mirror of
				https://gitlab.com/freepascal.org/fpc/source.git
				synced 2025-10-31 21:09:38 +01:00 
			
		
		
		
	
		
			
				
	
	
		
			1938 lines
		
	
	
		
			105 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			1938 lines
		
	
	
		
			105 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| #
 | ||
| #   $Id$
 | ||
| #   This file is part of the Free Pascal Compiler
 | ||
| #   Copyright (c) 1998-2000 by the Free Pascal Development team
 | ||
| #
 | ||
| #   Dutch Language File for Free Pascal
 | ||
| #
 | ||
| #   See the file COPYING.FPC, included in this distribution,
 | ||
| #   for details about the copyright.
 | ||
| #
 | ||
| #   This program is distributed in the hope that it will be useful,
 | ||
| #   but WITHOUT ANY WARRANTY; without even the implied warranty of
 | ||
| #   MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
 | ||
| #
 | ||
| #
 | ||
| # The constants are build in the following order:
 | ||
| # <part>_<type>_<txtidentifier>
 | ||
| #
 | ||
| # <part> is the part of the compiler the message is used
 | ||
| #   asmr_     assembler parsing
 | ||
| #   asmw_     assembler writing/binary writers
 | ||
| #   unit_     unit handling
 | ||
| #   scan_     scanner
 | ||
| #   parser_   parser
 | ||
| #   type_     type checking
 | ||
| #   general_  general info
 | ||
| #   exec_     calls to assembler, linker, binder
 | ||
| #
 | ||
| # <type> the type of the message it should normally used for
 | ||
| #   f_   fatal error
 | ||
| #   e_   error
 | ||
| #   w_   warning
 | ||
| #   n_   note
 | ||
| #   h_   hint
 | ||
| #   i_   info
 | ||
| #   l_   linenumber
 | ||
| #   u_   used
 | ||
| #   t_   tried
 | ||
| #   m_   macro
 | ||
| #   p_   procedure
 | ||
| #   c_   conditional
 | ||
| #   d_   debug message
 | ||
| #   b_   display overloaded procedures
 | ||
| #   x_   executable informations
 | ||
| #
 | ||
| 
 | ||
| #
 | ||
| # Enkele punten om bij het vertalen in het achterhoofd te houden:
 | ||
| #
 | ||
| # - "Methoden" wordt vaak foutief als "methodes" geschreven.
 | ||
| # - "Typen" wordt vaak foutief als "types" geschreven.
 | ||
| # - "Illegal" wordt niet met "illegaal" vertaald, maar met "ongeldig".
 | ||
| #   Illegaal betekent onwettig in het Nederlands.
 | ||
| # - Zo wordt "execute" niet met "executeren" vertaalt maar met "uitvoeren".
 | ||
| #   Programma, hebt u nog een laatste wens voordat de trekker wordt
 | ||
| #       overgehaald?
 | ||
| # - In het Nederlands schrijft men woorden vaker aan elkaar dan in het
 | ||
| #   Engels: "compiler switch" (2 woorden) wordt "compileroptie" (1 woord).
 | ||
| #   Let ook op voorvoegingen: "Interface and implementation names" wordt:
 | ||
| #    "Interface- en implementatienamen" (streepje!)
 | ||
| # - Pas op met het vernederlandsen van Engelse woorden. Bijvoorbeeld
 | ||
| #   "identifieerder". Voor deze categorie woorden bestaat geen goede
 | ||
| #   vertaling. Iedereen die zo'n vernederlandsing ziet krijgt echter gelijk
 | ||
| #   een pijnscheut in zijn taalknobbel. Soms helpt een woordenboek, anders
 | ||
| #   is het beter om de engelse term te laten staan. Wat improvisatie helpt
 | ||
| #   soms ook, "symbool" is niet precies hetzelfde maar kan in dit geval
 | ||
| #   prima als vertaling gebruikt worden.
 | ||
| 
 | ||
| #
 | ||
| # General
 | ||
| #
 | ||
| # BeginOfTeX
 | ||
| % \section{General compiler messages}
 | ||
| % This section gives the compiler messages which are not fatal, but which
 | ||
| % display useful information. The number of such messages can be
 | ||
| % controlled with the various verbosity level \var{-v} switches.
 | ||
| % \begin{description}
 | ||
| general_t_compilername=01000_T_Gebruikte compiler: $1
 | ||
| % When the \var{-vt} switch is used, this line tells you what compiler
 | ||
| % is used.
 | ||
| general_d_sourceos=01001_D_Bronsysteem: $1
 | ||
| % When the \var{-vd} switch is used, this line tells you what the source
 | ||
| % operating system is.
 | ||
| general_i_targetos=01002_I_Doelsysteem: $1
 | ||
| % When the \var{-vd} switch is used, this line tells you what the target
 | ||
| % operating system is.
 | ||
| general_t_exepath=01003_T_Programmalocatie: $1
 | ||
| % When the \var{-vt} switch is used, this line tells you where the compiler
 | ||
| % looks for it's binaries.
 | ||
| general_t_unitpath=01004_U_Locatie units: $1
 | ||
| % When the \var{-vt} switch is used, this line tells you where the compiler
 | ||
| % looks for compiled units. You can set this path with the \var{-Fu}
 | ||
| general_t_includepath=01005_T_Locatie includes: $1
 | ||
| % When the \var{-vt} switch is used, this line tells you where the compiler
 | ||
| % looks for it's include files (files used in \var{\{\$I xxx\}} statements).
 | ||
| % You can set this path with the \var{-I} option.
 | ||
| general_t_librarypath=01006_T_Locatie bibliotheken: $1
 | ||
| % When the \var{-vt} switch is used, this line tells you where the compiler
 | ||
| % looks for the libraries. You can set this path with the \var{-Fl} option.
 | ||
| general_t_objectpath=01007_T_Locatie objectbestanden: $1
 | ||
| % When the \var{-vt} switch is used, this line tells you where the compiler
 | ||
| % looks for object files you link in (files used in \var{\{\$L xxx\}} statements).
 | ||
| % You can set this path with the \var{-Fo} option.
 | ||
| general_i_abslines_compiled=01008_I_$1 Regels gecompileerd, $2 sec.
 | ||
| % When the \var{-vi} switch is used, the compiler reports the number
 | ||
| % of lines compiled, and the time it took to compile them (real time,
 | ||
| % not program time).
 | ||
| general_f_no_memory_left=01009_F_Geen geheugen meer vrij
 | ||
| % The compiler doesn't have enough memory to compile your program. There are
 | ||
| % several remedies for this:
 | ||
| % \begin{itemize}
 | ||
| % \item If you're using the build option of the compiler, try compiling the
 | ||
| % different units manually.
 | ||
| % \item If you're compiling a huge program, split it up in units, and compile
 | ||
| % these separately.
 | ||
| % \item If the previous two don't work, recompile the compiler with a bigger
 | ||
| % heap (you can use the \var{-Ch} option for this, \seeo{Ch})
 | ||
| % \end{itemize}
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Scanner
 | ||
| #
 | ||
| % \section{Scanner messages.}
 | ||
| % This section lists the messages that the scanner emits. The scanner takes
 | ||
| % care of the lexical structure of the pascal file, i.e. it tries to find
 | ||
| % reserved words, strings, etc. It also takes care of directives and
 | ||
| % conditional compiling handling.
 | ||
| % \begin{description}
 | ||
| general_i_writingresourcefile=01010_I_Schrijven van resource string tabel bestand: $1
 | ||
| % This message is shown when the compiler writes the Resource String Table
 | ||
| % file containing all the resource strings for a program.
 | ||
| general_e_errorwritingresourcefile=01011_E_Schrijven van resource string tabel bestand: $1
 | ||
| % This message is shown when the compiler encountered an error when writing
 | ||
| % the Resource String Table file
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Scanner
 | ||
| #
 | ||
| % \section{Scanner messages.}
 | ||
| % This section lists the messages that the scanner emits. The scanner takes
 | ||
| % care of the lexical structure of the pascal file, i.e. it tries to find
 | ||
| % reserved words, strings, etc. It also takes care of directives and
 | ||
| % conditional compiling handling.
 | ||
| % \begin{description}
 | ||
| scan_f_end_of_file=02000_F_Onverwacht einde van bestand
 | ||
| % this typically happens in one of the following cases :
 | ||
| % \begin{itemize}
 | ||
| % \item The source file ends before the final \var{end.} statement. This
 | ||
| % happens mostly when the \var{begin} and \var{end} statements aren't
 | ||
| % balanced;
 | ||
| % \item An include file ends in the middle of a statement.
 | ||
| % \item A comment wasn't closed.
 | ||
| % \end{itemize}
 | ||
| scan_f_string_exceeds_line=02001_F_String langer dan regel
 | ||
| % You forgot probably to include the closing ' in a string, so it occupies
 | ||
| % multiple lines.
 | ||
| scan_f_illegal_char=02002_F_ongeldig teken
 | ||
| % An illegal character was encountered in the input file.
 | ||
| scan_f_syn_expected=02003_F_Taalfout: $2 verwacht in kolom $1
 | ||
| % This indicates that the compiler expected a different token than
 | ||
| % the one you typed. It can occur almost everywhere where you make a
 | ||
| % mistake against the pascal language.
 | ||
| scan_t_start_include_file=02004_T_Ingevoegd bestand $1 word geopend
 | ||
| % When you provide the \var{-vt} switch, the compiler tells you
 | ||
| % when it starts reading an included file.
 | ||
| scan_w_comment_level=02005_W_Commentaar van niveau $1 gevonden
 | ||
| % When the \var{-vw} switch is used, then the compiler warns you if
 | ||
| % it finds nested comments. Nested comments are not allowed in Turbo Pascal
 | ||
| % and can be a possible source of errors.
 | ||
| scan_n_far_directive_ignored=02006_N_$F directive (FAR) genegeerd
 | ||
| % The \var{FAR} directive is a 16-bit construction which is recorgnised
 | ||
| % but ignored by the compiler, since it produces 32 bit code.
 | ||
| scan_n_stack_check_global_under_linux=02007_N_Stapeloverloopcontrole is globaal onder linux
 | ||
| % Stack checking with the \var{-Cs} switch is ignored under \linux, since
 | ||
| % \linux does this for you. Only displayed when \var{-vn} is used.
 | ||
| scan_n_ignored_switch=02008_N_Genegeerde compileroptie $1
 | ||
| % With \var{-vn} on, the compiler warns if it ignores a switch
 | ||
| scan_w_illegal_switch=02009_W_Foutieve compileroptie $1
 | ||
| % You included a compiler switch (i.e. \var{\{\$... \}}) which the compiler
 | ||
| % doesn't know.
 | ||
| scan_w_switch_is_global=02010_W_Deze compileroptie heeft ook een globaal effect
 | ||
| % When \var{-vw} is used, the compiler warns if a switch is global.
 | ||
| scan_e_illegal_char_const=02011_E_Foutieve constante voor een karakter
 | ||
| % This happens when you specify a character with its ASCII code, as in
 | ||
| % \var{\#96}, but the number is either illegal, or out of range. The range
 | ||
| % is 1-255.
 | ||
| scan_f_cannot_open_input=02012_F_Kan bestand niet openen
 | ||
| % \fpc cannot find the program or unit source file you specified on the
 | ||
| % command line.
 | ||
| scan_f_cannot_open_includefile=02013_F_Kan ingevoerd bestand niet openen $1
 | ||
| % \fpc cannot find the source file you specified in a \var{\{\$include ..\}}
 | ||
| % statement.
 | ||
| scan_e_too_much_endifs=02014_E_Te veel $ENDIFs of $ELSEs
 | ||
| % Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced.
 | ||
| scan_w_only_pack_records=02015_W_Record velden kunnen op 1,2 of 4 bytes uitgelijnd worden.
 | ||
| % You are specifying the \var{\{\$PACKRECORDS n\} } with an illegal value for
 | ||
| % \var{n}. Only 1,2,4 or 16 are valid in this case.
 | ||
| scan_w_only_pack_enum=02016_W_Enumeraties kunnen alleen worden bewaard in 1,2 of 4 bytes
 | ||
| % You are specifying the \var{\{\$PACKENUM n\}} with an illegal value for
 | ||
| % \var{n}. Only 1,2 or 4 are valid in this case.
 | ||
| scan_e_endif_expected=02017_E_$ENDIF verwacht voor $1 op $2 $3
 | ||
| % Your conditional compilation statements are unbalanced.
 | ||
| scan_e_preproc_syntax_error=02018_E_Taalfout bij het compileren van een conditionele compilatie uitdrukking
 | ||
| % There is an error in the expression following the \var{\{\$if ..\}} compiler
 | ||
| % directive.
 | ||
| scan_e_error_in_preproc_expr=02019_E_Evalueren van een conditionele compilatie uitdrukking
 | ||
| % There is an error in the expression following the \var{\{\$if ..\}} compiler
 | ||
| % directive.
 | ||
| scan_w_macro_cut_after_255_chars=02020_W_Macro inhoud is afgekapt op 255 karakters voor evaluatie
 | ||
| % The contents of macros cannot be longer than 255 characters. This is a
 | ||
| % safety in the compiler, to prevent buffer overflows. This is shown as a
 | ||
| % warning, i.e. when the \var{-vw} switch is used.
 | ||
| scan_e_endif_without_if=02021_E_ENDIF zonder IF(N)DEF
 | ||
| % Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced.
 | ||
| scan_f_user_defined=02022_F_Gebruiker definitie: $1
 | ||
| % A user defined fatal error occurred. see also the \progref
 | ||
| scan_e_user_defined=02023_E_Gebruiker definitie: $1
 | ||
| % A user defined error occurred. see also the \progref
 | ||
| scan_w_user_defined=02024_W_Gebruiker definitie: $1
 | ||
| % A user defined warning occurred. see also the \progref
 | ||
| scan_n_user_defined=02025_N_Gebruiker definitie: $1
 | ||
| % A user defined note was encountered. see also the \progref
 | ||
| scan_h_user_defined=02026_H_Gebruiker definitie: $1
 | ||
| % A user defined hint was encountered. see also the \progref
 | ||
| scan_i_user_defined=02027_I_Gebruiker definitie: $1
 | ||
| % User defined information was encountered. see also the \progref
 | ||
| scan_e_keyword_cant_be_a_macro=02028_E_Sleutelwoord herdefinieren als macro heeft geen effect
 | ||
| % You cannot redefine keywords with macros.
 | ||
| scan_f_macro_buffer_overflow=02029_F_Macro buffer overflow bij lezen of expansie van macro
 | ||
| % Your macro or it's result  was too long for the compiler.
 | ||
| scan_w_macro_deep_ten=02030_W_Expansie van macro meer dan 16 niveaus diep, waarschijnlijk een recursieve macro
 | ||
| % When expanding a macro macros have been nested to a level of 16.
 | ||
| % The compiler will expand no further, since this may be a sign that
 | ||
| % recursion is used.
 | ||
| scan_e_wrong_styled_switch=02031_E_Compileroptie is niet toegestaan in (* ... *) commentaar
 | ||
| % Compiler switches should always be between \var{\{ \}} comment delimiters.
 | ||
| scan_d_handling_switch=02032_D_Behandel schakelaar "$1"
 | ||
| % When you set debugging info on (\var{-vd}) the compiler tells you when it
 | ||
| % is evaluating conditional compile statements.
 | ||
| scan_c_endif_found=02033_C_ENDIF $1 gevonden
 | ||
| % When you turn on conditional messages(\var{-vc}), the compiler tells you
 | ||
| % where it encounters conditional statements.
 | ||
| scan_c_ifdef_found=02034_C_IFDEF $1 gevonden, $2
 | ||
| % When you turn on conditional messages(\var{-vc}), the compiler tells you
 | ||
| % where it encounters conditional statements.
 | ||
| scan_c_ifopt_found=02035_C_IFOPT $1 gevonden, $2
 | ||
| % When you turn on conditional messages(\var{-vc}), the compiler tells you
 | ||
| % where it encounters conditional statements.
 | ||
| scan_c_if_found=02036_C_IF $1 gevonden, $2
 | ||
| % When you turn on conditional messages(\var{-vc}), the compiler tells you
 | ||
| % where it encounters conditional statements.
 | ||
| scan_c_ifndef_found=02037_C_IFNDEF $1 gevonden, $2
 | ||
| % When you turn on conditional messages(\var{-vc}), the compiler tells you
 | ||
| % where it encounters conditional statements.
 | ||
| scan_c_else_found=02038_C_ELSE $1 gevonden, $2
 | ||
| % When you turn on conditional messages(\var{-vc}), the compiler tells you
 | ||
| % where it encounters conditional statements.
 | ||
| scan_c_skipping_until=02039_C_Negeer tot...
 | ||
| % When you turn on conditional messages(\var{-vc}), the compiler tells you
 | ||
| % where it encounters conditional statements, and whether it is skipping or
 | ||
| % compiling parts.
 | ||
| scan_i_press_enter=02040_I_Druk <return> om verder te gaan
 | ||
| % When the \var{-vi} switch is used, the compiler stops compilation
 | ||
| % and waits for the \var{Enter} key to be pressed when it encounters
 | ||
| % a \var{\{\$STOP\}} directive.
 | ||
| scan_w_unsupported_switch=02041_W_Niet ondersteunde optie $1
 | ||
| % When warings are turned on (\var{-vw}) the compiler warns you about
 | ||
| % unsupported switches. This means that the switch is used in Delphi or
 | ||
| % Turbo Pascal, but not in \fpc
 | ||
| scan_w_illegal_directive=02042_W_Ongeldige compiler optie $1
 | ||
| % When warings are turned on (\var{-vw}) the compiler warns you about
 | ||
| % unrecognised switches. For a list of recognised switches, \progref
 | ||
| scan_t_back_in=02043_T_Terug in $1
 | ||
| % When you use (\var{-vt}) the compiler tells you when it has finished
 | ||
| % reading an include file.
 | ||
| %%% scan_w_unsupported_app_type=W_Applicatie type niet ondersteund: $1
 | ||
| %%% % You get this warning, ff you specify an unknown application type
 | ||
| %%% % with the directive \var{\{\$APPTYPE\}}
 | ||
| scan_w_unsupported_app_type=02044_W_Niet ondersteund programmatype: $1
 | ||
| % It is not possible to switch from one assembler reader to another
 | ||
| % inside an assmebler block. The new reader will be used for next
 | ||
| % assembler statement only.
 | ||
| scan_w_app_type_not_support=02045_W_$APPTYPE niet ondersteund op doelsysteem
 | ||
| % The \var{\{\$APPTYPE\}} directive is supported by win32 applications only.
 | ||
| scan_w_decription_not_support=02046_W_DESCRIPTION is slechts toegestaan onder OS2 en Win32
 | ||
| % The \var{\{\$DESCRIPTION\}} directive is only supported for OS2 and Win32 targets.
 | ||
| scan_n_version_not_support=02047_N_VERSION is niet ondersteund door het doel OS.
 | ||
| % The \var{\{\$VERSION\}} directive is only supported by win32 target.
 | ||
| scan_n_only_exe_version=02048_N_VERSION kan alleen voor executables of bibliotheken
 | ||
| % The \var{\{\$VERSION\}} directive is only used for executable or DLL sources.
 | ||
| scan_w_wrong_version_ignored=02049_W_verkeerd formaat voor VERSION directive $1
 | ||
| % The \var{\{\$VERSION\}} directive format is major_version.minor_version
 | ||
| % where major_version and minor_version are words.
 | ||
| scan_w_unsupported_asmmode_specifier=02050_W_Niet ondersteunde assembler soort gegeven $1
 | ||
| % When you specify an assembler mode with the \var{\{\$ASMMODE xxx\}}
 | ||
| % the compiler didn't recognize the mode you specified.
 | ||
| scan_w_no_asm_reader_switch_inside_asm=02051_W_ASM lezer-optie is niet mogelijk in een asm instructie, $1 ingesteld voor volgende blok
 | ||
| % It is not possible to switch from one assembler reader to another
 | ||
| % inside an assmebler block. The new reader will be used for next
 | ||
| % assembler statement only.
 | ||
| scan_e_wrong_switch_toggle=02052_E_Verkeerde optiewaarde, gebruik ON/OFF of +/-
 | ||
| % You need to use ON or OFF or a + or - to toggle the switch
 | ||
| scan_e_resourcefiles_not_supported=02053_E_Resource bestanden worden niet ondersteund op doel OS
 | ||
| % The target you are compiling for doesn't support Resource files. The
 | ||
| % only target which can use resource files is Win32
 | ||
| %
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Parser
 | ||
| #
 | ||
| % \section{Parser messages}
 | ||
| % This section lists all parser messages. The parser takes care of the
 | ||
| % semantics of you language, i.e. it determines if your pascal constructs
 | ||
| % are correct.
 | ||
| % \begin{description}
 | ||
| scan_w_include_env_not_found=02054_W_Include omgevingsvariabele $1 niet gevonden in omgeving
 | ||
| % The included environment variable can't be found in the environment, it'll
 | ||
| % be replaced by an empty string instead.
 | ||
| scan_e_invalid_maxfpureg_value=02055_E_Ongeldige waarde voor FPU register limiet
 | ||
| % Valid values for this directive are 0..8 and NORMAL/DEFAULT
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Parser
 | ||
| #
 | ||
| % \section{Parser messages}
 | ||
| % This section lists all parser messages. The parser takes care of the
 | ||
| % semantics of you language, i.e. it determines if your pascal constructs
 | ||
| % are correct.
 | ||
| % \begin{description}
 | ||
| scan_w_only_one_resourcefile_supported=02056_W_Only one resource file is supported for this target
 | ||
| % The target you are compiling for supports only one resource file. This is the
 | ||
| % case of OS/2 (EMX) currently. The first resource file found is used, the
 | ||
| % others are discarded.
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Parser
 | ||
| #
 | ||
| % \section{Parser messages}
 | ||
| % This section lists all parser messages. The parser takes care of the
 | ||
| % semantics of you language, i.e. it determines if your pascal constructs
 | ||
| % are correct.
 | ||
| % \begin{description}
 | ||
| parser_e_syntax_error=03000_E_Parser - Taalfout
 | ||
| % An error against the Turbo Pascal language was encountered. This happens
 | ||
| % typically when an illegal character is found in the sources file.
 | ||
| parser_w_proc_far_ignored=03001_W_Procedure type FAR genegeerd
 | ||
| % This is a warning. \var{FAR} is a construct for 8 or 16 bit programs. Since
 | ||
| % the compile generates 32 bit programs, it ignores this directive.
 | ||
| parser_w_proc_near_ignored=03002_W_Procedure type NEAR genegeerd
 | ||
| % This is a warning. \var{NEAR} is a construct for 8 or 16 bit programs. Since
 | ||
| % the compile generates 32 bit programs, it ignores this directive.
 | ||
| parser_w_proc_interrupt_ignored=03003_W_Procedure type INTERRUPT genegeerd
 | ||
| % This is a warning. \var{INTERRUPT} is a i386 specific construct
 | ||
| % and is igonred for other processors.
 | ||
| parser_e_dont_nest_interrupt=03004_E_INTERRUPT procedures kunnen niet genest worden
 | ||
| % An \VAR{INTERRUPT} procedure must be global.
 | ||
| parser_w_proc_directive_ignored=03005_W_Procedure type $1 ignored
 | ||
| % This is a warning. \var{REGISTER},\var{REINTRODUCE} is ignored by FPC programs for now.
 | ||
| % This is introduced first for Delphi compatibility.
 | ||
| parser_e_no_overload_for_all_procs=03006_E_Not all declarations of $1 are declared with OVERLOAD
 | ||
| % When you want to use overloading using the \var{OVERLOAD} directive, then
 | ||
| % all declarations need to have \var{OVERLOAD} specified.
 | ||
| parser_e_no_dll_file_specified=03007_E_Geen DLL bestand opgegeven
 | ||
| % No longer in use.
 | ||
| parser_e_export_name_double=03008_E_Dubbel geexporteerde functienaam $1
 | ||
| % Exported function names inside a specific DLL must all be different
 | ||
| parser_e_export_ordinal_double=03009_E_Dubbel geexporteerde functie index $1
 | ||
| % Exported function names inside a specific DLL must all be different
 | ||
| parser_e_export_invalid_index=03010_E_Ongeldige index for geexporteerde functie
 | ||
| % DLL function index must be in the range \var{1..\$FFFF}
 | ||
| parser_w_parser_reloc_no_debug=03011_W_Relocatable bibliotheek of applicatie $1 debug informatie niet ondersteund.
 | ||
| parser_w_parser_win32_debug_needs_WN=03012_W_Om win32 code te debuggen moet relocatie afgezet worden door de -WN optie
 | ||
| % Stabs info is wrong for relocatable DLL or EXES use -WN
 | ||
| % if you want to debug win32 executables.
 | ||
| parser_e_constructorname_must_be_init=03013_E_Constructornaam moet INIT zijn
 | ||
| % You are declaring a constructor with a name which isn't \var{init}, and the
 | ||
| % \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
 | ||
| parser_e_destructorname_must_be_done=03014_E_Destructornaam moet DONE zijn
 | ||
| % You are declaring a constructor with a name which isn't \var{done}, and the
 | ||
| % \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
 | ||
| parser_e_illegal_open_parameter=03015_E_Foutieve open parameter
 | ||
| % You are trying to use the wrong type for an open parameter.
 | ||
| parser_e_proc_inline_not_supported=03016_E_Procedure type INLINE wordt niet ondersteund
 | ||
| % You tried to compile a program with C++ style inlining, and forgot to
 | ||
| % specify the \var{-Si} option (\seeo{Si}). The compiler doesn't support C++
 | ||
| % styled inlining by default.
 | ||
| parser_w_priv_meth_not_virtual=03017_W_Private methoden zijn niet VIRTUAL
 | ||
| % You declared a method in the private part of a object (class) as
 | ||
| % \var{virtual}. This is not allowed. Private methods cannot be overridden
 | ||
| % anyway.
 | ||
| parser_w_constructor_should_be_public=03018_E_Constructor mag niet private or protected zijn
 | ||
| % Constructors must be in the 'public' part of an object (class) declaration.
 | ||
| parser_w_destructor_should_be_public=03019_E_Destructor mag niet private or protected zijn
 | ||
| % Destructors must be in the 'public' part of an object (class) declaration.
 | ||
| parser_n_only_one_destructor=03020_N_Klasse heeft slechts 1 destructor
 | ||
| % You can declare only one destructor for a class.
 | ||
| parser_e_no_local_objects=03021_E_Lokale klassedefinities zijn niet toegestaan
 | ||
| % Classes must be defined globally. They cannot be defined inside a
 | ||
| % procedure or function
 | ||
| parser_f_no_anonym_objects=03022_F_Anonieme klassedefinities zijn niet toegestaan
 | ||
| % An invalid object (class) declaration was encountered, i.e. an
 | ||
| % object or class without methods that isn't derived from another object or
 | ||
| % class. For example:
 | ||
| % \begin{verbatim}
 | ||
| % Type o = object
 | ||
| %          a : longint;
 | ||
| %          end;
 | ||
| % \end{verbatim}
 | ||
| % will trigger this error.
 | ||
| parser_object_has_no_vmt=03023_E_Het object $1 heeft geen VMT
 | ||
| parser_e_illegal_parameter_list=03024_E_Foutieve parameterlijst
 | ||
| % You are calling a function with parameters that are of a different type than
 | ||
| % the declared parameters of the function.
 | ||
| parser_e_wrong_parameter_type=03025_E_Foutief parametertype meegegeven voor arg #$1
 | ||
| % There is an error in the parameter list of the function or procedure.
 | ||
| % The compiler cannot determine the error more accurate than this.
 | ||
| parser_e_wrong_parameter_size=03026_E_Onjuist aantal parameters meegegeven
 | ||
| % There is an error in the parameter list of the function or procedure,
 | ||
| % the number of parameters is not correct.
 | ||
| parser_e_overloaded_no_procedure=03027_E_Overroepen symbool is geen procedure of functie
 | ||
| % The compiler encountered a symbol with the same name as an overloaded
 | ||
| % function, but it isn't a function it can overload.
 | ||
| parser_e_overloaded_have_same_parameters=03028_E_Overroepen procedures hebben identieke parameterlijst
 | ||
| % You're declaring overloaded functions, but with the same parameter list.
 | ||
| % Overloaded function must have at least 1 different parameter in their
 | ||
| % declaration.
 | ||
| parser_e_header_dont_match_forward=03029_E_Declaratie komt niet overeen met eerdere declaratie: $1
 | ||
| % You declared a function with same parameters but
 | ||
| % different result type or function specifiers.
 | ||
| parser_e_header_different_var_names=03030_E_Procedurehoofding $1 komt niet overeen met eerdere declaratie: variabelenaam veranderd $2 => $3
 | ||
| % You declared the function in the \var{interface} part, or with the
 | ||
| % \var{forward} directive, but define it with a different parameter list.
 | ||
| parser_n_duplicate_enum=03031_N_Waarden in opsommingstypes moeten steeds stijgen
 | ||
| % \fpc allows enumeration constructions as in C. Given the following
 | ||
| % declaration two declarations:
 | ||
| % \begin{verbatim}
 | ||
| % type a = (A_A,A_B,A_E:=6,A_UAS:=200);
 | ||
| % type a = (A_A,A_B,A_E:=6,A_UAS:=4);
 | ||
| % \end{verbatim}
 | ||
| % The second declaration would produce an error. \var{A\_UAS} needs to have a
 | ||
| % value higher than \var{A\_E}, i.e. at least 7.
 | ||
| parser_n_interface_name_diff_implementation_name=03032_N_Interface- en implementatienamen zijn verschillend
 | ||
| % This note warns you if the implementation and interface names of a
 | ||
| % functions are different, but they have the same mangled name. This
 | ||
| % is important when using overloaded functions (but should produce no error).
 | ||
| parser_e_no_with_for_variable_in_other_segments=03033_E_With kan niet gebruikt worden voor variabelen in verschillende segmenten
 | ||
| % With stores a variable locally on the stack,
 | ||
| % but this is not possible if the variable belongs to another segment.
 | ||
| parser_e_too_much_lexlevel=03034_E_Procedure meer dan 31 keer genest
 | ||
| % You can nest function definitions only 31 times.
 | ||
| parser_e_range_check_error=03035_E_Bereikfout bij evalueren constanten
 | ||
| % The constants are out of their allowed range.
 | ||
| parser_w_range_check_error=03036_W_Bereikscontrolefout bij evalueren constantes.
 | ||
| % The constants are out of their allowed range.
 | ||
| parser_e_double_caselabel=03037_E_Dubbel case-element
 | ||
| % You are specifying the same label 2 times in a \var{case} statement.
 | ||
| parser_e_case_lower_less_than_upper_bound=03038_E_Bovengrens van casebereik is lager dan ondergrens
 | ||
| % The upper bound of a \var{case} label is less than the lower bound and this
 | ||
| % is useless
 | ||
| parser_e_type_const_not_possible=03039_E_Getypeerde constanten van klassen zijn niet toegestaan
 | ||
| % You cannot declare a constant of type class or object.
 | ||
| parser_e_no_overloaded_procvars=03040_E_Procedurele variabelen van overroepen procedures zijn niet toegestaan
 | ||
| % You are trying to assign an overloaded function to a procedural variable.
 | ||
| % This isn't allowed.
 | ||
| parser_e_invalid_string_size=03041_E_Stringlengte moet tussen 1 en 255 liggen
 | ||
| % The length of a string in Pascal is limited to 255 characters. You are
 | ||
| % trying to declare a string with length lower than 1 or greater than 255
 | ||
| % (This is not true for \var{Longstrings} and \var{AnsiStrings}.
 | ||
| parser_w_use_extended_syntax_for_objects=03042_W_Gebruik de uitgebreide syntax van DISPOSE en NEW om nieuwe instanties van klassen te genereren
 | ||
| % If you have a pointer \var{a} to a class type, then the statement
 | ||
| % \var{new(a)} will not initialize the class (i.e. the constructor isn't
 | ||
| % called), although space will be allocated. you should issue the
 | ||
| % \var{new(a,init)} statement. This will allocate space, and call the
 | ||
| % constructor of the class.
 | ||
| parser_w_no_new_dispose_on_void_pointers=03043_W_Het gebruik van NEW of DISPOSE voor pointers zonder type is zinloos
 | ||
| parser_e_no_new_dispose_on_void_pointers=03044_E_Het gebruik van NEW of DISPOSE is niet mogelijk voor pointers zonder type
 | ||
| % You cannot use \var{new(p)} or \var{dispose(p)} if \var{p} is an untyped pointer
 | ||
| % because no size is associated to an untyped pointer.
 | ||
| % Accepted for compatibility in \var{tp} and \var{delphi} modes.
 | ||
| parser_e_class_id_expected=03045_E_Klasse verwacht
 | ||
| % This happens when the compiler scans a procedure declaration that contains
 | ||
| % a dot,
 | ||
| % i.e., a object or class method, but the type in front of the dot is not
 | ||
| % a known type.
 | ||
| parser_e_no_type_not_allowed_here=03046_E_Typesymbool is hier niet toegestaan
 | ||
| % You cannot use a type inside an expression.
 | ||
| parser_e_methode_id_expected=03047_E_Methode verwacht
 | ||
| % This identifier is not a method.
 | ||
| % This happens when the compiler scans a procedure declaration that contains
 | ||
| % a dot, i.e., a object or class method, but the procedure name is not a
 | ||
| % procedure of this type.
 | ||
| parser_e_header_dont_match_any_member=03048_E_Proceduredeclaratie komt niet overeen met een methode van deze klasse $1
 | ||
| % This identifier is not a method.
 | ||
| % This happens when the compiler scans a procedure declaration that contains
 | ||
| % a dot, i.e., a object or class method, but the procedure name is not a
 | ||
| % procedure of this type.
 | ||
| parser_p_procedure_start=03049_P_Procedure/functie $1 ($2) op regel $3
 | ||
| % When using the \var{-vp} switch, the compiler tells you when it starts
 | ||
| % processing a procedure or function implementation.
 | ||
| parser_e_error_in_real=03050_E_Foutieve vlottende-komma constante
 | ||
| % The compiler expects a floating point expression, and gets something else.
 | ||
| parser_e_fail_only_in_constructor=03051_E_FAIL mag alleen in constructors gebruikt worden
 | ||
| % You are using the \var{FAIL} instruction outside a constructor method.
 | ||
| parser_e_no_paras_for_destructor=03052_E_Destructors hebben geen parameters
 | ||
| % You are declaring a destructor with a parameter list. Destructor methods
 | ||
| % cannot have parameters.
 | ||
| parser_e_only_class_methods_via_class_ref=03053_E_Alleen klassemethoden kunnen gerefereerd worden via een klasse
 | ||
| % This error occurs in a situation like the following:
 | ||
| % \begin{verbatim}
 | ||
| % Type :
 | ||
| %    Tclass = Class of Tobject;
 | ||
| %
 | ||
| % Var C : TClass;
 | ||
| %
 | ||
| % begin
 | ||
| % ...
 | ||
| % C.free
 | ||
| % \end{verbatim}
 | ||
| % \var{Free} is not a class method and hence cannot be called with a class
 | ||
| % reference.
 | ||
| parser_e_only_class_methods=03054_E_Alleen klassemethoden zijn toegankelijk in klassen
 | ||
| % This is related to the previous error. You cannot call a method of an object
 | ||
| % from a inside a class method. The following code would produce this error:
 | ||
| % \begin{verbatim}
 | ||
| % class procedure tobject.x;
 | ||
| %
 | ||
| % begin
 | ||
| %   free
 | ||
| % \end{verbatim}
 | ||
| % Because free is a normal method of a class it cannot be called from a class
 | ||
| % method.
 | ||
| parser_e_case_mismatch=03055_E_Type van constante komt niet overeen met dat van de case uitrukking
 | ||
| % One of the labels is not of the same type as the case variable.
 | ||
| parser_e_illegal_symbol_exported=03056_E_Het symbool kan niet uitgevoerd worden uit een bibliotheek
 | ||
| % You can only export procedures and functions when you write a library. You
 | ||
| % cannot export variables or constants.
 | ||
| parser_w_should_use_override=03057_E_Een virtuele methode moet met OVERRIDE overroepen worden: $1
 | ||
| % A method that is declared \var{virtual} in a parent class, should be
 | ||
| % overridden in the descendent class with the \var{override} directive. If you
 | ||
| % don't specify the \var{override} directive, you will hide the parent method;
 | ||
| % you will not override it.
 | ||
| parser_e_nothing_to_be_overridden=03058_E_Er is geen geerfde methode die overroepen kan worden: $1
 | ||
| % You try to \var{override} a virtual method of a parent class that doesn't
 | ||
| % exist.
 | ||
| parser_e_no_procedure_to_access_property=03059_E_Er is geen lid om de eigenschap te bereiken
 | ||
| % You specified no \var{read} directive for a property.
 | ||
| parser_w_stored_not_implemented=03060_W_Stored prorperty directive is not yet implemented
 | ||
| % The \var{stored} directive is not yet implemented
 | ||
| parser_e_ill_property_access_sym=03061_E_Ongeldig symbool voor eigenschaptoegang
 | ||
| % There is an error in the \var{read} or \var{write} directives for an array
 | ||
| % property. When you declare an array property, you can only access it with
 | ||
| % procedures and functions. The following code woud cause such an error.
 | ||
| % \begin{verbatim}
 | ||
| % tmyobject = class
 | ||
| %   i : integer;
 | ||
| %   property x [i : integer]: integer read I write i;
 | ||
| % \end{verbatim}
 | ||
| %
 | ||
| parser_e_cant_access_protected_member=03062_E_Kan niet in beschermd veld van een object schrijven
 | ||
| % Fields that are declared in a \var{protected} section of an object or class
 | ||
| % declaration cannot be accessed outside the module wher the object is
 | ||
| % defined, or outside descendent object methods.
 | ||
| parser_e_cant_access_private_member=03063_E_Kan niet in prive-veld van een object schrijven
 | ||
| % Fields that are declared in a \var{private} section of an object or class
 | ||
| % declaration cannot be accessed outside the module where the class is
 | ||
| % defined.
 | ||
| parser_w_overloaded_are_not_both_virtual=03064_W_Alle overroepen methoden moeten virtueel zijn als 1 virtueel is: $1
 | ||
| % If you declare overloaded methods in a class, then they should either all be
 | ||
| % virtual, or none. You shouldn't mix them.
 | ||
| parser_w_overloaded_are_not_both_non_virtual=03065_W_Overroepen methode van een niet virtuele methode moet niet-virtueel zijn: $1
 | ||
| % If you declare overloaded methods in a class, then they should either all be
 | ||
| % virtual, or none. You shouldn't mix them.
 | ||
| parser_e_overloaded_methodes_not_same_ret=03066_E_Virtuele overroepen methodes moeten dezelfde resultaat-type hebben: $1
 | ||
| % If you declare virtual overloaded methods in a class definition, they must
 | ||
| % have the same return type.
 | ||
| parser_e_dont_nest_export=03067_E_Als EXPORT gedeclareerde procedures kunnen niet genest worden
 | ||
| % You cannot declare a function or procedure within a function or procedure
 | ||
| % that was declared as an export procedure.
 | ||
| parser_e_methods_dont_be_export=03068_E_Methoden kunnen niet geexporteerd worden.
 | ||
| % You cannot declare a procedure that is a method for an object as
 | ||
| % \var{export}ed. That is, your methods cannot be called from a C program.
 | ||
| parser_e_call_by_ref_without_typeconv=03069_E_Typen van referentieparameters moeten exact overeenkomen.
 | ||
| % When calling a function declared with \var{var} parameters, the variables in
 | ||
| % the function call must be of exactly the same type. There is no automatic
 | ||
| % type conversion.
 | ||
| parser_e_no_super_class=03070_E_Deze klasse is geen ouderklasse van de huidige klasse
 | ||
| % When calling inherited methods, you are trying to call a method of a strange
 | ||
| % class. You can only call an inherited method of a parent class.
 | ||
| parser_e_self_not_in_method=03071_E_SELF is alleen toegelaten in methoden.
 | ||
| % You are trying to use the \var{self} parameter outside an object's method.
 | ||
| % Only methods get passed the \var{self} parameters.
 | ||
| parser_e_generic_methods_only_in_methods=03072_E_Methoden kunnen alleen in andere methoden worden aangeroepen met type symbool
 | ||
| % A construction like \var{sometype.somemethod} is only allowed in a method.
 | ||
| parser_e_illegal_colon_qualifier=03073_E_Ongeldig gebruik van ':'
 | ||
| % You are using the format \var{:} (colon) 2 times on an expression that
 | ||
| % is not a real expression.
 | ||
| parser_e_illegal_set_expr=03074_E_Bereikfout in setconstructor of dubbel setelement
 | ||
| % The declaration of a set contains an error. Either one of the elements is
 | ||
| % outside the range of the set type, either two of the elements are in fact
 | ||
| % the same.
 | ||
| parser_e_pointer_to_class_expected=03075_E_Pointer naar klasse verwacht
 | ||
| % You specified an illegal type in a \var{New} statement.
 | ||
| % The extended synax of \var{New} needs an  object as a parameter.
 | ||
| parser_e_expr_have_to_be_constructor_call=03076_E_Uitdrukking moet een constructoraanroep zijn.
 | ||
| % When using the extended syntax of \var{new}, you must specify the constructor
 | ||
| % method of the object you are trying to create. The procedure you specified
 | ||
| % is not a constructor.
 | ||
| parser_e_expr_have_to_be_destructor_call=03077_E_Uitdrukking moet een destructoraanroep zijn
 | ||
| % When using the extended syntax of \var{dispose}, you must specify the
 | ||
| % destructor method of the object you are trying to dispose of.
 | ||
| % The procedure you specified is not a destructor.
 | ||
| parser_e_invalid_record_const=03078_E_Ongeldige volgorde van record leden
 | ||
| % When declaring a constant record, you specified the fields in the wrong
 | ||
| % order.
 | ||
| parser_e_false_with_expr=03079_E_Type van uitdrukking moet class of record type zijn
 | ||
| % A \var{with} statement needs an argument that is of the type \var{record}
 | ||
| % or \var{class}. You are using \var{with} on an expression that is not of
 | ||
| % this type.
 | ||
| parser_e_void_function=03080_E_Procedures kunnen geen resultaat teruggeven
 | ||
| % In \fpc, you can specify a return value for a function when using
 | ||
| % the \var{exit} statement. This error occurs when you try to do this with a
 | ||
| % procedure. Procedures  cannot return a value.
 | ||
| parser_e_constructors_always_objects=03081_E_Constructors en destructors moeten methoden zijn
 | ||
| % You're declaring a procedure as destructor or constructor, when the
 | ||
| % procedure isn't a class method.
 | ||
| parser_e_operator_not_overloaded=03082_E_Operator is niet hergedefineerd
 | ||
| % You're trying to use an overloaded operator when it isn't overloaded for
 | ||
| % this type.
 | ||
| parser_e_no_such_assignment=03083_E_Het is niet toegestaan de toewijzingsoperator te overroepen voor gelijke typen
 | ||
| % You can not overload assignment for types
 | ||
| % that the compiler considers as equal.
 | ||
| parser_e_overload_impossible=03084_E_Het overroepen van deze operator is onmogelijk
 | ||
| % The combination of operator, arguments and return type are
 | ||
| % incompatible.
 | ||
| parser_e_no_reraise_possible=03085_E_Re-raise is hier niet mogelijk
 | ||
| % You are trying to raise an exception where it isn't allowed. You can only
 | ||
| % raise exceptions in an \var{except} block.
 | ||
| parser_e_no_new_or_dispose_for_classes=03086_E_De uitgebreide syntax van NEW of DISPOSE is niet toegestaan voor klassen
 | ||
| % You cannot generate an instance of a class with the extended syntax of
 | ||
| % \var{new}. The constructor must be used for that. For the same reason, you
 | ||
| % cannot call \var{Dispose} to de-allocate an instance of a class, the
 | ||
| % destructor must be used for that.
 | ||
| parser_e_asm_incomp_with_function_return=03087_E_Assembler stemt niet overeen met type van functieresultaat
 | ||
| % You're trying to implement a \var{assembler} function, but the return type
 | ||
| % of the function doesn't allow that.
 | ||
| parser_e_procedure_overloading_is_off=03088_E_Procedure overroepen is afgezet
 | ||
| % When using the \var{-So} switch, procedure overloading is switched off.
 | ||
| % Turbo Pascal does not support function overloading.
 | ||
| parser_e_overload_operator_failed=03089_E_Deze operator kan niet overroepen worden.
 | ||
| % You are trying to overload an operator which cannot be overloaded.
 | ||
| % The following operators can be overloaded :
 | ||
| % \begin{verbatim}
 | ||
| %    +, -, *, /, =, >, <, <=, >=, is, as, in, **, :=
 | ||
| % \end{verbatim}
 | ||
| parser_e_comparative_operator_return_boolean=03090_E_Vergelijkingsoperator moet een boolean type als resultaat hebben.
 | ||
| % When overloading the \var{=} operator, the function must return a boolean
 | ||
| % value.
 | ||
| parser_e_only_virtual_methods_abstract=03091_E_Enkel virtuele methoden kunnen abstract zijn
 | ||
| % You are declaring a method as abstract, when it isn't declared to be
 | ||
| % virtual.
 | ||
| parser_f_unsupported_feature=03092_F_Gebruik van niet ondersteunde functionaliteit!
 | ||
| % You're trying to force the compiler into doing something it cannot do yet.
 | ||
| parser_e_mix_of_classes_and_objects=03093_E_CLASSES and OBJECTS kunnen niet gemengd worden.
 | ||
| % You cannot derive \var{objects} and \var{classes} intertwined . That is,
 | ||
| % a class cannot have an object as parent and vice versa.
 | ||
| parser_w_unknown_proc_directive_ignored=03094_W_Onbekende proceduredirective is genegeerd: $1
 | ||
| % The procedure direcive you secified is unknown. Recognised procedure
 | ||
| % directives are \var{cdecl}, \var{stdcall}, \var{popstack}, \var{pascal}
 | ||
| % \var{register}, \var{export}.
 | ||
| parser_e_absolute_only_one_var=03095_E_Absolute kan maar aan een variabele verbonden worden.
 | ||
| % You cannot specify more than one variable before the \var{absolute} directive.
 | ||
| % Thus, the following construct will provide this error:
 | ||
| % \begin{verbatim}
 | ||
| % Var Z : Longint;
 | ||
| %     X,Y : Longint absolute Z;
 | ||
| % \end{verbatim}
 | ||
| % \item [ absolute can only be associated a var or const ]
 | ||
| % The address of a \var{absolute} directive can only point to a variable or
 | ||
| % constant. Therefore, the following code will produce this error:
 | ||
| % \begin{verbatim}
 | ||
| %   Procedure X;
 | ||
| %
 | ||
| %  var p : longint absolute x;
 | ||
| % \end{verbatim}
 | ||
| %
 | ||
| parser_e_absolute_only_to_var_or_const=03096_E_Absolute kan slechts aan variabelen of constanten verbonden worden.
 | ||
| % The address of a \var{absolute} directive can only point to a variable or
 | ||
| % constant. Therefore, the following code will produce this error:
 | ||
| % \begin{verbatim}
 | ||
| %   Procedure X;
 | ||
| %
 | ||
| %  var p : longint absolute x;
 | ||
| % \end{verbatim}
 | ||
| %
 | ||
| parser_e_initialized_only_one_var=03097_E_Slechts 1 variabele kan geinitialiseerd worden.
 | ||
| % You cannot specify more than one variable with a initial value
 | ||
| % in Delphi syntax.
 | ||
| parser_e_abstract_no_definition=03098_E_Abtracte methoden kunnen niet gedefineerd worden
 | ||
| % Abstract methods can only be declared, you cannot implement them. They
 | ||
| % should be overridden by a descendant class.
 | ||
| parser_e_overloaded_must_be_all_global=03099_E_Deze overroepen procedure kan niet lokaal zijn (moet geexporteerd worden)
 | ||
| % You are defining a overloaded function in the implementation part of a unit,
 | ||
| % but there is no corresponding declaration in the interface part of the unit.
 | ||
| parser_w_virtual_without_constructor=03100_W_Gebruik van virtuele methoden zonder constructor
 | ||
| % If you declare objects or classes that contain virtual methods, you need
 | ||
| % to have a constructor and destructor to initialize them. The compiler
 | ||
| % encountered an object or class with virtual methods that doesn't have
 | ||
| % a constructor/destructor pair.
 | ||
| parser_m_macro_defined=03101_M_Macro gedefinieerd: $1
 | ||
| % When \var{-vm} is used, the compiler tells you when it defines macros.
 | ||
| parser_m_macro_undefined=03102_M_Macro opgeheven: $1
 | ||
| % When \var{-vm} is used, the compiler tells you when it undefines macros.
 | ||
| parser_m_macro_set_to=03103_M_Macro $1 wordt $2
 | ||
| % When \var{-vm} is used, the compiler tells you what values macros get.
 | ||
| parser_i_compiling=03104_I_Compilatie van $1
 | ||
| % When you turn on information messages (\var{-vi}), the compiler tells you
 | ||
| % what units it is recompiling.
 | ||
| parser_u_parsing_interface=03105_U_Parsen van de interface van unit $1
 | ||
| % This tells you that the reading of the interface
 | ||
| % of the current unit starts
 | ||
| parser_u_parsing_implementation=03106_U_Parsen van de implementatie van unit $1
 | ||
| % This tells you that the code reading of the implementation
 | ||
| % of the current unit, library or program starts
 | ||
| parser_d_compiling_second_time=03107_D_Compilatie van $1 voor de tweede keer.
 | ||
| % When you request debug messages (\var{-vd}) the compiler tells you what
 | ||
| % units it recompiles for the second time.
 | ||
| parser_e_no_paras_allowed=03108_E_Array eigenschappen zijn hier niet toegestaan.
 | ||
| % You cannot use  array properties at that point.a
 | ||
| parser_e_no_property_found_to_override=03109_E_Geen eigenschap gevonden om te herdefinieren
 | ||
| % You want to overrride a property of a parent class, when there is, in fact,
 | ||
| % no such property in the parent class.
 | ||
| parser_e_only_one_default_property=03110_E_Slechts 1 standaardeigenschap is toegestaan, geerfde standaardeigenschap in kind gevonden.
 | ||
| % You specified a property as \var{Default}, but a parent class already has a
 | ||
| % default property, and a class can have only one default property.
 | ||
| parser_e_property_need_paras=03111_E_Standaardeigenschappen moeten van type array zijn.
 | ||
| % Only array properties of classes can be made \var{default} properties.
 | ||
| parser_e_constructor_cannot_be_not_virtual=03112_E_Virtuele constructors worden alleen ondersteunt in het klassemodel
 | ||
| % You cannot have virtual constructors in objects. You can only have them
 | ||
| % in classes.
 | ||
| parser_e_no_default_property_available=03113_E_Geen standaardeigenschap gevonden
 | ||
| % You try to access a default property of a class, but this class (or one of
 | ||
| % it's ancestors) doesn't have a default property.
 | ||
| parser_e_cant_have_published=03114_E_De klasse kan geen gepubliceerde sectie hebben, gebruik {$M+}
 | ||
| % If you want a \var{published} section in a class definition, you must
 | ||
| % use the \var{\{\$M+\}} switch, whch turns on generation of type
 | ||
| % information.
 | ||
| parser_e_forward_declaration_must_be_resolved=03115_E_Declaratie van klasse $1 moet worden opgelost om de klasse als ouder te gebruiken
 | ||
| % To be able to use an object as an ancestor object, it must be defined
 | ||
| % first. This error occurs in the following situation:
 | ||
| % \begin{verbatim}
 | ||
| %  Type ParentClas = Class;
 | ||
| %       ChildClass = Class(ParentClass)
 | ||
| %         ...
 | ||
| %       end;
 | ||
| % \end{verbatim}
 | ||
| % Where \var{ParentClass} is declared but not defined.
 | ||
| parser_e_no_local_operator=03116_E_Lokale operatoren worden niet ondersteund
 | ||
| % You cannot overload locally, i.e. inside procedures or function
 | ||
| % definitions.
 | ||
| parser_e_proc_dir_not_allowed_in_interface=03117_E_Procedure directive $1 niet toegestaan in interfacesectie
 | ||
| % This procedure directive is not allowed in the \var{interface} section of
 | ||
| % a unit. You can only use it in the \var{implementation} section.
 | ||
| parser_e_proc_dir_not_allowed_in_implementation=03118_E_Procedure directive $1 niet toegestaan in implementatiesectie
 | ||
| % This procedure directive is not defined in the \var{implementation} section of
 | ||
| % a unit. You can only use it in the \var{interface} section.
 | ||
| parser_e_proc_dir_not_allowed_in_procvar=03119_E_Procedure directive $1 niet toegestaan in procvar declaratie
 | ||
| % This procedure directive cannot be part of a procedural of function
 | ||
| % type declaration.
 | ||
| parser_e_function_already_declared_public_forward=03120_E_Functie is al publiek/forward gedeclareerd $1
 | ||
| % You will get this error if a function is defined as \var{forward} twice.
 | ||
| % Or it is once in the \var{interface} section, and once as a \var{forward}
 | ||
| % declaration in the \var{implmentation} section.
 | ||
| parser_e_not_external_and_export=03121_E_Kan niet zowel EXPORT als EXTERNAL gebruiken
 | ||
| % These two procedure directives are mutually exclusive
 | ||
| parser_e_name_keyword_expected=03122_E_NAME sleutelwoord verwacht
 | ||
| % The definition of an external variable needs a \var{name} clause.
 | ||
| parser_w_not_supported_for_inline=03123_W_$1 wordt niet ondersteund voor inline procedure/functie
 | ||
| % Inline procedures don't support this declaration.
 | ||
| parser_w_inlining_disabled=03124_W_Inlining uitgeschakeld
 | ||
| % Inlining of procedures is disabled.
 | ||
| parser_i_writing_browser_log=03125_I_Schrijven van browser logfile $1
 | ||
| % When information messages are on, the compiler warns you when it
 | ||
| % writes the browser log (generated with the \var{\{\$Y+ \}} switch).
 | ||
| parser_h_maybe_deref_caret_missing=03126_H_misschien is het een pointer, ^ ontbreekt dan
 | ||
| % The compiler thinks that a pointer may need a dereference.
 | ||
| parser_f_assembler_reader_not_supported=03127_F_Geselecteerde assemblerlezer wordt niet ondersteund
 | ||
| % The selected assembler reader (with \var{\{\$ASMMODE xxx\}} is not
 | ||
| % supported. The compiler can be compiled with or without support for a
 | ||
| % particular assembler reader.
 | ||
| parser_e_proc_dir_conflict=03128_E_Procedure directive $1 geeft conflicten met andere directives
 | ||
| % You specified a procedure directive that conflicts with other directives.
 | ||
| % for instance \var{cdecl} and \var{pascal} are mutually exclusive.
 | ||
| parser_e_call_convention_dont_match_forward=03129_E_Aanroep conventie klopt niet met voorwaartse
 | ||
| % This error happens when you declare a function or procedure with
 | ||
| % e.g. \var{cdecl;} but omit this directive in the implementation, or vice
 | ||
| % versa. The calling convention is part of the function declaration, and
 | ||
| % must be repeated in the function definition.
 | ||
| parser_e_register_calling_not_supported=03130_E_Registeraanroep (fastcall) wordt niet ondersteund
 | ||
| % The \var{register} calling convention, i.e., arguments are passed in
 | ||
| % registers instead of on the stack is not supported. Arguments are always
 | ||
| % passed on the stack.
 | ||
| parser_e_property_cant_have_a_default_value=03131_E_Eigenschap kan geen standaard waarde hebben
 | ||
| % Set properties or indexed properties cannot have a default value.
 | ||
| parser_e_property_default_value_must_const=03132_E_De standaard waarde van een eigenschap moet een constante zijn
 | ||
| % The value of a \var{default} declared property must be knwon at compile
 | ||
| % time. The value you specified is only known at run time. This happens
 | ||
| % .e.g. if you specify a variable name as a default value.
 | ||
| parser_e_cant_publish_that=03133_E_Symbool kan niet worden gepubliceerd, alleen mogelijk voor een klasse
 | ||
| % Only class type variables can be in a \var{published} section of a class
 | ||
| % if they are not declared as a property.
 | ||
| parser_e_cant_publish_that_property=03134_E_Dit soort eigenschappen kunnen niet worden gepubliceerd
 | ||
| % Properties in a \var{published} section cannot be array properties.
 | ||
| % they must be moved to public sections. Properties in a \var{published}
 | ||
| % section must be an ordinal type, a real type, strings or sets.
 | ||
| parser_w_empty_import_name=03135_W_Lege importnaam opgegeven.
 | ||
| % Both index and name for the import are 0 or empty
 | ||
| parser_e_empty_import_name=03136_W_Lege importnaam opgegeven
 | ||
| % Some targets need a name for the imported procedure or a cdecl specifier
 | ||
| parser_e_used_proc_name_changed=03137_E_Interne functienaam gewijzigd na declaratie.
 | ||
| % This is an internal error; please report any occurrences of this error
 | ||
| % to the \fpc team.
 | ||
| parser_e_division_by_zero=03138_E_Deling door nul
 | ||
| % There is a divsion by zero encounted
 | ||
| parser_e_invalid_float_operation=03139_E_Ongeldige vlottende-komma bewerking.
 | ||
| % An operation on two real type values produced an overflow or a division
 | ||
| % by zero.
 | ||
| parser_e_array_lower_less_than_upper_bound=03140_E_Bovengrens van bereik is lager dan ondergrens
 | ||
| % The upper bound of a \var{case} label is less than the lower bound and this
 | ||
| % is not possible
 | ||
| parser_w_string_too_long=03141_W_string "$1" is langer dan $2
 | ||
| % The size of the constant string is larger than the size you specified in
 | ||
| % string type definition
 | ||
| parser_e_string_larger_array=03142_E_Stringlengte moet tussen 1 en 255 liggen
 | ||
| % The size of the constant string is larger than the size you specified in
 | ||
| % the array[x..y] of char definition
 | ||
| parser_e_ill_msg_expr=03143_E_Ongeldige uitdrukking achter message optie
 | ||
| % \fpc supports only integer or string values as message constants
 | ||
| parser_e_ill_msg_param=03144_E_Message handlers aanvaarden slechts 1 variabele parameter
 | ||
| % A method declared with the \var{message}-directive as message handler
 | ||
| % can take only one parameter which must be declared as call by reference
 | ||
| % Parameters are declared as call by reference using the \var{var}-directive
 | ||
| parser_e_duplicate_message_label=03145_E_Dubbel message label: %1
 | ||
| % A label for a message is used twice in one object/class
 | ||
| parser_e_self_in_non_message_handler=03146_E_Self kan alleen een explicite parameter zijn bij string message handlers
 | ||
| % The self parameter can be passed only explicit if it is a method which
 | ||
| % is declared as message method handler
 | ||
| parser_e_threadvars_only_sg=03147_E_Threadvariabelen kunnen alleen globaal of statisch zijn
 | ||
| % Threadvars must be static or global, you can't declare a thread
 | ||
| % local to a procedure. Local variables are always local to a thread,
 | ||
| % because every thread has it's own stack and local variables
 | ||
| % are stored on the stack
 | ||
| parser_f_direct_assembler_not_allowed=03148_F_Directe assemblercode wordt niet ondersteund door de interne assembler.
 | ||
| % You can't use direct assembler when using a binary writer, choose an
 | ||
| % other outputformat or use an other assembler reader
 | ||
| parser_w_no_objpas_use_mode=03149_W_Laad de OBJPAS unit niet manueel, gebruik {$mode objfpc} of {$mode delphi}.
 | ||
| % You're trying to load the ObjPas unit manual from a uses clause. This is
 | ||
| % not a good idea to do, you can better use the \var{\{\$mode objfpc\}} or
 | ||
| % \var{\{\$mode delphi\}}
 | ||
| % directives which load the unit automaticly
 | ||
| parser_e_no_object_override=03150_E_OVERRIDE kan niet gebruikt worden in objecten
 | ||
| % Override isn't support for objects, use VIRTUAL instead to override
 | ||
| % a method of an anchestor object
 | ||
| parser_e_cant_use_inittable_here=03151_E_Datatypen die initializatie/finalizatie vereisen zijn niet toegestaan in variabele records.
 | ||
| % Some data type (e.g. \var{ansistring}) needs initialization/finalization
 | ||
| % code which is implicitly generated by the compiler. Such data types
 | ||
| % can't be used in the variant part of a record.
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Type Checking
 | ||
| #
 | ||
| % \section{Type checking errors}
 | ||
| % This section lists all errors that can occur when type checking is
 | ||
| % performed.
 | ||
| % \begin{description}
 | ||
| parser_e_resourcestring_only_sg=03152_E_Resourcestrings kunnen alleen statisch of globaal zijn.
 | ||
| % Resourcestring can not be declared local, only global or using the static
 | ||
| % directive.
 | ||
| parser_e_exit_with_argument_not__possible=03153_E_Exit met parameter is hier niet toegestaan
 | ||
| % an exit statement with an argument for the return value can't be used here, this
 | ||
| % can happen e.g. in \var{try..except} or \var{try..finally} blocks
 | ||
| parser_e_stored_property_must_be_boolean=03154_E_De stored directive verwacht een boolean argument.
 | ||
| % If you specify a storage symbol in a property declaration, it must be of
 | ||
| % the type boolean
 | ||
| parser_e_ill_property_storage_sym=03155_E_Dit symbool is niet toegestaan achter het stored sleutelwoord.
 | ||
| % You can't use this type of symbol as storage specifier in property
 | ||
| % declaration. You can use only methods with the result type boolean,
 | ||
| % boolean class fields or boolean constants
 | ||
| parser_e_only_publishable_classes_can__be_published=03156_E_Alleen klassen gecompileerd in $M+ modus kunnen een published sectie hebben.
 | ||
| % In the published section of a class can be only class as fields used which
 | ||
| % are compiled in $M+ or which are derived from such a class. Normally
 | ||
| % such a class should be derived from TPersitent
 | ||
| parser_e_proc_directive_expected=03157_E_Proceduredirective verwacht.
 | ||
| % When declaring a procedure in a const block you used a ; after the
 | ||
| % procedure declaration after which a procedure directive must follow.
 | ||
| % Correct declarations are:
 | ||
| % \begin{verbatim}
 | ||
| % const
 | ||
| %   p : procedure;stdcall=nil;
 | ||
| %   p : procedure stdcall=nil;
 | ||
| % \end{verbatim}
 | ||
| parser_e_invalid_property_index_value=03158_E_De waarde voor een eigenschapindex moet een ordinale waarde zijn.
 | ||
| % The value you use to index a property must be of an ordinal type, for
 | ||
| % example an integer or enumerated type.
 | ||
| parser_e_procname_to_short_for_export=03159_E_Procedurenaam te kort om te exporteren.
 | ||
| % The length of the procedure/function name must be at least 2 characters
 | ||
| % long. This is because of a bug in dlltool which doesn't parse the .def
 | ||
| % file correct with a name of length 1.
 | ||
| parser_e_dlltool_unit_var_problem=03160_E_Kan geen DEFFILE item genereren voor globale variabelen.
 | ||
| parser_e_dlltool_unit_var_problem2=03161_E_Compileer zonder -WD optie
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Type Checking
 | ||
| #
 | ||
| % \section{Type checking errors}
 | ||
| % This section lists all errors that can occur when type checking is
 | ||
| % performed.
 | ||
| % \begin{description}
 | ||
| type_e_mismatch=04000_E_Typen stemmen niet overeen
 | ||
| % This can happen in many cases:
 | ||
| % \begin{itemize}
 | ||
| % \item The variable you're assigning to is of a different type than the
 | ||
| % expression in the assignment.
 | ||
| % \item You are calling a function or procedure with parameters that are
 | ||
| % incompatible with the parameters in the function or procedure definition.
 | ||
| % \end{itemize}
 | ||
| type_e_incompatible_types=04001_E_Incompatibele typen: kreeg $1, verwachtte $2
 | ||
| % There is no conversion possible between the two types
 | ||
| % Another possiblity is that they are declared in different
 | ||
| % declarations:
 | ||
| % \begin{verbatim}
 | ||
| % Var
 | ||
| %    A1 : Array[1..10] Of Integer;
 | ||
| %    A2 : Array[1..10] Of Integer;
 | ||
| %
 | ||
| % Begin
 | ||
| %    A1:=A2; { This statement gives also this error, it
 | ||
| %              is due the strict type checking of pascal }
 | ||
| % End.
 | ||
| % \end{verbatim}
 | ||
| type_e_not_equal_types=04002_E_Typen komen niet overeen $1 en $2
 | ||
| % The types are not equal
 | ||
| type_e_type_id_expected=04003_E_Typesymbool verwacht
 | ||
| % The identifier is not a type, or you forgot to supply a type identifier.
 | ||
| type_e_variable_id_expected=04004_E_Variabelesymbool verwacht
 | ||
| % This happens when you pass a constant to a \var{Inc} var or \var{Dec}
 | ||
| % procedure. You can only pass variables as arguments to these functions.
 | ||
| type_e_integer_expr_expected=04005_E_Integerexpressie verwacht
 | ||
| % The compiler expects an expression of type integer, but gets a different
 | ||
| % type.
 | ||
| type_e_boolean_expr_expected=04006_E_Boolean waarde verwacht, kreeg echter "$1"
 | ||
| % The expression must be a boolean type, it should be return true or
 | ||
| % false.
 | ||
| type_e_ordinal_expr_expected=04007_E_Ordinale expressie verwacht
 | ||
| % The expression must be of ordinal type, i.e., maximum a \var{Longint}.
 | ||
| % This happens, for instance, when you specify a second argument
 | ||
| % to \var{Inc} or \var{Dec} that doesn't evaluate to an ordinal value.
 | ||
| type_e_pointer_type_expected=04008_E_Pointertype verwacht
 | ||
| % The variable or expression isn't of the type \var{pointer}. This
 | ||
| % happens when you pass a variable that isn't a pointer to \var{New}
 | ||
| % or \var{Dispose}.
 | ||
| type_e_class_type_expected=04009_E_Klassetype verwacht
 | ||
| % The variable of expression isn't of the type \var{class}. This happens
 | ||
| % typically when
 | ||
| % \begin{enumerate}
 | ||
| % \item The parent class in a class declaration isn't a class.
 | ||
| % \item An exception handler (\var{On}) contains a type identifier that
 | ||
| % isn't a class.
 | ||
| % \end{enumerate}
 | ||
| type_e_varid_or_typeid_expected=04010_E_Variabele- of typesymbool verwacht
 | ||
| % The argument to the \var{High} or \var{Low} function is not a variable
 | ||
| % nor a type identifier.
 | ||
| type_e_cant_eval_constant_expr=04011_E_Kan constante expressie niet evalueren
 | ||
| % No longer in use.
 | ||
| type_e_set_element_are_not_comp=04012_E_Elementen van set zijn niet compatible
 | ||
| % You are trying to make an operation on two sets, when the set element types
 | ||
| % are not the same. The base type of a set must be the same when taking the
 | ||
| % union
 | ||
| type_e_set_operation_unknown=04013_E_Bewerking niet ondersteund voor sets
 | ||
| % several binary operations are not defined for sets
 | ||
| % like div mod ** (also >= <= for now)
 | ||
| type_w_convert_real_2_comp=04014_W_Typeconversie van vlottende-komma type naar COMP, wat een integer type is.
 | ||
| % An implicit type conversion from a real type to a \var{comp} is
 | ||
| % encountered. Since \var{Comp} is a 64 bit integer type, this may indicate
 | ||
| % an error.
 | ||
| type_h_use_div_for_int=04015_H_Gebruik DIV voor gehele getallen om geheel resultaat te krijgen
 | ||
| % When hints are on, then an integer division with the '/' operator will
 | ||
| % procuce this message, because the result will then be of type real
 | ||
| type_e_strict_var_string_violation=04016_E_String typen stemmen niet overeen wegens de $V+ modus
 | ||
| % When compiling in \var{\{\$V+\}} mode, the string you pass as a parameter
 | ||
| % should be of the exact same type as the declared parameter of the procedure.
 | ||
| type_e_succ_and_pred_enums_with_assign_not_possible=04017_E_SUCC of PRED op enumeratietypen met toekenningen zijn niet mogelijk
 | ||
| % When you declared an enumeration type which has assignments in it, as in C,
 | ||
| % like in the following:
 | ||
| % \begin{verbatim}
 | ||
| %   Tenum = (a,b,e:=5);
 | ||
| % \end{verbatim}
 | ||
| % you cannot use the \var{Succ} or \var{Pred} functions on them.
 | ||
| type_e_cant_read_write_type=04018_E_Kan dit type variabelen niet lezen of schrijven
 | ||
| % You are trying to \var{read} or \var{write} a variable from or to a
 | ||
| % file of type text, which doesn't support that. Only integer types,
 | ||
| % booleans, reals, pchars and strings can be read from/written to a text file.
 | ||
| type_e_no_readln_writeln_for_typed_file=04019_E_Kan geen readln of writeln op getypeerde bestanden doen.
 | ||
| % \var{readln} and \var{writeln} are only allowed for text files.
 | ||
| type_e_no_read_write_for_untyped_file=04020_E_Kan geen read of write doen op ongetypeerde bestanden.
 | ||
| % \var{read} and \var{write} are only allowed for text or typed files.
 | ||
| type_e_typeconflict_in_set=04021_E_Typeconflict tussen setelementen.
 | ||
| % There is at least one set element which is of the wrong type, i.e. not of
 | ||
| % the set type.
 | ||
| type_w_maybe_wrong_hi_lo=04022_W_lo/hi(longint/dword) geeft hoog/laag (ipv byte) woord terug.
 | ||
| % \fpc supports an overloaded version of \var{lo/hi} for \var{longint/dword}
 | ||
| % which returns the lower/upper word of the argument. TP always uses
 | ||
| % a 16 bit \var{lo/hi} which returns always bits 0..7 for \var{lo} and the
 | ||
| % bits 8..15 for \var{hi}. If you want the TP behavior you have
 | ||
| % to type case the argument to \var{word/integer}
 | ||
| type_e_integer_or_real_expr_expected=04023_E_Integer of vlottende-komma uitdrukking verwacht
 | ||
| % The first argument to \var{str} must a real or integer type.
 | ||
| type_e_wrong_type_in_array_constructor=04024_E_Verkeerd type in array constructor
 | ||
| % You are trying to use a type in an array constructor which is not
 | ||
| % allowed.
 | ||
| type_e_wrong_parameter_type=04025_E_Incompatibel type voor argument #$1: kreeg $2, verwachtte $3
 | ||
| % You are trying to pass an invalid type for the specified parameter.
 | ||
| type_e_no_method_and_procedure_not_compatible=04026_E_Methode (variabele) en Procedure (variable) zijn niet compatible
 | ||
| % You can't assign a method to a procedure variable or a procedure to a
 | ||
| % method pointer.
 | ||
| type_e_wrong_math_argument=04027_E_Ongeldige constante opgegeven aan interne wiskundige functie
 | ||
| % The constant argument passed to a ln or sqrt function is out of
 | ||
| % the definition range of these functions.
 | ||
| type_e_no_addr_of_constant=04028_E_Een constante heeft geen adres
 | ||
| % It's not possible to get the address of a constant, because they
 | ||
| % aren't stored in memory, you can try making it a typed constant.
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Symtable
 | ||
| #
 | ||
| % \section{Symbol handling}
 | ||
| % This section lists all the messages that concern the handling of symbols.
 | ||
| % This means all things that have to do with procedure and variable names.
 | ||
| % \begin{description}
 | ||
| type_e_argument_cant_be_assigned=04029_E_Kan geen waarde toekennen aan argument
 | ||
| % Only expressions which can be on the left side of an
 | ||
| % assignment can be passed as call by reference argument
 | ||
| % Remark: Properties can be only
 | ||
| % used on the left side of an assignment, but they can't be used as arguments
 | ||
| type_e_cannot_local_proc_to_procvar=04030_E_Kan geen lokale procedure toekennen aan procedure variabele
 | ||
| % It's not allowed to assign a local procedure/function to a
 | ||
| % procedure variable, because the calling of local procedure/function is
 | ||
| % different. You can only assign local procedure/function to a void pointer.
 | ||
| type_e_no_assign_to_addr=04031_E_Kan geen waarde toekennen aan een adres
 | ||
| % It's not allowed to assign a value to an address of a variable,constant,
 | ||
| % procedure or function. You can try compiling with -So if the identifier
 | ||
| % is a procedure variable.
 | ||
| type_e_no_assign_to_const=04032_E_Kan geen waarde toekennen aan constante
 | ||
| % It's not allowed to assign a value to a variable which is declared
 | ||
| % as a const. This is normally a parameter declared as const, to allow
 | ||
| % changing make the parameter value or var.
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Symtable
 | ||
| #
 | ||
| % \section{Symbol handling}
 | ||
| % This section lists all the messages that concern the handling of symbols.
 | ||
| % This means all things that have to do with procedure and variable names.
 | ||
| % \begin{description}
 | ||
| sym_e_id_not_found=05000_E_Symbool niet gevonden $1
 | ||
| % The compiler doesn't know this symbol. Usually happens when you misspel
 | ||
| % the name of a variable or procedure, or when you forgot to declare a
 | ||
| % variable.
 | ||
| sym_f_internal_error_in_symtablestack=05001_F_Interne fout in SymTableStack()
 | ||
| % An internal error occurred in the compiler; If you encounter such an error,
 | ||
| % please contact the developers and try to provide  an exact description of
 | ||
| % the circumstances in which the error occurs.
 | ||
| sym_e_duplicate_id=05002_E_Dubbel symbool $1
 | ||
| % The identifier was already declared in the current scope.
 | ||
| sym_h_duplicate_id_where=05003_H_Symbool reeds gedefinieerd in $1 op lijn $2
 | ||
| % The identifier was already declared in a previous scope.
 | ||
| sym_e_unknown_id=05004_E_Onbekende symbool $1
 | ||
| % The identifier encountered hasn't been declared, or is used outside the
 | ||
| % scope where it's defined.
 | ||
| sym_e_forward_not_resolved=05005_E_Voorwaartse declaratie niet opgelost $1
 | ||
| % This can happen in two cases:
 | ||
| % \begin{itemize}
 | ||
| % \item This happens when you declare a function (in the \var{interface} part, or
 | ||
| % with a \var{forward} directive, but do not implement it.
 | ||
| % \item You reference a type which isn't declared in the current \var{type}
 | ||
| % block.
 | ||
| % \end{itemize}
 | ||
| sym_f_id_already_typed=05006_F_Typesymbool reeds gedefineerd als type
 | ||
| % You are trying to redefine a type.
 | ||
| sym_e_error_in_type_def=05007_E_Fout in type definitie
 | ||
| % There is an error in your definition of a new array type:
 | ||
| % \item One of the range delimiters in an array declaration is erroneous.
 | ||
| % For example, \var{Array [1..1.25]} will trigger this error.
 | ||
| sym_e_type_id_not_defined=05008_E_Typesymbool niet gedefinieerd
 | ||
| % The type identifier has not been defined yet.
 | ||
| sym_e_forward_type_not_resolved=05009_E_Forward declaratie niet opgelost $1
 | ||
| % The compiler encountered an unknown type.
 | ||
| sym_e_only_static_in_static=05010_E_Alleen statische variabelen kunnen gebruikt worden in statische methoden
 | ||
| % A static method of an object can only access static variables.
 | ||
| sym_e_invalid_call_tvarsymmangledname=05011_E_Ongeldige aanroep van tvarsym.mangledname()
 | ||
| % An internal error occurred in the compiler; If you encounter such an error,
 | ||
| % please contact the developers and try to provide  an exact description of
 | ||
| % the circumstances in which the error occurs.
 | ||
| sym_f_type_must_be_rec_or_class=05012_F_Record- of klassetype verwacht
 | ||
| % The variable or expression isn't of the type \var{record} or \var{class}.
 | ||
| sym_e_no_instance_of_abstract_object=05013_E_U kunt geen vertegenwoordiger van een klasse met abstracte methoden instantieren
 | ||
| % You are trying to generate an instance of a class which has an abstract
 | ||
| % method that wasn't overridden.
 | ||
| sym_w_label_not_defined=05014_W_Label niet gedefineerd $1
 | ||
| % A label was declared, but not defined.
 | ||
| sym_e_label_used_and_not_defined=05015_E_Label gebruikt maar niet gedefinieerd
 | ||
| % A label was declared and used, but not defined.
 | ||
| sym_e_ill_label_decl=05016_E_Label foutief gedefineerd
 | ||
| % This error should never happen; it occurs if a label is defined outside a
 | ||
| % procedure or function.
 | ||
| sym_e_goto_and_label_not_supported=05017_E_GOTO en LABEL zijn afgezet (gebruik -Sg)
 | ||
| % You must compile a program which has \var{label}s and \var{goto} statements
 | ||
| % with the  \var{-Sg} switch. By default, \var{label} and \var{goto} aren't
 | ||
| % supported.
 | ||
| sym_e_label_not_found=05018_E_Label niet gevonden
 | ||
| % A \var{goto label} was encountered, but the label isn't declared.
 | ||
| sym_e_id_is_no_label_id=05019_E_Symbool is geen label
 | ||
| % The identifier specified after the \var{goto} isn't of type label.
 | ||
| sym_e_label_already_defined=05020_E_Label is al gedefineerd
 | ||
| % You are defining a label twice. You can define a label only once.
 | ||
| sym_e_ill_type_decl_set=05021_E_Type declaratie van set elementen is foutief
 | ||
| % The declaration of a set contains an invalid type definition.
 | ||
| sym_e_class_forward_not_resolved=05022_E_Voorwaartse definitie van klasse niet opgelost $1
 | ||
| % You declared a class, but you didn't implement it.
 | ||
| sym_n_unit_not_used=05023_H_Unit $1 wordt niet gebruikt in $2
 | ||
| % The unit referenced in the \var{uses} clause is not used.
 | ||
| sym_h_para_identifier_not_used=05024_H_Parameter niet gebruikt $1
 | ||
| % This is a warning. The identifier was declared (locally or globally) but
 | ||
| % wasn't used (locally or globally).
 | ||
| sym_n_local_identifier_not_used=05025_N_Lokale variabele niet gebruikt $1
 | ||
| % You have declared, but not used a variable in a procedure or function
 | ||
| % implementation.
 | ||
| sym_h_para_identifier_only_set=05026_H_Waarde parameter $1 is gedeclareerd maar niet gebruikt.
 | ||
| % This is a warning. The identifier was declared (locally or globally)
 | ||
| % set but not used (locally or globally).
 | ||
| sym_n_local_identifier_only_set=05027_N_Lokale variabele $1 gedeclareerd maar niet gebruikt.
 | ||
| % The variable in a procedure or function
 | ||
| % implementation is declared, set but never used.
 | ||
| sym_h_local_symbol_not_used=05028_H_Lokaal $1 $2 is niet gebruikt
 | ||
| % A local symbol is never used.
 | ||
| sym_n_private_identifier_not_used=05029_N_Privaat veld $1.$2 wordt niet gebruikt
 | ||
| sym_n_private_identifier_only_set=05030_N_Privaat veld $1.$2 gedeclareerd maar niet gebruikt.
 | ||
| sym_n_private_method_not_used=05031_N_Private methode $1.$2 wordt nooit gebruikt.
 | ||
| 
 | ||
| 
 | ||
| sym_e_set_expected=05032_E_Set type verwacht
 | ||
| % The variable or expression isn't of type \var{set}. This happens in an
 | ||
| % \var{in} statement.
 | ||
| sym_w_function_result_not_set=05033_W_Resultaat van functie lijkt niet te zijn toegekend
 | ||
| % You can get this warning if the compiler thinks that a function return
 | ||
| % value is not set. This will not be displayed for assembler procedures,
 | ||
| % or procedures that contain assembler blocks.
 | ||
| sym_w_wrong_C_pack=05034_W_Type $1 is not aligned correctly in current record for C
 | ||
| % Arrays with sizes not multiples of 4 will be wrongly aligned
 | ||
| % for C structures.
 | ||
| sym_e_illegal_field=05035_E_Onbekend record lid $1
 | ||
| % The field doesn't exist in the record definition.
 | ||
| sym_n_uninitialized_local_variable=05036_N_Locale variabele $1 lijkt niet geinitialiseerd te zijn
 | ||
| sym_n_uninitialized_variable=05037_W_Variabele $1 lijkt niet geinitialiseerd te zijn
 | ||
| % These messages are displayed if the compiler thinks that a variable will
 | ||
| % be used (i.e. appears in the right-hand-side of an expression) when it
 | ||
| % wasn't initialized first (i.e. appeared in the left-hand side of an
 | ||
| % assigment)
 | ||
| sym_e_id_no_member=05038_E_Geen lid met de naam $1
 | ||
| % When using the extended syntax of \var{new}, you must specify the constructor
 | ||
| % method of the class you are trying to create. The procedure you specified
 | ||
| % does not exist.
 | ||
| sym_b_param_list=05039_B_Declaratie gevonden: $1
 | ||
| % You get this when you use the \var{-vb} switch. In case an overloaded
 | ||
| % procedure is not found, then all candidate overloaded procedures are
 | ||
| % listed, with their parameter lists.
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Codegenerator
 | ||
| #
 | ||
| % \section{Code generator messages}
 | ||
| % This section lists all messages that can be displayed if the code
 | ||
| % generator encounters an error condition.
 | ||
| % \begin{description}
 | ||
| sym_e_segment_too_large=05040_E_Data segment te groot (max. 2GB)
 | ||
| % You get this when you declare an array whose size exceeds the 2GB limit.
 | ||
| % \end{description}
 | ||
| #
 | ||
| # Codegenerator
 | ||
| #
 | ||
| % \section{Code generator messages}
 | ||
| % This section lists all messages that can be displayed if the code
 | ||
| % generator encounters an error condition.
 | ||
| % \begin{description}
 | ||
| cg_e_break_not_allowed=06000_E_BREAK niet toegelaten
 | ||
| % You're trying to use \var{break} outside a loop construction.
 | ||
| cg_e_continue_not_allowed=06001_E_CONTINUE niet toegelaten
 | ||
| % You're trying to use \var{continue} outside a loop construction.
 | ||
| cg_e_too_complex_expr=06002_E_Uitdrukking te ingewikkeld - overloop van wiskundige processor
 | ||
| % Your expression is too long for the compiler. You should try dividing the
 | ||
| % construct over multiple assignments.
 | ||
| cg_e_illegal_expression=06003_E_Foutieve uitdrukking
 | ||
| % This can occur under many circumstances. Mostly when trying to evaluate
 | ||
| % constant expressions.
 | ||
| cg_e_invalid_integer=06004_E_Foutieve gehele uitdruking
 | ||
| % You made an expression which isn't an integer, and the compiler expects the
 | ||
| % result to be an integer.
 | ||
| cg_e_invalid_qualifier=06005_E_Ongeldige constructie
 | ||
| % One of the following is happening :
 | ||
| % \begin{itemize}
 | ||
| % \item You're trying to access a field of a variable that is not a record.
 | ||
| % \item You're indexing a variable that is not an array.
 | ||
| % \item You're dereferencing a variable that is not a pointer.
 | ||
| % \end{itemize}
 | ||
| cg_e_upper_lower_than_lower=06006_E_Bovengrens is kleiner dan ondergrens
 | ||
| % You are declaring a subrange, and the lower limit is higher than the high
 | ||
| % limit of the range.
 | ||
| cg_e_illegal_count_var=06007_E_Ongeldige lusteller
 | ||
| % The type of a \var{for} loop variable must be an ordinal type.
 | ||
| % Loop variables cannot be reals or strings.
 | ||
| cg_e_cant_choose_overload_function=06008_E_Weet niet welke overroepen procedure moet worden aangeroepen
 | ||
| % You're calling overloaded functions with a parameter that doesn't correspond
 | ||
| % to any of the declared function parameter lists. e.g. when you have declared
 | ||
| % a function with parameters \var{word} and \var{longint}, and then you call
 | ||
| % it with a parameter which is of type \var{integer}.
 | ||
| cg_e_parasize_too_big=06009_E_Parameters gebruiken meer dan 64 kilobyte
 | ||
| % The I386 processor limits the parameter list to 65535 bytes (the \var{RET}
 | ||
| % instruction causes this)
 | ||
| cg_e_illegal_type_conversion=06010_E_Foute typeconversie
 | ||
| % When doing a type-cast, you must take care that the sizes of the variable and
 | ||
| % the destination type are the same.
 | ||
| cg_d_pointer_to_longint_conv_not_portable=06011_D_Conversie tussen ordinale en pointertypen is niet overdraagbaar naar andere processoren
 | ||
| % If you typecast a pointer to a longint, this code will not compile
 | ||
| % on a machine using 64bit for pointer storage.
 | ||
| cg_e_file_must_call_by_reference=06012_E_File variabelen moeten altijd var parameters zijn
 | ||
| % You cannot specify files as value parameters, i.e. they must always be
 | ||
| % declared \var{var} parameters.
 | ||
| cg_e_cant_use_far_pointer_there=06013_E_U kunt daar geen far pointer gebruiken
 | ||
| % Free Pascal doesn't support far pointers, so you cannot take the address of
 | ||
| % an expression which has a far reference as a result. The \var{mem} construct
 | ||
| % has a far reference as a result, so the following code will produce this
 | ||
| % error:
 | ||
| % \begin{verbatim}
 | ||
| % var p : pointer;
 | ||
| % ...
 | ||
| % p:=@mem[a000:000];
 | ||
| % \end{verbatim}
 | ||
| cg_e_var_must_be_reference=06014_E_Ongeldige aanroep met referentie parameters
 | ||
| % You are trying to pass a constant or an expression to a procedure that
 | ||
| % requires a \var{var} parameter. Only variables can be passed as a \var{var}
 | ||
| % parameter.
 | ||
| cg_e_dont_call_exported_direct=06015_E_Procedures die als EXPORT gedeclareerd staan kunnen niet aangeroepen worden
 | ||
| % No longer in use.
 | ||
| cg_w_member_cd_call_from_method=06016_W_Mogelijke ongeldige aanroep van constructor of destructor
 | ||
| % No longer in use.
 | ||
| cg_n_inefficient_code=06017_N_Inefficiente code
 | ||
| % You construction seems dubious to the compiler.
 | ||
| cg_w_unreachable_code=06018_W_Deze code wordt nooit uitgevoerd
 | ||
| % You specified a loop which will never be executed. Example:
 | ||
| % \begin{verbatim}
 | ||
| % while false do
 | ||
| %   begin
 | ||
| %   {.. code ...}
 | ||
| %   end;
 | ||
| % \end{verbatim}
 | ||
| cg_e_stackframe_with_esp=06019_E_Procedure aanroep met stackframe ESP/SP
 | ||
| % The compiler encountered a procedure  or function call inside a
 | ||
| % procedure that uses a \var{ESP/SP} stackframe. Normally, when a call is
 | ||
| % done the procedure needs a \var{EBP} stackframe.
 | ||
| cg_e_cant_call_abstract_method=06020_E_Abstracte methoden kunnen niet direct aangeroepen worden
 | ||
| % You cannot call an abstract method directy, instead you must call a
 | ||
| % overriding child method, because an abstract method isn't implemented.
 | ||
| cg_f_internal_error_in_getfloatreg=06021_F_Interne fout in getfloatreg(), allocatie faling
 | ||
| % An internal error occurred in the compiler; If you encounter such an error,
 | ||
| % please contact the developers and try to provide  an exact description of
 | ||
| % the circumstances in which the error occurs.
 | ||
| cg_f_unknown_float_type=06022_F_Onbekend vlottende-komma type
 | ||
| % The compiler cannot determine the kind of float that occurs in an expression.
 | ||
| cg_f_secondvecn_base_defined_twice=06023_F_SecondVecn() basis tweemaal gedefinieerd.
 | ||
| % An internal error occurred in the compiler; If you encounter such an error,
 | ||
| % please contact the developers and try to provide  an exact description of
 | ||
| % the circumstances in which the error occurs.
 | ||
| cg_f_extended_cg68k_not_supported=06024_F_Extended cg68k niet ondersteund
 | ||
| % The var{extended} type is not supported on the m68k platform.
 | ||
| cg_f_32bit_not_supported_in_68000=06025_F_32-bit unsigned niet ondersteund in MC68000 modus
 | ||
| % The cardinal is not supported on the m68k platform.
 | ||
| cg_f_internal_error_in_secondinline=06026_F_Interne fout in secondinline()
 | ||
| % An internal error occurred in the compiler; If you encounter such an error,
 | ||
| % please contact the developers and try to provide  an exact description of
 | ||
| % the circumstances in which the error occurs.
 | ||
| cg_d_register_weight=06027_D_Register $1 gewicht $2 $3
 | ||
| % Debugging message. Shown when the compiler considers a variable for
 | ||
| % keeping in the registers.
 | ||
| cg_e_stacklimit_in_local_routine=06028_E_Stacklimiet overschreden in lokale routine
 | ||
| % Your code requires a too big stack. Some operating systems pose limits
 | ||
| % on the stack size. You should use less variables or try ro put large
 | ||
| % variables on the heap.
 | ||
| cg_d_stackframe_omited=06029_D_Stackframe wordt niet gemaakt
 | ||
| % Some procedure/functions do not need a complete stack-frame, so it is omitted.
 | ||
| % This message will be displayed when the {-vd} switch is used.
 | ||
| cg_w_64bit_range_check_not_supported=06030_W_bereik check voor 64 bit integer is niet ondersteund op dit platform
 | ||
| % 64 bit range check is not yet implemented for 32 bit processors.
 | ||
| cg_e_unable_inline_object_methods=06031_E_Kan inline niet gebruiken voor object methoden
 | ||
| % You cannot have inlined object methods.
 | ||
| cg_e_unable_inline_procvar=06032_E_Kan inline niet gebruiken voor procvar aanroepen
 | ||
| % A procedure with a procedural variable call cannot be inlined.
 | ||
| cg_e_no_code_for_inline_stored=06033_E_Geen code voor inline procedure opgeslagen
 | ||
| % The compiler couldn't store code for the inline procedure.
 | ||
| cg_e_no_call_to_interrupt=06034_E_Directe oproep van interrupt procedure $1 is niet mogelijk
 | ||
| % You can not call an interrupt procedure directly from FPC code
 | ||
| cg_e_can_access_element_zero=06035_E_Element nul van een ansi/wide- of longstring is niet toegankelijk, gebruik (set)length.
 | ||
| % You should use \var{setlength} to set the length of an ansi/wide/longstring
 | ||
| % and \var{length} to get the length of such kinf of string
 | ||
| cg_e_include_not_implemented=06036_E_Include en exclude niet ondersteund in dit geval
 | ||
| % \var{include} and \var{exclude} are only partially
 | ||
| % implemented for \var{i386} processors
 | ||
| % and not at all for \var{m68k} processors.
 | ||
| cg_e_cannot_call_cons_dest_inside_with=06037_E_Constructors of destructors kunnen niet aangeroepen worden binnen een 'with' clausule
 | ||
| % Inside a \var{With} clause you cannot call a constructor or destructor for the
 | ||
| % object you have in the \var{with} clause.
 | ||
| cg_e_cannot_call_message_direct=06038_E_Een message handler methode kan niet direct aangeroepen worden.
 | ||
| % A message method handler method can't be called directly if it contains an
 | ||
| % explicit self argument
 | ||
| % \end{description}
 | ||
| # EndOfTeX
 | ||
| #
 | ||
| # Assembler reader
 | ||
| #
 | ||
| cg_e_goto_inout_of_exception_block=06039_E_Sprong in of uit een exception blok
 | ||
| % It isn't allowed to jump in or outside of an exception block like \var{try..finally..end;}:
 | ||
| % \begin{verbatim}
 | ||
| % label 1;
 | ||
| %
 | ||
| % ...
 | ||
| %
 | ||
| % try
 | ||
| %    if not(final) then
 | ||
| %      goto 1;   // this line will cause an error
 | ||
| % finally
 | ||
| %   ...
 | ||
| % end;
 | ||
| % 1:
 | ||
| % ...
 | ||
| % \end{verbatim}
 | ||
| % \end{description}
 | ||
| cg_e_control_flow_outside_finally=06040_E_Control flow statements niet toegestaan in een finally blok
 | ||
| % It isn't allowed to use the control flow statements \var{break},
 | ||
| % \var{continue} and \var{exit}
 | ||
| % inside a finally statement. The following example shows the problem:
 | ||
| % \begin{verbatim}
 | ||
| % ...
 | ||
| %   try
 | ||
| %      p;
 | ||
| %   finally
 | ||
| %      ...
 | ||
| %      exit;  // This exit ISN'T allowed
 | ||
| %   end;
 | ||
| % ...
 | ||
| %
 | ||
| % \end{verbatim}
 | ||
| % If the procedure \var{p} raises an exception the finally block is
 | ||
| % executed. If the execution reaches the exit, it's unclear what to do:
 | ||
| % exiting the procedure or searching for another exception handler
 | ||
| # EndOfTeX
 | ||
| asmr_d_start_reading=07000_D_Begonnen met verwerken van $1 assembler
 | ||
| % This informs you that an assembler block is being parsed
 | ||
| asmr_d_finish_reading=07001_D_Gedaan met verwerken van $1 assembler
 | ||
| % This informs you that an assembler block has finished.
 | ||
| asmr_e_none_label_contain_at=07002_E_Symbool dat geen label is bevat "@"
 | ||
| % A identifier which isn't a label can't contain a @.
 | ||
| asmr_w_override_op_not_supported=07003_W_De "override" operator wordt niet ondersteund
 | ||
| % The Override operator is not supported
 | ||
| asmr_e_building_record_offset=07004_E_Fout bij berekenen offset in record
 | ||
| % There has an error occured while building the offset of a record/object
 | ||
| % structure, this can happend when there is no field specified at all or
 | ||
| % an unknown field identifier is used.
 | ||
| asmr_e_offset_without_identifier=07005_E_OFFSET gebruikt zonder symbool
 | ||
| % You can only use OFFSET with an identifier. Other syntaxes aren't
 | ||
| % supported
 | ||
| asmr_e_type_without_identifier=07006_E_TYPE gebruikt zonder symbool
 | ||
| % You can only use TYPE with an identifier. Other syntaxes aren't
 | ||
| % supported
 | ||
| asmr_e_no_local_or_para_allowed=07007_E_Kan hier geen lokale variabele of parameter gebruiken
 | ||
| % You can't use a local variable or parameter here, mostly because the
 | ||
| % addressing of locals and parameters is done using the %ebp register so the
 | ||
| % address can't be get directly.
 | ||
| asmr_e_need_offset=07008_E_OFFSET moet hier gebruikt worden
 | ||
| % You need to use OFFSET <id> here to get the address of the identifier.
 | ||
| asmr_e_need_dollar=07009_E_Gebruik van $ is hier verplicht
 | ||
| % You need to use $<id> here to get the address of the identifier.
 | ||
| asmr_e_cant_have_multiple_relocatable_symbols=07010_E_Kan niet meerdere verplaatsbare symbolen gebruiken
 | ||
| % You can't have more than one relocatable symbol (variable/typed constant)
 | ||
| % in one argument.
 | ||
| asmr_e_only_add_relocatable_symbol=07011_E_Een verplaatsbaar symbool kan enkel toegevoegd worden
 | ||
| % Relocatable symbols (variable/typed constant) can't be used with other
 | ||
| % operators. Only addition is allowed.
 | ||
| asmr_e_invalid_constant_expression=07012_E_Ongeldige constante uitdrukking
 | ||
| % There is an error in the constant expression.
 | ||
| asmr_e_relocatable_symbol_not_allowed=07013_E_Verplaatsbaar symbool niet toegelaten
 | ||
| % You can't use a relocatable symbol (variable/typed constant) here.
 | ||
| asmr_e_invalid_reference_syntax=07014_E_Ongeldige geheugenlocatie schrijfwijze
 | ||
| % There is an error in the reference.
 | ||
| asmr_e_local_para_unreachable=07015_E_$1 niet bereikbaar vanuit deze code
 | ||
| % You can not read directly the value of local or para
 | ||
| % of a higher level in assembler code (except for
 | ||
| % local assembler code without parameter nor locals).
 | ||
| asmr_e_local_label_not_allowed_as_ref=07016_E_Lokale symbolen/labels niet toegestaan als referenties
 | ||
| % You can't use local symbols/labels as references
 | ||
| asmr_e_wrong_base_index=07017_E_Ongeldig gebruik van basis en index register
 | ||
| % There is an error with the base and index register
 | ||
| asmr_w_possible_object_field_bug=07018_W_Mogelijke fout in behandeling velden van object.
 | ||
| % Fields of objects or classes can be reached directly in normal or objfpc
 | ||
| % modes but TP and Delphi modes treat the field name as a simple offset.
 | ||
| asmr_e_wrong_scale_factor=07019_E_Ongeldige schaalfactor
 | ||
| % The scale factor given is wrong, only 1,2,4 and 8 are allowed
 | ||
| asmr_e_multiple_index=07020_E_Meervoudig indexregister gebruik
 | ||
| % You are trying to use more than one index register
 | ||
| asmr_e_invalid_operand_type=07021_E_Ongeldig operandus type
 | ||
| % The operand type doesn't match with the opcode used
 | ||
| asmr_e_invalid_string_as_opcode_operand=07022_E_Ongeldige tekenreeks als instructie operandus: $1
 | ||
| % The string specified as operand is not correct with this opcode
 | ||
| asmr_w_CODE_and_DATA_not_supported=07023_W_@CODE en @DATA worden niet ondersteund
 | ||
| % @CODE and @DATA are unsupported and are ignored.
 | ||
| asmr_e_null_label_ref_not_allowed=07024_E_Null label verwijzingen zijn niet toegelaten
 | ||
| asmr_e_expr_zero_divide=07025_E_Deling door nul
 | ||
| asmr_e_expr_illegal=07026_E_Ongeldige uitdrukking
 | ||
| asmr_e_escape_seq_ignored=07027_E_Expliciete reeks genegeerd: $1
 | ||
| asmr_e_invalid_symbol_ref=07028_E_Ongeldige symboolverwijzing
 | ||
| asmr_w_fwait_emu_prob=07029_W_Fwait kan emulatieproblemen met emu387 veroorzaken
 | ||
| asmr_w_fadd_to_faddp=07030_W_FADD zonder operand vertaald naar FADDP
 | ||
| asmr_w_enter_not_supported_by_linux=07031_W_De ENTER instructie wordt niet ondersteund door de Linux kernel
 | ||
| % ENTER instruction can generate a stack page fault that is not
 | ||
| % caught correctly by the i386 Linux page handler.
 | ||
| asmr_w_calling_overload_func=07032_W_Een overroepen functie wordt aangeroepen vanuit assemblercode
 | ||
| asmr_e_unsupported_symbol_type=07033_E_Niet ondersteund symbool type voor operandus
 | ||
| asmr_e_constant_out_of_bounds=07034_E_Constante waarde valt buiten bereik
 | ||
| asmr_e_error_converting_decimal=07035_E_Fout bij omzetten van decimaal getal $1
 | ||
| asmr_e_error_converting_octal=07036_E_Fout bij omzetten van octaal getal $1
 | ||
| asmr_e_error_converting_binary=07037_E_Fout bij omzetten van binair getal $1
 | ||
| asmr_e_error_converting_hexadecimal=07038_E_Fout bij omzetten van hexadecimaal getal $1
 | ||
| asmr_h_direct_global_to_mangled=07039_H_$1 vertaald naar $2
 | ||
| asmr_w_direct_global_is_overloaded_func=07040_W_$1 is geassocieerd met een overroepen functie
 | ||
| asmr_e_cannot_use_SELF_outside_a_method=07041_E_Kan SELF niet buiten een methode gebruiken
 | ||
| asmr_e_cannot_use_OLDEBP_outside_nested_procedure=07042_E_Kan OLDEBP niet buiten een genestelde procedure gebruiken
 | ||
| asmr_e_void_function=07043_W_Functies met een ongedefinieerde teruggeefwaarde kunnen geen waarde teruggeven
 | ||
| asmr_e_SEG_not_supported=07044_E_SEG not supported
 | ||
| asmr_e_size_suffix_and_dest_dont_match=07045_E_Grootte-achtervoegsel en doel- of brongrootte komen niet overeen
 | ||
| asmr_w_size_suffix_and_dest_dont_match=07046_W_Grootte-achtervoegsel en doel- of brongrootte komen niet overeen
 | ||
| asmr_e_syntax_error=07047_E_Assembler taalfout
 | ||
| asmr_e_invalid_opcode_and_operand=07048_E_Ongeldige combinatie van instructie en operandi
 | ||
| asmr_e_syn_operand=07049_E_Assembler taalfout in operandum
 | ||
| asmr_e_syn_constant=07050_E_Assembler taalfout in constante
 | ||
| asmr_e_invalid_string_expression=07051_E_Ongeldige String uitdrukking
 | ||
| asmr_w_const32bit_for_address=07052_ bits constante gemaakt voor adres
 | ||
| asmr_e_unknown_opcode=07053_E_Ongekende opcode $1
 | ||
| asmr_e_invalid_or_missing_opcode=07054_E_Ongeldige of ontbrekende instructie
 | ||
| asmr_e_invalid_prefix_and_opcode=07055_E_Ongeldige combinatie van voorvoegsel en instructie: $1
 | ||
| asmr_e_invalid_override_and_opcode=07056_E_Ongeldige combinatie van segment overroeping en instructie: $1
 | ||
| asmr_e_too_many_operands=07057_E_Te veel operandi op een lijn
 | ||
| asmr_w_near_ignored=07058_W_NEAR genegeerd
 | ||
| asmr_w_far_ignored=07059_W_FAR genegeerd
 | ||
| asmr_e_dup_local_sym=07060_E_Dubbel lokaal symbool $1
 | ||
| asmr_e_unknown_local_sym=07061_E_Niet gedefinieerd lokaal symbool $1
 | ||
| asmr_e_unknown_label_identifier=07062_E_Onbekende labelnaam $1
 | ||
| asmr_e_invalid_register=07063_E_Ongeldige register naam
 | ||
| asmr_e_invalid_fpu_register=07064_E_Ongeldig vlottende-komma registernaam
 | ||
| asmr_e_nor_not_supported=07065_E_NOR wordt niet ondersteund
 | ||
| asmr_w_modulo_not_supported=07066_W_Modulo wordt niet ondersteund
 | ||
| asmr_e_invalid_float_const=07067_E_Ongeldige vlottende-komma constante $1
 | ||
| asmr_e_invalid_float_expr=07068_E_Ongeldige vlottende-komma uitdrukking
 | ||
| asmr_e_wrong_sym_type=07069_E_Verkeerd symbool type
 | ||
| asmr_e_cannot_index_relative_var=07070_E_Een lokale variabele of parameter kan niet geindedxeerd worden met een register
 | ||
| asmr_e_invalid_seg_override=07071_E_Ongeldige segment overroeping
 | ||
| asmr_w_id_supposed_external=07072_W_Symbool $1 wordt verondersteld extern te zijn
 | ||
| asmr_e_string_not_allowed_as_const=07073_E_Strings zijn niet toegelaten als constante
 | ||
| asmr_e_no_var_type_specified=07074_Geen type van de variabele gegeven
 | ||
| asmr_w_assembler_code_not_returned_to_text=07075_E_De assembler code stopt niet in een '.text' gedeelte
 | ||
| asmr_e_not_directive_or_local_symbol=07076_E_Geen aanwijzing of lokaal symbool $1
 | ||
| asmr_w_using_defined_as_local=07077_E_Een gedfinieerde naam wordt gebruikt als assembler label
 | ||
| 
 | ||
| #
 | ||
| # Assembler/binary writers
 | ||
| #
 | ||
| asmr_e_dollar_without_identifier=07078_E_Dollar teken gebruikt zonder identifier
 | ||
| asmr_w_32bit_const_for_address=07079_W_32bit constante aangemaakt voor adres
 | ||
| asmr_n_align_is_target_specific=07080_N_.align is doel specifiek, gebruik .balign of .p2align
 | ||
| asmr_e_cannot_access_field_directly_for_parameters=07081_E_Kan velden niet direct gebruiken voor parameters.
 | ||
| % You should load the parameter first into a register and then access the
 | ||
| % fields using that register.
 | ||
| asmr_e_cannot_access_object_field_directly=07082_E_Kan velden van objecten/klassen niet direct aanspreken
 | ||
| % You should load the self pointer first into a register and then access the
 | ||
| % fields using the register as base. By default the self pointer is available
 | ||
| % in the esi register on i386.
 | ||
| #
 | ||
| # Assembler/binary writers
 | ||
| #
 | ||
| asmw_f_too_many_asm_files=08000_F_Te veel assemblerbestanden
 | ||
| asmw_f_assembler_output_not_supported=08001_F_De geselecteerde assembler modus wordt hier niet ondersteund
 | ||
| asmw_f_comp_not_supported=08002_F_Het COMP type wordt hier niet ondersteund
 | ||
| asmw_f_direct_not_supported=08003_F_Directe assembler modus wordt niet ondersteund door de binaire assemblerschrijver
 | ||
| asmw_e_alloc_data_only_in_bss=08004_E_Ruimte voor gegevens reserveren mag enkel in een bss gedeelte
 | ||
| asmw_f_no_binary_writer_selected=08005_F_Binaire assemblerschrijver geselecteerd
 | ||
| asmw_e_opcode_not_in_table=08006_E_Asm: Opcode $1 not gevonden in interne tabel
 | ||
| asmw_e_invalid_opcode_and_operands=08007_E_Asm: $1 Ongeldige combinatie van instructie en operandi
 | ||
| asmw_e_16bit_not_supported=08008_E_Asm: 16 Bit geheugenlocaties worden niet ondersteund
 | ||
| asmw_e_invalid_effective_address=08009_E_Asm: Ongeldig direct adres
 | ||
| asmw_e_immediate_or_reference_expected=08010_E_Asm: Constante of geheugenadres verwacht
 | ||
| asmw_e_value_exceeds_bounds=08011_E_Asm: $1 waarde overschrijdt grenzen van $2
 | ||
| asmw_e_short_jmp_out_of_range=08012_E_Asm: Korte spronginstructie gaat te ver $1
 | ||
| 
 | ||
| #
 | ||
| # Executing linker/assembler
 | ||
| #
 | ||
| asmw_e_undefined_label=08013_E_Asm: Ongedefinieerd label $1
 | ||
| 
 | ||
| 
 | ||
| #
 | ||
| # Executing linker/assembler
 | ||
| #
 | ||
| # BeginOfTeX
 | ||
| %
 | ||
| % \section{Errors of assembling/linking stage}
 | ||
| % This section lists errors that occur when the compiler is processing the
 | ||
| % command line or handling the configuration files.
 | ||
| % \begin{description}
 | ||
| exec_w_source_os_redefined=09000_W_Bronbesturingssysteem geherdefinieerd
 | ||
| exec_i_assembling_pipe=09001_I_Assembleren (pijp) van $1
 | ||
| exec_d_cant_create_asmfile=09002_E_Kan geen assembler bestand $1 niet maken
 | ||
| % The mentioned file can't be create. Check if you've
 | ||
| % permission to create this file
 | ||
| exec_e_cant_create_objectfile=09003_E_Kan geen object bestand openen: $1
 | ||
| % The mentioned file can't be create. Check if you've
 | ||
| % permission to create this file
 | ||
| exec_e_cant_create_archivefile=09004_E_kan geen archief bestand openen: $1
 | ||
| % The mentioned file can't be create. Check if you've
 | ||
| % permission to create this file
 | ||
| exec_w_assembler_not_found=09005_W_Assembler $1 niet gevonden, overschakeling naar externe assemblage
 | ||
| exec_t_using_assembler=09006_T_Gebruikte assembler: $1
 | ||
| exec_w_error_while_assembling=09007_W_Fout bij assembleren
 | ||
| exec_w_cant_call_assembler=09008_W_Kan assembleerder niet oproepen, overschakeling naar externe assemblage
 | ||
| exec_i_assembling=09009_I_Assembleren van $1
 | ||
| exec_i_assembling_smart=09010_I_Assembleren slim-link $1
 | ||
| exec_w_objfile_not_found=09011_E_Bestand $1 niet gevonden, linken kan foutlopen !
 | ||
| exec_w_libfile_not_found=09012_E_Bibliotheek $1 niet gevonden, linken kan foutlopen !
 | ||
| exec_w_error_while_linking=09013_W_Fout tijdens linken
 | ||
| exec_w_cant_call_linker=09014_W_Kan linker niet oproepen, overschakeling naar extern linken
 | ||
| exec_i_linking=09015_I_Linken van $1
 | ||
| exec_w_util_not_found=09016_W_Tool $1 niet gevonden, schakel over op extern linken.
 | ||
| exec_t_using_util=09017_T_Gebruik tool $1
 | ||
| exec_e_exe_not_supported=09018_E_Creatie van executable bestanden niet ondersteund.
 | ||
| exec_e_dll_not_supported=09019_E_Dynamische bibliotheken niet ondersteund
 | ||
| exec_i_closing_script=09020_I_Afsluiten batch $1
 | ||
| exec_w_res_not_found=09021_W_resource compiler niet gevonden, ga over op externe modus
 | ||
| exec_i_compilingresource=09022_I_Compileer resource $1
 | ||
| #
 | ||
| # Executable information
 | ||
| #
 | ||
| execinfo_f_cant_process_executable=09023_F_Kan applicatie niet nabehandelen $1
 | ||
| execinfo_f_cant_open_executable=09024_F_Kan applicatie niet openen $1
 | ||
| execinfo_x_codesize=09025_X_Grootte van de code: $1 bytes
 | ||
| execinfo_x_initdatasize=09026_X_Grootte van geinitialiseerde data: $1 bytes
 | ||
| execinfo_x_uninitdatasize=09027_X_Grootte van niet-geinitialiseerde data: $1 bytes
 | ||
| execinfo_x_stackreserve=09028_X_Gereserveerde stackruimte: $1 bytes
 | ||
| execinfo_x_stackcommit=09029_X_Toegewezen stackruimte: $1 bytes
 | ||
| # Unit loading
 | ||
| #
 | ||
| # BeginOfTeX
 | ||
| % \section{Unit loading messages.}
 | ||
| % This section lists all messages that can occur when the compiler is
 | ||
| % loading a unit from disk into memory. Many of these mesages are
 | ||
| % informational messages.
 | ||
| % \begin{description}
 | ||
| unit_t_unitsearch=10000_T_Unit zoeken: $1
 | ||
| % When you use the \var{-vt}, the compiler tells you where it tries to find
 | ||
| % unit files.
 | ||
| unit_t_ppu_loading=10001_U_PPU Laden $1
 | ||
| % When the \var{-vt} switch is used, the compiler tells you
 | ||
| % what units it loads.
 | ||
| unit_u_ppu_name=10002_U_PPU Naam: $1
 | ||
| % When you use the \var{-vu} flag, the unit name is shown.
 | ||
| unit_u_ppu_flags=10003_D_PPU Vlaggen: $1
 | ||
| % When you use the \var{-vu} flag, the unit flags are shown.
 | ||
| unit_u_ppu_crc=10004_D_PPU CRC: $1
 | ||
| % When you use the \var{-vu} flag, the unit CRC check is shown.
 | ||
| unit_u_ppu_time=10005_D_PPU Tijd: $1
 | ||
| % When you use the \var{-vu} flag, the unit time is shown.
 | ||
| unit_u_ppu_file_too_short=10006_D_PPU bestand te kort
 | ||
| % When you use the \var{-vu} flag, the unit time is shown.
 | ||
| unit_u_ppu_invalid_header=10007_D_PPU Ongeldige kop (geen PPU aan het begin)
 | ||
| % A unit file contains as the first three bytes the ascii codes of \var{PPU}
 | ||
| unit_u_ppu_invalid_version=10008_D_PPU Ongeldige versie $1
 | ||
| % This unit file was compiled with a different version of the compiler, and
 | ||
| % cannot be read.
 | ||
| unit_u_ppu_invalid_processor=10009_U_PPU is gecompileerd voor een andere processor
 | ||
| % This unit file was compiled for a different processor type, and
 | ||
| % cannot be read
 | ||
| unit_u_ppu_invalid_target=10010_U_PPU is gecompileerd voor een ander doelsysteem
 | ||
| % This unit file was compiled for a different processor type, and
 | ||
| % cannot be read
 | ||
| unit_u_ppu_source=10011_U_PPU bron: $1
 | ||
| % When you use the \var{-vu} flag, the unit CRC check is shown.
 | ||
| unit_u_ppu_write=10012_U_Schrijven van $1
 | ||
| % When you specify the \var{-vu} switch, the compiler will tell you where it
 | ||
| % writes the unit file.
 | ||
| unit_f_ppu_cannot_write=10013_F_Kan PPU bestand niet schrijven
 | ||
| % An err
 | ||
| unit_f_ppu_read_error=10014_F_Lezen van PPU bestand
 | ||
| % Unexpected end of file
 | ||
| unit_f_ppu_read_unexpected_end=10015_F_Onverwacht einde van PPU-bestand
 | ||
| % This means that the unit file was corrupted, and contains invalid
 | ||
| % information. Recompilation will be necessary.
 | ||
| unit_f_ppu_invalid_entry=10016_F_Ongeldig PPU bestand post: $1
 | ||
| % The unit the compiler is trying to read is corrupted, or generated with a
 | ||
| % newer version of the compiler.
 | ||
| unit_f_ppu_dbx_count_problem=10017_F_PPU Dbx aantal probleem
 | ||
| % There is an inconsistency in the debugging information of the unit.
 | ||
| unit_e_illegal_unit_name=10018_E_Ongeldige unitnaam: $1
 | ||
| % The name of the unit doesn't match the file name.
 | ||
| unit_f_too_much_units=10019_F_Te veel units
 | ||
| % \fpc has a limit of 1024 units in a program. You can change this behavior
 | ||
| % by changing the \var{maxunits} constant in the \file{files.pas} file of the
 | ||
| % compiler, and recompiling the compiler.
 | ||
| unit_f_circular_unit_reference=10020_F_Uses statement veroorzaakt vicieuze cirkel
 | ||
| % Two units are using each other in the interface part. This is only allowed
 | ||
| % in the \var{implementation} part. At least one unit must contain the other one
 | ||
| % in the \var{implementation} section.
 | ||
| unit_f_cant_compile_unit=10021_F_Kan unit $1 niet compileren, geen broncode beschikbaar
 | ||
| % A unit was found that needs to be recompiled, but no sources are
 | ||
| % available.
 | ||
| unit_f_cant_find_ppu=10022_F_Kan unit $1 niet vinden
 | ||
| % You tried to use a unit of which the PPU file isn't found by the
 | ||
| % compiler. Check your config files for the unit pathes
 | ||
| unit_w_unit_name_error=10023_W_Unit $1 niet gevonden maar $2 bestaat
 | ||
| unit_f_unit_name_error=10024_F_Unit $1 gezocht maar $2 gevonden
 | ||
| % Dos truncation of 8 letters for unit PPU files
 | ||
| % may lead to problems when unit name is longer than 8 letters.
 | ||
| unit_w_switch_us_missed=10025_W_De systeemunit compileren vereist de -Us schakelaar
 | ||
| % When recompiling the system unit (it needs special treatment), the
 | ||
| % \var{-Us} must be specified.
 | ||
| unit_f_errors_in_unit=10026_F_Er waren fouten $1 bij het compileren van een module, compilatie gestopt.
 | ||
| % When the compiler encounters a fatal error or too many errors in a module
 | ||
| % then it stops with this message.
 | ||
| unit_u_load_unit=10027_U_Laden van $1 ($2) unit $3
 | ||
| % When you use the \var{-vu} flag, which unit is loaded from which unit is
 | ||
| % shown.
 | ||
| unit_u_recompile_crc_change=10028_U_Hercompileer $1, checksum voor $2 veranderd
 | ||
| unit_u_recompile_source_found_alone=10029_U_herkompileer $1, alleen bron gevonden
 | ||
| % When you use the \var{-vu} flag, these messages tell you why the current
 | ||
| % unit is recompiled.
 | ||
| unit_u_recompile_staticlib_is_older=10030_U_Hercompileer unit, statische bibliotheek ouder dan ppu-bestand
 | ||
| % When you use the \var{-vu} flag, the compiler warns if the static library
 | ||
| % of the unit are older than the unit file itself.
 | ||
| unit_u_recompile_sharedlib_is_older=10031_U_Hercompileer unit, dynamische bibliotheek ouder dan ppu-bestand
 | ||
| % When you use the \var{-vu} flag, the compiler warns if the shared library
 | ||
| % of the unit are older than the unit file itself.
 | ||
| unit_u_recompile_obj_and_asm_older=10032_U_Hercompileer unit, object en asm zijn ouder dan ppu-bestand
 | ||
| % When you use the \var{-vu} flag, the compiler warns if the assembler of
 | ||
| % object file of the unit are older than the unit file itself.
 | ||
| unit_u_recompile_obj_older_than_asm=10033_U_Hercompileer unit, object is ouder dan assembler
 | ||
| % When you use the \var{-vu} flag, the compiler warns if the assembler
 | ||
| % file of the unit is older than the object file of the unit.
 | ||
| unit_u_start_parse_interface=10034_U_Parsen van interface van $1
 | ||
| % When you use the \var{-vu} flag, the compiler warns that it starts
 | ||
| % parsing the interface part of the unit
 | ||
| unit_u_start_parse_implementation=10035_U_Parsen van implementatie van $1
 | ||
| % When you use the \var{-vu} flag, the compiler warns that it starts
 | ||
| % parsing the implementation part of the unit
 | ||
| unit_u_second_load_unit=10036_U_Tweede maal unit $1 laden
 | ||
| % When you use the \var{-vu} flag, the compiler warns that it starts
 | ||
| % recompiling a unit for the second time. This can happend with interdepend
 | ||
| % units.
 | ||
| unit_u_check_time=10037_U_PPU Controleren van bestand $1 tijd $2
 | ||
| % When you use the \var{-vu} flag, the compiler show the filename and
 | ||
| % date and time of the file which a recompile depends on
 | ||
| % \end{description}
 | ||
| # EndOfTeX
 | ||
| #
 | ||
| #  Options
 | ||
| #
 | ||
| option_usage=11000_$1 [opties] <bestand> [opties]
 | ||
| # BeginOfTeX
 | ||
| %
 | ||
| % \section{Command-line handling errors}
 | ||
| % This section lists errors that occur when the compiler is processing the
 | ||
| % command line or handling the configuration files.
 | ||
| % \begin{description}
 | ||
| option_only_one_source_support=11001_Maar een (1) bronbestand wordt ondersteunt
 | ||
| % You can specify only one source file on the command line. The first
 | ||
| % one will be compiled, others will be ignored. This may indicate that
 | ||
| % you forgot a \var{'-'} sign.
 | ||
| option_def_only_for_os2=11002_Een DEF file kan alleen worden gemaakt voor OS/2
 | ||
| % This option can only be specified when you're compiling for OS/2
 | ||
| option_no_nested_response_file=11003_Geneste optie bestanden niet ondersteund
 | ||
| % you cannot nest response files with the \var{@file} command-line option.
 | ||
| option_no_source_found=11004_Geen bronbestand op de commando-lijn
 | ||
| % The compiler expects a source file name on the command line.
 | ||
| option_no_option_found=11005_N_geen opties in configuratie bestand $1
 | ||
| % The compiler didn't find any option in that config file.
 | ||
| option_illegal_para=11006_Ongeldige parameter: $1
 | ||
| % You specified an unknown option.
 | ||
| option_help_pages_para=11007_-? druk hulp af
 | ||
| % When an unknown option is given, this message is diplayed.
 | ||
| option_too_many_cfg_files=11008_Te veel geneste instellingsbestanden
 | ||
| % You can only nest up to 16 config files.
 | ||
| option_unable_open_file=11009_Kan bestand $1 niet openen
 | ||
| % The option file cannot be found.
 | ||
| option_reading_further_from=11010_Meer instellingen worden gelezen van $1
 | ||
| % Displayed when you have notes turned on, and the compiler switches
 | ||
| % to another options file.
 | ||
| option_target_is_already_set=11011_Doel is reeds ingesteld op: $1
 | ||
| % Displayed if more than one \var{-T} option is specified.
 | ||
| option_no_shared_lib_under_dos=11012_Shared bibliotheken niet onderteund onder DOS, val terug op statisch
 | ||
| % If you specify \var{-CD} for the \dos platform, this message is displayed.
 | ||
| % The compiler supports only static libraries under \dos
 | ||
| option_too_many_ifdef=11013_Te veel IF(N)DEFs
 | ||
| % the \var{\#IF(N)DEF} statements in the options file are not balanced with
 | ||
| % the \var{\#ENDIF} statements.
 | ||
| option_too_many_endif=11014_Te veel ENDIFs
 | ||
| % the \var{\#IF(N)DEF} statements in the options file are not balanced with
 | ||
| % the \var{\#ENDIF} statements.
 | ||
| option_too_less_endif=11015_Open voorwaardelijke aan eind van bestand
 | ||
| % the \var{\#IF(N)DEF} statements in the options file are not balanced with
 | ||
| % the \var{\#ENDIF} statements.
 | ||
| option_no_debug_support=11016_Debug informatie generatie wordt niet ondersteund door deze applicatie
 | ||
| % It is possible to have a compiler executable that doesn't support
 | ||
| % the generation of debugging info. If you use such an executable with the
 | ||
| % \var{-g} switch, this warning will be displayed.
 | ||
| option_no_debug_support_recompile_fpc=11017_Hercompileer de compiler-applicatie met -dGDB
 | ||
| % It is possible to have a compiler executable that doesn't support
 | ||
| % the generation of debugging info. If you use such an executable with the
 | ||
| % \var{-g} switch, this warning will be displayed.
 | ||
| option_obsolete_switch=11018_W_U gebruikt een in onbruik geraakte schakeloptie $1
 | ||
| % this warns you when you use a switch that is not needed/supported anymore.
 | ||
| % It is recommended that you remove the switch to overcome problems in the
 | ||
| % future, when the switch meaning may change.
 | ||
| option_obsolete_switch_use_new=11019_W_U gebruikt een in onbruik geraakte schakeloptie $1, gebruik $2 a.u.b.
 | ||
| % this warns you when you use a switch that is not supported anymore. You
 | ||
| % must now use the second switch instead.
 | ||
| % It is recommended that you change the switch to overcome problems in the
 | ||
| % future, when the switch meaning may change.
 | ||
| option_switch_bin_to_src_assembler=11020_N_De assembler wordt veranderd in de standaard assemblerschrijver
 | ||
| % this notifies you that the assembler has been changed because you used the
 | ||
| % -a switch which can't be used with a binary assembler writer.
 | ||
| option_incompatible_asm=11021_W_Geselecteerde assembler "$1" is niet verenigbaar met "$2"
 | ||
| option_asm_forced=11022_W_Gebruik van "$1" assembler opgelegd
 | ||
| % The assembler output selected can not generate
 | ||
| % object files with the correct format. Therefore, the
 | ||
| % default assembler for this target is used instead.
 | ||
| %\end{description}
 | ||
| # EndOfTeX
 | ||
| 
 | ||
| #
 | ||
| # Logo (option -l)
 | ||
| #
 | ||
| option_logo=11023_[
 | ||
| Free Pascal Compiler versie $FPCVER [$FPCDATE] voor $FPCTARGET
 | ||
| Copyright (c) 1998-2003 door Florian Klaempfl en anderen
 | ||
| ]
 | ||
| 
 | ||
| #
 | ||
| # Info (option -i)
 | ||
| #
 | ||
| option_info=11024_[
 | ||
| Free Pascal Compiler versie $FPCVER
 | ||
| 
 | ||
| Compiler datum:       $FPCDATE
 | ||
| Compiler doelsysteem: $FPCTARGET
 | ||
| 
 | ||
| Dit programma wordt verspreid onder de GNU General Public Licence
 | ||
| Voor meer informatie, lees COPYING.FPC. Hiervan is helaas geen
 | ||
| Nederlandse vertaling beschikbaar.
 | ||
| 
 | ||
|                 bugrep@freepascal.org
 | ||
| ]
 | ||
| 
 | ||
| #
 | ||
| # Help pages (option -? and -h)
 | ||
| #
 | ||
| option_help_pages=11025_[
 | ||
| **0*_+ schakelt optie aan, - af
 | ||
| **1a_De compiler verwijdert gegenereerd assemblerbestand niet
 | ||
| **2al_Toon broncode in assemblerbestand
 | ||
| **2ar_Toon register allocatie/release informatie in assemblerbestand
 | ||
| **2at_Toon tijdelijke allocatie/release informatie in assemblerbestand
 | ||
| **1b_genereer browser info
 | ||
| **2bl_genereer info voor lokale symbolen info
 | ||
| **1B_Bouw alle modules
 | ||
| **1C_Codegeneratie opties
 | ||
| 3*2CD_Creeer dynamische bibliotheek
 | ||
| **2Ch<n>_<n> bytes heap (tussen 1023 en 67107840)
 | ||
| **2Ci_IO-checking
 | ||
| **2Cn_Laat linken achterwege
 | ||
| **2Co_Controleer overflow van integeroperaties
 | ||
| **2Cr_Bereikcontrole (range check)
 | ||
| **2Cs<n>_Stel stack grootte in op <n>
 | ||
| **2Ct_Stack controle
 | ||
| 3*2CS_Cre<72>er dynamische bibliotheek
 | ||
| 3*2Cx_Gebruik slim linken
 | ||
| **1d<x>_definieer het symbool <x>
 | ||
| *O1D_genereer een DEF bestand
 | ||
| *O2Dd<x>_Zet beschrijving op <x>
 | ||
| *O2Dw_PM applicatie
 | ||
| **1e<x>_Zet pad naar applicaties
 | ||
| **1E_Zelfde als -Cn
 | ||
| **1F_Zet bestandsnamen en paden
 | ||
| **2Fe<x>_Zend foutboodschappen naar bestand <x>
 | ||
| *L2Fg<x>_Zelfde als -Fl
 | ||
| **2Fi<x>_Voegt <x> toe aan invoegpad
 | ||
| **2Fl<x>_Voegt <x> toe aan bibliotheek-pad
 | ||
| *L2FL<x>_Gebruik <x> als dynamische linker
 | ||
| **2Fo<x>_Voeg <x> toe aan object-pad
 | ||
| **2Fr<x>_Lees foutmeldingen uit bestand <x>
 | ||
| **2Fu<x>_Voeg <x> toe aan unit pad
 | ||
| **2FU<x>_Schrijf units in folder <x>, (primeert op -FE)
 | ||
| *g1g_genereer debuginformatie
 | ||
| *g2gg_gebruik gsym
 | ||
| *g2gd_gebruik dbx
 | ||
| *g2gh_laad heaptrc unit automatisch
 | ||
| *g2gl_Gebruik regelinformatie unit voor meer informatie in backtraces
 | ||
| *g2gc_genereer controles voor pointers
 | ||
| **1i_informatie
 | ||
| **2iD_Toon compilerdatum
 | ||
| **2iV_Toon compilerversie
 | ||
| **2iSO_Toon compiler-OS
 | ||
| **2iSP_Toon compilerprocessor
 | ||
| **2iTO_Toon doel-OS
 | ||
| **2iTP_Toon doelprocessor
 | ||
| **1I<x>_Voeg <x> toe aan invoegpad
 | ||
| **1k<x>_Geef <x> door aan de linker
 | ||
| **1l_Druk logo af
 | ||
| **1n_Standaard configuratie bestand niet lezen
 | ||
| **1o<x>_Stel de naam van het applicatiebestand in op <x>
 | ||
| **1pg_genereer profile code voor gprof
 | ||
| *L1P_Gebruik pipes in plaats van tijdelijke assembler bestanden
 | ||
| **1S_Syntax instellingen
 | ||
| **2S2_Stel Delphi 2 uitbreidingen in
 | ||
| **2Sc_Ondersteun operatoren als in C (*=,+=,/= en -=)
 | ||
| **2sa_Voeg assertion code toe
 | ||
| **2S2_Tracht Delphi compatibel te zijn
 | ||
| **2Se<x>_Compiler stopt na <x> fouten (standaard 1)
 | ||
| **2Sg_Laat LABEL en GOTO toe
 | ||
| **2Sh_Gebruik ansistrings
 | ||
| **2Si_Ondersteun INLINE
 | ||
| **2Sm_Ondersteun macros zoals in C (globaal)
 | ||
| **2So_Probeer TP/BP 7.0 compatibel te zijn
 | ||
| **2Sp_Probeer GNU Pascal compatibel te zijn
 | ||
| **2Ss_Constructor naam moet init zijn (destructor moet done zijn)
 | ||
| **2St_Sta static sleutelwoord toe in objecten
 | ||
| **1s_Roep assembler en linker niet op (slechts met -a)
 | ||
| **1sh_Genereer een script om op het hostplatform te linken
 | ||
| **1sr_Voer geen registertoewijzing uit (optimalizaties worden uitgeschakeld)
 | ||
| **1st_Genereer een script om op het doelplatform te linken
 | ||
| **1u<x>_Verwijdert symbooldefinitie <x>
 | ||
| **1U_unit opties
 | ||
| **2Un_Unit naam niet nagaan
 | ||
| **2Us_Compileer een systeemunit
 | ||
| **1v<x>_Wees uitvoerig. <x> is een combinatie van volgende letters:
 | ||
| **2*_e : Toon fouten (standaard)     d : Toon debug informatie
 | ||
| **2*_w : Toon waarschuwingen         u : Toon gebruikte bestanden
 | ||
| **2*_n : Toon notas                  t : Toon geteste bestanden
 | ||
| **2*_h : Toon hints                  m : Toon gedefinieerde macros
 | ||
| **2*_i : Toon algemene informatie    p : Toon gecompileerde routines
 | ||
| **2*_l : Toon regelnummers           c : Toon voorwaardelijken
 | ||
| **2*_a : Toon alles                  0 : Toon alleen fouten
 | ||
| **2*_b : Toon alle procedures        r : Rhide/GCC compatibiliteit modus
 | ||
| **2*_    declaraties indien een     x : Executable informatie (alleen Win32)
 | ||
| **2*_    fout optreedt
 | ||
| **1X_applicatie instellingen
 | ||
| *L2Xc_link met de C bibliotheek
 | ||
| **2Xs_verwijder alle symbolen uit applicatie
 | ||
| **2XD_link met dynamische bibliotheken (definieert FPC_LINK_DYNAMIC)
 | ||
| **2XS_link met statische bibliotheken (definieert FPC_LINK_STATIC)
 | ||
| **2XS_link slim (definieert FPC_LINK_STATIC_SMART)
 | ||
| **0*_Processor specifieke instellingen:
 | ||
| 3*1A_Output formaat
 | ||
| 3*2Aas_assembleer met GNU AS
 | ||
| 3*2Aasaout_assembleer met GNU AS voor aout (Go32v1)
 | ||
| 3*2Anasmcoff_Coff (Go32v2) bestand met Nasm
 | ||
| 3*2Anasmelf_elf32 (linux) bestand met Nasm
 | ||
| 3*2Anasmobj_obj bestand met Nasm
 | ||
| 3*2Amasm_obj bestand met Masm (Microsoft)
 | ||
| 3*2Atasm_obj bestand met Tasm (Borland)
 | ||
| 3*2Acoff_coff (Go32v2) met interne assembler
 | ||
| 3*2Apecoff_pecoff (Win32) met interne assembler
 | ||
| 3*1R<x>_Geef de grammatica voor de assemblerlezer op:
 | ||
| 3*2Ratt_Lees assembler in AT&T stijl
 | ||
| 3*2Rintel_Lees assembler in Intel stijl
 | ||
| 3*2Rdirect_Kopieer assemblercode rechtstreeks naar assemblerbestand
 | ||
| 3*1O<x>_optimalizaties
 | ||
| 3*2Og_Genereer kleinere code
 | ||
| 3*2OG_Genereerd snellere code (standaard)
 | ||
| 3*2Or_Houdt zekere variabelen in registers (Nog steeds BUGGY!!!)
 | ||
| 3*2Ou_Probeer onzekere optimalizaties (zie documentatie)
 | ||
| 3*2O1_Niveau 1 optimalizaties (snelle optimizaties)
 | ||
| 3*2O2_Niveau 2 optimalizaties (-O1 + tragere optimizaties)
 | ||
| 3*2O3_Niveau 3 optimalizaties (Zelfde als -O2u)
 | ||
| 3*2Op_Doelprocessor
 | ||
| 3*3Op1_Stel doelprocessor in op 386/486
 | ||
| 3*3Op2_Stel doelprocessor in op Pentium/PentiumMMX (tm)
 | ||
| 3*3Op3_Stel doelprocessor in op PPro/PII/c6x86/K6 (tm)
 | ||
| 6*1T<x>_Doel besturingssysteem:
 | ||
| 3*2TGO32V2_version 2 of DJ Delorie DOS extender
 | ||
| 3*2TLINUX_Linux
 | ||
| 3*2TOS2_OS/2 / eComStation
 | ||
| 3*2TWIN32_Windows 32 Bit
 | ||
| 3*1W<x>_Win32 Doel opties
 | ||
| 3*2WB<x>_Stel Image base in op (hexadecimale) waarde <x>
 | ||
| 3*2WC_Maak een console applicatie
 | ||
| 3*2WD_Gebruik DEFFILE om functies van bibliotheek of applicatie te exporteren
 | ||
| 3*2WG_Maak een grafische applicatie
 | ||
| 3*2WN_Genereer geen relocatie code (nodig voor debuggen)
 | ||
| 3*2WR_Genereer relocatie code
 | ||
| 6*1A_output formaat
 | ||
| 6*2Aas_Unix o-bestand met GNU AS
 | ||
| 6*2Agas_GNU Motorola assembler
 | ||
| 6*2Amit_MIT Syntax (oude GAS)
 | ||
| 6*2Amot_Standaard Motorola assembler
 | ||
| 6*1O_optimizaties
 | ||
| 6*2Oa_Gebruik de optimizaties
 | ||
| 6*2Og_Genereer kleinere code
 | ||
| 6*2OG_Genereer snellere code (standaard)
 | ||
| 6*2Ox_Optimizeer maximaal (nog steeds BUGGY!!!)
 | ||
| 6*2O2_Stel doelprocessor in op MC68020+
 | ||
| 6*1R<x>_assembler reading style:
 | ||
| 6*2RMOT_read motorola style assembler
 | ||
| 6*1T<x>_Target operating system:
 | ||
| 6*2TAMIGA_Commodore Amiga
 | ||
| 6*2TATARI_Atari ST/STe/TT
 | ||
| 6*2TMACOS_Macintosh m68k
 | ||
| 6*2TLINUX_Linux-68k
 | ||
| **1*_
 | ||
| **1?_Toont deze hulp
 | ||
| **1h_Toont deze hulp zonder wachten
 | ||
| ]
 | ||
| 
 | ||
| #
 | ||
| # The End...
 | ||
| #
 | 
