% is declared as message handler.
|
||
parser_e_threadvars_only_sg=03147_E_Threadvars sólo pueden ser globales o estáticos
|
||
% Threadvars must be static or global, you can't declare a thread
|
||
% local to a procedure. Local variables are always local to a thread,
|
||
% because every thread has it's own stack and local variables
|
||
% are stored on the stack
|
||
parser_f_direct_assembler_not_allowed=03148_F_Ensamblador directo no soportado para formato binario de salida
|
||
% You can't use direct assembler when using a binary writer, choose an
|
||
% other outputformat or use an other assembler reader
|
||
parser_w_no_objpas_use_mode=03149_W_No carges manuamente la unidad OBJPAS, usa \{\$mode objfpc\} o \{\$mode delphi\}
|
||
% You are trying to load the ObjPas unit manually from a uses clause. This is
|
||
% not a good idea. Use the \var{\{\$mode objfpc\}} or
|
||
% \var{\{\$mode delphi\}}
|
||
% directives which load the unit automatically
|
||
parser_e_no_object_override=03150_E_OVERRIDE no puede ser usado en objetos
|
||
% Override is not supported for objects, use \var{virtual} instead to override
|
||
% a method of a parent object
|
||
parser_e_cant_use_inittable_here=03151_E_Tipos de datos que requieran inicializacion/finalizacion no pueden ser usados en registros variables
|
||
% Some data type (e.g. \var{ansistring}) needs initialization/finalization
|
||
% code which is implicitly generated by the compiler. Such data types
|
||
% can't be used in the variant part of a record.
|
||
parser_e_resourcestring_only_sg=03152_E_Resourcestrings solo pueden ser globales o estáaticos
|
||
% Resourcestring can not be declared local, only global or using the static
|
||
% directive.
|
||
parser_e_exit_with_argument_not__possible=03153_E_Exit con parámetro no puede ser usado aquí
|
||
% an exit statement with an argument for the return value can't be used here, this
|
||
% can happen e.g. in \var{try..except} or \var{try..finally} blocks
|
||
parser_e_stored_property_must_be_boolean=03154_E_El tipo del símbolo en stored debe ser de tipo booleano
|
||
% If you specify a storage symbol in a property declaration, it must be of
|
||
% the type boolean
|
||
parser_e_ill_property_storage_sym=03155_E_Este símbolo no puede ser usado en storage para una propiedad
|
||
% You can't use this type of symbol as storage specifier in property
|
||
% declaration. You can use only methods with the result type boolean,
|
||
% boolean class fields or boolean constants
|
||
parser_e_only_publishable_classes_can__be_published=03156_E_Solo clases compiladas en $M+ pueden ser publicadas
|
||
% In the published section of a class can be only class as fields used which
|
||
% are compiled in \var{\{\$M+\}} or which are derived from such a class. Normally
|
||
% such a class should be derived from TPersitent
|
||
parser_e_proc_directive_expected=03157_E_Directiva de procedimiento esperada
|
||
% When declaring a procedure in a const block you used a ; after the
|
||
% procedure declaration after which a procedure directive must follow.
|
||
% Correct declarations are:
|
||
% \begin{verbatim}
|
||
% const
|
||
% p : procedure;stdcall=nil;
|
||
% p : procedure stdcall=nil;
|
||
% \end{verbatim}
|
||
parser_e_invalid_property_index_value=03158_E_El valor para el índice de una propiedad debe ser de tipo ordinal
|
||
% The value you use to index a property must be of an ordinal type, for
|
||
% example an integer or enumerated type.
|
||
parser_e_procname_to_short_for_export=03159_E_Nombre del procedimiento demasiado corto para ser exportado
|
||
% The length of the procedure/function name must be at least 2 characters
|
||
% long. This is because of a bug in dlltool which doesn't parse the .def
|
||
% file correct with a name of length 1.
|
||
parser_e_dlltool_unit_var_problem=03160_E_No se puede generar una entrada DEFFILE para las variables globales de la unidad
|
||
parser_e_dlltool_unit_var_problem2=03161_E_Compile sin la opcion -WD
|
||
% You need to compile this file without the -WD switch on the
|
||
% commandline
|
||
parser_f_need_objfpc_or_delphi_mode=03162_F_Se requiere el modo ObjFpc (-S2) o Delphi (-Sd) para compilar este módulo
|
||
% You need to use \{\$mode objfpc\} or \{\$mode delphi\} to compile this file.
|
||
% Or use the equivalent commandline switches -S2 or -Sd.
|
||
parser_e_no_export_with_index_for_target=03163_E_No se pueden exportar funciones o procedimientos por indice en $1
|
||
% Exporting of functions or procedures with a specified index is not
|
||
% supported on this target.
|
||
parser_e_no_export_of_variables_for_target=03164_E_Exportar variables no esta soportado en $1
|
||
% Exporting of variables is not supported on this target.
|
||
parser_e_improper_guid_syntax=03165_E_Sintaxis de GUID incorrecta
|
||
parser_w_interface_mapping_notfound=03168_W_No se encontro el procedimiento de nombre "$1" apropiado para implementar $2.$3
|
||
parser_e_interface_id_expected=03169_E_identificador de interfaz esperado
|
||
% This happens when the compiler scans a \var{class} declaration that contains
|
||
% \var{interface} function name mapping code like this:
|
||
% \begin{verbatim}
|
||
% type
|
||
% TMyObject = class(TObject, IDispatch)
|
||
% function IUnknown.QueryInterface=MyQueryInterface;
|
||
% ....
|
||
% \end{verbatim}
|
||
% and the \var{interface} before the dot not listed in the inheritance list.
|
||
parser_e_type_cant_be_used_in_array_index=03170_E_El tipo "$1" no puede ser usado como indice en arrays
|
||
% Types like \var{qword} or \var{int64} aren't allowed as array index type
|
||
parser_e_no_con_des_in_interfaces=03171_E_No se permiten constructores/destructores en interfaces
|
||
% Constructor and destructor declarations aren't allowed in interface
|
||
% In the most cases the method \var{QueryInterface} of \var{IUnknown} can
|
||
% be used to create a new interface.
|
||
parser_e_no_access_specifier_in_interfaces=03172_E_No se permiten especificadores de acceso en interfaces
|
||
% The access specifiers \var{public}, \var{private}, \var{protected} and
|
||
% \var{pusblished} can't be used in interfaces because all methods
|
||
% of an interfaces must be public.
|
||
parser_e_no_vars_in_interfaces=03173_E_Una interfaz no puede contener campos
|
||
% Declarations of fields aren't allowed in interfaces. An interface
|
||
% can contain only methods
|
||
parser_e_no_local_proc_external=03174_E_No se puede declarar un procedimiento local como externo
|
||
% Declaring local procedures as external is not possible. Local procedures
|
||
% get hidden parameters that will make the chance of errors very high
|
||
parser_w_skipped_fields_before=03175_W_Algunos campos anteriores a "$1" no fueron inicializados
|
||
% In Delphi mode, not all fields of a typed constant record have to be
|
||
% initialized, but the compiler warns you when it detects such situations.
|
||
parser_e_skipped_fields_before=03176_E_Algunos campos anteriores a "$1" no fueron inicializados
|
||
% In all syntax modes but Delphi mode, you can't leave some fields uninitialized
|
||
% in the middle of a typed constant record
|
||
parser_w_skipped_fields_after=03177_W_Algunos campos tras "$1" no fueron inicializados
|
||
% You can leave some fields at the end of a type constant record uninitialized
|
||
% (the compiler will initialize them to zero automatically). This may be the cause
|
||
% of subtle problems.
|
||
parser_e_varargs_need_cdecl_and_external=03178_E_Directiva VarArgs sólo es válida con CDecl o External
|
||
% The varargs directive can only be used with procedures or functions
|
||
% that are declared with \var{cdecl} and \var{external} directives. The varargs directive
|
||
% is only meant to provide a compatible interface to C functions like printf.
|
||
parser_e_self_call_by_value=03179_E_Self debe ser un parámetro normal por valor
|
||
% You can't declare self as a const or var parameter, it must always be
|
||
% a call-by-value parameter
|
||
parser_e_interface_has_no_guid=03180_E_La interfaz "$1" no tiene identificacion
|
||
% When you want to assign an interface to a constant, then the interface
|
||
% must have a GUID value set.
|
||
parser_e_illegal_field_or_method=03181_E_Campo de la clase o método desconocido "$1"
|
||
% Properties must refer to a field or method in the same class.
|
||
parser_w_proc_overriding_calling=03182_W_Varias convenciones de llamada especificadas, "$1" ignorado al especificar "$2"
|
||
% There are two directives in the procedure declaration that specify a calling
|
||
% convention. Only the last directive will be used
|
||
parser_e_no_procvarobj_const=03183_E_constantes con tipo de tipo Procedure/Function (...) of Object solo pueden ser inicializados a NIL
|
||
% You can't assign the address of a method to a typed constant which has a
|
||
% 'procedure of object' type, because such a constant requires two addresses:
|
||
% that of the method (which is known at compile time) and that of the object or
|
||
% class instance it operates on (which can not be known at compile time).
|
||
parser_e_default_value_only_one_para=03184_E_Sólo se puede asignar valor por defecto a un parámetro
|
||
parser_e_default_value_expected_for_para=03185_E_Parámetro por defecto requerido para "$1"
|
||
parser_w_unsupported_feature=03186_W_¡Uso de una caracteristica no soportada!
|
||
% You're trying to force the compiler into doing something it cannot do yet.
|
||
parser_h_c_arrays_are_references=03187_H_Arrays tipo C son pasados por referencia
|
||
% Any array passed to a C functions is passed
|
||
% by a pointer (i.e. by reference).
|
||
parser_e_C_array_of_const_must_be_last=03188_E_Array tipo C de const debe ser el ultimo parámetro
|
||
% You can not add any other argument after an \var{array of const} for
|
||
% \var{cdecl} functions, as the size pushed on stack for this argument is
|
||
% not known.
|
||
parser_h_type_redef=03189_H_Redefinición del tipo "$1"
|
||
% This is an indicator that a previously declared type is
|
||
% being redefined as something else. This may, or may not
|
||
% be, a cause for errors.
|
||
parser_w_cdecl_has_no_high=03190_W_Procedimientos y funciones declarados como cdecl no reciben de parámetro el límite superior
|
||
% Functions declared with cdecl modifier do not pass an extra implicit parameter.
|
||
parser_w_cdecl_no_openstring=03191_W_open strings no son soportados en funciones cdecl
|
||
% Openstring is not supported for cdecl'ared functions.
|
||
parser_e_initialized_not_for_threadvar=03192_E_No se pueden inicializar variables declaradas como threadvar
|
||
% Variables declared as threadvar can not be initialized with a default value.
|
||
% The variables will always be filled with zero at the start of a new thread.
|
||
parser_e_msg_only_for_classes=03193_E_La directiva Message sólo es valida en clases
|
||
% The message directive is only supported for Class types.
|
||
parser_e_procedure_or_function_expected=03194_E_Se esperaba un procedimiento o funcion
|
||
% A class method can only be specified for procedures and functions.
|
||
parser_e_illegal_calling_convention=03195_W_Directiva de convención de llama "$1" ignorada
|
||
% Some calling conventions are supported only by certain CPUs. I.e. most non-i386 ports support
|
||
% only the standard ABI calling convention of the CPU.
|
||
parser_e_no_object_reintroduce=03196_E_REINTRODUCE no puede ser utilizado en objetos
|
||
% \var{reintroduce} is not supported for objects.
|
||
parser_e_paraloc_only_one_para=03197_E_Cada parámetro debe tener su propia posición
|
||
% If locations for arguments are specified explicitly as it is required by
|
||
% some syscall conventions, each argument must have it's only location, things
|
||
% like \var{procedure p(i,j : longint 'r1');} aren't allowed
|
||
parser_e_paraloc_all_paras=03198_E_Cada parámetro debe tener su propia posición
|
||
% If one argument has an explicit argument location, all arguments of a procedure
|
||
% must have one.
|
||
parser_e_illegal_explicit_paraloc=03199_E_Localizacón en el segmento desconocida
|
||
% The location specified for an argument isn't recognized by the compiler
|
||
parser_e_32bitint_or_pointer_variable_expected=03200_E_Se esperaba una variable entera de 32 bits o un puntero
|
||
% The libbase for MorphOS/AmigaOS can be give only as \var{longint}, \var{dword} or any pointer variable.
|
||
parser_e_goto_outside_proc=03201_E_No se puede usar Goto para saltar a otro procedimiento
|
||
% It isn't allowed to use the \var{goto} statements referencing labels outside the
|
||
% current procedure. The following example shows the problem:
|
||
% \begin{verbatim}
|
||
% ...
|
||
% procedure p1;
|
||
% label
|
||
% l1;
|
||
%
|
||
% procedure p2;
|
||
% begin
|
||
% goto l1; // This goto ISN'T allowed
|
||
% end;
|
||
%
|
||
% begin
|
||
% p2
|
||
% l1:
|
||
% end;
|
||
% ...
|
||
%
|
||
% \end{verbatim}
|
||
parser_f_too_complex_proc=03202_F_Procedimiento demasiado complejo. Se requieren demasiados registros
|
||
% Your procedure body is too long for the compiler. You should split the
|
||
% procedure into multiple smaller procedures.
|
||
parser_e_illegal_expression=03203_E_Expresión inválida
|
||
% This can occur under many circumstances. Mostly when trying to evaluate
|
||
% constant expressions.
|
||
parser_e_invalid_integer=03204_E_La expresión no evalua un número entero
|
||
% You made an expression which isn't an integer, and the compiler expects the
|
||
% result to be an integer.
|
||
parser_e_invalid_qualifier=03205_E_calificador inválido
|
||
% One of the following is happening :
|
||
% \begin{itemize}
|
||
% \item You're trying to access a field of a variable that is not a record.
|
||
% \item You're indexing a variable that is not an array.
|
||
% \item You're dereferencing a variable that is not a pointer.
|
||
% \end{itemize}
|
||
parser_e_upper_lower_than_lower=03206_E_El limite superior especificado es menor que el inferior
|
||
% You are declaring a subrange, and the lower limit is higher than the high
|
||
% limit of the range.
|
||
parser_e_macpas_exit_wrong_param=03207_E_El parámetro de Exit debe ser el nombre del mismo procedimiento en el que está
|
||
% Non local exit is not allowed. This error occur only in mode MacPas.
|
||
parser_e_illegal_assignment_to_count_var=03208_E_Asignación inválida a la variable de bucle "$1"
|
||
% The type of a \var{for} loop variable must be an ordinal type.
|
||
% Loop variables cannot be reals or strings.
|
||
parser_e_no_local_var_external=03209_E_No se puede declarar una variable local como externa
|
||
% Declaring local variables as external is not allowed. Only global variables can reference
|
||
% to external variables.
|
||
parser_e_proc_already_external=03210_E_El procedimiento ya ha sido declarado como externo con anterioridad
|
||
% The procedure is already declared with the EXTERNAL directive in an interface or
|
||
% forward declaration.
|
||
parser_w_implicit_uses_of_variants_unit=03211_W_Uso implícito de la unidad Variants
|
||
% The Variant type is used in the unit without any used unit using the Variants unit. The
|
||
% compiler has implicitly added the Variants unit to the uses list. To remove this warning
|
||
% the Variants unit needs to be added to the uses statement.
|
||
parser_e_no_static_method_in_interfaces=03212_E_Clases y métodos estáticos no pueden ser utilizados en interfaces
|
||
% The specifier \var{class} and directive \var{static} can't be used in interfaces
|
||
% because all methods of an interfaces must be public.
|
||
parser_e_arithmetic_operation_overflow=03213_E_Desbordamiento en la operación aritmética
|
||
% An operation on two integers values produced an overflow
|
||
% \end{description}
|
||
#
|
||
# Type Checking
|
||
#
|
||
# 04049 is the last used one
|
||
#
|
||
% \section{Type checking errors}
|
||
% This section lists all errors that can occur when type checking is
|
||
% performed.
|
||
% \begin{description}
|
||
type_e_mismatch=04000_E_Los tipos no concuerdan
|
||
% This can happen in many cases:
|
||
% \begin{itemize}
|
||
% \item The variable you're assigning to is of a different type than the
|
||
% expression in the assignment.
|
||
% \item You are calling a function or procedure with parameters that are
|
||
% incompatible with the parameters in the function or procedure definition.
|
||
% \end{itemize}
|
||
type_e_incompatible_types=04001_E_Tipos incompatibles: se encontró "$1" esperado "$2"
|
||
% There is no conversion possible between the two types
|
||
% Another possiblity is that they are declared in different
|
||
% declarations:
|
||
% \begin{verbatim}
|
||
% Var
|
||
% A1 : Array[1..10] Of Integer;
|
||
% A2 : Array[1..10] Of Integer;
|
||
%
|
||
% Begin
|
||
% A1:=A2; { This statement gives also this error, it
|
||
% is due the strict type checking of pascal }
|
||
% End.
|
||
% \end{verbatim}
|
||
type_e_not_equal_types=04002_E_Los tipos $1 y $2 no concuerdan
|
||
% The types are not equal
|
||
type_e_type_id_expected=04003_E_Identificador de tipo esperado
|
||
% The identifier is not a type, or you forgot to supply a type identifier.
|
||
type_e_variable_id_expected=04004_E_Identificador de variable esperado
|
||
% This happens when you pass a constant to a routine (such as \var{Inc} var or \var{Dec})
|
||
% when it expects a variable. You can only pass variables as arguments to these functions.
|
||
type_e_integer_expr_expected=04005_E_expression entera esperada, pero se encontró "$1"
|
||
% The compiler expects an expression of type integer, but gets a different
|
||
% type.
|
||
type_e_boolean_expr_expected=04006_E_Expresion booleana esperada, pero se encontró "$1"
|
||
% The expression must be a boolean type, it should be return true or
|
||
% false.
|
||
type_e_ordinal_expr_expected=04007_E_Espresión ordinal esperada
|
||
% The expression must be of ordinal type, i.e., maximum a \var{Longint}.
|
||
% This happens, for instance, when you specify a second argument
|
||
% to \var{Inc} or \var{Dec} that doesn't evaluate to an ordinal value.
|
||
type_e_pointer_type_expected=04008_E_Se esperaba un tipo puntero, pero se encontró "$1"
|
||
% The variable or expression isn't of the type \var{pointer}. This
|
||
% happens when you pass a variable that isn't a pointer to \var{New}
|
||
% or \var{Dispose}.
|
||
type_e_class_type_expected=04009_E_Se esperaba un tipo de clase, pero se encontró "$1"
|
||
% The variable of expression isn't of the type \var{class}. This happens
|
||
% typically when
|
||
% \begin{enumerate}
|
||
% \item The parent class in a class declaration isn't a class.
|
||
% \item An exception handler (\var{On}) contains a type identifier that
|
||
% isn't a class.
|
||
% \end{enumerate}
|
||
type_e_cant_eval_constant_expr=04011_E_No se puede evaluar la espresión constante
|
||
% This error can occur when the bounds of an array you declared does
|
||
% not evaluate to ordinal constants
|
||
type_e_set_element_are_not_comp=04012_E_Elementos de sets incompatibles
|
||
% You are trying to make an operation on two sets, when the set element types
|
||
% are not the same. The base type of a set must be the same when taking the
|
||
% union
|
||
type_e_set_operation_unknown=04013_E_Operación no implementada para sets
|
||
% several binary operations are not defined for sets
|
||
% like div mod ** (also >= <= for now)
|
||
type_w_convert_real_2_comp=04014_W_Conversion automática de tipo de punto flotante a COMP el cual es un tipo entero
|
||
% An implicit type conversion from a real type to a \var{comp} is
|
||
% encountered. Since \var{comp} is a 64 bit integer type, this may indicate
|
||
% an error.
|
||
type_h_use_div_for_int=04015_H_usa DIV para tener un resultado entero
|
||
% When hints are on, then an integer division with the '/' operator will
|
||
% procuce this message, because the result will then be of type real
|
||
type_e_strict_var_string_violation=04016_E_Tipos de cadena no concuerdan por la presencia de la opción $V+
|
||
% When compiling in \var{\{\$V+\}} mode, the string you pass as a parameter
|
||
% should be of the exact same type as the declared parameter of the procedure.
|
||
type_e_succ_and_pred_enums_with_assign_not_possible=04017_E_No se permite el uso de Succ o Pred en enumeraciones que tienen valores asignados explícitamente
|
||
% When you declared an enumeration type which has assignments in it, as in C,
|
||
% like in the following:
|
||
% \begin{verbatim}
|
||
% Tenum = (a,b,e:=5);
|
||
% \end{verbatim}
|
||
% you cannot use the \var{Succ} or \var{Pred} functions on them.
|
||
type_e_cant_read_write_type=04018_E_No se puede leer o escribir variables de este tipo
|
||
% You are trying to \var{read} or \var{write} a variable from or to a
|
||
% file of type text, which doesn't support that. Only integer types,
|
||
% reals, pchars and strings can be read from/written to a text file.
|
||
% Booleans can only be written to text files.
|
||
type_e_no_readln_writeln_for_typed_file=04019_E_No se puede utilizar readln o writeln en ficheros con tipo
|
||
% \var{readln} and \var{writeln} are only allowed for text files.
|
||
type_e_no_read_write_for_untyped_file=04020_E_No se pueden usar read o write en ficheros sin tipo
|
||
% \var{read} and \var{write} are only allowed for text or typed files.
|
||
type_e_typeconflict_in_set=04021_E_El set contiene un elemento que no es de tipo compatible
|
||
% There is at least one set element which is of the wrong type, i.e. not of
|
||
% the set type.
|
||
type_w_maybe_wrong_hi_lo=04022_W_lo/hi(longint/dword) devuelve la parte superior/inferior de tipo word
|
||
% \fpc supports an overloaded version of \var{lo/hi} for \var{longint/dword/int64/qword}
|
||
% which returns the lower/upper word/dword of the argument. TP always uses
|
||
% a 16 bit \var{lo/hi} which returns always bits 0..7 for \var{lo} and the
|
||
% bits 8..15 for \var{hi}. If you want the TP behavior you have
|
||
% to type cast the argument to \var{word/integer}
|
||
type_e_integer_or_real_expr_expected=04023_E_Espresión entera o real esperada
|
||
% The first argument to \var{str} must a real or integer type.
|
||
type_e_wrong_type_in_array_constructor=04024_E_Tipo "$1" erróneo en el constructor del array
|
||
% You are trying to use a type in an array constructor which is not
|
||
% allowed.
|
||
type_e_wrong_parameter_type=04025_E_Tipo incompatible para el parámetro número $1: Se recibió "$2", cuando se esperaba "$3"
|
||
% You are trying to pass an invalid type for the specified parameter.
|
||
type_e_no_method_and_procedure_not_compatible=04026_E_Variables de tipo método y procedimiento no son compatibles entre si
|
||
% You can't assign a method to a procedure variable or a procedure to a
|
||
% method pointer.
|
||
type_e_wrong_math_argument=04027_E_Constante pasada a la función matematica interna no válida
|
||
% The constant argument passed to a ln or sqrt function is out of
|
||
% the definition range of these functions.
|
||
type_e_no_addr_of_constant=04028_E_No se puede obtener una dirección de una constante
|
||
% It is not possible to get the address of a constant, because they
|
||
% aren't stored in memory, you can try making it a typed constant.
|
||
type_e_argument_cant_be_assigned=04029_E_No se puede asignar un valor al parámetro
|
||
% Only expressions which can be on the left side of an
|
||
% assignment can be passed as call by reference argument
|
||
% Remark: Properties can be only
|
||
% used on the left side of an assignment, but they cannot be used as arguments
|
||
type_e_cannot_local_proc_to_procvar=04030_E_No se puede asignar un prodecimiento o funcion local a una variable
|
||
% It's not allowed to assign a local procedure/function to a
|
||
% procedure variable, because the calling of local procedure/function is
|
||
% different. You can only assign local procedure/function to a void pointer.
|
||
type_e_no_assign_to_addr=04031_E_No se puede asignar un valor a una dirección
|
||
% It is not allowed to assign a value to an address of a variable,constant,
|
||
% procedure or function. You can try compiling with -So if the identifier
|
||
% is a procedure variable.
|
||
type_e_no_assign_to_const=04032_E_No se pueden asignar valores a variables constantes
|
||
% It's not allowed to assign a value to a variable which is declared
|
||
% as a const. This is normally a parameter declared as const, to allow
|
||
% changing the value make the parameter as a value parameter or a var.
|
||
type_e_array_required=04033_E_Se requiere un array para usar [ ]
|
||
% If you are accessing a variable using an index '[<x>]' then
|
||
% the type must be an array. In FPC mode also a pointer is allowed.
|
||
type_e_interface_type_expected=04034_E_Se esperaba "interface" pero se encontró "$1"
|
||
type_w_mixed_signed_unsigned=04035_W_Operaciones mezclando enteros de 32 bits con signo son convertidas a 64 bits
|
||
% If you divide (or calculate the modulus of) a signed expression by a longword (or vice versa),
|
||
% or if you have overflow and/or range checking turned on and use an arithmetic
|
||
% expression (+, -, *, div, mod) in which both signed numbers and longwords appear,
|
||
% then everything has to be evaluated in 64bit which is slower than normal
|
||
% 32bit arithmetic. You can avoid this by typecasting one operand so it
|
||
% matches the resulttype of the other one.
|
||
type_w_mixed_signed_unsigned2=04036_W_Mezclar operando con signo y sin signo aqui puede causar errores de comprobación de rango
|
||
% If you use a binary operator (and, or, xor) and one of
|
||
% the operands is a longword while the other one is a signed expression, then,
|
||
% if range checking is turned on, you may get a range check error because in
|
||
% such a case both operands are converted to longword before the operation is
|
||
% carried out. You can avoid this by typecasting one operand so it
|
||
% matches the resulttype of the other one.
|
||
type_e_typecast_wrong_size_for_assignment=04037_E_La conversión de tipos ($1 -> $2) en la asignación tiene diferentes tamaños
|
||
% Type casting to a type with a different size is not allowed when the variable is
|
||
% used for assigning.
|
||
type_e_array_index_enums_with_assign_not_possible=04038_E_No se pueden usar enums con asignaciones como indices de arrays
|
||
% When you declared an enumeration type which has assignments in it, as in C,
|
||
% like in the following:
|
||
% \begin{verbatim}
|
||
% Tenum = (a,b,e:=5);
|
||
% \end{verbatim}
|
||
% you cannot use it as index of an array.
|
||
type_e_classes_not_related=04039_E_Las clases u objetos "$1" y "$2" no están relacionados
|
||
% There is a typecast from one class or object to another while the class/object
|
||
% are not related. This will probably lead to errors
|
||
type_w_classes_not_related=04040_W_Los tipos de clases "$1" y "$2" no están relacionados
|
||
% There is a typecast from one class or object to another while the class/object
|
||
% are not related. This will probably lead to errors
|
||
type_e_class_or_interface_type_expected=04041_E_Se esperaba una clase o interfaz, pero se encotró "$1"
|
||
type_e_type_is_not_completly_defined=04042_E_El tipo "$1" no esta definido completamente aún
|
||
type_w_string_too_long=04043_W_La cadena contiene mas caracteres que los admitidos por una cadena corta
|
||
% The size of the constant string, which is assigned to a shortstring,
|
||
% is longer than the maximum size of the shortstring
|
||
type_w_signed_unsigned_always_false=04044_W_La comparación es siempre falsa debido a los rangos de los valores
|
||
% There is a comparison between an unsigned value and a signed constant which is
|
||
% less than zero. Because of type promotion, the statement will always evaluate to
|
||
% false. Exlicitly typecast the constant to the correct range to avoid this problem.
|
||
type_w_signed_unsigned_always_true=04045_W_La comparación es siempre verdadera debido a los rangos de los valores
|
||
% There is a comparison between an unsigned value and a signed constant which is
|
||
% less than zero. Because of type promotion, the statement will always evaluate to
|
||
% true. Exlicitly typecast the constant to the correct range to avoid this problem.
|
||
type_w_instance_with_abstract=04046_W_Constuyendo un objeto de clase "$1" que contiene métodos abstractos
|
||
% An instance of a class is created which contains non-implemented abstract
|
||
% methods. This will probably lead to a runtime error 211 in the code if that
|
||
% routine is ever called. All abstract methods should be overriden.
|
||
type_h_in_range_check=04047_H_El operando a la izquierda de IN debe ser de tamaño un byte
|
||
% The left operand of the \var{in} operator is not an ordinal or enumeration which fits
|
||
% within 8-bits, this may lead to range check errors. The \var{in} operator
|
||
% currently only supports a left operand which fits within a byte. In the case of
|
||
% enumerations, the size of an element of an enumeration can be controlled with
|
||
% the \var{\{\$PACKENUM\}} or \var{\{\$Zn\}} switches.
|
||
type_w_smaller_possible_range_check=04048_W_Diferencia del tamaño de los tipos puede causar pérdida de datos o errores de comprobación de rango
|
||
% There is an assignment to a smaller type than the source type. This means that
|
||
% this may cause a range-check error, or may lead to possible loss of data.
|
||
type_h_smaller_possible_range_check=04049_H_Diferencia del tamaño de los tipos puede causar pérdida de datos o errores de comprobación de rango
|
||
% There is an assignment to a smaller type than the source type. This means that
|
||
% this may cause a range-check error, or may lead to possible loss of data.
|
||
type_e_cant_take_address_of_abstract_method=04050_E_No se puede obtener la dirección de un método abstracto
|
||
% An abstract method has no body, so the address of an abstract method can't be taken.
|
||
type_e_operator_not_allowed=04051_E_El operador no es aplicable con los operandos especificados
|
||
% You are trying an operator that is not available for the type of the
|
||
% operands
|
||
type_e_constant_expr_expected=04052_E_Se esperaba una expresió constante
|
||
% The compiler expects an constant expression, but gets a variable expression.
|
||
type_e_operator_not_supported_for_types=04053_E_La operacion "$1" no está soportada para los tipos "$2" y "$3"
|
||
% The operation is not allowed for the supplied types
|
||
type_e_illegal_type_conversion=04054_E_No es posible realizar una conversión de "$1" a "$2"
|
||
% When doing a type-cast, you must take care that the sizes of the variable and
|
||
% the destination type are the same.
|
||
type_h_pointer_to_longint_conv_not_portable=04055_H_La conversion entre punteros y ordinales no es portable
|
||
% If you typecast a pointer to a longint (or vice-versa), this code will not compile
|
||
% on a machine using 64-bit for pointer storage.
|
||
type_w_pointer_to_longint_conv_not_portable=04056_W_La conversion entre punteros y ordinales no es portable
|
||
% If you typecast a pointer to a ordinal type of a different size (or vice-versa), this can
|
||
% cause problems. This is a warning to help finding the 32bit specific code where cardinal/longint is used
|
||
% to typecast pointers to ordinals. A solution is to use the ptrint/ptruint types instead.
|
||
type_e_cant_choose_overload_function=04057_E_No se pudo determinar que funcion sobrecargada llamar
|
||
% You're calling overloaded functions with a parameter that doesn't correspond
|
||
% to any of the declared function parameter lists. e.g. when you have declared
|
||
% a function with parameters \var{word} and \var{longint}, and then you call
|
||
% it with a parameter which is of type \var{integer}.
|
||
type_e_illegal_count_var=04058_E_Variable de contador inválida
|
||
% The type of a \var{for} loop variable must be an ordinal type.
|
||
% Loop variables cannot be reals or strings.
|
||
% \end{description}
|
||
#
|
||
# Symtable
|
||
#
|
||
# 05055 is the last used one
|
||
#
|
||
% \section{Symbol handling}
|
||
% This section lists all the messages that concern the handling of symbols.
|
||
% This means all things that have to do with procedure and variable names.
|
||
% \begin{description}
|
||
sym_e_id_not_found=05000_E_Identificador no encontrado "$1"
|
||
% The compiler doesn't know this symbol. Usually happens when you misspel
|
||
% the name of a variable or procedure, or when you forgot to declare a
|
||
% variable.
|
||
sym_f_internal_error_in_symtablestack=05001_F_Error interno en SymTableStack()
|
||
% An internal error occurred in the compiler; If you encounter such an error,
|
||
% please contact the developers and try to provide an exact description of
|
||
% the circumstances in which the error occurs.
|
||
sym_e_duplicate_id=05002_E_Identificador duplicado "$1"
|
||
% The identifier was already declared in the current scope.
|
||
sym_h_duplicate_id_where=05003_H_El identificador ya está definido en $1 en la línea $2
|
||
% The identifier was already declared in a previous scope.
|
||
sym_e_unknown_id=05004_E_Identificador desconocido "$1"
|
||
% The identifier encountered has not been declared, or is used outside the
|
||
% scope where it is defined.
|
||
sym_e_forward_not_resolved=05005_E_Declaración posterior no solucionada "$1"
|
||
% This can happen in two cases:
|
||
% \begin{itemize}
|
||
% \item This happens when you declare a function (in the \var{interface} part, or
|
||
% with a \var{forward} directive, but do not implement it.
|
||
% \item You reference a type which isn't declared in the current \var{type}
|
||
% block.
|
||
% \end{itemize}
|
||
sym_e_error_in_type_def=05007_E_Error en definición de tipo
|
||
% There is an error in your definition of a new array type:
|
||
% \item One of the range delimiters in an array declaration is erroneous.
|
||
% For example, \var{Array [1..1.25]} will trigger this error.
|
||
sym_e_forward_type_not_resolved=05009_E_Tipo posterior no resuelto "$1"
|
||
% A symbol was forward defined, but no declaration was encountered.
|
||
sym_e_only_static_in_static=05010_E_Solo las variables estáticas pueden ser usadas en métodos estáticos o fuera de métodos
|
||
% A static method of an object can only access static variables.
|
||
sym_f_type_must_be_rec_or_class=05012_F_tipo record o class esperado
|
||
% The variable or expression isn't of the type \var{record} or \var{class}.
|
||
sym_e_no_instance_of_abstract_object=05013_E_No se permiten instancias de clases u objetos con un métodos abstractos
|
||
% You are trying to generate an instance of a class which has an abstract
|
||
% method that wasn't overridden.
|
||
sym_w_label_not_defined=05014_W_Etiqueta no definida "$1"
|
||
% A label was declared, but not defined.
|
||
sym_e_label_used_and_not_defined=05015_E_Etiqueta "$1" usada pero no definida
|
||
% A label was declared and used, but not defined.
|
||
sym_e_ill_label_decl=05016_E_Declaración inválida de la etiqueta
|
||
% This error should never happen; it occurs if a label is defined outside a
|
||
% procedure or function.
|
||
sym_e_goto_and_label_not_supported=05017_E_GOTO y LABEL no son soportados (debe ser habilitado con -Sg)
|
||
% You must compile a program which has \var{label}s and \var{goto} statements
|
||
% with the \var{-Sg} switch. By default, \var{label} and \var{goto} aren't
|
||
% supported.
|
||
sym_e_label_not_found=05018_E_Etiqueta no encontrada
|
||
% A \var{goto label} was encountered, but the label isn't declared.
|
||
sym_e_id_is_no_label_id=05019_E_el identificador no es una etiqueta
|
||
% The identifier specified after the \var{goto} isn't of type label.
|
||
sym_e_label_already_defined=05020_E_Etiqueta ya definida
|
||
% You are defining a label twice. You can define a label only once.
|
||
sym_e_ill_type_decl_set=05021_E_Definicion de tipo set inválida
|
||
% The declaration of a set contains an invalid type definition.
|
||
sym_e_class_forward_not_resolved=05022_E_Definición posterior de la clase "$1" no resuelta
|
||
% You declared a class, but you did not implement it.
|
||
sym_n_unit_not_used=05023_H_Unidad "$1" no utilizada en $2
|
||
% The unit referenced in the \var{uses} clause is not used.
|
||
sym_h_para_identifier_not_used=05024_H_Parámetro "$1" no usado
|
||
% The identifier was declared (locally or globally) but
|
||
% was not used (locally or globally).
|
||
sym_n_local_identifier_not_used=05025_N_Variable local no usada "$1"
|
||
% You have declared, but not used a variable in a procedure or function
|
||
% implementation.
|
||
sym_h_para_identifier_only_set=05026_H_Valor asignado a "$1" pero no utilizado
|
||
% The identifier was declared (locally or globally)
|
||
% set but not used (locally or globally).
|
||
sym_n_local_identifier_only_set=05027_N_Valor asignado a la variable local "$1" no utilizado
|
||
% The variable in a procedure or function
|
||
% implementation is declared, set but never used.
|
||
sym_h_local_symbol_not_used=05028_H_Símbolo local $1 "$2" no utilizado
|
||
% A local symbol is never used.
|
||
sym_n_private_identifier_not_used=05029_N_Campo privado $1.$2 no utilizado
|
||
sym_n_private_identifier_only_set=05030_N_Valor asignado al campo privado $1.$2 pero nunca es utilizado
|
||
sym_n_private_method_not_used=05031_N_Método privado $1.$2 no utilizado
|
||
sym_e_set_expected=05032_E_Tipo set esperado
|
||
% The variable or expression is not of type \var{set}. This happens in an
|
||
% \var{in} statement.
|
||
sym_w_function_result_not_set=05033_W_El resultado de la función puede no haber sido asignado
|
||
% You can get this warning if the compiler thinks that a function return
|
||
% value is not set. This will not be displayed for assembler procedures,
|
||
% or procedures that contain assembler blocks.
|
||
sym_w_wrong_C_pack=05034_W_El tipo "$1" no esta correctamente alineado para C
|
||
% Arrays with sizes not multiples of 4 will be wrongly aligned
|
||
% for C structures.
|
||
sym_e_illegal_field=05035_E_Identificador de campo de registro desconocido: "$1"
|
||
% The field doesn't exist in the record/object definition.
|
||
sym_w_uninitialized_local_variable=05036_W_La variable local "$1" no parace haber sido inicializada
|
||
% This message is displayed if the compiler thinks that a variable will
|
||
% be used (i.e. appears in the right-hand-side of an expression) when it
|
||
% was not initialized first (i.e. appeared in the left-hand side of an
|
||
% assigment)
|
||
sym_w_uninitialized_variable=05037_W_La variable "$1" no parece haber sido inicializada
|
||
% This message is displayed if the compiler thinks that a variable will
|
||
% be used (i.e. appears in the right-hand-side of an expression) when it
|
||
% was not initialized first (i.e. appeared in the left-hand side of an
|
||
% assigment)
|
||
sym_e_id_no_member=05038_E_El identificador "$1" no identifica ningún miembro
|
||
% This error is generated when an identifier of a record,
|
||
% field, or method is accessed while it is not defined.
|
||
sym_h_param_list=05039_H_Declaracion encontrada: $1
|
||
% You get this when you use the \var{-vh} switch. In case an overloaded
|
||
% procedure is not found, then all candidate overloaded procedures are
|
||
% listed, with their parameter lists.
|
||
sym_e_segment_too_large=05040_E_Segmento de datos demasiado grande
|
||
% You get this when you declare a data element whose size exceeds the
|
||
% prescribed limit (2 Gb on 80386+/68020+ processors)
|
||
sym_e_no_matching_implementation_found=05042_E_No se encontro una implementación para el método "$1" de la interfaz
|
||
% There was no matching method found which could implement the interface
|
||
% method. Check argument types and result type of the methods.
|
||
sym_w_deprecated_symbol=05043_W_Símbolo "$1" desaconsejado
|
||
% This means that a symbol (a variable, routine, etc...) which is
|
||
% declared as \var{deprecated} is used. Deprecated symbols may no longer
|
||
% be available in newer versions of the unit / library. Usage of this symbol
|
||
% should be avoided as much as possible.
|
||
sym_w_non_portable_symbol=05044_W_El símbolo "$1" no es portable
|
||
% This means that a symbol (a variable, routine, etc...) which is
|
||
% declared as \var{platform} is used. This symbol's value, usage
|
||
% and availability is platform specific and should not be used
|
||
% if the source code must be portable.
|
||
sym_w_non_implemented_symbol=05055_W_El símbolo "$1" no está implementado
|
||
% This means that a symbol (a variable, routine, etc...) which is
|
||
% declared as \var{unimplemented} is used. This symbol is defined,
|
||
% but is not yet implemented on this specific platform.
|
||
sym_e_cant_create_unique_type=05056_E_No se puede crear un tipo único a partir de este tipo
|
||
% Only simple types like ordinal, float and string types are supported when
|
||
% redefining a type with \var{type newtype = type oldtype;}.
|
||
sym_h_uninitialized_local_variable=05057_H_La variable local "$1" no parece haber sido inicializada
|
||
% This message is displayed if the compiler thinks that a variable will
|
||
% be used (i.e. appears in the right-hand-side of an expression) when it
|
||
% was not initialized first (i.e. appeared in the left-hand side of an
|
||
% assigment)
|
||
sym_h_uninitialized_variable=05058_H_La variable "$1" no parece haber sido inicializada
|
||
% This message is displayed if the compiler thinks that a variable will
|
||
% be used (i.e. appears in the right-hand-side of an expression) when it
|
||
% was not initialized first (i.e. appeared in the left-hand side of an
|
||
% assigment)
|
||
% \end{description}
|
||
#
|
||
# Codegenerator
|
||
#
|
||
# 06040 is the last used one
|
||
#
|
||
% \section{Code generator messages}
|
||
% This section lists all messages that can be displayed if the code
|
||
% generator encounters an error condition.
|
||
% \begin{description}
|
||
cg_e_parasize_too_big=06009_E_El tamaño de la lista de par metros excede 65535 bytes
|
||
% The I386 processor limits the parameter list to 65535 bytes (the \var{RET}
|
||
% instruction causes this)
|
||
cg_e_file_must_call_by_reference=06012_E_Los tipos File deben ser pasados por referencia
|
||
% You cannot specify files as value parameters, i.e. they must always be
|
||
% declared \var{var} parameters.
|
||
cg_e_cant_use_far_pointer_there=06013_E_El uso de punteros "far" no esta permitido aqií
|
||
% Free Pascal doesn't support far pointers, so you cannot take the address of
|
||
% an expression which has a far reference as a result. The \var{mem} construct
|
||
% has a far reference as a result, so the following code will produce this
|
||
% error:
|
||
% \begin{verbatim}
|
||
% var p : pointer;
|
||
% ...
|
||
% p:=@mem[a000:000];
|
||
% \end{verbatim}
|
||
cg_e_dont_call_exported_direct=06015_E_las funciones declaradas como EXPORT no pueden ser llamadas
|
||
% No longer in use.
|
||
cg_w_member_cd_call_from_method=06016_W_Posible llamada inválida de un constructor o destructor
|
||
% The compiler detected that a constructor or destructor is called within a
|
||
% a method. This will probably lead to problems, since constructors / destructors
|
||
% require parameters on entry.
|
||
cg_n_inefficient_code=06017_N_código ineficiente
|
||
% Your statement seems dubious to the compiler.
|
||
cg_w_unreachable_code=06018_W_El código no será ejecutado nunca
|
||
% You specified a construct which will never be executed. Example:
|
||
% \begin{verbatim}
|
||
% while false do
|
||
% begin
|
||
% {.. code ...}
|
||
% end;
|
||
% \end{verbatim}
|
||
cg_e_cant_call_abstract_method=06020_E_Los métodos abstractos no pueden ser llamados directamente
|
||
% You cannot call an abstract method directy, instead you must call a
|
||
% overriding child method, because an abstract method isn't implemented.
|
||
cg_d_register_weight=06027_DL_Registro $1 peso $2 $3
|
||
% Debugging message. Shown when the compiler considers a variable for
|
||
% keeping in the registers.
|
||
cg_d_stackframe_omited=06029_DL_Se omite generar stack frame
|
||
% Some procedure/functions do not need a complete stack-frame, so it is omitted.
|
||
% This message will be displayed when the {-vd} switch is used.
|
||
cg_e_unable_inline_object_methods=06031_E_Métodos de objetos o clases no pueden ser inline
|
||
% You cannot have inlined object methods.
|
||
cg_e_unable_inline_procvar=06032_E_Variables de procedimiento o función no pueden ser inline
|
||
% A procedure with a procedural variable call cannot be inlined.
|
||
cg_e_no_code_for_inline_stored=06033_E_No hay código almacenado para procedimientos inline
|
||
% The compiler couldn't store code for the inline procedure.
|
||
cg_e_can_access_element_zero=06035_E_No se puede acceder al elemento 0 de cadenas largas, use SetLength/Length
|
||
% You should use \var{setlength} to set the length of an ansi/wide/longstring
|
||
% and \var{length} to get the length of such a string types
|
||
cg_e_cannot_call_cons_dest_inside_with=06037_E_No se pueden llamar a constructores o destructores en with
|
||
% Inside a \var{with} clause you cannot call a constructor or destructor for the
|
||
% object you have in the \var{with} clause.
|
||
cg_e_cannot_call_message_direct=06038_E_No se pueden llamar a métodos manejadores de mensajes directamente
|
||
% A message method handler method cannot be called directly if it contains an
|
||
% explicit self argument
|
||
cg_e_goto_inout_of_exception_block=06039_E_Salto fuera de un bloque de excepción
|
||
% It is not allowed to jump in or outside of an exception block like \var{try..finally..end;}:
|
||
% \begin{verbatim}
|
||
% label 1;
|
||
%
|
||
% ...
|
||
%
|
||
% try
|
||
% if not(final) then
|
||
% goto 1; // this line will cause an error
|
||
% finally
|
||
% ...
|
||
% end;
|
||
% 1:
|
||
% ...
|
||
% \end{verbatim}
|
||
cg_e_control_flow_outside_finally=06040_E_No se admiten instrucciones de control de flujo en un bloque finally
|
||
% It isn't allowed to use the control flow statements \var{break},
|
||
% \var{continue} and \var{exit}
|
||
% inside a finally statement. The following example shows the problem:
|
||
% \begin{verbatim}
|
||
% ...
|
||
% try
|
||
% p;
|
||
% finally
|
||
% ...
|
||
% exit; // This exit ISN'T allowed
|
||
% end;
|
||
% ...
|
||
%
|
||
% \end{verbatim}
|
||
% If the procedure \var{p} raises an exception the finally block is
|
||
% executed. If the execution reaches the exit, it's unclear what to do:
|
||
% exiting the procedure or searching for another exception handler
|
||
cg_w_parasize_too_big=06041_W_El tamaño del parámetro excede el límite de algunas CPU
|
||
% This indicates that you are declaring more than 64K of parameters, which
|
||
% might not be supported on other processor targets.
|
||
cg_w_localsize_too_big=06042_W_El tamaño de las variables locales excede el límite de algunas CPU
|
||
% This indicates that you are declaring more than 32K of lcoal variables, which
|
||
% might not be supported on other processor targets.
|
||
cg_e_localsize_too_big=06043_E_El tamaño de las variables locales excede el límite de la CPU de destino
|
||
% This indicates that you are declaring more than 32K of lcoal variables, which
|
||
% is not supported by this processor.
|
||
cg_e_break_not_allowed=06044_E_BREAK no permitido aquí
|
||
% You're trying to use \var{break} outside a loop construction.
|
||
cg_e_continue_not_allowed=06045_E_CONTINUE no permitido aquí
|
||
% You're trying to use \var{continue} outside a loop construction.
|
||
% \end{description}
|
||
# EndOfTeX
|
||
|
||
#
|
||
# Assembler reader
|
||
#
|
||
# 07097 is the last used one
|
||
#
|
||
asmr_d_start_reading=07000_DL_Iniciando interpretado de ensamblador de estilo $1
|
||
% This informs you that an assembler block is being parsed
|
||
asmr_d_finish_reading=07001_DL_Finalizado interpretado de ensamblador de estilo $1
|
||
% This informs you that an assembler block has finished.
|
||
asmr_e_none_label_contain_at=07002_E_Una patrón que no es una etiqueta contiene @
|
||
% A identifier which isn't a label can't contain a @.
|
||
asmr_e_building_record_offset=07004_E_Error construyendo desplazamiento de registro (record)
|
||
% There has an error occured while building the offset of a record/object
|
||
% structure, this can happend when there is no field specified at all or
|
||
% an unknown field identifier is used.
|
||
asmr_e_offset_without_identifier=07005_E_OFFSET usado sin identificador
|
||
% You can only use OFFSET with an identifier. Other syntaxes aren't
|
||
% supported
|
||
asmr_e_type_without_identifier=07006_E_TYPE usado sin identificador
|
||
% You can only use TYPE with an identifier. Other syntaxes aren't
|
||
% supported
|
||
asmr_e_no_local_or_para_allowed=07007_E_No es posible usar una variable local o parámetro aquí
|
||
% You can't use a local variable or parameter here, mostly because the
|
||
% addressing of locals and parameters is done using the frame pointer register so the
|
||
% address can't be obtained directly.
|
||
asmr_e_need_offset=07008_E_Es necesario el uso de OFFSET aquí
|
||
% You need to use OFFSET <id> here to get the address of the identifier.
|
||
asmr_e_need_dollar=07009_E_Es necesario el uso de $ auqí
|
||
% You need to use $<id> here to get the address of the identifier.
|
||
asmr_e_cant_have_multiple_relocatable_symbols=07010_E_No es posible utilizar varios símbolos reubicables
|
||
% You can't have more than one relocatable symbol (variable/typed constant)
|
||
% in one argument.
|
||
asmr_e_only_add_relocatable_symbol=07011_E_Símbolos reubicables solo pueden ser añadidos
|
||
% Relocatable symbols (variable/typed constant) can't be used with other
|
||
% operators. Only addition is allowed.
|
||
asmr_e_invalid_constant_expression=07012_E_Espresió constante inválida
|
||
% There is an error in the constant expression.
|
||
asmr_e_relocatable_symbol_not_allowed=07013_E_Símbolo reubicable no permitido
|
||
% You can't use a relocatable symbol (variable/typed constant) here.
|
||
asmr_e_invalid_reference_syntax=07014_E_Sintaxis de referencia inválida
|
||
% There is an error in the reference.
|
||
asmr_e_local_para_unreachable=07015_E_No se puede llegar a $1 desde este código
|
||
% You can not read directly the value of local or para
|
||
% of a higher level in assembler code (except for
|
||
% local assembler code without parameter nor locals).
|
||
asmr_e_local_label_not_allowed_as_ref=07016_E_No está permitido el uso símbolos locales o etiquetas como referencias
|
||
% You can't use local symbols/labels as references
|
||
asmr_e_wrong_base_index=07017_E_Uso inválido de registros indice y base
|
||
% There is an error with the base and index register, they are
|
||
% probably incorrect
|
||
asmr_w_possible_object_field_bug=07018_W_Posible error en el manejo de campos de objetos
|
||
% Fields of objects or classes can be reached directly in normal or objfpc
|
||
% modes but TP and Delphi modes treat the field name as a simple offset.
|
||
asmr_e_wrong_scale_factor=07019_E_Factor de escala erróneo
|
||
% The scale factor given is wrong, only 1,2,4 and 8 are allowed
|
||
asmr_e_multiple_index=07020_E_Uso de multiples registros índice
|
||
% You are trying to use more than one index register
|
||
asmr_e_invalid_operand_type=07021_E_Tipo del operando no válido
|
||
% The operand type doesn't match with the opcode used
|
||
asmr_e_invalid_string_as_opcode_operand=07022_E_Cadena no vólida como operando de esta instrucción: $1
|
||
% The string specified as operand is not correct with this opcode
|
||
asmr_w_CODE_and_DATA_not_supported=07023_W_@CODE y @DATA no son soportados
|
||
% @CODE and @DATA are unsupported and are ignored.
|
||
asmr_e_null_label_ref_not_allowed=07024_E_Referencias a etiqueta nula no permitida
|
||
asmr_e_expr_zero_divide=07025_E_Division entre cero en el evaluador de ensamblador
|
||
% There is a division by zero in a constant expression
|
||
asmr_e_expr_illegal=07026_E_Expresión inválida
|
||
% There is an illegal expression in a constant expression
|
||
asmr_e_escape_seq_ignored=07027_E_Sequencia de escape ignorada: $1
|
||
% There is a C-styled string, but the escape sequence in the string
|
||
% is unknown, and is therefore ignored
|
||
asmr_e_invalid_symbol_ref=07028_E_Referencia a símbolo inválida
|
||
asmr_w_fwait_emu_prob=07029_W_Fwait puede causar problemas de emulación con emu387
|
||
asmr_w_fadd_to_faddp=07030_W_$1 sin operando interpretado como $1P
|
||
asmr_w_enter_not_supported_by_linux=07031_W_La instruccion ENTER no está soportada por el kernel de Linux
|
||
% ENTER instruction can generate a stack page fault that is not
|
||
% caught correctly by the i386 Linux page handler.
|
||
asmr_w_calling_overload_func=07032_W_Llamando a una funcion sobrecargada desde ensamblador
|
||
% There is a call to an overloaded method in the assembler block,
|
||
% this might be the sign there is a problem
|
||
asmr_e_unsupported_symbol_type=07033_E_Tipo de símbolo no soportado para el operando
|
||
asmr_e_constant_out_of_bounds=07034_E_Valor de la constante fuera de rango
|
||
asmr_e_error_converting_decimal=07035_E_Error convirtiendo decimal $1
|
||
% A constant decimal value does not have the correct syntax
|
||
asmr_e_error_converting_octal=07036_E_Error convirtiendo octal $1
|
||
% A constant octal value does not have the correct syntax
|
||
asmr_e_error_converting_binary=07037_E_Error convirtiendo binario $1
|
||
% A constant binary value does not have the correct syntax
|
||
asmr_e_error_converting_hexadecimal=07038_E_Error convirtiendo hexadecimal $1
|
||
% A constant hexadecimal value does not have the correct syntax
|
||
asmr_h_direct_global_to_mangled=07039_H_$1 traducido a $2
|
||
asmr_w_direct_global_is_overloaded_func=07040_W_$1 esta asociado a una función sobrecargada
|
||
asmr_e_cannot_use_SELF_outside_a_method=07041_E_No se puede usar SELF fuera de un método
|
||
% There is a reference to the \var{self} symbol while it is not
|
||
% allowed. \var{self} can only be referenced inside methods
|
||
asmr_e_cannot_use_OLDEBP_outside_nested_procedure=07042_E_No se puede usar OLDEBP fuera de un procedimiento anidado
|
||
% There is a reference to the \var{oldebp} symbol while it is not
|
||
% allowed. \var{oldebp} can only be referenced inside nested routines
|
||
asmr_e_void_function=07043_W_No es posible devolver un valor en procedimientos desde código asm
|
||
% Trying to return a value while in a procedure. A procedure
|
||
% does not have any return value
|
||
asmr_e_SEG_not_supported=07044_E_SEG no soportado
|
||
asmr_e_size_suffix_and_dest_dont_match=07045_E_No concuerdan el tamaño del prefijo y el del origen o destino
|
||
% The register size and the opcode size suffix don't match. This is
|
||
% probably an error in the assembler statement
|
||
asmr_w_size_suffix_and_dest_dont_match=07046_W_No concuerdan el tamaño del prefijo y el del origen o destino
|
||
% The register size and the opcode size suffix don't match. This is
|
||
% probably an error in the assembler statement
|
||
asmr_e_syntax_error=07047_E_Error de sintaxis de ensamblador
|
||
% There is an assembler syntax error
|
||
asmr_e_invalid_opcode_and_operand=07048_E_Combinación inválida de operacion y operandos
|
||
% The opcode cannot be used with this type of operand
|
||
asmr_e_syn_operand=07049_E_Error de sintaxis de ensamblador en operando
|
||
asmr_e_syn_constant=07050_E_Error de sintaxis de ensamblador en constante
|
||
asmr_e_invalid_string_expression=07051_E_Espresión de cadena noáv lida
|
||
asmr_w_const32bit_for_address=07052_W_constante con la direccion del símbolo $1 que no es un puntero
|
||
% A constant expression represents an address which does not fit
|
||
% into a pointer. The address is probably incorrect
|
||
asmr_e_unknown_opcode=07053_E_Instrucción $1 no reconocida
|
||
% This opcode is not known
|
||
asmr_e_invalid_or_missing_opcode=07054_E_Falta la instrucción o no es válida
|
||
asmr_e_invalid_prefix_and_opcode=07055_E_Combinación de prefijo y operación inválidos: $1
|
||
asmr_e_invalid_override_and_opcode=07056_E_Combinación de sobrecarga y operación inválidos: $1
|
||
asmr_e_too_many_operands=07057_E_Demasiados operandos en la línea
|
||
% There are too many operands for this opcode. Check your
|
||
% assembler syntax
|
||
asmr_w_near_ignored=07058_W_NEAR ignorado
|
||
asmr_w_far_ignored=07059_W_FAR ignorado
|
||
asmr_e_dup_local_sym=07060_E_Símbolo local duplicado $1
|
||
asmr_e_unknown_local_sym=07061_E_Símbolo local indefinido $1
|
||
asmr_e_unknown_label_identifier=07062_E_Identificador de etiqueta desconocido $1
|
||
asmr_e_invalid_register=07063_E_Nombre de registro incorrecto
|
||
% There is an unknown register name used as operand.
|
||
asmr_e_invalid_fpu_register=07064_E_Nombre de registro de punto flotante no válido
|
||
% There is an unknown register name used as operand.
|
||
asmr_w_modulo_not_supported=07066_W_Modulo no soportado
|
||
asmr_e_invalid_float_const=07067_E_Constante de punto flotante no válida $1
|
||
% The floating point constant declared in an assembler block is
|
||
% invalid.
|
||
asmr_e_invalid_float_expr=07068_E_Espresión de punto flotante no válida
|
||
% The floating point expression declared in an assembler block is
|
||
% invalid.
|
||
asmr_e_wrong_sym_type=07069_E_Tipo de símbolo erróneo
|
||
asmr_e_cannot_index_relative_var=07070_E_No se puede indexar una var. local o un parámetro con un registro
|
||
% Trying to index using a base register a symbol which is already relative
|
||
% to a register. This is not possible, and will probably lead to crashes.
|
||
asmr_e_invalid_seg_override=07071_E_Espresión reemplazo de segmento inválida
|
||
asmr_w_id_supposed_external=07072_W_Identificador $1 se supone externo
|
||
% There is a reference to an undefined symbol. This will not result
|
||
% in an error, since the symbol might be external, but may cause
|
||
% problems at link time if the symbol is not defined anywhere.
|
||
asmr_e_string_not_allowed_as_const=07073_E_Cadenas no permitidas como constantes
|
||
% Character strings are not allowed as constants.
|
||
asmr_e_no_var_type_specified=07074_E_No hay tipo de variable especificado
|
||
% The syntax expects a type idenfitifer after the dot, but
|
||
% none was found.
|
||
asmr_w_assembler_code_not_returned_to_text=07075_E_Código ensamblador no devuelto a sección de texto
|
||
% There was a directive in the assembler block to change sections,
|
||
% but there is a missing return to the text section at the end
|
||
% of the assembler block. This might cause errors during link time.
|
||
asmr_e_not_directive_or_local_symbol=07076_E_No es una directiva o un símbolo local $1
|
||
% This symbol is unknown.
|
||
asmr_w_using_defined_as_local=07077_E_Usando un nombre definido como una etiqueta local
|
||
asmr_e_dollar_without_identifier=07078_E_Tóken de dólar usado sin identificador
|
||
% A constant expression has an identifier which does not start with
|
||
% the $ symbol.
|
||
asmr_w_32bit_const_for_address=07079_W_Constante de 32 bits creada para la dirección
|
||
% A constant was used as an address. This is probably an error,
|
||
% since using absolute addresses will probably not work.
|
||
asmr_n_align_is_target_specific=07080_N_.align es dependiente de la plataforma, use .balign o .p2align
|
||
% Using the .align directive is platform specific, and its meaning will vary
|
||
% from one platform to another.
|
||
asmr_e_cannot_access_field_directly_for_parameters=07081_E_No se puede acceder directamente a los campos de los parámetros
|
||
% You should load the parameter first into a register and then access the
|
||
% fields using that register.
|
||
asmr_e_cannot_access_object_field_directly=07082_E_No se puede acceder directamente a los campos de objetos o clases
|
||
% You should load the self pointer first into a register and then access the
|
||
% fields using the register as base. By default the self pointer is available
|
||
% in the esi register on i386.
|
||
asmr_e_unable_to_determine_reference_size=07083_E_No se especificó un tamaño y no es posible determinar el tamaño del operando
|
||
% You should specify explicitly a size for the reference, because
|
||
% the compiler is unable to determine what size (byte,word,dword,etc.) it
|
||
% should use for the reference.
|
||
asmr_e_cannot_use_RESULT_here=07084_E_No se puede utilizar RESULT en esta función
|
||
% Some functions which return complex types cannot use the \var{result}
|
||
% keyword.
|
||
asmr_w_adding_explicit_args_fXX=07086_W_"$1" sin operando traducido como "$1 %st,%st(1)"
|
||
asmr_w_adding_explicit_first_arg_fXX=07087_W_"$1 %st(n)" traducido como "$1 %st,%st(n)"
|
||
asmr_w_adding_explicit_second_arg_fXX=07088_W_"$1 %st(n)" traducido como "$1 %st(n),%st"
|
||
asmr_e_invalid_char_smaller=07089_E_El carácter < no está permitido aquí
|
||
% The shift operator requires the << characters. Only one
|
||
% of those characters was found.
|
||
asmr_e_invalid_char_greater=07090_E_El carácter > no está permitido aqui
|
||
% The shift operator requires the >> characters. Only one
|
||
% of those characters was found.
|
||
asmr_w_align_not_supported=07093_W_ALIGN no es soportado
|
||
asmr_e_no_inc_and_dec_together=07094_E_Inc y Dec no pueden estar juntos en la misma instrucción
|
||
% Trying to use an increment and a decrement within the same
|
||
% opcode on the 680x0. This is impossible.
|
||
asmr_e_invalid_reg_list_in_movem=07095_E_Lista de registros inválida para movem
|
||
% Trying to use the \var{movem} opcode with invalid registers
|
||
% to save or restore.
|
||
asmr_e_invalid_reg_list_for_opcode=07096_E_Lista de registros inválida para la instrucción
|
||
asmr_e_higher_cpu_mode_required=07097_E_Se requiere un modo de CPU superior ($1)
|
||
% Trying to use an instruction which is not supported in the current
|
||
% cpu mode. Use a higher cpu generation to be able to use this
|
||
% opcode in your assembler block
|
||
asmr_w_unable_to_determine_reference_size_using_dword=07098_W_No se especificó el tamaño del operando y no pudo ser determinado. Se utilizará DWORD por defecto
|
||
% You should specify explicitly a size for the reference, because
|
||
% the compiler is unable to determine what size (byte,word,dword,etc.) it
|
||
% should use for the reference. This warning is only used in Delphi mode where
|
||
% it falls back to use DWORD as default.
|
||
asmr_e_illegal_shifterop_syntax=07099_E_Error de sintaxis tratando de interpretar un operando de desplazamiento
|
||
% ARM only; ARM assembler supports a so called shifter operand. The used syntax isn't
|
||
% a valid shifter operand. Example for an operation with shifter operand:
|
||
% \begin{verbatim}
|
||
% asm
|
||
% orr r2,r2,r2,lsl #8
|
||
% end;
|
||
% \end{verbatim}
|
||
#
|
||
# Assembler/binary writers
|
||
#
|
||
# 08018 is the last used one
|
||
#
|
||
asmw_f_too_many_asm_files=08000_F_Demasiados archivos de ensamblador abiertos
|
||
% With smartlinking enabled, there are too many assembler
|
||
% files generated. Disable smartlinking.
|
||
asmw_f_assembler_output_not_supported=08001_F_Salida a ensamblador seleccionada no soportada
|
||
asmw_f_comp_not_supported=08002_F_Comp no soportado
|
||
asmw_f_direct_not_supported=08003_F_Direct no soportado por escritores binarios
|
||
% Direct assembler mode is not supported for binary writers.
|
||
asmw_e_alloc_data_only_in_bss=08004_E_Sólo esta permitido alojar datos en la seccion bss
|
||
asmw_f_no_binary_writer_selected=08005_F_No hay seleccionado un escritor binario
|
||
asmw_e_opcode_not_in_table=08006_E_Asm: Opcode $1 no está en la tabla
|
||
asmw_e_invalid_opcode_and_operands=08007_E_Asm: $1 combinacion inválida de opcode y operandos
|
||
asmw_e_16bit_not_supported=08008_E_Asm: Referencias de 16 Bit no soportadas
|
||
asmw_e_invalid_effective_address=08009_E_Asm: Dirección efectiva no válida
|
||
asmw_e_immediate_or_reference_expected=08010_E_Asm: Inmediato o referencia esperado
|
||
asmw_e_value_exceeds_bounds=08011_E_Asm: $1 valor excede los límites $2
|
||
asmw_e_short_jmp_out_of_range=08012_E_Asm: Salto corto es fuera de rango $1
|
||
asmw_e_undefined_label=08013_E_Asm: Etiqueta no definida $1
|
||
asmw_e_comp_not_supported=08014_E_Asm: El tipo Comp no está soportado en esta plataforma
|
||
asmw_e_extended_not_supported=08015_E_Asm: El tipo Extended no está soportado en esta plataforma
|
||
asmw_e_duplicate_label=08016_E_Asm: Etiquita $1 duplicada
|
||
asmw_e_redefined_label=08017_E_Asm: Etiqueta $1 redefinida
|
||
asmw_e_first_defined_label=08018_E_Asm: Se definió por primera vez aquí
|
||
asmw_e_invalid_register=08019_E_Asm: Registro $1 inválido
|
||
|
||
#
|
||
# Executing linker/assembler
|
||
#
|
||
# 09034 is the last used one
|
||
#
|
||
# BeginOfTeX
|
||
%
|
||
% \section{Errors of assembling/linking stage}
|
||
% This section lists errors that occur when the compiler is processing the
|
||
% command line or handling the configuration files.
|
||
% \begin{description}
|
||
exec_w_source_os_redefined=09000_W_Sistema operativo de origen redefinido
|
||
exec_i_assembling_pipe=09001_I_Ensamblando (pipe) $1
|
||
exec_d_cant_create_asmfile=09002_E_No se puede crear fichero ensamblador $1
|
||
% The mentioned file can't be created. Check if you have got
|
||
% access permissions to create this file
|
||
exec_e_cant_create_objectfile=09003_E_No se puede crear fichero objeto: $1
|
||
% The mentioned file can't be created. Check if you've
|
||
% got access permissions to create this file
|
||
exec_e_cant_create_archivefile=09004_E_No se puede crear fichero de archivado: $1
|
||
% The mentioned file can't be created. Check if you've
|
||
% access permissions to create this file
|
||
exec_e_assembler_not_found=09005_E_Ensamblador $1 no encontrado, cambiando a ensamblado externo
|
||
exec_t_using_assembler=09006_T_Usando ensamblador: $1
|
||
exec_e_error_while_assembling=09007_E_Error mientras se ensamblaba, codigo de terminación $1
|
||
% There was an error while assembling the file using an external assembler.
|
||
% Consult the documentation of the assembler tool to find out more information
|
||
% on this error.
|
||
exec_e_cant_call_assembler=09008_E_No se pudo llamar al ensamblador, error $1. Cambiando a ensamblador externo
|
||
exec_i_assembling=09009_I_Ensamblando $1
|
||
exec_i_assembling_smart=09010_I_Assembling con enlazado inteligente $1
|
||
exec_w_objfile_not_found=09011_W_Objeto $1 no encontrado, el enlazado podria fallar!
|
||
% One of the object file is missing, and linking will probably fail.
|
||
% Check your paths.
|
||
exec_w_libfile_not_found=09012_W_Librería $1 no encontrada, el enlazado podria fallar!
|
||
% One of the library file is missing, and linking will probably fail.
|
||
% Check your paths.
|
||
exec_e_error_while_linking=09013_E_Error durante el enlazado
|
||
% Generic error while linking.
|
||
exec_e_cant_call_linker=09014_E_No se puede llamar al enlazador, cambiando a enlazado externo
|
||
exec_i_linking=09015_I_Enlazando $1
|
||
exec_e_util_not_found=09016_E_Utilidad $1 no encontrada, cambiando a enlazado externo
|
||
exec_t_using_util=09017_T_Utilizando utilidad $1
|
||
exec_e_exe_not_supported=09018_E_Creacion de ejecutables no soportado
|
||
exec_e_dll_not_supported=09019_E_Creacion de librerías dinámicas/compartidas no soportado
|
||
exec_i_closing_script=09020_I_Cerrando script $1
|
||
exec_e_res_not_found=09021_E_Compilador de recursos no encontrado, cambiando a modo externo
|
||
exec_i_compilingresource=09022_I_Compilando resource $1
|
||
exec_t_unit_not_static_linkable_switch_to_smart=09023_T_La unidad $1 no puede ser enlazada estáticamente, cambiando a enlazado inteligente
|
||
exec_t_unit_not_smart_linkable_switch_to_static=09024_T_La unidad $1 no puede ser enlazada inteligentemente, cambiando a enlazado estático
|
||
exec_t_unit_not_shared_linkable_switch_to_static=09025_T_La unidad $1 no admite enlazado compartido, cambiando a enlazado estático
|
||
exec_e_unit_not_smart_or_static_linkable=09026_E_La unidad $1 no puede ser enlazada estática o inteligentemente
|
||
exec_e_unit_not_shared_or_static_linkable=09027_E_La unidad $1 no admite enlazado compartido o estático
|
||
%\end{description}
|
||
# EndOfTeX
|
||
|
||
#
|
||
# Executable information
|
||
#
|
||
execinfo_f_cant_process_executable=09028_F_No se puede post-procesar el ejecutable $1
|
||
execinfo_f_cant_open_executable=09029_F_No se puede abrir el ejecutable $1
|
||
execinfo_x_codesize=09030_X_Tamaño de Código: $1 bytes
|
||
execinfo_x_initdatasize=09031_X_Tamaño de datos inicializados: $1 bytes
|
||
execinfo_x_uninitdatasize=09032_X_Tamaño de datos sin inicializar: $1 bytes
|
||
execinfo_x_stackreserve=09033_X_Espacio reservado para la pila: $1 bytes
|
||
execinfo_x_stackcommit=09034_X_Stack space commited: $1 bytes
|
||
|
||
#
|
||
# Unit loading
|
||
#
|
||
# 10041 is the last used one
|
||
#
|
||
# BeginOfTeX
|
||
% \section{Unit loading messages.}
|
||
% This section lists all messages that can occur when the compiler is
|
||
% loading a unit from disk into memory. Many of these messages are
|
||
% informational messages.
|
||
% \begin{description}
|
||
unit_t_unitsearch=10000_T_Buscando unidad: $1
|
||
% When you use the \var{-vt}, the compiler tells you where it tries to find
|
||
% unit files.
|
||
unit_t_ppu_loading=10001_T_Cargando PPU $1
|
||
% When the \var{-vt} switch is used, the compiler tells you
|
||
% what units it loads.
|
||
unit_u_ppu_name=10002_U_PPU Nombre: $1
|
||
% When you use the \var{-vu} flag, the unit name is shown.
|
||
unit_u_ppu_flags=10003_U_PPU Banderas: $1
|
||
% When you use the \var{-vu} flag, the unit flags are shown.
|
||
unit_u_ppu_crc=10004_U_PPU CRC: $1
|
||
% When you use the \var{-vu} flag, the unit CRC check is shown.
|
||
unit_u_ppu_time=10005_U_PPU Fecha: $1
|
||
% When you use the \var{-vu} flag, the time the unit was compiled is shown.
|
||
unit_u_ppu_file_too_short=10006_U_Fichero PPU demasiado corto
|
||
% The ppufile is too short, not all declarations are present.
|
||
unit_u_ppu_invalid_header=10007_U_Cabecera PPU inválida (no comienza por PPU)
|
||
% A unit file contains as the first three bytes the ascii codes of \var{PPU}
|
||
unit_u_ppu_invalid_version=10008_U_Versión $1 inválida
|
||
% This unit file was compiled with a different version of the compiler, and
|
||
% cannot be read.
|
||
unit_u_ppu_invalid_processor=10009_U_PPU está compilada para otro procesador
|
||
% This unit file was compiled for a different processor type, and
|
||
% cannot be read
|
||
unit_u_ppu_invalid_target=10010_U_PPU está compilada para otra plataforma
|
||
% This unit file was compiled for a different target, and
|
||
% cannot be read
|
||
unit_u_ppu_source=10011_U_Origen PPU: $1
|
||
% When you use the \var{-vu} flag, the unit CRC check is shown.
|
||
unit_u_ppu_write=10012_U_Escribiendo $1
|
||
% When you specify the \var{-vu} switch, the compiler will tell you where it
|
||
% writes the unit file.
|
||
unit_f_ppu_cannot_write=10013_F_No se puede escribir el fichero PPU
|
||
% An error occurred when writing the unit file.
|
||
unit_f_ppu_read_error=10014_F_Error leyendo fichero PPU
|
||
% This means that the unit file was corrupted, and contains invalid
|
||
% information. Recompilation will be necessary.
|
||
unit_f_ppu_read_unexpected_end=10015_F_Fin de fichero inesperado
|
||
% Unexpected end of file. This may mean that the PPU file is
|
||
% corrupted.
|
||
unit_f_ppu_invalid_entry=10016_F_Entrada inválida en fichero PPU: $1
|
||
% The unit the compiler is trying to read is corrupted, or generated with a
|
||
% newer version of the compiler.
|
||
unit_f_ppu_dbx_count_problem=10017_F_Problema en el contador PPU Dbx
|
||
% There is an inconsistency in the debugging information of the unit.
|
||
unit_e_illegal_unit_name=10018_E_Nombre de unidad inválido: $1
|
||
% The name of the unit does not match the file name.
|
||
unit_f_too_much_units=10019_F_Demasiades unidades
|
||
% \fpc has a limit of 1024 units in a program. You can change this behavior
|
||
% by changing the \var{maxunits} constant in the \file{fmodule.pas} file of the
|
||
% compiler, and recompiling the compiler.
|
||
unit_f_circular_unit_reference=10020_F_Referencia circular entre unidades $1 y $2
|
||
% Two units are using each other in the interface part. This is only allowed
|
||
% in the \var{implementation} part. At least one unit must contain the other one
|
||
% in the \var{implementation} section.
|
||
unit_f_cant_compile_unit=10021_F_No se puede compilar la unidad $1, no hay código fuente disponible
|
||
% A unit was found that needs to be recompiled, but no sources are
|
||
% available.
|
||
unit_f_cant_find_ppu=10022_F_No se puede encontrar la unidad $1
|
||
% You tried to use a unit of which the PPU file isn't found by the
|
||
% compiler. Check your configuration file for the unit paths
|
||
unit_w_unit_name_error=10023_W_La unidad $1 no pudo ser encontrada, pero $2 existe
|
||
unit_f_unit_name_error=10024_F_Se buscó la unidad $1 pero se encontró $2
|
||
% Dos truncation of 8 letters for unit PPU files
|
||
% may lead to problems when unit name is longer than 8 letters.
|
||
unit_w_switch_us_missed=10025_W_Compilar la unidad System requiere el conmutador -Us
|
||
% When recompiling the system unit (it needs special treatment), the
|
||
% \var{-Us} must be specified.
|
||
unit_f_errors_in_unit=10026_F_Hubo $1 errores compilando el modulo, parando
|
||
% When the compiler encounters a fatal error or too many errors in a module
|
||
% then it stops with this message.
|
||
unit_u_load_unit=10027_U_Cargado de $1 ($2) unidad $3
|
||
% When you use the \var{-vu} flag, which unit is loaded from which unit is
|
||
% shown.
|
||
unit_u_recompile_crc_change=10028_U_Recompilando $1, checksum cambiado por $2
|
||
unit_u_recompile_source_found_alone=10029_U_Recompilando $1, solo se encontró el código fuente
|
||
% When you use the \var{-vu} flag, these messages tell you why the current
|
||
% unit is recompiled.
|
||
unit_u_recompile_staticlib_is_older=10030_U_Recompilando unidad, la lib estática es más antigua que la ppu
|
||
% When you use the \var{-vu} flag, the compiler warns if the static library
|
||
% of the unit are older than the unit file itself.
|
||
unit_u_recompile_sharedlib_is_older=10031_U_Recompilando unidad, la lib compartida es más antigua que la ppu
|
||
% When you use the \var{-vu} flag, the compiler warns if the shared library
|
||
% of the unit are older than the unit file itself.
|
||
unit_u_recompile_obj_and_asm_older=10032_U_Recompilando unidad, obj y asm son más antiguos que ppu
|
||
% When you use the \var{-vu} flag, the compiler warns if the assembler or
|
||
% object file of the unit are older than the unit file itself.
|
||
unit_u_recompile_obj_older_than_asm=10033_U_Recompilando unidad, obj es más antiguo que asm
|
||
% When you use the \var{-vu} flag, the compiler warns if the assembler
|
||
% file of the unit is older than the object file of the unit.
|
||
unit_u_parsing_interface=10034_U_Interpretando interfaz de $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it starts
|
||
% parsing the interface part of the unit
|
||
unit_u_parsing_implementation=10035_U_Interpretando implementacion de $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it starts
|
||
% parsing the implementation part of the unit
|
||
unit_u_second_load_unit=10036_U_Segunda carga para la unidad $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it starts
|
||
% recompiling a unit for the second time. This can happend with interdepend
|
||
% units.
|
||
unit_u_check_time=10037_U_Chequeo de fichero PPU $1 fecha $2
|
||
% When you use the \var{-vu} flag, the compiler show the filename and
|
||
% date and time of the file which a recompile depends on
|
||
### The following two error msgs is currently disabled.
|
||
#unit_h_cond_not_set_in_last_compile=10038_H_Conditional $1 was not set at startup in last compilation of $2
|
||
#% when recompilation of an unit is required the compiler will check that
|
||
#% the same conditionals are set for the recompiliation. The compiler has
|
||
#% found a conditional that currently is defined, but was not used the last
|
||
#% time the unit was compiled.
|
||
#unit_h_cond_set_in_last_compile=10039_H_Conditional $1 was set at startup in last compilation of $2
|
||
#% when recompilation of an unit is required the compiler will check that
|
||
#% the same conditionals are set for the recompiliation. The compiler has
|
||
#% found a conditional that was used the last time the unit was compiled, but
|
||
#% the conditional is currently not defined.
|
||
unit_w_cant_compile_unit_with_changed_incfile=10040_W_No se pudo recompilar la unida $1, pero se encontraron ficheros de inclusió modificados
|
||
% A unit was found to have modified include files, but
|
||
% some source files were not found, so recompilation is impossible.
|
||
unit_h_source_modified=10041_H_El fichero $1 es mas moderno que la versión Release del archivo PPU $2
|
||
% A modified source file for a unit was found that was compiled with the
|
||
% release flag (-Ur). The unit will not implicitly be recompiled because
|
||
% this release flag is set.
|
||
unit_u_ppu_invalid_fpumode=10042_U_Se esta utilizando una unidad que no fue compilada con el modo de FPU correcto
|
||
% Trying to compile code while using units which were not compiled with
|
||
% the same floating point format mode. Either all code should be compiled
|
||
% with FPU emulation on, or with FPU emulation off.
|
||
unit_u_loading_interface_units=10043_U_Cargando unidades de interfaz de $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it starts
|
||
% loading the units defined in the interface part of the unit.
|
||
unit_u_loading_implementation_units=10044_U_Cargando unidades de implementación de $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it starts
|
||
% loading the units defined in the implementation part of the unit.
|
||
unit_u_interface_crc_changed=10045_U_CRC de la interfaz de la unidad $1 cambiado
|
||
% When you use the \var{-vu} flag, the compiler warns that it the
|
||
% CRC calculated for the interface has been changed after the implementation
|
||
% has been parsed.
|
||
unit_u_implementation_crc_changed=10046_U_CRC de la implementacion de la unidad $1 cambiado
|
||
% When you use the \var{-vu} flag, the compiler warns that it the
|
||
% CRC calculated has been changed after the implementation
|
||
% has been parsed.
|
||
unit_u_finished_compiling=10047_U_Finalizando compilado de la unidad $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% has finished compiling the unit.
|
||
unit_u_add_depend_to=10048_U_Añadida dependencia de $1 a $2
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% has added a dependency between the two units.
|
||
unit_u_no_reload_is_caller=10049_U_No hay recarga, es llamada de: $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% has will not reload the unit because it is the unit that wants
|
||
% to load this unit
|
||
unit_u_no_reload_in_second_compile=10050_U_No hay recarga, ya se esta en la segunda compilación de: $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% has will not reload the unit because it is already in a second recompile
|
||
unit_u_flag_for_reload=10051_U_Marcado para recarga: $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% has to reload the unit
|
||
unit_u_forced_reload=10052_U_Recarga forzada
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% has is reloading the unit because it was required
|
||
unit_u_previous_state=10053_U_Estado anterior de $1: $2
|
||
% When you use the \var{-vu} flag, the compiler shows the
|
||
% previous state of the unit
|
||
unit_u_second_compile_unit=10054_U_Ya se está compilando $1, estableciendo segunda compilación
|
||
% When you use the \var{-vu} flag, the compiler warns that it starts
|
||
% recompiling a unit for the second time. This can happend with interdepend
|
||
% units.
|
||
unit_u_loading_unit=10055_U_Cargando unidad $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it starts
|
||
% loading the unit.
|
||
unit_u_finished_loading_unit=10056_U_Carga de la unidad $1 completada
|
||
% When you use the \var{-vu} flag, the compiler warns that it finished
|
||
% loading the unit.
|
||
unit_u_registering_new_unit=10057_U_Registrando nueva unidad $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it has
|
||
% found a new unit and registers it in the internal lists.
|
||
unit_u_reresolving_unit=10058_U_Re-resolviendo unidad $1
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% has to recalculate the internal data of the unit
|
||
unit_u_skipping_reresolving_unit=10059_U_Saltando re-resolución de $1, aún se estan cargando las unidades utilizadas
|
||
% When you use the \var{-vu} flag, the compiler warns that it
|
||
% skips to recalculate the internal data of the unit because there
|
||
% is no data to recalculate
|
||
% \end{description}
|
||
# EndOfTeX
|
||
|
||
#
|
||
# Options
|
||
#
|
||
# 11039 is the last used one
|
||
#
|
||
option_usage=11000_$1 [opciones] <fichero_entrada> [opciones]
|
||
# BeginOfTeX
|
||
%
|
||
% \section{Command-line handling errors}
|
||
% This section lists errors that occur when the compiler is processing the
|
||
% command line or handling the configuration files.
|
||
% \begin{description}
|
||
option_only_one_source_support=11001_W_Solo es soportado un fichero fuente
|
||
% You can specify only one source file on the command line. The first
|
||
% one will be compiled, others will be ignored. This may indicate that
|
||
% you forgot a \var{'-'} sign.
|
||
option_def_only_for_os2=11002_W_Fichero DEF solo puede ser creado para OS/2
|
||
% This option can only be specified when you're compiling for OS/2
|
||
option_no_nested_response_file=11003_E_Ficheros de respuesta anidados no son soportados
|
||
% you cannot nest response files with the \var{@file} command-line option.
|
||
option_no_source_found=11004_F_No hay fichero fuente en la línea de comandos
|
||
% The compiler expects a source file name on the command line.
|
||
option_no_option_found=11005_N_No hay opciones en el archivo de configuración $1
|
||
% The compiler didn't find any option in that config file.
|
||
option_illegal_para=11006_E_Parámetro incorrecto: $1
|
||
% You specified an unknown option.
|
||
option_help_pages_para=11007_H_-? escribe las páginas de ayuda
|
||
% When an unknown option is given, this message is diplayed.
|
||
option_too_many_cfg_files=11008_F_Demasiados ficheros de configuración anidados
|
||
% You can only nest up to 16 config files.
|
||
option_unable_open_file=11009_F_Imposible abrir fichero $1
|
||
% The option file cannot be found.
|
||
option_reading_further_from=11010_D_Leyendo opciones adicionales de $1
|
||
% Displayed when you have notes turned on, and the compiler switches
|
||
% to another options file.
|
||
option_target_is_already_set=11011_W_Destino está ya puesto a: $1
|
||
% Displayed if more than one \var{-T} option is specified.
|
||
option_no_shared_lib_under_dos=11012_W_Librerías compartidas no soportadas en la plataforma DOS, regresando a estáticas
|
||
% If you specify \var{-CD} for the \dos platform, this message is displayed.
|
||
% The compiler supports only static libraries under \dos
|
||
option_too_many_ifdef=11013_F_demasiados IF(N)DEFs
|
||
% the \var{\#IF(N)DEF} statements in the options file are not balanced with
|
||
% the \var{\#ENDIF} statements.
|
||
option_too_many_endif=11014_F_demasiados ENDIFs
|
||
% the \var{\#IF(N)DEF} statements in the options file are not balanced with
|
||
% the \var{\#ENDIF} statements.
|
||
option_too_less_endif=11015_F_condicional abierto al final del fichero
|
||
% the \var{\#IF(N)DEF} statements in the options file are not balanced with
|
||
% the \var{\#ENDIF} statements.
|
||
option_no_debug_support=11016_W_La generación de información de depuración no es soportada por este ejecutable
|
||
% It is possible to have a compiler executable that doesn't support
|
||
% the generation of debugging info. If you use such an executable with the
|
||
% \var{-g} switch, this warning will be displayed.
|
||
option_no_debug_support_recompile_fpc=11017_H_Prueba recompilando con -dGDB
|
||
% It is possible to have a compiler executable that doesn't support
|
||
% the generation of debugging info. If you use such an executable with the
|
||
% \var{-g} switch, this warning will be displayed.
|
||
option_obsolete_switch=11018_E_Estas usando el conmutador obsoleto $1
|
||
% this warns you when you use a switch that is not needed/supported anymore.
|
||
% It is recommended that you remove the switch to overcome problems in the
|
||
% future, when the switch meaning may change.
|
||
option_obsolete_switch_use_new=11019_E_Estás usando el conmutador obsoleto $1, porfavor usa $2
|
||
% this warns you when you use a switch that is not supported anymore. You
|
||
% must now use the second switch instead.
|
||
% It is recommended that you change the switch to overcome problems in the
|
||
% future, when the switch meaning may change.
|
||
option_switch_bin_to_src_assembler=11020_N_Cambiando a ensamblador de escritura de código fuente por defecto
|
||
% this notifies you that the assembler has been changed because you used the
|
||
% -a switch which can't be used with a binary assembler writer.
|
||
option_incompatible_asm=11021_W_La salida de ensamblador "$1" no es compatible con "$2"
|
||
option_asm_forced=11022_W_Forzado el uso de ensamblador "$1"
|
||
% The assembler output selected can not generate
|
||
% object files with the correct format. Therefore, the
|
||
% default assembler for this target is used instead.
|
||
option_using_file=11026_T_Leyendo opciones del fichero $1
|
||
% Options are also read from this file
|
||
option_using_env=11027_T_Leyendo opciones del entorno $1
|
||
% Options are also read from this environment string
|
||
option_handling_option=11028_D_Procesando pción "$1"
|
||
% Debug info that an option is found and will be handled
|
||
option_help_press_enter=11029__*** presione retorno ***
|
||
option_start_reading_configfile=11030_H_Inicio de lectura del archivo de configuración $1
|
||
% Starting of config file parsing.
|
||
option_end_reading_configfile=11031_H_Fin de lectura del archivo de configuración $1
|
||
% End of config file parsing.
|
||
option_interpreting_option=11032_D_Interpretando opción "$1"
|
||
option_interpreting_firstpass_option=11036_D_Interpretando primera pasada de la opción "$1"
|
||
option_interpreting_file_option=11033_D_Interpretando opción de archivo "$1"
|
||
option_read_config_file=11034_D_Leyendo archivo de configuración "$1"
|
||
option_found_file=11035_D_encontrado nombre del archivo fuente "$1"
|
||
% Additional infos about options, displayed
|
||
% when you have debug option turned on.
|
||
option_code_page_not_available=11039_E_Código de página desconocido
|
||
%\end{description}
|
||
# EndOfTeX
|
||
|
||
#
|
||
# Logo (option -l)
|
||
#
|
||
option_logo=11023_[
|
||
Free Pascal Compiler version $FPCVERSION [$FPCDATE] for $FPCCPU
|
||
Copyright (c) 1993-2005 by Florian Klaempfl
|
||
]
|
||
|
||
#
|
||
# Info (option -i)
|
||
#
|
||
option_info=11024_[
|
||
Free Pascal Compiler versión $FPCVERSION
|
||
|
||
Fecha del Compilador : $FPCDATE
|
||
CPU de destino : $FPCCPU
|
||
|
||
Plataformas soportadas:
|
||
$OSTARGETS
|
||
|
||
Sets de instrucciones de la CPU soportados:
|
||
$INSTRUCTIONSETS
|
||
|
||
Sets de instrucciones de la FPU soportados:
|
||
$FPUINSTRUCTIONSETS
|
||
|
||
Este programa esta bajo la licencia GNU General Public Licence
|
||
Para mas informació lea COPYING.FPC
|
||
|
||
Para informar de errores, sugerencias, etc:
|
||
bugrep@freepascal.org
|
||
]
|
||
|
||
#
|
||
# Help pages (option -? and -h)
|
||
#
|
||
# The first character on the line indicates who will display this
|
||
# line, the current possibilities are :
|
||
# * = every target
|
||
# 3 = 80x86 targets
|
||
# 6 = 680x0 targets
|
||
# e = in extended debug mode only
|
||
# P = PowerPC targets
|
||
# S = Sparc targets
|
||
# V = Virtual machine targets
|
||
# The second character also indicates who will display this line,
|
||
# (if the above character was TRUE) the current possibilities are :
|
||
# * = everyone
|
||
# g = with GDB info supported by the compiler
|
||
# O = OS/2
|
||
# L = UNIX systems
|
||
# The third character represents the indentation level.
|
||
#
|
||
option_help_pages=11025_[
|
||
**0*_ponga + tras un conmutador booleano para activarlo, - para desactivarlo
|
||
**1a_el compilador no borra los ficheros de ensamblador generados
|
||
**2al_incluir los números de línea del codigo fuente en el archivo ensamblador
|
||
**2an_incluir la informacion de nodos en el archivo ensamblador generado
|
||
*L2ap_usar tuberías (pipes) en lugar de crear archivos de ensamblado temporales
|
||
**2ar_incluir reserva y liberació de registros en el archivo ensamblador
|
||
**2at_incluir informacion de reserva y liberación temporales en el archivo ensamblador
|
||
**1A<x>_formato de salida:
|
||
**2Adefault_usar ensamblador por defecto
|
||
3*2Aas_ensamblar usando GNU AS
|
||
3*2Anasmcoff_coff (Go32v2) usando Nasm
|
||
3*2Anasmelf_elf32 (Linux) usando Nasm
|
||
3*2Anasmwin32_objeto Win32 usando Nasm
|
||
3*2Anasmwdosx_objeto Win32/WDOSX usando Nasm
|
||
3*2Awasm_fichero obj usando Wasm (Watcom)
|
||
3*2Anasmobj_fichero obj usando Nasm
|
||
3*2Amasm_fichero obj usando Masm (Microsoft)
|
||
3*2Atasm_fichero obj usando Tasm (Borland)
|
||
3*2Aelf_elf32 (Linux) usando escritor interno
|
||
3*2Acoff_coff (Go32v2) usando escritor interno
|
||
3*2Apecoff_pecoff (Win32) usando escritor interno
|
||
4*2Aas_ensamblar usando GNU AS
|
||
6*2Aas_archivo o de Unix usando GNU AS
|
||
6*2Agas_ensamblador GNU Motorola
|
||
6*2Amit_Sintaxis MIT (GAS antiguo)
|
||
6*2Amot_Ensamblador Motorola estándar
|
||
A*2Aas_ensamblar usando GNU AS
|
||
P*2Aas_ensamblar usando GNU AS
|
||
S*2Aas_ensamblar usando GNU AS
|
||
**1b_generar informacion de navegado
|
||
**2bl_generar informació de símbolos locales
|
||
**1B_construir(build) todos los modulos
|
||
**1C<x>_opciones de generado de código:
|
||
**2Cc<x>_cambiar la convencion de llamada por defecto a <x>
|
||
**2CD_crear adicionalmente una librería dinámica (no soportado)
|
||
**2Ce_Compilar con opcodes de punto flotante emulados
|
||
**2Cf<x>_Cambiar el set de instrucciones de la FPU usado, fpc -i para posibles valores<x>
|
||
**2Cg_Generar código PIC
|
||
**2Ch<n>_<n> bytes heap (entre 1023 y 67107840)
|
||
**2Ci_Comprobación de E/S
|
||
**2Cn_omitir etapa de enlazado
|
||
**2Co_comprobar desbordamiento en operaciones de enteros
|
||
**2Cp<x>_Cambiar el set de instrucciones usado, fpc -i para posibles valores
|
||
**2Cr_comprobación de rango
|
||
**2CR_verificar validez de objetos de llamada
|
||
**2Cs<n>_definir el tamaño de la pila a <n>
|
||
**2Ct_comprobación de pila
|
||
**2CX_crear adicionalmente una librerí con enlazado inteligente
|
||
**1d<x>_define el símbol <x>
|
||
**1D_generar fichero DEF
|
||
**2Dd<x>_establece la descripción a <x>
|
||
**2Dv<x>_establece la version de la DLL a <x>
|
||
*O2Dw_Aplicación PM
|
||
**1e<x>_establecer ruta al ejecutable
|
||
**1E_igual que -Cn
|
||
**1F<x>_establecer ficheros y rutas:
|
||
**2Fa<x>[,y]_para hacer que el programa cargue las unidades <x> e [y] antes de procesar su uses
|
||
**2Fc<x>_establece el código de pagina de la entrada a <x>
|
||
**2FD<x>_establece la ruta donde buscar las utilidades del compilador
|
||
**2Fe<x>_redirige la salida de errores a <x>
|
||
**2FE<x>_establece la ruta de destino de exe/unidades a <x>
|
||
**2Fi<x>_añade <x> a las rutas de inclusión
|
||
**2Fl<x>_añade <x> a las rutas de librerías
|
||
**2FL<x>_usa <x> como enlazador dinámico
|
||
**2Fo<x>_añade <x> a las rutas de objetos
|
||
**2Fr<x>_load error message file <x>
|
||
**2Fu<x>_adds <x> a las rutas de unidades
|
||
**2FU<x>_establece la ruta de salida de unidades a <x>, reemplaza -FE anteriores
|
||
*g1g_generar información de depurado:
|
||
*g2gc_generar comprobación de punteros
|
||
*g2gd_usar dbx
|
||
*g2gg_usar gsym
|
||
*g2gh_usar unidad de trazado de memoria (para depurar pérdidas de memoria)
|
||
*g2gl_usar informacion de líneas de las unidades para la traza de ejecución (backtrace)
|
||
*g2gv_genera programas trazables con valgrind
|
||
*g2gw_generar información de depurado dwarf
|
||
**1i_información
|
||
**2iD_devuelve la fecha del compilador
|
||
**2iV_devuelve la versión del compilador
|
||
**2iSO_devuelve el SO del compilador
|
||
**2iSP_devuelve el procesador del compilador
|
||
**2iTO_devuelve el SO de destino
|
||
**2iTP_devuelve el procesador de destino
|
||
**1I<x>_añade <x> a las rutas de iclusión
|
||
**1k<x>_Pasar <x> al enlazador
|
||
**1l_mostrar logo
|
||
**1M<x>_establecer modo del lenguaje a <x>
|
||
**2Mfpc_dialecto de free pascal(default)
|
||
**2Mobjfpc_activar algunas extensiones de Delphi 2
|
||
**2Mdelphi_tratar de ser compatible con Delphi
|
||
**2Mtp_tratar de ser compatible con TP/BP 7.0
|
||
**2Mgpc_tratar de ser compatible con gpc
|
||
**2Mmacpas_tratar de ser compatible con dialectos de macintosh pascal
|
||
**1n_no leer la configuración por defecto
|
||
**1o<x>_cambiar el nombre del ejecutable producido a <x>
|
||
**1O<x>_optimizaciones:
|
||
3*2Og_generar código más pequeño
|
||
3*2OG_generar código más rápido (defecto)
|
||
**2Or_mantener algunas variables en registros
|
||
3*2Ou_activar optimizaciones inseguras (ver docs)
|
||
3*2O1_optimizaciones nivel 1 (optimizaciones rápidas)
|
||
3*2O2_optimizaciones nivel 2 (-O1 + optimizaciones más lentas)
|
||
3*2O3_optimizaciones nivel 3 (-O2 repetidamente, max 5 veces)
|
||
3*2Op<x>_procesador de destino:
|
||
3*3Op1_establecer procesador de destino a 386/486
|
||
3*3Op2_establecer procesador de destino a Pentium/PentiumMMX (tm)
|
||
3*3Op3_establecer procesador de destino a PPro/PII/c6x86/K6 (tm)
|
||
6*2Og_generar código más pequeño
|
||
6*2OG_generatr código más rápido (defecto)
|
||
6*2Ox_optimizar al máximo (AUN CON ERRORES!!!)
|
||
6*2O0_establecer procesador de destino a MC68000
|
||
6*2O2_establecer procesador de destino a MC68020+ (defecto)
|
||
**1pg_generar código de perfilado gprof (define FPC_PROFILE)
|
||
**1R<x>_estilo de lectura de ensamblador:
|
||
**2Rdefault_usar ensamblador por defecto
|
||
3*2Ratt_leer ensamblador estilo AT&T
|
||
3*2Rintel_leer ensamblador estilo Intel
|
||
6*2RMOT_leer ensamblador estilo motorola
|
||
**1S<x>_opciones de sintaxis:
|
||
**2S2_igual que -Mobjfpc
|
||
**2Sc_soportar operadores estilo C (*=,+=,/= and -=)
|
||
**2Sa_incluir código de aserción.
|
||
**2Sd_igual que -Mdelphi
|
||
**2Se<x>_opciones de error. <x> es una combinación de los siguientes:
|
||
**3*_<n> : detener el compilador tras <n> errores (por defecto 1)
|
||
**3*_w : detener también tras avisos
|
||
**3*_n : detener también tras notas
|
||
**3*_h : detener también tras consejos
|
||
**2Sg_permitir LABEL y GOTO
|
||
**2Sh_Usar cadenas largas (ansistrings)
|
||
**2Si_soportar INLINE estilo C++
|
||
**2SI<x>_establecer estilo de interfaz a <x>
|
||
**3SIcom_interfaces compatibles COM (defecto)
|
||
**3SIcorba_interfaces compatibles CORBA
|
||
**2Sm_soportar macros tipo C (global)
|
||
**2So_igual que -Mtp
|
||
**2Sp_igual que -Mgpc
|
||
**2Ss_el nombre del constructor debe ser init (el destructor debe ser done)
|
||
**2St_permitir la palabra reservada static en objetos
|
||
**1s_no llamar al ensamblador ni enlazador
|
||
**2sh_Generar script para enlazar en host
|
||
**2st_Generar script para enlazar en destino
|
||
**2sr_Saltar fase de reserva de registros (usar con -alr)
|
||
**1T<x>_Sistema operativo de destino:
|
||
3*2Temx_OS/2 usando EMX (incluyendo extensor EMX/RSX)
|
||
3*2Tfreebsd_FreeBSD
|
||
3*2Tgo32v2_Version 2 de DJ Delorie DOS extender
|
||
3*2Tlinux_Linux
|
||
3*2Tnetbsd_NetBSD
|
||
3*2Tnetware_Novell Netware Module (clib)
|
||
3*2Tnetwlibc_Novell Netware Module (libc)
|
||
3*2Topenbsd_OpenBSD
|
||
3*2Tos2_OS/2 / eComStation
|
||
3*2Tsunos_SunOS/Solaris
|
||
3*2Twatcom_extensor DOS compatible Watcom
|
||
3*2Twdosx_extensor WDOSX DOS
|
||
3*2Twin32_Windows 32 Bit
|
||
4*2Tlinux_Linux
|
||
6*2Tamiga_Commodore Amiga
|
||
6*2Tatari_Atari ST/STe/TT
|
||
6*2Tlinux_Linux-68k
|
||
6*2Tmacos_Macintosh m68k (no soportado)
|
||
6*2Tpalmos_PalmOS
|
||
A*2Tlinux_Linux
|
||
P*2Tdarwin_Darwin y MacOS X en PowerPC
|
||
P*2Tlinux_Linux en PowerPC
|
||
P*2Tmacos_MacOS (clásico) en PowerPC
|
||
P*2Tmorphos_MorphOS
|
||
S*2Tlinux_Linux
|
||
**1u<x>_elimina la definición del símbolo <x>
|
||
**1U_opciones de unidad:
|
||
**2Un_no comprobar el nombre de la unidad
|
||
**2Ur_generar unidades para distribución (release)
|
||
**2Us_compilar la unidad System
|
||
**1v<x>_Mostrar detalles. <x> es una combinación de las siguientes letras:
|
||
**2*_e : Mostrar errores (defecto) 0 : No mostrar nada (excepto errores)
|
||
**2*_w : Mostrar avisos u : Mostrar info. de la unidad
|
||
**2*_n : Mostrar notas t : Mostrar archivos usados / intentados
|
||
**2*_h : Mostrar consejos c : Mostrar condicionales
|
||
**2*_i : Mostrar info. general d : Mostrar info. de depurado
|
||
**2*_l : Mostrar num de lineas r : Modo compatible con Rhide/GCC
|
||
**2*_a : Mostrar todo x : Info. del ejecutable (Win32 solo)
|
||
**2*_v : escribe fpcdebug.txt con p : Escribir el árbol de parser en tree.log
|
||
**2*_ mucha informacón de depurado
|
||
3*1W<x>_opciones de Win32 o similares
|
||
3*2WB<x>_Establece la dirección hex de base a <x>
|
||
3*2WC_Especifica que la aplicación es de consola
|
||
3*2WD_Usa DEFFILE para exportar funciones de la DLL o EXE
|
||
3*2WF_Especifica aplicación de pantalla completa (OS/2 sólo)
|
||
3*2WG_Especifica que la aplicación es para entorno gráfico
|
||
3*2WN_No generar código de reubicación (necesario para depurar)
|
||
3*2WR_Generar código de reubicación
|
||
P*2WC_Especifica aplicación de colnsola (MacOS sólo)
|
||
P*2WG_Especifica aplicación gráfica (MacOS sólo)
|
||
P*2WT_Especifica aplicación de tipo herramienta (herramienta MPW, MacOS sólo)
|
||
**1X_opciones de ejecutable:
|
||
**2Xc_pasar --shared al enlazador (Unix sólo)
|
||
**2Xd_no utilizar la ruta de librería por defecto (necesario para compilación cruzada)
|
||
**2XD_tratar de enlazar dinámicamente (define FPC_LINK_DYNAMIC)
|
||
**2XP<x>_pone <x> delante de los nombres de binutils
|
||
**2Xr<x>_establece la ruta de librerías a <x> (necesario para compilación cruzada)
|
||
**2Xs_eliminar todos los símbolos del ejecutable
|
||
**2XS_tratar de enlazar estáticamente (defecto) (define FPC_LINK_STATIC)
|
||
**2Xt_enlazar con librerias estáticas (-static es pasado al enlazador)
|
||
**2XX_tratar de enlazar inteligentemente (define FPC_LINK_SMART)
|
||
**1*_
|
||
**1?_muestra esta ayuda
|
||
**1h_muestra esta ayuda sin esperas
|
||
]
|
||
|
||
#
|
||
# The End...
|